首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
A high-performance liquid chromatography–UV method for determining DCJW concentration in rat plasma was developed. The method described was applied to a pharmacokinetics study of intramuscular injection in rats. The plasma samples were deproteinized with acetonitrile in a one-step extraction. The HPLC assay was carried out using a VP-ODS column and the mobile phase consisting of acetonitrile–water (80:20, v/v) was used at a flow rate of 1.0 mL min−1 for the effective eluting DCJW. The detection of the analyte peak area was achieved by setting a UV detector at 314 nm with no interfering plasma peak. The method was fully validated with the following validation parameters: linearity range 0.06–10 μg mL−1 (r > 0.999); absolute recoveries of DCJW were 97.44–103.46% from rat plasma; limit of quantification, 0.06 μg mL−1 and limit of detection, 0.02 μg mL−1. The method was further used to determine the concentration–time profiles of DCJW in the rat plasma following intramuscular injection of DCJW solution at a dose of 1.2 mg kg−1. Maximum plasma concentration (C max) and area under the plasma concentration–time curve (AUC) for DCJW were 140.20 ng mL−1 and 2405.28 ng h mL−1.  相似文献   

2.
A sensitive and selective HPLC–UV method established for determination of picroside I in dog plasma has been used to study the pharmacokinetics of the drug after intravenous administration of three different doses. Sample pretreatment consists in deproteination by addition of acetonitrile; l-ascorbic acid was used to improve the stability of picroside I. The lower limit of quantification of picroside I was 0.05 μg mL−1. The recovery of the method was up to 90%. After intravenous administration to dogs picroside I was mainly distributed in the central compartment and was rapidly eliminated from the plasma; the mean elimination half-life was 30.54 ± 4.34, 30.20 ± 3.78, and 34.02 ± 1.88 min for doses of 2.5, 5, and 15 mg kg−1, respectively, and the respective values of AUC 0–∞ were 81.04 ± 19.95, 198.50 ± 27.77, and 586.44 ± 103.08 μg min mL−1. The different doses had no significant effect on the main pharmacokinetic data and the kinetics seemed to be linear in dosage range 2.5–15 mg kg−1.  相似文献   

3.
Summary The fluorogenic reagent 2-naphthyloxycarbonyl chloride (NOC-Cl) has been used for the automated precolumn derivatization of biogenic amines (BAs) at ambient followed by liquid-chromatographic separation of the derivatives formed. For optimized derivatization samples in 0.5 M borate buffer (pH 9.0) were derivatized with 5 mM NOC-Cl in acetonitrile (MeCN) for 3 minutes. Excess of reagent was scavenged by addition of 20 mM glycine in water. For HPLC a Superspher? RP-18e column and gradient elution using 0.1 M sodium acetate buffer (pH 4.4) and MeCN were used. The NOC-derivatives were detected by fluorescence at an emission wavelength of 335 nm at an excitation wavelength of 274 nm. This method allows the detection of BAs (2-phenylethylamine, putrescine, histamine, cadaverine, tyramine, spermidine, spermine) found in food and beverages (fruit juices, wines, various vinegars, fermented cabbage juice, and salmon). Detection limit of BAs are approximately 49–113 μg kg−1 with the exception of histamine (747 μg kg−1) (injected amounts: 18–41 pg histamine 267 pg), at a signalto-noise ratio of 3:1. The limits of determination are approximately 82–189 μg kg−1 (histamine 1245 μg kg−1) at a signal-to-noise ratio of 5:1. The correlation coefficients of linearity are 0.9910–0.9976. Recoveries from different matrices range from 65 to 109%, depending on the sample investigated. Presented at the 21st ISC held in Stuttgart, Germany, 15th–20th September, 1996.  相似文献   

4.
This paper describes a new and rapid method for accurate quantification of the six ergot alkaloids, ergometrine, ergotamine, ergosine, ergocristine, ergocryptine, and ergocornine, by liquid chromatography–tandem mass spectrometry (LC–MS–MS). The six ergot alkaloids studied have been defined by the European Food Safety Authority (EFSA) as among the most common and physiologically active ones. In addition, the method enables the quantification of the corresponding six epimers (ergo-inines) of these ergot alkaloids. This is of considerable importance in terms of the differences in toxicity of the isomeric forms. The method involves extraction under alkaline conditions using a mixture of acetonitrile and ammonium carbonate buffer followed by a rapid clean-up using dispersive solid-phase extraction with PSA (primary secondary amine) and a short chromatographic LC-run (21 min) with subsequent MS–MS detection. The method was developed and validated using ten different cereal and food samples. The major strength of the new method compared with previously published techniques is the simplicity of the clean-up procedure and the short analysis time. The limits of quantification were 0.17 to 2.78 μg kg−1 depending on the analyte and matrix. Recovery values for the 12 ergot alkaloids spiked into ten different matrices at levels of 5, 50, and 100 μg kg−1 were between 69 and 105% for 85 of 90 recovery measurements made over six days. Measurement uncertainty values were highly satisfactory. At a concentration level of 5 μg kg−1 the expanded measurement uncertainty ranged from ±0.56 to ±1.49 μg kg−1, at a concentration level of 100 μg kg−1 the expanded measurement uncertainty ranged from ±8.9 to ±20 μg kg−1. Both LOQs and measurement uncertainties were dependent on the analyte but almost independent of the matrix. The method performance was satisfactory when tested in a mini-intercomparison study between three laboratories from three different countries. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

5.
A fully automated method has been developed for analysis of eighteen antibacterial compounds, including penicillins, cephalosporins and sulfonamides, in animal feed with limits of quantification in the range 0.25–5.79 μg kg−1. The method is based on pressurized liquid extraction of 3 g homogenized feed with water and online clean-up of 500 μL of the extract with C18HD cartridges. The purified sample was directly analysed by liquid chromatography–electrospray tandem mass spectrometry (SPE–LC–ESI-MS–MS). Chromatographic separation was achieved within 10 min by use of a C12 Phenomenex Hydro-RP reversed-phase analytical column and a mobile phase gradient (water + 0.1% formic acid–methanol + 0.1% formic acid). The method was validated, revealing capability for detection of concentrations as low as 0.09 μg kg−1, decision limits (CCα) and detection capabilities (CCβ) in the range 10–174 μg kg−1 and 22–182 μg kg−1, respectively, and inter-day precision ranging from 0.7 to 8.3%. Recovery, with internal standard correction, was in the range 93–134% for all analytes. The method was then applied to analysis of fifteen feed samples, nine of which contained at least one antimicrobial at concentrations between 0.006 and 1.526 mg kg−1. The performance data and results from the method were compared with those from a previous method developed by our group, using offline SPE, by analyzing the same set of samples by both methods. The online SPE approach resulted in slightly improved sensitivity, with LODs of 0.09–2.12 μg kg−1 compared with 0.12–3.94 μg kg−1 by the offline approach. In general, better recovery was achieved by use of online purification (for 72% of the analytes) and the correlation between the two methods was good. The main advantages of the new online method are rapid and automated sample pre-treatment, and reduction of sample manipulation, enabling high-throughput analysis and highly accurate results. Because of all these characteristics, the proposed method is applicable and could be deemed necessary within the field of food control and safety.  相似文献   

6.
Solid-phase extraction was used to isolate sulfacetamide, sulfathiazole, sulfapyridine, sulfamerazine, sulfamethoxypyridazine and sulfamethoxazole from honey. The optimized procedure used polymeric Abselut Nexus cartridges and the sulfonamides were separated, in the isocratic mode, on an Inertsil ODS-3 (250 × 4 mm I.D., 5 μm) column, using methanol-0.05 M acetate buffer (pH 3.6) (20:80 v/v) with 1% (v/v) of acetic acid, UV detection at 263 nm and a flow-rate of 1 mL min−1. Caffeine was used as internal standard. Average recoveries of the analytes from spiked honey ranged from 80 to 117% and the detection limits based on a spiked honey extract were 20–25 μg kg−1.  相似文献   

7.
A multi-component method focussing on thorough sample preparation has been developed for simultaneous analysis of swine manure for three classes of antibiotic—tetracyclines, sulfonamides, and tylosin. Liquid manure was initially freeze-dried and homogenised by pulverization before extraction by pressurised liquid extraction. The extraction was performed at 75°C and 2,500 psig in three steps using two cycles with 0.2 mol L−1 citric acid buffer (pH 4.7) and one cycle with a mixture of 80% methanol with 0.2 mol L−1 citric acid (pH 3). After liquid–liquid extraction with heptane to remove lipids, the pH of the manure was adjusted to 3 with formic acid and the sample was vacuum-filtered through 0.6 μm glass-fibre filters. Finally the samples were pre-concentrated by tandem SPE (SAX-HLB). Recoveries were determined for manure samples spiked at three concentrations (50–5,000 μg kg−1 dry matter); quantification was achieved by matrix-matched calibration. Recoveries were >70% except for oxytetracycline (42–54%), sulfadiazine (59–73%), and tylosin (9–35%) and did not vary with concentration or from day-to-day. Limits of quantification (LOQ) for all compounds, determined as a signal-to-noise ratio of 10, were in the range 10–100 μg kg−1 dry matter. The suitability of the method was assessed by analysis of swine manure samples from six different pig-production sites, e.g. finishing pigs, sows, or mixed production. Residues of antibiotics were detected in all samples. The largest amounts were found for tetracyclines (up to 30 mg kg−1 dry matter for the sum of CTC and ECTC). Sulfonamides were detected at concentrations up to 2 mg kg−1 dry matter (SDZ); tylosin was not detected in any samples.   相似文献   

8.
This paper reports a novel approach for the detection, confirmation, and quantification of 15 selected pyrethroid pesticides, including pyrethins, and two metabolites of dithiocarbamates in foods by ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS–MS). The proposed method makes use of a modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) procedure that combines isolation of the pesticides and sample cleanup in a single step. Analysis of pyrethroids and dithiocarbamate metabolites was performed by UPLC–MS–MS operated with electrospray and atmospheric pressure chemical ionization, respectively. Two specific precursor–product ion transitions were acquired per target compound in multiple reaction monitoring (MRM) mode. Such acquisition achieved the minimum number of identification points according to European Commission (EC) document no. SANCO/10684/2009, thus fulfilling the EC point system requirement for identification of contaminants in samples. The method was validated with a variety of food samples. Calibration curves were linear and covered from 1 to 800 μg kg−1 in the sample for all target compounds. Average recoveries, measured at mass fractions of 10 and 100 μg kg−1 for pyrethroids and 5 and 50 μg kg−1 for dithiocarbamate metabolites, were in the range of 70–120% for all target compounds with relative standard deviations below 20%. Method limits of quantification (MLOQ) were 10 μg kg−1 and 5 μg kg−1 for pyrethroids and dithiocarbamate metabolites, respectively. The method has been successfully applied to the analysis of 600 food samples in the course of the first Hong Kong total diet study with pyrethroids and metabolites of dithiocarbamates being the pesticides determined.  相似文献   

9.
An optimized extraction and cleanup method for the analysis of chlortetracycline (CTC), doxycycline (DC), oxytetracycline (OTC) and tetracycline (TC) in soil is presented. Soil extraction in a pressurized liquid extraction system, followed by extract clean up using solid-phase extraction (SPE) and tetracycline determination by liquid chromatography tandem mass spectrometry (LC-MS/MS) provided appropriate efficiency and reproducibility. Different dispersing agents and solvents for soil extraction and several SPE cartridges for cleanup were compared. The best extraction results were obtained using ethylenediamine tetraacetic acid-treated sand as dispersing agent, and water at 70 °C. The most effective cleanup was obtained using Strata-XTM sorbent in combination with a strong anion exchange cartridge. Recoveries ranged from 71% to 96% and precision, as indicated by the relative standard deviations, was within the range of 8–15%. The limits of quantification (LOQs) by using LC-MS/MS, based on signal-to-noise ratio (S/N) of 10, ranged from 1 μg kg−1 for TC to 5 μg kg−1 for CTC. These results pointed out that this technique is appropriate to determine tetracyclines in soils. Analysis of 100 samples taken in the Valencian Community revealed that, in soil, up to 5 μg kg−1 CTC, 15 μg kg−1 OTC, 18 μg kg−1 TC, and 12 μg kg−1 DC could be detected. Detection of the analytes in several samples, which typify great part of the Spanish agricultural soils, should be outlined as most important result of this study. Electronic supplementary material  The online version of this article (doi: ) contains supplementary material, which is available to authorized users.  相似文献   

10.
A simple, rapid, and precise reversed-phase high-performance liquid chromatographic method has been developed for simultaneous determination of losartan potassium, ramipril, and hydrochlorothiazide. The three drugs were separated on a 150 mm × 4.6 mm i.d., 5 μm particle, Cosmosil C18 column. The mobile phase was 0.025 m sodium perchlorate–acetonitrile, 62:38 (v/v), containing 0.1% heptanesulphonic acid, pH adjusted to 2.85 with orthophosphoric acid, at a flow rate of 1.0 mL min−1. UV detection was performed at 215 nm. The method was validated for linearity, accuracy, precision, and limit of quantitation. Linearity, accuracy, and precision were acceptable in the ranges 35–65 μg mL−1 for losartan, 1.75–3.25 μg mL−1 for ramipril, and 8.75–16.25 μg mL−1 for hydrochlorothiazide.  相似文献   

11.
The analysis of four nitrofuran veterinary drugs, nitrofurantoin, furazolidone, furaltadone and nitrofurazone, was optimized using reversed-phase liquid chromatography with a monolithic column and photo-diode array detection. The antibiotics were extracted from animal feeds by heating with acetonitrile. The isocratic mobile phase consisted of a 8:92 (v/v) acetonitrile/phosphate buffer (pH 4.5) at a flow-rate of 1 mL min−1. Peaks were identified by the retention characteristics and UV spectra. Detection limits in the water samples ranged between 0.21 and 0.27 μg L−1, and in the feed samples between 2.1 and 2.7 μg kg−1, depending on the nitrofuran. The procedure was applied to the control of nitrofuran residues in farm water for poultry and different animal feeds.  相似文献   

12.
A new marine sediment certified reference material, NMIJ CRM 7306-a, for butyltin and phenyltin analysis has been prepared and certified by the National Metrological Institute of Japan at the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). Candidate sediment material was collected at a bay near industrial activity in Japan. After air-drying, sieving, and mixing the material was sterilized with γ-ray irradiation. The material was re-mixed and packaged into 250 glass bottles (15 g each) and these were stored in a freezer at −30 °C. Certification was performed by use of three different types of species-specific isotope-dilution mass spectrometry (SSID–MS)—SSID–GC–ICP–MS, SSID–GC–MS, and SSID–LC–ICP–MS, with 118Sn-enriched organotin compounds synthesized from 118Sn-enriched metal used as a spike. The 118Sn-enriched mono-butyltin (MBT), dibutyltin (DBT), and tributyltin (TBT) were synthesized as a mixture whereas the 118Sn-enriched di-phenyltin (DPhT) and triphenyltin (TPhT) were synthesized individually. Four different extraction methods, mechanical shaking, ultrasonic, microwave-assisted, and pressurized liquid extraction, were adopted to avoid possible analytical bias caused by non-quantitative extraction and degradation or inter-conversion of analytes in sample preparations. Tropolone was used as chelating agent in all the extraction methods. Certified values are given for TBT 44±3 μg kg−1 as Sn, DBT 51 ± 2 μg kg−1 as Sn, MBT 67 ± 3 μg kg−1 as Sn, TPhT 6.9 ± 1.2 μg kg−1 as Sn, and DPhT 3.4 ± 1.2 μg kg−1 as Sn. These levels are lower than in other sediment CRMs currently available for analysis of organotin compounds.  相似文献   

13.
A rapid, specific reversed phase HPLC method has been developed for simultaneous determination of olanzapine and fluoxetine in their formulations. Chromatographic separation of these two pharmaceuticals was carried out on an Inertsil C18 reversed phase column (150 mm × 4.6 mm, 5 μm) with a 40:30:30 (v/v/v) mixture of 9.5 mM sodium dihydrogen phosphate (pH adjusted to 6.8 ± 0.1 with triethylamine), acetonitrile and methanol as mobile phase. The flow rate 1.2 mL min−1 and the analytes are monitored at 225 nm. Paroxetine was used as internal standard. The assay results were linear from 25 to 75 μg mL−1 for olanzapine (r 2 ≥ 0.995) and 100–300 μg mL−1 for fluoxetine (r 2 ≥ 0.995), showed intra- and inter-day precision less than 1.0%, and accuracy of 97.7–99.1% and 97.9–99.0%. LOQ was 0.005 and 0.001 μg mL−1 for olanzapine and fluoxetine, respectively. Separation was complete in less than 10 min. Validation of the method showed it to be robust, precise, accurate and linear over the range of analysis.  相似文献   

14.
A novel method was developed for the determination of captan, folpet, and captafol in apples by dispersive liquid–liquid microextraction (DLLME) coupled with gas chromatography–electron capture detection (GC–ECD). Some experimental parameters that influence the extraction efficiency, such as the type and volume of the disperser solvents and extraction solvents, extraction time, and addition of salt, were studied and optimized to obtain the best extraction results. Under the optimum conditions, high enrichment factors for the compounds were achieved ranging from 824 to 912. The recoveries of fungicides in apples at spiking levels of 20.0 μg kg−1 and 70.0 μg kg−1 were 93.0–109.5% and 95.4–107.7%, respectively. The relative standard deviations (RSDs) for the apple samples at 30.0 μg kg−1 of each fungicide were in the range from 3.8 to 4.9%. The limits of detection were between 3.0 and 8.0 μg kg−1. The linearity of the method ranged from 10 to 100 μg kg−1 for the three fungicides, with correlation coefficients (r 2) varying from 0.9982 to 0.9997. The obtained results show that the DLLME combined with GC–ECD can satisfy the requirements for the determination of fungicides in apple samples. Figure Dispersive liquid–liquid microextraction (DLLME) coupled with gas chromatography–electron capture detection (GC–ECD) allows satisfactory determination of fungicides in apple samples  相似文献   

15.
Metabolism of four tobacco-specific N-nitrosamines (TSNAs), N′-nitrosonornicotine (NNN), N′-nitrosoanatabine (NAT), N′-nitrosoanabasine (NAB), and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) has been studied by solid-phase extraction (SPE) and liquid chromatography–tandem mass spectrometry (LC–MS–MS). 4-(Methylnitrosamino)-4-(3-pyridyl)-1-butanol (iso-NNAL) was used as internal standard. SPE and LC–MS–MS was found to be a rapid, simple, sensitive, and selective method for analysis of TSNAs in rabbit serum. The relative standard deviation (R.S.D., n = 6) for analysis of 5 ng mL−1 and 0.5 ng mL−1 standards and of serum sample spiked with 5 ng mL−1 standards of five TSNAs was 2.1–11% and recovery of 5 ng mL−1 standards from serum was 100.2–112.9%. A good linear relationship was obtained between peak area ratio and concentration in the range of 0.2–100 ng mL−1 for NNAL and 0.5–100 ng mL−1 for other four TSNAs, with correlation coefficients (R 2) >0.99 (both linear and log–log regression). Detection limits for standards in solvent were between 0.04 and 0.10 ng mL−1. Doses of TSNAs administered to rabbits via the auricular vein were 4.67 μg kg−1 and 11.67 μg kg−1, in accordance with the different levels in cigarettes. Metabolic curves were obtained for the four TSNAs and for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), a metabolite of NNK; on the basis of these curves we modeled metabolic kinetic equations for these TSNAs by nonlinear curve fitting.  相似文献   

16.
A sensitive and effective method for simultaneous determination of triazolopyrimidine sulfonamide herbicide residues in soil, water, and wheat was developed using ultra-performance liquid chromatography coupled with tandem mass spectrometry. The four herbicides (pyroxsulam, flumetsulam, metosulam, and diclosulam) were cleaned up with an off-line C18 SPE cartridge and detected by tandem mass spectrometry using an electrospray ionization source in positive mode (ESI+). The determination of the target compounds was achieved in <2.0 min. The limits of detection were below 1 μg kg−1, while the limits of quantification did not exceed 3 μg kg−1 in different matrices. Quantitation was determined from calibration curves of standards containing 0.05–100 μg L−1 with r 2 > 0.997. Recovery studies were conducted at three spiked levels (0.2, 1, and 5 μg kg−1 for water; 5, 10, and 100 μg kg−1 for soil and wheat). The overall average recoveries for this method in water, soil, wheat plants, and seeds at three levels ranged from 75.4% to 106.0%, with relative standard deviations in the range of 2.1–12.5% (n = 5) for all analytes.  相似文献   

17.
Fumonisins B1 (FB1) and fumonisin B2 (FB2) are the main members of a family of mycotoxins produced by Fusarium verticillioides, Fusarium proliferatum, and other fungi species of the section Liseola. The present work shows the results of comparative studies using two different procedures for the analysis of fumonisins in maize and maize-based samples. The studied analytical methods involve extraction with methanol/water, dilution with PBS, and clean-up through immunoaffinity columns. Two reagents (o-phthaldialdehyde and naphthalene-2,3-dicarboxaldehyde) were studied for formation of fluorescent derivatives. The separation and identification were carried out by high-performance liquid chromatography with fluorescence detection. The optimized method for analysis of fumonisins in maize involved extraction with methanol/water (80:20), clean-up with an immunoaffinity column, and derivatization with naphthalene-2,3-dicarboxaldehyde (NDA). The limit of detection was 20 μg kg−1 for FB1 and 15 μg kg−1 for FB2. Recoveries of FB1 and FB2 ranged from 79% to 99.6% for maize fortified at 150 μg kg−1 and 200 μg kg−1, respectively, with within-day RSDs of 3.0 and 2.7%. The proposed method was applied to 31 samples, and the presence of fumonisins was found in 14 samples at concentrations ranging from 113 to 2,026 μg kg−1. The estimated daily intake of fumonisins was 0.14 μg kg−1 body weight per day.  相似文献   

18.
Methylmercury (MeHg) and total mercury (THg) in seafood were determined using species-specific isotope dilution analysis and gas chromatography combined with inductively coupled plasma mass spectrometry. Sample preparation methods (extraction and derivation step) were evaluated on certified reference materials using isotopically enriched Hg species. Solid–liquid extraction, derivation by propylation and automated agitation gave excellent accuracy and precision results. Satisfactory figures of merit for the selected method were obtained in terms of limit of quantification (1.2 μg Hg kg−1 for MeHg and 1.4 μg Hg kg−1 for THg), repeatability (1.3–1.7%), intermediate precision reproducibility (1.5% for MeHg and 2.2% for THg) and trueness (bias error less than 7%). By means of a recent strategy based on accuracy profiles (β-expectation tolerance intervals), the selected method was successfully validated in the range of approximately 0.15–5.1 mg kg−1 for MeHg and 0.27–5.2 mg kg−1 for THg. Probability β was set to 95% and the acceptability limits to ±15%. The method was then applied to 62 seafood samples representative of consumption in the French population. The MeHg concentrations were generally low (1.9–588 μg kg−1), and the percentage of MeHg varied from 28% to 98% in shellfish and from 84% to 97% in fish. For all real samples tested, methylation and demethylation reactions were not significant, except in one oyster sample. The method presented here could be used for monitoring food contamination by MeHg and inorganic Hg in the future to more accurately assess human exposure.  相似文献   

19.
Analytical methods used for the isotope dilution inductively coupled plasma mass spectrometric (ID-ICP-MS) measurement of Cd at μg kg−1 and sub-μg kg−1 levels are described and applied to the certification of new dietary supplement, blood, and serum Standard Reference Materials (SRMs). The materials are: SRM 3240 Ephedra sinica Stapf Aerial Parts, SRM 3241 Ephedra sinica Stapf Native Extract, SRM 3243 Ephedra-Containing Solid Oral Dosage Form, SRM 3244 Ephedra-Containing Protein Powder, SRM 966 Toxic Metals in Bovine Blood, Level 1 (L1) and Level 2 (L2), and SRM 1598a Animal Serum. The concentration of Cd in the materials ranges from 120 μg kg−1 down to 0.03 μg kg−1. At these levels, the factors that most influence the accuracy of the ICP-MS data are the procedure blank and spectral and nonspectral interferences. Nonspectral interference, caused by the high concentration of dissolved solids in the matrices investigated, resulted in signal suppression. Matrix separation was used to enhance signal intensity and to reduce spectral interference for the accurate determination of Cd in SRM 1598a and SRM 3244. Chromatographic separation procedures using Chelex for SRM 1598a and anion exchange for SRM 3244 were optimized to achieve the desired separation characteristics without substantially increasing the procedure blank. Sensitivity for the determination of Cd in serum was additionally enhanced through the use of desolvation nebulization. We determined that separations were not required for the accurate ICP-MS determination of Cd in SRM 3240, SRM 3241, SRM 3243, and SRM 966 L2 under optimized analysis conditions. These samples were diluted to a minimum volume and introduced to the ICP-MS via low flow (40–100 μL/min) microconcentric nebulizers. SRM 966 L1 was also analyzed directly, but results were highly variable. The ID-ICP-MS sample preparation and ratio measurement protocols described here resulted in total expanded uncertainties of less than 1% for the determination of 90.85 μg kg−1 Cd in SRM 3240, and less than 10% total expanded uncertainty for the determination of 0.0468 μg kg−1 Cd in SRM 1598a.  相似文献   

20.
Two new HPTLC methods for quantification of isopropyl-9H-thioxanthen-9-one (ITX) in milk, yoghurt and fat samples have been developed. Extraction of ITX from milk and yoghurt was performed with a mixture of cyclohexane and ethyl acetate by employment of accelerated solvent extraction (ASE). For soy bean oil and margarine, a simple partitioning of ITX into acetonitrile was used. ITX and 2,4-diethyl-9H-thioxanthen-9-one (DTX) used as internal standard have been separated on silica gel 60 HPTLC plates with a mixture of toluene and n-hexane (4:1, v/v) and on RP18 HPTLC plates with a mixture of acetonitrile and water (9:1, v/v). Development was performed anti-parallel from both plate sides leading to a throughput of 36 separations in 7 min. Fluorescence measurement at 254/>400 nm was used for quantification. Limits of detection (S/N of 3) have been established to be 64 pg for ITX and DTX on both types of HPTLC plates. In fatty matrix (spiked butter) LOD of ITX was determined to be 1 μg kg−1. In the working range monitored (20–200 μg kg−1) polynomial regression of ITX showed a relative standard deviation (sdv) of ±1.51 % (r=0.99981). Starting with the limit of quantification the response was linear (sdv=±2.18 %, r=0.99893). Regarding repeatability (n=9) a coefficient of variation (CV) of 1.1 % was obtained for ITX at 32 ng on silica gel plates and of 2.9 % on reversed-phase plates. Repeatabilities (n=4) of ITX determination at 20, 50 and 100 μg kg−1 in milk, yoghurt, soybean oil and margarine showed CVs between ±1.0 and 6.4 %. The results prove that modern planar chromatography is a rapid and cost-efficient alternative method to quantify ITX in milk-based or fatty matrices. Only positive results are confirmed by online ESI/MS in the SIM mode (LOQ 128 pg) and by DART/MS involving a minimal employment of the MS device, which is a further advantage of HPTLC. Overall mean recovery rates of ITX at 20 or 50 and 100 μg kg−1 (n=8) were 41 % for milk, 70 % for yoghurt, 6 % for margarine and 12 % for soy bean oil. However, with the internal standard correction recoveries were about 130 % for milk and yoghurt and 70 and 97 % for margarine and soy bean oil, respectively.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号