首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
VO2(B) nanoflowers were synthesized via hydrothermal method, and VO2(M) nanoflowers were obtained through heat‐transformation. Two sensors based on VO2(B) and VO2(M) nanoflowers were fabricated and their humidity characteristics were studied. It was found that these sensors exhibited fast response and recovery, perfect reproducibility and good stability. The VO2(M) type sensor is more sensitive at high RH and can be used for high humidity detection. On the contrary, the VO2(B) type sensor has a higher sensitivity at low RH, and can be used for low humidity detection, which is difficult for humidity sensors based on many other semiconductor oxides.  相似文献   

2.
Flexible pressure sensors have drawn considerable attention for their potential applications as electronic skins with both sensitivity and pressure response range. Although the introduction of surface microstructures effectively enhances sensitivity, the confined volume of their compressible structures results in a limited pressure response range. To address this issue, a biomimetic kapok structure is proposed and implemented for constructing the dielectric layer of flexible capacitive pressure sensors employing 3D printing technology. The structure is designed with easily deformable concave and rotational structures, enabling continuous deformation under pressure. This design results in a significant expansion of the pressure response range and improvement in sensitivity. Further, the study purposively analyses crucial parameters of the devised structure that affect its compressibility and stability. These include the concave angle θ, height ratio d1/d2, rotation angle α, and width k. As a result, the ultimate pressure sensors demonstrate remarkable features such as high sensitivity (≈2.38 kPa−1 in the range of 0–10 kPa), broad detection range (734 kPa), fast response time (23 ms), and outstanding pressure resolution (0.4% at 500 kPa). This study confirms the viability of bionic structures for flexible sensors, and their potential to expand the scope of wearable electronic devices.  相似文献   

3.
The real-time, continuous monitoring of glucose/lactate, blood gases and electrolytes by implantable electrochemical sensors holds significant value for critically ill and diabetic patients. However, the wide-spread use of such devices has been seriously hampered by implant-initiated host responses (e. g., thrombus formation, inflammatory responses and bacterial infection) when sensors are implanted in blood or tissue. As a result, the accuracy and usable lifetime of in vivo sensors are often compromised. Nitric oxide (NO) is an endogenous gas molecule able to inhibit platelet adhesion/activation, inflammatory responses and bacterial growth. As such, the release of NO from the surfaces of in vivo sensors is a promising strategy for enhancement of their biocompatibility and analytical performance. In this review, the physiological functions of NO to improve the biocompatibility of implantable electrochemical sensors are introduced, followed by a brief analysis of chemical approaches to realize NO release from such devices. A detailed summary of the various types of NO releasing electrochemical sensors reported to date and their performance in benchtop and/or in vivo testing are also provided. Finally, the prospects of future developments to further advance NO releasing sensor technology for clinical use are discussed.  相似文献   

4.
Detection and the simultaneous removal of mercury ions are of vital importance. In this study, fluorescent monomers, small molecular sensors, were first synthesized using 4‐bromo‐naphthalic anhydride as precursor. These double bond bearing sensors were then grafted to polystyrene (PS) microspheres through dispersion polymerization. The sensors still retained their detecting ability when they were anchored on the surfaces of PS microspheres. Upon the addition of Hg2+ ions to the PS microspheres, both the color and the fluorescence intensity changed, which could be employed to detect Hg2+ ions. The absorption capacity of the two kinds of PS microspheres reached 0.557 mg g?1 and 0.628 mg g?1 respectively. The PS microspheres still remain their fluorescence and absorption even used for five times. These polymeric highly sensitive chemosensors may see their applications in purification of polluted environments. © 2013 Wiley Periodicals, Inc. J. Polym. Sci., Part A: Polym. Chem. 2013 , 51, 4592–4600  相似文献   

5.
A series of novel tripodal colorimetric anion sensors based on hydrazone CHN NH groups have been synthesized and their recognition behavior with anionic guests has been studied. In DMSO solutions, sensors 1 and 2 show colorimetric responses for F, H2PO4 and AcO, while in DMSO/H2O (9:1, V/V) solutions, sensor 1 shows single selectivity for AcO. 1H NMR titration confirms that the tripodal sensors could bind anions through the collaboration of three hydrazone groups and anions residing in the central cavity of the sensors.  相似文献   

6.
Herein, two electrochemical methods based on potentiometric and impedimetric transductions were presented for albumin targeting, employing screen-printed platforms (SPEs) to make easy and cost-effective sensors with good detection merits. The SPEs incorporated ion-to-electron multi-walled carbon nanotubes (MWCNTs) transducer. Sensors were constructed using either tridodecyl methyl-ammonium chloride (TDMACl) (sensor I) or aliquate 336S (sensor II) in plasticized polymeric matrices of carboxylated poly (vinyl chloride) (PVC-COOH). Analytical performances of the sensors were evaluated using the above-mentioned electrochemical techniques. For potentiometric assay, constructed sensors responded to albumin with −81.7 ± 1.7 (r2 = 0.9986) and −146.2 ± 2.3 mV/decade (r2 = 0.9991) slopes over the linearity range 1.5 μM–1.5 mM with 0.8 and 1.0 μM detection limits for respective TDMAC- and aliquate-based sensors. Interference study showed apparent selectivity for both sensors. Impedimetric assays were performed at pH = 7.5 in 10 mM PBS buffer solution with a 0.02 M [Fe(CN)6]−3/−4 redox-active electrolyte. Sensors achieved detection limits of 4.3 × 10−8 and 1.8 × 10−7 M over the linear ranges of 5.2×10−8–1.0×10−4 M and 1.4×10−6–1.4×10−3 M, with 0.09 ± 0.004 and 0.168 ± 0.009 log Ω/decade slopes for sensors based on TDMAC and aliquate, respectively. These sensors are characterized with simple construction, high sensitivity and selectivity, fast response time, single-use, and cost-effectiveness. The methods were successfully applied to albumin assessment in different biological fluids.  相似文献   

7.
《Analytical letters》2012,45(9):1755-1777
ABSTRACT

Phosphorescent oxygen sensors were evaluated for their suitability as a non-destructive method of measuring oxygen in packaged foods. Using phosphorescent phase measurements, characteristics of several types of disposable oxygen sensors were studied in order to optimize sensor chemistry, fabrication technology and performance. The optimal sensor was characterized in both the gas phase and in the liquid phase, over a temperature range of –17°C ? +30°C and oxygen concentrations between 0 and 21 kPa. Calibrations, analytical equations and temperature coefficients were obtained, which enabled accurate quantitation of oxygen and correction of optical measurements for sample temperature variations. For disposable sensor elements the resolution of the system at 22°C was about ±0.02 kPa and ±0.5 kPa at 0 and 21 kPa oxygen respectively, and in continuous monitoring mode - ±0.0054 kPa and ±0.081 kPa oxygen, respectively. Results of the use of the oxygen sensors in food packaging applications and practical recommendations are presented.  相似文献   

8.
《Analytical letters》2012,45(10):1825-1852
Abstract

A general view of the electroanalytical applications of metal‐salen complexes is discussed in this review. The family of Schiff bases derived from ethylenediamine and ortho‐phenolic aldehydes (N,N′‐ethylenebis(salicylideneiminato)—salen) and their complexes of various transition metals, such as Al, Ce, Co, Cu, Cr, Fe, Ga, Hg, Mn, Mo, Ni, and V have been used in many fields of chemical research for a wide range of applications such as catalysts for the oxygenation of organic molecules, epoxidation of alkenes, oxidation of hydrocarbons and many other catalyzed reactions; as electrocatalyst for novel sensors development; and mimicking the catalytic functions of enzymes. A brief history of the synthesis and reactivity of metal‐salen complexes will be presented. The potentialities and possibilities of metal‐Salen complexes modified electrodes in the development of electrochemical sensors as well as other types of sensors, their construction and methods of fabrication, and the potential application of these modified electrodes will be illustrated and discussed.  相似文献   

9.
A sensor array of 9 potentiometric PVC sensors has been employed for the simultaneous determination of heavy metals in soil. Sensors were firstly characterized in their response: Nernstian behavior, a concentration range from ca. 10?6 to 10?2 M and selectivity coefficients confirming that all sensors had cross‐response for the target ions. The mixed response system was modeled employing Artificial Neural Networks. The proposed tool was applied to the determination of Pb2+, Cd2+, Cu2+ and Zn2+ in soils at the mg kg?1 level with satisfactory performance. Results were compared and validated against AAS reference methodology, with correlations R2>0.948 for the four heavy metals considered.  相似文献   

10.
Motion tracking of microorganisms is useful to investigate the effects of chemical or physical stimulation on their biological functions. Herein, we describe a novel electrochemical imaging method for motion tracking of microorganisms using a large-scale integration (LSI)-based amperometric device. The device consists of 400 electrochemical sensors with a pitch of 250 μm. A convection flow caused by the motion of microorganisms supplies redox species to the sensors and increases their electrochemical responses. Thus, the flow is converted to electrochemical signals, enabling the electrochemical motion tracking of the microorganisms. As a proof of concept, capillary vibration was monitored. Finally, the method was applied to monitoring the motion of Daphnia magna. The motions of these microorganisms were clearly tracked based on the electrochemical oxidation of [Fe(CN)6]4− and reduction of O2.  相似文献   

11.
《Analytical letters》2012,45(15):3039-3063
Abstract

Progress on solution of two general problems regarding the use of in vivo planar microchemical sensors is reported. These are issues of short term and long term response stability. Reduction of preconditioning time (hydration period), i.e., the time needed by the planar microchemical sensors based on Kapton® substrate to achieve the optimal analytical performances, has been achieved. By storing the electrodes in containers with humid atmospheres (100% humidity) their short time responses, e.g. measured potential, when placed in samples to be analyzed, are practically constant after one minute of immersion. The electrode sensitivity, potential reproducibility and membrane resistance of both pH and K+ sensors were evaluated and compared before and after placing them in whole blood samples for specified periods of time. Blood serum samples were successfully assayed and the results compared with those obtained with a pH glass electrode and a blood gas analyzer, respectively. The long term stability of the membranes for in vivo use was investigated by determination of cell adhesion and membrane biostability (at 14 days of subcutaneous implantation in rats) using scanning electron microscopy.  相似文献   

12.
LaFeO3 is a p-type semiconductor catalytic material of perovskite structure (ABO3). Its magnetic and photocatalytic properties have been widely investigated, but the gas sensing properties are seldom reported, especially for toxic and noxious gases of NO2 and CO. The nanocomposites of LaFeO3 and LaFe1−x Mg x O3 (x = 0.02, 0.04, 0.06) were prepared by various methods of the wet chemical process and their exact composition, crystal structures, grain sizes, specific surfaces, morphology and the electronic interaction between components were characterized by EDX, XRD, BET, SEM and XPS analysis. The sensors based on these nanocomposites have been fabricated to examine the sensing responses to gases, and the results show that these sensors exhibited high response to both oxidizing gas (NO2) and reducing gas (CO), and the response was greatly enhanced by the surface modification of MgO. The additive method, amount of additives, and their effects on the LaFeO3 structure and gas response have been analyzed and discussed by temperature-programmed desorption (TPD) and X-ray photoelectron spectroscopic (XPS) analysis.  相似文献   

13.
Motion tracking of microorganisms is useful to investigate the effects of chemical or physical stimulation on their biological functions. Herein, we describe a novel electrochemical imaging method for motion tracking of microorganisms using a large‐scale integration (LSI)‐based amperometric device. The device consists of 400 electrochemical sensors with a pitch of 250 μm. A convection flow caused by the motion of microorganisms supplies redox species to the sensors and increases their electrochemical responses. Thus, the flow is converted to electrochemical signals, enabling the electrochemical motion tracking of the microorganisms. As a proof of concept, capillary vibration was monitored. Finally, the method was applied to monitoring the motion of Daphnia magna . The motions of these microorganisms were clearly tracked based on the electrochemical oxidation of [Fe(CN)6]4− and reduction of O2.  相似文献   

14.
《Electroanalysis》2017,29(2):616-621
Simple and fast methods for the monitoring of phenol‐like compounds are relevant in diverse fields ranging from waste management to neurosciences. Laccases are copper‐containing enzymes, which, depending on their origin, are able to oxidize different phenol compounds at different pH conditions. Through adequate laccase immobilization, disposable screen printed electrodes can be used as interphase to build amperometric phenol sensors. In this work three different laccases were studied for the determination of phenol‐like compounds, two of them are isoenzymes from Trametes trogii and the third one from Rhus vernicifera . Their immobilization on screen printed electrodes is presented for the construction of amperometric sensors. The electrode substrate is composed by graphite screen printed electrodes modified with carbon nanotubes and silica microspheres where, depending on the application, one of the three laccases is adsorbed. As each laccase shows an optimum working pH, they were conveniently selected to determine dopamine at physiological pH and catechol at acid pH. Determinations in the micromolar range were possible in both cases. Chronoamperometry shows to be an effective technique for their determinations, simpler than other electrochemical methods already presented in the literature.  相似文献   

15.
The rising amount of patients suffering for diabetes mellitus increases the requirements for effective insulin sensors. Carbon materials are a suitable choice for the development of insulin sensors due to their electrochemical characteristics. Pencil graphite electrodes (PGE) represent the trade‐off between price and excellent conductive properties. The modification of PGE by NiO and Ni nanoparticles fixed by chitosan results in surface area enlargement and improved electrocatalytic properties. This paper is focused on the comparison of different properties of Ni and NiO nanoparticles and their effect on redox reaction mechanism of insulin and detection characteristics. The electrode modified by Ni nanoparticles displays linear range of 1 μM–5 μM (R2 0.80), limit of detection (LOD) of 4.34 μM and sensitivity of 0.12 μA/μM. On the other hand, the electrode modified by NiO nanoparticles displays enhanced electrochemical characteristics such as linear range of 0.05 μM–5 μM (R2 0.99), limit of detection of 260 nM and sensitivity of 0.64 μA/μM. These properties make the NiO nanoparticles modified PGE the appropriate candidate for insulin determination.  相似文献   

16.
An application of gas sensors for rapid bioanalysis is presented. An array of temperature-modulated semiconductor sensors was used to characterize the headspace above a cell culture. Recombinant Saccharomyces cerevisiae yeast cells, able to respond to 17-estradiol by producing a reporter protein, were used as a model system. Yeast cells had the DNA sequence of the human estrogen receptor stably integrated into the genome, and contained expression plasmids carrying estrogen-responsive sequences and the reporter gene lac-Z, encoding the enzyme -galactosidase. The sensor-response profiles showed small but noticeable discrimination between cell samples induced with 17-estradiol and non-induced cell samples. The sensor array was capable of detecting changes in the volatile organic compound composition of the headspace above the cultured cells, which can be associated with metabolic changes induced by a chemical compound. This finding suggests the possibility of using cross-selective gas-sensor arrays for analysis of drugs or bioactive molecules through their interaction with cell systems, with the advantage of providing information on their bioavailability.  相似文献   

17.
《Analytical letters》2012,45(15):2414-2422
An aptamer-based magnetoelastic sensor for the determination of Staphylococcus aureus is reported. Aptamers specific to S. aureus were used to ensure specific and selective binding of bacteria on the sensor surface. The sensors were exposed to S. aureus concentrations of 1 × 101–1 × 1011 colony forming units per milliliter, and the changes in resonance frequency were monitored. The sensitivity was higher for sensors with smaller physical dimensions. The biosensor with dimensions of 2 × 5 × 0.028 millimeters provided a linear dynamic range of 101–1011 colony forming units per milliliter and a detection limit of 5 colony forming units per milliliter. The results also demonstrated that the magnetoelastic sensors determined the targeted pathogenic species with good selectivity. The method was employed to determine S. aureus in water, and the results were comparable to those obtained by plate-counting methods. The high sensitivity, selectivity, and stability of the aptamer provide a promising approach for the determination of pathogenic bacteria.  相似文献   

18.
Amr L. Saber 《Electroanalysis》2010,22(24):2997-3002
Simple, selective and accurate sensors were developed for the determination of melatonin and oxomemazine in biological samples (urine) and in pharmaceutical preparations. Potentiometric measurements were based on bismus tetraiodate‐drug ion‐pair as novel electroactive materials incorporating a plasticized PVC membrane with o‐nitrophenyl octyl ether or dioctyl phthalate. Each sensor was conditioned for at least two days in 0.1 M drug solution before use. It exhibited fast and stable Nernstian response for melatonin and oxomemazine over the concentration range of 1.0×10?6–1.0×10?2 M and 1.0×10?5–1.0×10?2 M, pH range of 3.0–6.5 and 3.5–6.0 for melatonin and oxomemazine sensors, respectively. Results with an average recovery not more than 101 % and a mean standard deviation less than 1.0 % of the nominal were obtained for the four sensors. The sensors showed reasonable selectivity towards investigated drugs in presence of many cations.  相似文献   

19.
Headspace analysis by means of sensor arrays has been successfully applied to a wide range of qualitative applications. In this study, a six element array of coated Quartz Crystal Microbalance (QCM) sensors was used for the headspace analysis of milk volatiles. The sensors were exposed to uncontaminated samples of milk and samples contaminated with Pseudomonas fragi (Ps. fragi) or Escherichia coli (E. coli). Principal component analysis (PCA) was used to analyse the sensor array responses. No discrimination between uncontaminated milk samples and those contaminated with Ps. fragi was observed. This can be explained by Ps. fragi being a poor fermenter of milk. However, encouraging results were found for the discrimination between the milk samples and those contaminated with E. coli.This revised version was published online in November 2005 with corrections to the Cover Date.  相似文献   

20.
DNA-based probes have gained significant attention as versatile tools for biochemical analysis, benefiting from their programmability and biocompatibility. However, most existing DNA-based probes rely on fluorescence as the signal output, which can be problematic due to issues like autofluorescence and scattering when applied in complex biological materials such as living cells or tissues. Herein, we report the development of bioluminescent nucleic acid (bioLUNA) sensors that offer laser excitation-independent and ratiometric imaging of the target in vivo. The system is based on computational modelling and mutagenesis investigations of a genetic fusion between circular permutated Nano-luciferase (NLuc) and HaloTag, enabling the conjugation of the protein with a DNAzyme. In the presence of Zn2+, the DNAzyme sensor releases the fluorophore-labelled strand, leading to a reduction in bioluminescent resonance energy transfer (BRET) between the luciferase and fluorophore. Consequently, this process induces ratiometric changes in the bioluminescent signal. We demonstrated that this bioLUNA sensor enabled imaging of both exogenous Zn2+ in vivo and endogenous Zn2+ efflux in normal epithelial prostate and prostate tumors. This work expands the DNAzyme sensors to using bioluminescence and thus has enriched the toolbox of nucleic acid sensors for a broad range of biomedical applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号