首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
Lactic acid bacteria (LAB) play an important role as natural preservatives in fermented food and beverage systems, reducing the application of chemical additives. Thus, investigating their antifungal compounds, such as cyclic dipeptides, has gained prominence. Previous research has primarily focussed on isolation of these compounds. However, their precise quantification will provide further information regarding their antifungal performance in a complex system. To address this, deuterated labelled standards of the cyclic dipeptides cyclo(Leu-Pro), cyclo(Pro-Pro), cyclo(Met-Pro) and cyclo(Phe-Pro) were synthesized, and stable isotope dilution assays were developed, enabling an accurate quantification of cyclo(Leu-Pro), cyclo(Pro-Pro), cyclo(Met-Pro) and cyclo(Phe-Pro) in MRS-broth and wort. Quantitative results showed that, in the Lactobacillus brevis R2Δ fermented MRS-broth, the concentrations of cyclo(Leu-Pro), cyclo(Pro-Pro) and cyclo(Phe-Pro) were significantly higher (P?<?0.05), than in wort for cyclo (Leu-Pro) when compared with their controls. This indicates that the formation of these three cyclic dipeptides is related to L. brevis R2Δ metabolism. Furthermore, this represents the first report of cyclic dipeptides quantification using stable isotope dilution assays in LAB cultures both in vitro and in a food system.  相似文献   

2.
ICP–MS techniques based on isotope dilution analysis can be regarded as an emerging tool in quantitative protein analysis. Well-known concepts, for example species-specific and unspecific isotope dilution analysis, which promoted accurate and precise quantification in elemental speciation studies, have nowadays been transferred to the analysis of large biomolecules, e.g. proteins. Besides detection of heteroatom-containing proteins, the artificial introduction of metal-containing labels has attracted much attention and, as a consequence, ICP–MS-based isotope dilution techniques can serve as a valuable quantification tool. In particular, because isotope dilution ICP–MS techniques can enable absolute protein quantification, they can be regarded as an attractive technique in current and prospective proteomics. In this review, recent developments and applications will be highlighted and critically assessed.  相似文献   

3.
Lesinurad is an oral inhibitor of urate-anion exchanger transporter 1 and has been approved by the US Food and Drug Administration for combination therapy with a xanthine oxidase inhibitor for the treatment of hyperuricemia associated with refractory gout. In the present study, a sensitive and specific ultra high-performance liquid chromatography with tandem mass spectrometry assay was established and verified for the determination of lesinurad in rat plasma and was described in details for the first time. Chromatographic separation of lesinurad and diazepam (internal standard, IS) was performed on a Rapid Resolution HT C18 column (3.0 × 100 mm, 1.8 µm) using methanol–water (70:30, v/v) as the mobile phase at a flow rate of 0.3 mL/min. Lesinurad and IS were extracted from plasma by liquid–liquid extraction using ethyl acetate. The mass spectrometric detection was carried out using an electrospray ionization source in positive mode. Multiple reaction monitoring was used for quantification of the precursor to product ion at m/z 405.6 → 220.9 for lesinurad and m/z 285.1 → 192.8 for IS. The assay was well validated for selectivity, accuracy, precision, recovery, linearity, matrix effects, and stability. The verified method was applied to obtain the pharmacokinetic parameters and concentration–time profiles for lesinurad after oral/intravenous administration in rats. The study might provide an important reference and a necessary complement for the qualitative and quantitative evaluation of lesinurad.  相似文献   

4.
Two rapid,sensitive and reliable immunoassay methods,namely competitive indirect enzyme-linked immunosorbent assay(CI- ELISA)and colloidal gold-based immunochromatographic assay(CGIA),were developed to detect ofloxacin(OFL).The linear range of the CI-ELISAwas from 0.5 to 128 ng/mL with a limit of detection(LOD)of 0.35 ng/mL.Good recoveries were obtained in analyzing simulated swine urine samples.The CGIA could accurately estimate OFL at concentrations as low as 10 ng/mL in less than 10 min,and test results were read visually without any instrument.  相似文献   

5.
A coprecipitation method using sample constituents as carrier precipitants was developed that can remove molybdenum, which interferes with the determination of cadmium in grain samples via isotope dilution inductively coupled plasma mass spectrometry (ID-ICPMS). Samples were digested with HNO3, HF, and HClO4, and then purified 6 M sodium hydroxide solution was added to generate colloidal hydrolysis compounds, mainly magnesium hydroxide. Cadmium can be effectively separated from molybdenum because the cadmium forms hydroxides and adsorbs onto and/or is occluded in the colloid, while the molybdenum does not form hydroxides or adsorb onto the hydrolysis colloid. The colloid was separated by centrifugation and then dissolved with 0.2 M HNO3 solution to recover the cadmium. The recovery of Cd achieved using the coprecipitation was >97%, and the removal efficiency of Mo was approximately 99.9%. An extremely low procedural blank (below the detection limit of ICPMS) was achieved by purifying the 6 M sodium hydroxide solution via Mg coprecipitation using Mg(NO3)2 solution. The proposed method was applied to two certified reference materials (NIST SRM 1567a wheat flour and SRM 1568a rice flour) and CCQM-P64 soybean powder. Good analytical results with small uncertainties were obtained for all samples. This method is simple and reliable for the determination of Cd in grain samples by ID-ICPMS. Figure Overview of a coprecipitation method using sample constituents  相似文献   

6.
The isoprenoids farnesyl-(FPP) and geranylgeranylpyrophosphate (FPP and GGPP) are two major lipid intermediates in the mevalonate pathway. They participate in post-translational modification of members of the superfamily of small guanosine triphosphatases (GTPases; Ras, Rab, Rac, etc.) via prenylation reactions. Due to the important role of these proteins in a number of cell processes, in particular cell growth, division, and differentiation, investigation of the involvement of isoprenoids in these processes is of great interest. In a previously published report, we described a fully validated assay for the quantitation of the two isoprenoids using a high-performance liquid chromatography (HPLC)–fluorescence detection (FLD) method. The current work expands on the previous method and enhances it greatly by using a much faster state-of-the-art ultrahigh-performance liquid chromatography (UHPLC) technique coupled to tandem mass spectrometry (MS/MS). The method exhibited a linear concentration range of 5–250 ng/mL for FPP and GGPP in human brain tissue; it was shown to be unaffected by ion suppression and provided results almost six times faster than the HPLC–FLD assay. Comparison of UHPLC–MS/MS and HPLC–FLD yielded excellent comparability of the two assays for both isoprenoids. Based on the UHPLC–MS/MS assay, a novel in vitro test system was implemented to study enzyme specificity for distinct amino acid CAAX motifs, which is potentially useful for investigating target interactions of new therapeutics for diseases involving pathological regulation of isoprenoids and/or small GTPases.  相似文献   

7.
The neuraminidase inhibitor oseltamivir (Tamiflu®) is currently the first-line therapy for patients with influenza virus infection. Common analysis of the prodrug and its active metabolite oseltamivircarboxylate is determined via extraction from plasma. Compared with these assays, dried blood spot (DBS) analysis provides several advantages, including a minimum sample volume required for the measurement of drugs in whole blood. Samples can easily be obtained via a simple, non-invasive finger or heel prick. Mainly, these characteristics make DBS an ideal tool for pediatrics and to measure multiple time points such as those needed in therapeutic drug monitoring or pharmacokinetic studies. Additionally, DBS sample preparation, stability, and storage are usually most convenient. In the present work, we developed and fully validated a DBS assay for the simultaneous determination of oseltamivir and oseltamivircarboxylate concentrations in human whole blood. We demonstrate the simplicity of DBS sample preparation, and a fast, accurate and reproducible analysis using ultra high-performance liquid chromatography coupled to a triple quadrupole mass spectrometer. A thorough validation on the basis of the most recent FDA guidelines for bioanalytical method validation showed that the method is selective, precise, and accurate (≤15% RSD), and sensitive over the relevant clinical range of 5–1,500 ng/mL for oseltamivir and 20–1,500 ng/mL for the oseltamivircarboxylate metabolite. As a proof of concept, oseltamivir and oseltamivircarboxylate levels were determined in DBS obtained from healthy volunteers who received a single oral dose of Tamiflu®.  相似文献   

8.
Trace amounts of thyroxine in model samples (160.0 ng.ml–1 and 20.0 ng.ml–1), and thyroxine and 3,5,3-triiodothyronine in blood plasma were determined by sub- superequivalence isotope dilution analysis and radio-immunoassay technique. Hormones were labelled by125I. The separation of antibody-bound hormone from free hormone was performed by ultracentrifugation. The results show higher accuracy of the sub- super-equivalence isotope dilution method over that of radioimunoassay.  相似文献   

9.
Inductively coupled plasma isotope-dilution mass spectrometry (ICP–IDMS) with direct injection of isotope-diluted samples into the plasma, using a direct injection high-efficiency nebulizer (DIHEN), was applied for accurate sulfur determinations in sulfur-free premium gasoline, gas oil, diesel fuel, and heating oil. For direct injection a micro-emulsion consisting of the corresponding organic sample and an aqueous 34S-enriched spike solution with additions of tetrahydronaphthalene and Triton X-100, was prepared. The ICP–MS parameters were optimized with respect to high sulfur ion intensities, low mass-bias values, and high precision of 32S/34S ratio measurements. For validation of the DIHEN–ICP–IDMS method two certified gas oil reference materials (BCR 107 and BCR 672) were analyzed. For comparison a wet-chemical ICP–IDMS method was applied with microwave-assisted digestion using decomposition of samples in a closed quartz vessel inserted into a normal microwave system. The results from both ICP–IDMS methods agree well with the certified values of the reference materials and also with each other for analyses of other samples. However, the standard deviation of DIHEN–ICP–IDMS was about a factor of two higher (5–6% RSD at concentration levels above 100 g g–1) compared with those of wet-chemical ICP–IDMS, mainly due to inhomogeneities of the micro-emulsion, which causes additional plasma instabilities. Detection limits of 4 and 18 g g–1 were obtained for ICP–IDMS in connection with microwave-assisted digestion and DIHEN–ICP–IDMS, respectively, with a sulfur background of the used Milli-Q water as the main limiting factor for both methods.This paper was presented as a poster at the 2004 winter conference on plasma spectrochemistry, Fort Lauderdale, January 5–10, 2004  相似文献   

10.
The chemical components of both Syrian aniseed and fennel seeds collected from Idlib and Aleppo regions were identified using GC/MS spectrometry. Thirty-four component fractions representing an average of 98.5% of anise seed extract were characterized. The major average components were (E)-Anethole, Estragole, Limonene, Fenchone, Linalool, para-Anisaldehyde, (Z)-Anethole, and methyl chavicol. Also, thirty-one component fractions representing an average of 99.46% of fennel seed extract were identified. The major components were α-Pinene, α-Phellandrene, Fenchone, Methyl chavicol, Estragole, (Z)-Anethole, Limonene, 1,8-Cineole, Anisole-p-allyl, E,E-Farnesene, Estragole, (E)-Anethole, Anisaldehyde, and Carvacrol. The extract of aniseed was characterized by higher amounts of trans-anethole (52.2%) than fennel extract (38.3%). The integral antioxidant capacity (IAC) of two different extracts from both aniseed and fennel seeds have been determined using photochemiluminescence assay (PCL). The sum of antioxidant capacity (IAC) of hydrophilic and hydrophobic components in both aniseed and fennel seeds was determined, as a total equivalent per gram of dry material (nmolTE/gDM) at 166.69 ± 0.42 and 363.28 ± 1.11 nmol for hydrophilic and hydrophobic components, respectively. Eight major phenolic compounds known as possible antioxidant sources with their concentrations have been identified in both aniseed and fennel seeds by HPLC and GC–MS analysis.  相似文献   

11.
Enthalpies of the dissolution and dilution of aqueous solutions of rubidium and cesium diclofenac (RbDC and CsDC) are measured at 293.15, 298.15, 308.15, and 318.15 K at concentrations of water of less than 0.1 mol/kg. The heat capacity of RbDC and CsDC crystal salts is determined. Changes in the thermodynamic properties of both a solution and its components vs. concentration and temperature is considered. An increase in the endothermicity of the dissolution of RbDC and CsDC with a rise in temperature is noted. It is shown that the dissolution of both RbDC and CsDC electrolytes in water is determined by the contribution from entropy. It is shown that in aqueous solutions of RbDC and CsDC, the degree of binding of water molecules is higher than in pure water at temperatures below 303.15 K.  相似文献   

12.
A simple and simultaneous reverse phase high-performance liquid chromatographic method was developed for the quantification of aripiprazole (ARI) and two preservatives, namely, methyl paraben and propyl paraben in ARI oral solution. The method was developed on ACE C18 (4.6?×?250?mm, 5?µm) column using gradient elution of 0.1% v/v trifluoroacetic acid in water and acetonitrile as mobile phase components. Flow rate of 1.0?mL/min and 30°C column temperature were used for the method at quantification wavelength of 254?nm. The developed method was validated in accordance with International Conference on Harmonization guideline for various parameters. Forced degradation study was conducted in acid, base, peroxide, heat, and light stress conditions. ARI was found to degrade in oxidation, acid hydrolysis, and heat while it was stable under the remaining conditions. Specificity of the method was verified using Photo Diode Array (PDA) detector by evaluating purity of peaks from degradation samples. Major degradation impurities formed during stress study were identified using liquid chromatography–mass spectrometry method. The present method was useful for determining the content of all the three main analytes present in the oral solution without interference from degradation impurities. The method was robust under the deliberately modified conditions.  相似文献   

13.
A rapid, precise, and reliable liquid chromatography tandem mass spectrometry (LC–MS/MS) method has been developed for the characterization of stressed degradation products of mirabegron. It is used in the treatment of overactive bladder and administered to treat urinary symptoms such as urgency or frequency and incontinence. It also works by relaxing the muscles around bladder.

Mirabegron was subjected to hydrolysis (acidic, alkaline, and neutral) and peroxidation, as per ICH-specified conditions. The drug showed degradation under stress conditions. However, it was stable to neutral conditions. A total of seven degradation products were observed and the chromatographic separation of the drug and its degradation products was achieved on X-TerraRP-8 (250 mm × 4.6 mm, i.d., 5 µm) column using 0.01 M ammonium acetate as mobile phase-A and 60:40 ratio of acetonitrile (ACN):water as mobile phase-B. The degradation products were characterized by LC–MS/MS and its fragmentation pathways were proposed. Probable possible structures were drawn based on parent and daughter molecular ions. One peroxide degradant impurity was isolated using preparative LC and characterized using liquid chromatography–mass spectrometry and NMR data.  相似文献   

14.
The heat of solution of GaCl3 and heats of dilution of single GaCl3 solutions in water and of mixed GaCl3−HCl solutions in HCl solutions (with a fixed HCl concentration of 0.1337 mol-kg−1 HCl) up to 4 mol-kg−1 GaCl3 were measured at 25°C. While in the acid solutions hydrolysis is suppressed to below 0.5% of total gallium concentration, the measurements in water allow evaluation of the effect of hydrolysis on the relative enthalpy. The Pitzer interaction model for excess properties of aqueous electrolytes was used to interpret the change in relative enthalpy with concentration. Pitzer parameters were derived by statistical inference using ridge regression. Their physical significance is supported by the heat of solution data. The measurements yield the following results for standard heats of formation and Pitzer parameters for the relative molar enthalpy at 25°C: With these parameters the overall variance in the partial molar heat of solution at infinite dilution, extrapolated from the present experiments, is minimized to 0.35 kJ2-mol−2, while the experimental apparent molar heats of dilution are reproduced on average within 2.7 kJ-mol−1.  相似文献   

15.
If sample pretreatment, nebulization and method of calibration are suitably adapted to each other the performance of inductively coupled plasma - mass spectrometry ICP-MS can be greatly increased. High accuracy is obtained by high precision and low bias. For a given concentration higher sensitivity means higher count rates and therefore higher precision. Systematic errors are minimized by employing a definitive method of calibration. Increased sensitivity is obtained by introducing higher amounts of sample into the measurement system via high efficiency nebulizers (ultrasonic nebulizer, hydraulic-high pressure nebulizer according to Berndt and concentric high efficiency nebulizer according to Meinhard). Because this means also higher matrix effects a combination of ion chromatographic (IC-TMS) and thermal trace-matrix-separation by aerosol desolvation (T-TMS) is introduced. Isotope dilution (ID) proves to be the calibration most suitable to achieve the highest accuracy. First applications on the analysis of refractory metals (e.g. Ti, V, Nb, Ta) and non-metals (e.g. P, S, As, Se) showed recoveries of 60-105%, an imprecision of the recoveries of 2-50%, but an overall inaccuracy of only 0.1 to 4%.  相似文献   

16.
A stable isotope dilution assay was adopted for quantitation of folate vitamers in sea buckthorn berries, juice, and concentrate using fourfold labeled folate isotopologues of the folate derivatives as the internal standards and reversed-phase liquid chromatography-tandem mass spectrometry with electrospray ionization (LC-ESI-MS/MS). Processing effects and storage stability were investigated during juice and concentrate production from sea buckthorn berries (Hippopha? rhamnoides). The technological processing of the berries caused a total degradation of tetrahydrofolate and 5-formyltetrahydrofolate in the generated juice. The content of the main folate vitamer 5-methyltetrahydrofolate remained approximately unchanged during the whole processing from the berries to the concentrate. Sea buckthorn juice was stored under two household storage conditions (6 degrees C, 25 degrees C), and also under accelerated aging conditions (40 degrees C) for up to 7 days to determine the effects of storage temperature on the stability of 5-methyltetrahydrofolate. The content of 5-methyltetrahydrofolate was nearly unchanged during the storage at 6 degrees C after 7 days. The juice showed almost identical degradation of 5-methyltetrahydrofolate of about 17-20% at 25 degrees C and 40 degrees C after 7 days of storage. [figure: see text]  相似文献   

17.
A stability indicating RP-HPLC method for cephalexin has been developed and validated to identify and characterize potential degradation products. Drug was subjected to hydrolytic (acidic, basic, and neutral), oxidative, thermal, and photolytic stresses as per ICH guidelines Q1A (R2) and Q1B. Chromatographic separation was achieved on C8 column with mixture of ammonium acetate buffer pH 4.5 and acetonitrile in gradient mode as a mobile phase with PDA detection. Specificity of the method was established by peak purity studies. Method was validated as per ICH guideline Q2 (R1) for accuracy, precision, linearity, sensitivity, and robustness. Kinetics for each degradation condition was studied with respect to order of reaction and rate constant. Method was found to comply with acceptance criteria of validation parameters with respect to specificity (peak purity greater than 0.999) linearity (r 2 greater than 0.99), accuracy (% recovery in the range of 98–102%), and precision (% RSD not more than 2). A total of six degradation products were generated in different stress conditions; these were identified and structures were proposed using LC–MS/MS. Cephalexin undergoes degradation in almost all the conditions. The developed stability indicating method is suitable for analysis of stability samples as it adequately separates all degradation products. Degradation products generated in photolytic and oxidative conditions are reported for the first time.  相似文献   

18.
Determination of ten sulfonamides (SAs) in egg and honey has been compared using column liquid chromatography (LC) and ultra-performance liquid chromatography (UPLC) coupled to tandem mass spectrometry (MS–MS). A liquid–liquid extraction with acetonitrile followed by solid-phase extraction on a Strata-X cartridge was developed for sample preparation. The analytical performance of both methods was compared applying the alternative matrix-comprehensive in-house validation approach using specially designed software InterVal?. Using UPLC the separation time was shortened about 30% reducing the run time by 8 min and a better resolution was achieved compared to LC. Due to higher peak efficiency achieved with UPLC, the decision limit values obtained by both techniques were almost equal (6.61–9.43 μg kg?1 and 7.25–11.9 μg kg?1 for UPLC and LC, respectively), despite the fact that in UPLC twice lower sample volumes were injected. Satisfactory and comparable recoveries (80–110%) were obtained by UPLC and LC for all the SAs, except for sulfacetamide by LC and sulfabenzamide by both methods. For a majority of the spiked compounds, UPLC gave significantly better precision.  相似文献   

19.
An accurate and sensitive multi-species species-specific isotope dilution GC–ICP–MS method was developed for the simultaneous determination of trimethyllead (Me3Pb+), monomethylmercury (MeHg+) and the three butyltin species Bu3Sn+, Bu2Sn2+, and BuSn3+ in biological samples. The method was validated by three biological reference materials (CRM 477, mussel tissue certified for butyltins; CRM 463, tuna fish certified for MeHg+; DORM 2, dogfish muscle certified for MeHg+). Under certain conditions, and with minor modifications of the sample pretreatment procedure, this method could also be transferred to environmental samples such as sediments, as demonstrated by analyzing sediment reference material BCR 646 (freshwater sediment, certified for butyltins). The detection limits of the multi-species GC–ICP–IDMS method for biological samples were 1.4 ng g−1 for MeHg+, 0.06 ng g−1 for Me3Pb+, 0.3 ng g−1 for BuSn3+ and Bu3Sn+, and 1.2 ng g−1 for Bu2Sn2+. Because of the high relevance of these heavy metal alkyl species to the quality assurance of seafood, the method was also applied to corresponding samples purchased from a supermarket. The methylated lead fraction in these samples, correlated to total lead, varied over a broad range (from 0.01% to 7.6%). On the other hand, the MeHg+ fraction was much higher, normally in the range of 80–100%. Considering that we may expect tighter legislative limitations on MeHg+ levels in seafood in the future, we found the highest methylmercury contents (up to 10.6 μg g−1) in two shark samples, an animal which is at the end of the marine food chain, whereas MeHg+ contents of less than 0.2 μg g−1 were found in most other seafood samples; these results correlate with the idea that MeHg+ is usually of biological origin in the marine environment. The concentration of butyltins and the fraction of the total tin content that is from butyltins strongly depend on possible contamination, due to the exclusively anthropogenic character of these compounds. A broad variation in the butylated tin fraction (in the range of <0.3–49%) was therefore observed in different seafood samples. Corresponding isotope-labeled spike compounds (except for trimethyllead) are commercially available for all of these compounds, and since these can be used in the multi-species species-specific GC-ICP-IDMS method developed here, this technique shows great potential for routine analysis in the future.  相似文献   

20.
Ginseng has been used by the Chinese as a traditional herbal medicine for thousands of years. In view of the growing popularity in the use of ginseng preparations as natural remedies and food supplements worldwide, there is an increasing concern for their abuse in both human and animal sports. Ginsenosides are considered the major constituents of ginseng responsible for its pharmacological properties. In this study, a method was developed for the detection and confirmation of a number of ginsenosides in horse urine. The intact ginsenosides were detected and confirmed at 5–100 ng mL?1 by LC–MS2, and two deglycosylation metabolites, namely protopanaxadiol and protopanaxatriol, could both be detected and confirmed at 2 ng mL?1 by GC–MS2 after trimethylsilylation. The above GC–MS and LC–MS methods were then applied to study the in vitro metabolism of ginsenosides Rg1 and Rb1 and the in vivo urinary metabolites after oral administration of Rg1 to horses. Results obtained reveal the very first evidence for the existence of the metabolites, Rg1 and protopanaxatriol, as glucuronides in urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号