首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An atmospheric pressure laser desorption/ionization mass spectrometry imaging ion source has been developed that combines high spatial resolution and high mass resolution for the in situ analysis of biological tissue. The system is based on an infrared laser system working at 2.94 to 3.10 μm wavelength, employing a Nd:YAG laser-pumped optical parametrical oscillator. A Raman-shifted Nd:YAG laser system was also tested as an alternative irradiation source. A dedicated optical setup was used to focus the laser beam, coaxially with the ion optical axis and normal to the sample surface, to a spot size of 30 μm in diameter. No additional matrix was needed for laser desorption/ionization. A cooling stage was developed to reduce evaporation of physiological cell water. Ions were formed under atmospheric pressure and transferred by an extended heated capillary into the atmospheric pressure inlet of an orbital trapping mass spectrometer. Various phospholipid compounds were detected, identified, and imaged at a pixel resolution of up to 25 μm from mouse brain tissue sections. Mass accuracies of better than 2 ppm and a mass resolution of 30,000 at m/z?=?400 were achieved for these measurements.
Figure
Infrared laser desorption/ionization mass spectrometry imaging provides for direct analysis of biological tissue with a high spatial resolution of 25 μm  相似文献   

2.
李文杰  王利雪  孙令辉  游伟  赵雅彬 《应用化学》2020,37(10):1137-1146
基质辅助激光解吸电离质谱(MALDI-MS)是一种高灵敏度、高通量、多组分同时分析的软电离质谱技术,可通过对物质分析实现分子结构的确认及物质分布信息的获取,因此在指纹分析中获得越来越多的关注。 本文从条件优化入手,讲述基质优化过程。 接着介绍了MALDI-MS成像(MALDI-MSI)在指纹分析领域具体的应用,在形态分析研究方面,总结其与常规显现方法联用对成像效果的影响、对疑难指纹的图像处理;在化学信息分析研究方面,分别从根据质谱信息分析生活习惯/案前活动、指纹遗留时间和个体同一认定对各研究的优点及局限性进行评述,最后为MALDI-MSI在指纹领域未来发展提出展望。  相似文献   

3.
Laser desorption postionization mass spectrometry (LDPI-MS) imaging is demonstrated with a 10.5 eV photon energy source for analysis and imaging of small endogenous molecules within intact biofilms. Biofilm consortia comprised of a synthetic Escherichia coli K12 coculture engineered for syntrophic metabolite exchange are grown on membranes and then used to test LDPI-MS analysis and imaging. Both E. coli strains displayed many similar peaks in LDPI-MS up to m/z 650, although some observed differences in peak intensities were consistent with the appearance of byproducts preferentially expressed by one strain. The relatively low mass resolution and accuracy of this specific LDPI-MS instrument prevented definitive assignment of species to peaks, but strategies are discussed to overcome this shortcoming. The results are also discussed in terms of desorption and ionization issues related to the use of 10.5 eV single-photon ionization, with control experiments providing additional mechanistic information. Finally, 10.5 eV LDPI-MS was able to collect ion images from intact, electrically insulating biofilms at ~100 μm spatial resolution. Spatial resolution of ~20 μm was possible, although a relatively long acquisition time resulted from the 10 Hz repetition rate of the single-photon ionization source.
Figure
Neutral species laser desorbed from cocultured biofilms undergo single photon ionization by VUV radiation and resultant ions are detected by time-of-flight mass spectrometry  相似文献   

4.
Electrospray laser desorption ionization mass spectrometry (ELDI/MS) was used to rapidly distinguish authentic banknotes from counterfeits of the US dollar and the New Taiwan dollar. The banknotes' surfaces were irradiated with a pulsed ultraviolet laser, after which the desorbed ink compounds entered an electrospray plume and formed ions via interactions with charged solvent species. Authentic banknotes were found to differ from their counterfeit equivalents in their surface chemical compositions. The detected chemical compounds included various polymers, plasticizers and inks; these results were comparable with those obtained using solvent extraction followed by electrospray ionization mass spectrometry analysis. Because of the high spatial resolution of the laser beam, ELDI/MS analysis resulted in minimal damage to the banknotes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
In mass spectrometry imaging, spatial resolution is pushed to its limits with the use of ion microscope mass spectrometric imaging systems. An ion microscope magnifies and then projects the original spatial distribution of ions from a sample surface onto a position-sensitive detector, while retaining time-of-flight mass separation capabilities. Here, a new type of position-sensitive detector based on a chevron microchannel plate stack in combination with a 512 × 512 complementary metal-oxide-semiconductor based pixel detector is coupled to an ion microscope. Spatial resolving power better than 6 μm is demonstrated by secondary ion mass spectrometry and 8–10μm spatial resolving power is achieved with laser desorption ionization. A detailed evaluation of key performance criteria such as spatial resolution, acquisition speed, and data handling is presented.  相似文献   

6.
The structural information and spatial distribution of molecules in biological tissues are closely related to the potential molecular mechanisms of disease origin, transfer, and classification. Ambient ionization mass spectrometry imaging is an effective tool that provides molecular images while describing in situ information of biomolecules in complex samples, in which ionization occurs at atmospheric pressure with the samples being analyzed in the native state. Ambient ionization mass spectrometry imaging can directly analyze tissue samples at a fairly high resolution to obtain molecules in situ information on the tissue surface to identify pathological features associated with a disease, resulting in the wide applications in pharmacy, food science, botanical research, and especially clinical research. Herein, novel ambient ionization techniques, such as techniques based on spray and solid‐liquid extraction, techniques based on plasma desorption, techniques based on laser desorption ablation, and techniques based on acoustic desorption were introduced, and the data processing of ambient ionization mass spectrometry imaging was briefly reviewed. Besides, we also highlight recent applications of this imaging technology in clinical researches and discuss the challenges in this imaging technology and the perspectives on the future of the clinical research.  相似文献   

7.
Mass spectrometric imaging allows the investigation of the spatial distribution of molecules at complex surfaces. The combination of molecular speciation with local analysis renders a chemical microscope that can be used for the direct biomolecular characterization of histological tissue surfaces. MS based imaging advantageously allows label-free detection and mapping of a wide-range of biological compounds whose presence or absence can be the direct result of disease pathology. Successful detection of the analytes of interest at the desired spatial resolution requires careful attention to several steps in the mass spectrometry imaging protocol. This review will describe and discuss a selected number of crucial developments in ionization, instrumentation, and application of this innovative technology. The focus of this review is on the latest developments in imaging MS. Selected biological applications are employed to illustrate some of the novel features discussed. Two commonly used MS imaging techniques, secondary ion mass spectrometric (SIMS) imaging and matrix-assisted laser desorption ionization (MALDI) mass spectrometric imaging, center this review. New instrumental developments are discussed that extend spatial resolution, mass resolving power, mass accuracy, tandem-MS capabilities, and offer new gas-phase separation capabilities for both imaging techniques. It will be shown how the success of MS imaging is crucially dependent on sample preparation protocols as they dictate the nature and mass range of detected biomolecules that can be imaged. Finally, developments in data analysis strategies for large imaging datasets will be briefly discussed.  相似文献   

8.
The detailed characterization of macromolecules plays an important role for synthetic chemists to define and specify the structure and properties of the successfully synthesized polymers. The search for new characterization techniques for polymers is essential for the continuation of the development of improved synthesis methods. The application of tandem mass spectrometry for the detailed characterization of synthetic polymers using the soft ionization techniques matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) and electrospray ionization mass spectrometry (ESI‐MS), which became the basic tools in proteomics, has greatly been increased in recent years and is summarized in this perspective. Examples of a variety of homopolymers, such as poly(methyl methacrylate), poly(ethylene glycol), as well as copolymers, e.g. copolyesters, are given. The advanced mass spectrometric techniques described in this review will presumably become one of the basic tools in polymer chemistry in the near future. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
A transmission geometry optical configuration allows for smaller laser spot size to facilitate high‐resolution matrix‐assisted laser/desorption ionization (MALDI) mass spectrometry. This increase in spatial resolution (ie, smaller laser spot size) is often associated with a decrease in analyte signal. MALDI‐2 is a post‐ionization technique, which irradiates ions and neutrals generated in the initial MALDI plume with a second orthogonal laser pulse, and has been shown to improve sensitivity. Herein, we have modified a commercial Orbitrap mass spectrometer to incorporate a transmission geometry MALDI source with MALDI‐2 capabilities to improve sensitivity at higher spatial resolutions.  相似文献   

10.
基质辅助激光解析电离飞行时间质谱(MALDI-TOF-MS)在合成聚合物的表征手段中具有不可替代的优点,可以提供聚合物的质量分布、嵌段长度、端基等信息.但由于合成聚合物的离子化效率通常不佳,因此样品制备是分析成功的关键.从基质、基质添加剂以及混样方式3个方面综述了MALDI-TOF质谱分析合成聚合物样品制备的研究进展.  相似文献   

11.
Addition of silver nitrate to nonpolar hydrocarbon polymer solutions prior to their analysis by laser desorption Fourier transform mass spectrometry is shown to allow efficient silver ion chemical ionization. High-quality mass spectra are thus obtained for polymers, such as polystyrene, polyisoprene, polybutadiene, and polyethylene, that previously failed to yield useful mass spectra using conventional laser desorption. Accurate mass measurement experiments and isotopic ratios verify that the spectra are those of silver-attached oligomer ion distributions. Mass measurement errors for complete oligomer distributions average between 3 and 12 ppm for oligomers with masses between 400 and 6000 D whereas unit mass resolution is maintained throughout the entire spectral range.  相似文献   

12.
Solvent effect is one of the important factors in sample preparation which may affect matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectra of synthetic polymers. MALDI imaging, a useful imaging tool for discovering biomarkers in tissues, is applied here for better comprehension of solvent effect in polymer analysis by MALDI-TOF mass spectrometry. Nylon-6 was chosen as a model polymer for the study of solvent effect. Its MALDI mass spectra in different solvents were performed. MALDI imaging analysis was performed for studying the incorporation of analytes into matrix crystals in different solvent combinations. Specifically, the colocalization of matrix and analyte was obtained through Pearson’s correlation (PC) coefficient analysis of their MALDI images. The results demonstrated that satisfactory spectra were obtained in higher PC value conditions. PC decreased along with an increase in the ratio of poor solvent, which suggested that we should minimize the poor solvent ratio to obtain better MALDI spectra.  相似文献   

13.
This study presents the application of matrix-assisted laser desorption/ionization mass spectrometric imaging (MALDI-MSI) to monitor changes occurring at polymer surfaces. As an example, a poly(styrene) (PS) film was irradiated with ultraviolet (UV) light at 254 nm for different time intervals, while areas of the film were protected from UV light by covering it with an aluminum mask. After the UV treatment, the polymer surface was analyzed by MALDI-MSI. Time-dependent photo-induced cross-linking of the polymer film was observed, and a correlation curve between UV radiation time and area of cross-linking was constructed. This represents the first step towards the surface analysis of polymer components of photoresists and top coatings of cars, and it will also enable a new characterization strategy for combinatorial material research.  相似文献   

14.
The review describes various derivatization approaches employed for the investigation of synthetic polymers by mild ionization mass spectrometry (fast atom and ion bombardment, matrix-assisted laser desorption/ionization, electrospray/ionization). The potentials of chemical methods for modification of end- and side-chain functional groups without the decomposition of molecules are demonstrated. Methods of the preliminary chemical degradation of polymer molecules for the investigation of their microstructure are considered. The possibilities of the chemical modification of polymer surfaces for the identification and quantitative determination of functionalized fragments are shown.  相似文献   

15.
Using a vertical hair-slice section, we compared the components of normal and damaged hair regions using two ionization methods, matrix-assisted laser desorption/ionization and nanoparticle-assisted laser desorption/ionization (Nano-PALDI) mass spectrometry. Nano-PALDI is useful for small-molecule and high spatial resolution (5 μm) analyses due to the lack of noise. Thus, clear images were obtained from thin hair samples. In Nano-PALDI mass spectrometry imaging, cystine and 18-methyleicosanoic acid as endogenous hair components localized in the cuticle and cortex and cuticle of normal hair, respectively. In contrast, both components were absent in damaged hair.  相似文献   

16.
A protocol for the preparation of polymeric samples for time-of-flight matrix-assisted laser desorption ionization mass spectrometry (TOF-MALDI-MS) analysis was developed. Dithranol was identified as a good matrix for polystyrene (PS), and the addition of silver for cationization of molecules was determined to be necessary. Based on this preparative method, low molecular weight samples of other polymers [polyisoprene, polybutadiene, poly(ethylene oxide), poly(methyl methacrylate), and polydimethylsiloxane] were analyzed with molecular weights up to 49 ku. The effects of laser intensity were determined to influence the molecular weight distribution of intact oligomers, most significantly for low molecular weight polymers. Linear and reflectron modes of analysis were evaluated; better signal intensity and resolution were obtained in the reflectron mode. The TOF-MALDI-MS measurements are compared with time-of-flight secondary ion mass spectrometry (TOF-SIMS) and gel permeation chromatography (GPC) for the same polymers. The M n values calculated by TOF-MALDI-MS consistently are higher than values calculated by TOF-SIMS for all classes of polymers with molecular weights up to 8 ku. The molecular weights of the PS calculated from TOF-MALDI-MS are in good agreement with GPC (±10%). The composition of the terminal group on a polymer chain may affect the ion yields. The ion yields of intact oligomers were evaluated as a function of end group composition for both TOF-MALDI-MS and TOF-SIMS. The slight disparity of results between TOF-SIMS and TOF-MALDI-MS for the perfluoroalkyl-terminated PS suggests that the oligomers are desorbed preferentially from the surface in the TOF-SIMS analysis, rather than having an increased ionization probability.  相似文献   

17.
A novel matrix substance, 2-(4-hydroxyphenylazo) benzoic acid, or HABA, has been found to be very advantageous for matrix-assisted ultraviolet laser desorption ionization mass spectrometry. This compound has been successfully used for the desorption of peptides, proteins, and glycoproteins up to approximately 250 kDa. For these materials, the most abundant analyte-related peaks correspond to [M + H]+ ions and multiply protonated molecules. Comparisons with sinapic acid, 2,5-dihydroxybenzoic acid, and α-cyano-4-hydroxycinnamic acid indicate that the new matrix provides comparable sensitivity for peptides and smaller proteins but results in better sensitivity for larger proteins and glycoproteins in protein mixtures. Other matrices discriminate against the higher mass components in these cases. Somewhat reduced mass resolution has been found for smaller proteins, but for larger proteins and glycoproteins the best mass resolution can often be obtained with the new matrix. For other classes of compounds that form ions predominantly via cation attachment, at least as good sensitivity and even better resolution have been obtained. Derivatized glycolipids and synthetic polymers have been studied in detail. For the analysis of many synthetic polymers, the best performance in terms of sensitivity and mass resolution has been observed with HABA matrix. Mass resolution was higher for cation adducts than for the protonated peptide molecules in the same mass range. The new matrix exhibits greatly extended (in time) analyte ion production and reproducibility. Owing to the uniform sample surface with this matrix, barely any spatial variation of the ion signal could be observed. In addition, many hundreds of single-shot mass spectra could be accumulated from the same spot, even for larger proteins.  相似文献   

18.
Imaging mass spectrometry provides both chemical information and the spatial distribution of each analyte detected. Here it is demonstrated how imaging mass spectrometry of tissue at subcellular resolution can be achieved by combining the high spatial resolution of secondary ion mass spectrometry (SIMS) with the sample preparation protocols of matrix-assisted laser desorption/ionization (MALDI). Despite mechanistic differences and sampling 10(5) times less material, matrix-enhanced (ME)-SIMS of tissue samples yields similar results to MALDI (up to m/z 2500), in agreement with previous studies on standard compounds. In this regard ME-SIMS represents an attractive alternative to polyatomic primary ions for increasing the molecular ion yield. ME-SIMS of whole organs and thin sections of the cerebral ganglia of Lymnaea stagnalis demonstrate the advantages of ME-SIMS for chemical imaging mass spectrometry. Subcellular distributions of cellular analytes are clearly obtained, and the matrix provides an in situ height map of the tissue, allowing the user to identify rapidly regions prone to topographical artifacts and to deconvolute topographical losses in mass resolution and signal-to-noise ratio.  相似文献   

19.
Thin-layer chromatography (TLC) and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) were combined to achieve characterization of polyether mixtures. Three polyethers, polyethylene glycol (PEG), polypropylene glycol (PPG) and polytetramethylene glycol (PTMG), or mixtures of these compounds, were studied. One shortcoming of mixture analysis of synthetic polymers using MALDI-MS is that individual polymers in the mixture may display different detection sensitivities. For example, the MALDI mass spectrum of an equimolar mixture of PEG, PPG and PTMG displayed a high intensity of PPG ions, while no PTMG ions were detectable; however, PTMG ions were detected after the mixture had been separated by TLC. This combined TLC and MALDI-MS analysis of a PPG polymer bearing reactive epoxy groups showed that the polymer contained byproducts with different end-groups. These byproducts were identified as chloro-substituted polymers formed during polymer synthesis. Our study shows TLC to be a rapid and low-cost separation technique, and that it can be combined with MALDI-MS to achieve effective analysis of synthetic polymers.  相似文献   

20.
The use of mass spectrometry (MS) to acquire molecular images of biological tissues and other substrates has developed into an indispensable analytical tool over the past 25 years. Imaging mass spectrometry technologies are widely used today to study the in situ spatial distributions for a variety of analytes. Early MS images were acquired using secondary ion mass spectrometry and matrix-assisted laser desorption/ionization. Researchers have also designed and developed other ionization techniques in recent years to probe surfaces and generate MS images, including desorption electrospray ionization (DESI), nanoDESI, laser ablation electrospray ionization, and infrared matrix-assisted laser desorption electrospray ionization. Investigators now have a plethora of ionization techniques to select from when performing imaging mass spectrometry experiments. This brief perspective will highlight the utility and relative figures of merit of these techniques within the context of their use in imaging mass spectrometry.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号