首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
A review on the use of membranes for on-line sample preparation prior to chromatographic and electrophoretic analysis is provided. The current state-of-the-art of four membrane-based techniques (dialysis, electrodialysis, filtration and membrane extraction) is described by reviewing their principles and applications. Possible future developments are discussed.  相似文献   

2.
Immuno-based sample preparation for trace analysis   总被引:4,自引:0,他引:4  
Immuno-based sample preparation techniques are based upon molecular recognition. Thanks to the high affinity and high selectivity of the antigen–antibody interaction, they have been shown to be a unique tool in the sampling area. Immuno-based sample preparation methods include the widely encountered immunoaffinity extraction sorbents, so-called immunosorbents, as well as membrane-based or ultrafiltration techniques. This review describes the new developments and applications that have occurred in recent years with emphasis on (i) the antigen–antibody interactions, (ii) and their importance for the properties and use of immunosorbents, (iii) multiresidue extractions, (iv) the on-line coupling to chromatographic or electrophoretic separations, and (v) the high potential for improving MS detection. The recent use of artificial antibodies for sample pretreatment, so-called molecularly imprinted polymers, is also described.  相似文献   

3.
Desmosines are crosslinking amino acids unique to mature elastin in humans. Owing to this unicity, they have been discussed as potentially attractive indicators of connective tissue disorders whose clinical manifestations are mostly the result of elastin degradation. This review covers advances in immunochemical, chromatographic, and electrophoretic procedures applied in the last 25 years to detect and quantitate these crosslinksin a variety of biological samples. Recent applications of CE with LIF detection (CE-LIF) for investigating the content of desmosines in different fluids will also be discussed.  相似文献   

4.
Ion migration in electrophoresis always leads to the formation of ionic boundaries. While some types of the ionic boundaries can be formed intentionally, e.g., to improve separation efficiency or sensitivity of the analysis, other, naturally formed boundaries, may cause unexpected effects during the electrophoretic experiment. Some of the boundaries often go unnoticed in practice; however, many effects of the ionic boundaries formed by the sample matrix and background electrolyte components are frequently observed in capillary electrophoresis (CE). The interpretation of these effects may not be trivial and different explanations of the same phenomena may be found in the literature. This critical article attempts to review some of the important effects of the ionic boundaries observed or utilized during the CE of biologically important samples.  相似文献   

5.
Breadmore MC  Haddad PR 《Electrophoresis》2001,22(12):2464-2489
One of the major problems facing the development of capillary electrophoresis (CE) is the relatively high limits of detection when compared to traditional high-performance liquid chromatographic (HPLC) methods. While the use of an alternative detector can offer better sensitivity, a more universal approach is sample preconcentration. Numerous on-line methods have been developed to improve the sensitivity of CE, and are based on electrophoretic principles, chromatographic principles, or a combination of both. This review will discuss all forms of on-line preconcentration methods for CE, with emphasis given to those that have shown particular merit when applied to inorganic and small organic anions.  相似文献   

6.
Organic acids in cerebrospinal fluid (CSF) are potential diagnostic markers for neurological diseases and metabolic disorders. A capillary electrophoretic (CE) method for the direct analysis, i.e., without any sample preparation, of six organic acids in CSF was developed. A capillary coating consisting of a triple layer of charged polymers (polybrene-dextran sulfate-polybrene) was used in combination with a negative separation voltage, providing fast and efficient analysis of acidic compounds. Separation conditions, such as background electrolyte (BGE) concentration and pH were optimized, and the influence of albumin and sodium chloride was systematically studied using a set of test compounds. With injection volumes of ca. 44 nL, plate numbers of up to ca. 150,000 were obtained with a BGE of 200 mM sodium phosphate (pH 6.0). It appeared that high sodium chloride concentrations in the sample hardly affected the peak width and shape of the organic acids, most probably due to transient isotachophoresis effects occurring in the sample zone. Adverse effects of CSF proteins, which frequently compromise the CE performance, could be effectively minimized by the triple layer coating in combination with rinses of 0.1 M hydrochloric acid. Overall, the developed CE system allowed direct injections of CSF samples, yielding good separation efficiencies and stable migration times (RSDs < 2%) for organic acids. Validation of the method with artificial and real CSF samples showed good linear responses (r > 0.99), and LODs for the organic acids were in the range of 2–8 μg/mL when applying UV detection. RSDs for migration times and peak areas were <2% and <7%, respectively. The applicability of the CE system is shown for the determination of organic acids in CSF samples.  相似文献   

7.
Validated liquid chromatography/tandem mass spectrometric (LC/MS/MS) methods are now widely used for quantitation of drugs in post-dose (incurred) biological samples for the assessment of pharmacokinetic parameters, bioavailability and bioequivalence. In accordance with the practice currently accepted within the pharmaceutical industry and the regulatory bodies, validation of a bioanalytical LC/MS/MS method is performed using standards and quality control (QC) samples prepared by spiking the drug (the analyte) into the appropriate blank biological matrix (e.g. human plasma). The method is then declared to be adequately validated for analyzing incurred biological samples. However, unlike QC samples, incurred samples may contain an epimer or another type of isomer of the drug, such as a Z or E isomer. Such a metabolite will obviously interfere with the selected reaction monitoring (SRM) transition used for the quantitation of the drug. The incurred sample may also contain a non-isomeric metabolite having a molecular mass different from that of the drug (such an acylglucuronide metabolite) that can still contribute to (and hence interfere with) the SRM transition used for the quantitation of the drug. The potential for the SRM interference increases with the use of LC/MS/MS bioanalytical methods with very short run times (e.g. 0.5 min). In addition, a metabolite can potentially undergo degradation or conversion to revert back to the drug during the multiple steps of sample preparation that precede the introduction of the processed sample into the LC/MS/MS system. In this paper, we recommend a set of procedures to undertake with incurred samples, as soon as such samples are available, in order to establish the validity of an LC/MS/MS method for analyzing real-life samples. First, it is recommended that the stability of incurred samples be investigated 'as is' and after sample preparation. Second, it is recommended that potential SRM interference be investigated by analyzing the incurred samples using the same LC/MS/MS method but with the additional incorporation of the SRM transitions attributable to putative metabolites (multi-SRM method). The metabolites monitored will depend on the expected metabolic products of the drug, which are predictable based on the functional groups present in the chemical structure of the drug. Third, it is recommended that potential SRM interference be further investigated by analyzing the incurred samples using the multi-SRM LC/MS/MS method following the modification of chromatographic conditions to enhance chromatographic separation of the drug from any putative metabolites. We will demonstrate the application of the proposed strategy by using a carboxylic acid containing drug candidate and its acylglucuronide as a putative metabolite. Plasma samples from the first-in-man (FIM) study of the drug candidate were used as the incurred samples.  相似文献   

8.
《Electrophoresis》2018,39(19):2425-2430
Determination of natural preservatives using electrophoretic or chromatographic techniques in fermented milk products is a complex task due to the following reasons: (i) the concentrations of the analytes can be below the detection limits, (ii) complex matrix and comigrating/coeluting compounds in the sample can interfere with the analytes of the interest, (iii) low recovery of the analytes, and (iv) the necessity of complex sample preparation. The aim of this study was to apply capillary zone electrophoresis coupled with contactless conductivity detection for the separation and determination of nisin in fermented milk products. In this work, separation and determination of natural preservative–nisin in fermented milk products is described. Optimized conditions using capillary zone electrophoresis coupled with capacitance‐to‐digital technology based contactless conductivity detector and data conditioning, which filter the noise of the electropherogram adaptively to the peak migration time, allowed precise, accurate, sensitive (limit of quantification: 0.02 μg/mL), and most importantly requiring very minute sample preparation, determination of nisin. Sample preparation includes following steps: (i) extraction/dilution and (ii) centrifugation. This method was applied for the determination of nisin in real samples, i.e. fermented milk products. The values of different nisin forms were ranging from 0.056 ± 0.003 μg/mL to 9.307 ± 0.437 μg/g.  相似文献   

9.
Pucci V  Raggi MA 《Electrophoresis》2005,26(4-5):767-782
An overview of the electrokinetic chromatographic methods for the analysis of antiepileptic drug levels in biological samples is presented. In particular, micellar electrokinetic capillary chromatography is a very suitable method for the determination of these drugs, because it allows a rapid, selective, and accurate analysis. In addition to the electrokinetic chromatographic studies on the determination of antiepileptic drugs, some information regarding sample pretreatment will also be reported: this is a critical step when the analysis of biological fluids is concerned. The electrokinetic chromatographic methods for the determination of recent antiepileptic drugs (e.g., lamotrigine, levetiracetam) and classical anticonvulsants (e.g., carbamazepine, phenytoin, ethosuximide, valproic acid) will be discussed in depth, and their pharmacological profiles will be briefly described as well.  相似文献   

10.
The use of membrane-based sample preparation techniques in analytical chemistry has gained growing attention from the scientific community since the development of miniaturized sample preparation procedures in the 1990s. The use of membranes makes the microextraction procedures more stable, allowing the determination of analytes in complex and “dirty” samples. This review describes some characteristics of classical membrane-based microextraction techniques (membrane-protected solid-phase microextraction, hollow-fiber liquid-phase microextraction and hollow-fiber renewal liquid membrane) as well as some alternative configurations (thin film and electromembrane extraction) used successfully for the determination of different analytes in a large variety of matrices, some critical points regarding each technique are highlighted.  相似文献   

11.
The present review deals with prefractionation protocols used in proteomic investigation in preparation for mass spectrometry (MS) or two-dimensional electrophoresis (2-DE) map analysis. Briefly, reported methods focus on cell organelle differential centrifugation and on chromatographic approaches, to continue in extenso with a panoply of electrophoretic methods. In the case of chromatography, procedures useful as a prefractionation step, including affinity, ion-exchange, and reversed-phase resins, revealed several hundreds of new species, previously undetected in unfractionated samples. Novel chromatographic prefractionation methods are also discussed such as a multistaged fractionation column, consisting in a set of immobilized chemistries, serially connected in a stack format (an assembly of seven blocks), each capable of harvesting a given protein population. Such a method significantly simplifies the complexity of treated samples while concentrating species, all resulting in a larger number of visible proteins by MS or 2-DE. Electrophoretic prefractionation protocols include all those electrokinetic methodologies which are performed in free solution, essentially all relying on isoelectric focusing steps (although some approaches based on gels and granulated media are also discussed). Devices associated with electrophoretic separation are multichamber apparatus, such as the multicompartment electrolyzers equipped with either isoelectric membranes or with isoelectric beads. Multicup device electrophoresis and several others, exploiting the conventional technique of carrier ampholyte focusing, are reviewed. This review also reports approaches for sample treatments in order to detect low-abundance species. Among others, a special emphasis is made on the reduction of concentration difference between proteins constituting a sample. This latter consists in a library of combinatorial ligands coupled to small beads. Such a library comprises hexameric ligands composed of 20 amino acids, resulting in millions of different structures. When these beads are impregnated with complex proteomes (e.g., human sera) of widely differing protein compositions, they are able to significantly reduce the concentration differences, thus greatly enhancing the possibility to evidence low-abundance species. It is felt that this panoply of methods could offer a strong step forward in "mining below the tip of the iceberg" for detecting the "unseen proteome".  相似文献   

12.
On-line preconcentration methods for capillary electrophoresis   总被引:3,自引:0,他引:3  
Osbourn DM  Weiss DJ  Lunte CE 《Electrophoresis》2000,21(14):2768-2779
The limits of detection (LOD) for capillary electrophoresis (CE) are constrained by the dimensions of the capillary. For example, the small volume of the capillary limits the total volume of sample that can be injected into the capillary. In addition, the reduced pathlength hinders common optical detection methods such as UV detection. Many different techniques have been developed to improve the LOD for CE. In general these techniques are designed to compress analyte bands within the capillary, thereby increasing the volume of sample that can be injected without loss of CE efficiency. This on-line sample preconcentration, generally referred to as stacking, is based on either the manipulation of differences in the electrophoretic mobility of analytes at the boundary of two buffers with differing resistivities or the partitioning of analytes into a stationary or pseudostationary phase. This article will discuss a number of different techniques, including field-amplified sample stacking, large-volume sample stacking, pH-mediated sample stacking, on-column isotachophoresis, chromatographic preconcentration, sample stacking for micellar electrokinetic chromatography, and sweeping.  相似文献   

13.
It is well known that poor quantitative reproducibility substantially limits the practical implementation of capillary electrophoresis (CE) separations in chemical analysis. The principal sources of variance in observed peak areas are irreproducible flow rate, which influences on-column detector response, and inconsistent injection volume or amount. An overview of studies by researchers to address the reproducibility issue will be presented. In addition, current efforts in our laboratory to assess sources of quantitative variance for separations of dansylated amino acids using an automated CE system are presented and related when appropriate to the body of existing knowledge on this important topic. A comparison of different injection methods (hydrostatic vs. electrokinetic) and approaches (e.g., high vs. low pressure), the effect of random changes in electroosmotic flow (EOF) due to air bubbles in the CE capillary, and choice of certain peak integration parameters in terms of peak area reproducibility are presented. Under optimum conditions relative standard deviation (RSD) values in raw peak area are typically 2.0%. With nonoptimum conditions (e.g., with air bubbles in capillary), RSD values can substantially degrade. However, normalizing with retention times, internal standards, or observed electrophoretic current produces RSD values in a range of 1.4-2.3%.  相似文献   

14.
The present review highlights some modern aspects of biosensor revelation, a detection method which has already found a large number of applications in healthcare, food industry and environmental analysis. First, the concept of bio-recognition, which is at the heart of biosensor technology, is discussed, with emphasis on host-guest-like recognition mechanisms. This detection device has been successfully coupled, in its first applications, to chromatographic columns, which allow a high resolution of complex mixtures of analytes prior to interaction with the biosensing unit. The properties of the transducing elements, which should generate a signal (e.g., electrochemical, thermal, acoustic, optical) of proper intensity and of relative fast rise, are additionally evaluated and discussed. The review then focuses on potential applications of biosensing units in capillary electrophoresis (CE) devices. CE appears to be an excellent separation methodology to be coupled to biosensor detection, since it is based on miniaturized electrophoretic chambers, fast analysis times, complete automation in sample handling and data treatment and requires extremely small sample volumes. Although only a few applications of CE-based biosensors have been described up to the present, it is anticipated that this hyphenated technique could have a considerable expansion in the coming years.  相似文献   

15.
Dolník V 《Electrophoresis》2006,27(1):126-141
This review article with 304 references describes recent developments in CE of proteins, and covers the two years since the previous review (Hutterer, K., Dolník, V., Electrophoresis 2003, 24, 3998-4012) through Spring 2005. It covers topics related to CE of proteins, including modeling of the electrophoretic migration of proteins, sample pretreatment, wall coatings, improving separation, various forms of detection, special electrophoretic techniques such as affinity CE, CIEF, and applications of CE to the analysis of proteins in real-world samples including human body fluids, food and agricultural samples, protein pharmaceuticals, and recombinant protein preparations.  相似文献   

16.
The quality of sample preparation is a key factor in determining the success of analysis. While analysis of pharmaceutically important compounds in biological matrixes has driven forward the development of sample clean-up procedures in last 20 years, today's chemists face an additional challenge: sample preparation and analysis of complex biochemical samples for characterization of genotypic or phenotypic information contained in DNA and proteins. This review focuses on various sample pretreatment methods designed to meet the requirements for the analysis of biopolymers and small drugs in complex matrices. We discuss the advances in development of solid-phase extraction (SPE) sorbents, on-line SPE, membrane-based sample preparation, and sample clean-up of biopolymers prior to their analysis by mass spectrometry.  相似文献   

17.
The aim of this study was to develop and evaluate a capillary zone electrophoretic (CE) procedure for the accurate quantification of the UDP-hexosamines as well as for the corresponding UDP-hexoses in samples from various biological origins. Testing different buffer conditions, voltages, capillary dimensions and temperatures, optimal results were achieved with a 90 mM borate buffer, pH 9.0, at 18 degrees C and 15.5 kV in an uncoated fused-silica capillary of 50 cm x 50 microm and a detection wavelength of lambda = 262 nm. The total procedure, i.e., including variations of the sample preparation, showed coefficients of variation for the peak areas between 4. 1% and 10.4% in mesangial cells (n = 7) and between 7.8 and 10.3% (n = 6) in leukocytes for the components of interest. To improve precision, an internal standard was used for calibration. The limit of detection for all compounds is an absolute amount of 180 fmol, sufficient for the precise analysis of UDP-sugars in a limited amount of biological samples, such as human leukocytes (obtained from a 10 mL blood sample), muscle biopsies (< or = 100 mg), and mesangial kidney cells (ca. 2.5 x 10(5) cells). This reproducible, quantitative analysis of all four UDP-sugars from various biomedically relevant origins by CZE is a definite improvement over the generally used high performance liquid chromatography (HPLC) procedures. The CZE method allows the study of the flux through the hexosamine pathway in diabetes mellitus and other diseases in a simple, quantitative and accurate way.  相似文献   

18.
Preconcentration procedures based on ion-exchange methods are often used to enhance the sensitivities of analytical techniques where the eluent used for eluting the preconcentrated ions does not influence the subsequent analytical step. Until recently, only a limited use of ion-exchange-based sample preconcentration procedures has been found in those analytical techniques where the eluent components strongly influence the separation procedure [e.g., capillary electrophoresis (CE)]. In this paper, we present a preconcentration procedure based on (i) the preconcentration of anions on an ion-exchange resin, (ii) the subsequent elution of analytes, and (iii) on-line removal of eluent components by chemical suppression using an appropriate suppressor device (either packed-bed suppressor column or micromembrane suppressor). The adjustment of the system parameters, combined with a computer-controlled, sensing/switching system, resulted in a minimal additional dilution of the eluted preconcentrated anions. The efficiency of the proposed enrichment/matrix removal procedure was tested by using off-line CE analysis of collected preconcentrated samples, reaching a LOD of 1 microg/l for a selected anion.  相似文献   

19.
Ge L  Tan S  Yong JW  Tan SN 《Electrophoresis》2006,27(23):4779-4791
Analyses of cytokinins are very important in both plant physiological and biomedical research as they are implicated in many biological processes. Reliable, sensitive, selective and inexpensive methods that are flexible and designed for automation are required for these analyses. This review addresses the advances made in the separation and determination of cytokinins by CE as well as the other applications of CE (i.e., determination of dissociation constants and complexation constants of cytokinins). The various CE modes used to separate the compounds and the quantification strategies are examined. Special attention is also focused on those aspects that improve on the sensitivity and/or selectivity, such as sample extraction and preconcentration, on-line preconcentration techniques (stacking), and/or specific detectors (e.g., MS). With the coupling to the preconcentration techniques and certain detection systems, numerous CE methods can potentially be adapted for the analysis of cytokinins in complex biological samples. Therefore, we would anticipate wider applications of CE methods in the near future for cytokinin analyses, which should facilitate a decrease in analysis cost and should help to improve analysis efficiency.  相似文献   

20.
Chen SH  Chen YH 《Electrophoresis》1999,20(15-16):3259-3268
This review briefly discusses the use of capillary electrophoretic (CE) methods for the investigations of different aspects of pharmacokinetics. In most investigations, CE was the method of choice because of its unique features, including high resolving power for chiral or metabolite separation, small sample volume for pediatric pharmacokinetics or for cell-based investigations, in situ microdialysis sampling for rapid eliminations, low UV wavelength detection for nonderivatized analytes, fast and simplified sample processing for existing methods that require tedious sample preparation, or as a second method for verifications. Moreover, instrumental aspects of CE-based assays for pharmacokinetic studies, such as different modes of CE methods for analyzing biological samples, sample stacking for increasing detection sensitivity, and coupling techniques with microdialysis and mass spectrometry, are also discussed in this review. Furthermore, the advantages and limitations of CE methods as well as the future outlook for pharmacokinetic studies are summarized.  相似文献   