首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 689 毫秒
1.
Bandekar SV  Dhadke PM 《Talanta》1998,46(5):1181-1186
Solvent extraction of tin(IV) from hydrochloric acid media was carried out with 2-ethylhexyl phosphonic acid mono-2-ethylhexyl ester (PC-88A) in toluene. Tin(IV) was quantitatively extracted with 2.5x10(-2) M PC-88A in toluene from 0.1-0.3 M HCl when equilibrated for 5 min. Tin(IV) from the organic phase was stripped with 4 M HCl and determined spectrophotometrically by both the morin and pyrocatechol violet method. The nature of the extracted species was determined from the log-log plots. Various other diluents such as xylene, hexane and cyclohexane also gave quantitative extraction of tin. The metal loading capacity of the reagent was found to be 0-15 ppm of tin(IV). The extraction of tin(IV) was carried out in the presence of various ions to ascertain the tolerance limit of individual ions. Tin(IV) was successfully separated from commonly associated metal ions such as antimony(III), bismuth(III), lead(II), thallium(I), copper(II), nickel(II), etc. The method was extended for determination of tin in real samples.  相似文献   

2.
Tin octoate is used as a catalyst in the synthesis of polydimethylsiloxane (PDMS), a room temperature vulcanizing (RTV) silicone rubber. This rubber is largely used in the medical field due to its great biocompatibility. In this framework, a high-speed and costless analytical method for the determination of stannic ions, Sn(IV), in the presence of stannous ions, Sn(II), has been developed.The separation of these two ions was carried out using differential pulse polarography (DPP). For this purpose, the tin species contents in the catalyst is quantitatively extracted under inert condition to avoid any changes in the ratio Sn(IV)/Sn(II). Polarography showed well-shaped oxidation and reduction peaks respectively at −650 and −860 mV for stannous ions. The peak of the stannic ion was well separated and appeared at −1210 mV. Many parameters such as extraction process, extraction time, pH, chelating agents and polarographic conditions were optimized. We have also demonstrated that no oxidation of the stannous ions occurred during the sample preparation.The dosing range considered in this study extends between 10 and 40 μg/mL, corresponding to 6.8% and 27.2% of the degradation product (Sn(IV)) in the catalyst, regarding to the sampling. Finally this method was successfully validated using the total error concept.  相似文献   

3.
Hulanicki A  Jedral W 《Talanta》1976,23(3):259-261
The current efficiency of tin(II) generation has been measured for various electrolytes and electrodes. The best results (>99.9%) were obtained with the paraffin-impregnated graphite electrode in 2M CaCl(2) + 0.2M HCl + 0.2M SnCl(4). In titrations of platinum(IV) with electrogenerated tin(II) in an electrolyte containing chloride or bromide it was found that the presence of platinum(II) or (IV) interferes in the cathodic generation of tin(II). The platinum is reduced to the elemental state at the electrode and causes simultaneous generation of hydrogen which decreases the current efficiency. This effect is more pronounced in chloride media.  相似文献   

4.
This work describes a study of the underpotential deposition (UPD) of Sn2+ on a polycrystalline gold disc electrode using cyclic voltammetry (CV) and chronocoulometry (CC). Sn2+ ions showed well-defined peaks from UPD and UPD stripping (UPD-S) in 1 mol/L HCl solutions, while bulk deposition (BD) and BD stripping (BD-S) of the ions were also observed. The measured UPD shifts, EUPD, between the UPD-S and the BD-S peaks were more than 200 mV. The UPD charge and the surface coverage of tin were measured by CC. A new method for determining Sn2+ was therefore developed, based on the excellent electrochemical properties of the Au/Sn UPD system. A plot of the UPD-DPASV (differential pulse anodic stripping voltammetry) signal versus the Sn(II) concentration was obtained for [Sn(II)] of 1.98×10–7 to 3.64×10–5 M. The method developed here has been applied to determine the tin in a tin plate sample.  相似文献   

5.
《Analytical letters》2012,45(10):909-922
Abstract

Cyclic voltammaetry of mixed tin(II)/tin(IV) solutions was investigated in 6M HCl on gold and mercury electrodes. It was found that the reduction of tin(II) to tin(iv) proceeded irreversibly while tin(II) to tin(IV) was reversible. Two forms of tin(IV) are postulated. The peak potential for the reduction of tin(IV) was a function of both tin(II) and tin(IV) while that for the oxidation of tin(II) was a function only of tin(II) concentration Potentials for all oxidations and reductions were a function of potential scan rate.  相似文献   

6.
Isotope dilution-thermal ionisation mass spectrometry (ID-TIMS) analysis has been applied to the determination of tin in a fly ash sample supplied by the EC Joint Research Centre (Ispra, Italy). The proposed procedure includes the silica gel/phosphoric acid technique for tin thermal ionisation activation and a strict heating protocol for isotope ratio measurements. Instrumental mass discrimination factor has been previously determined measuring a natural tin standard solution. Spike solution has been prepared from 112Sn-enriched metal and quantified by reverse isotope dilution analysis. Two sample aliquots were spiked and tin was extracted with 4.5 M HCl during 25 min ultrasound exposure time. Due to the complex matrix of this fly ash material, a two-step purification stage using ion-exchange chromatography was required prior TIMS analysis. Obtained results for the two sample-spike blends (10.11 ± 0.55 and 10.50 ± 0.64 μmol g−1) are comparable, both value and uncertainty. Also a good reproducibility is observed between measurements. The proposed ID-TIMS procedure, as a primary method and due to the lack of fly ash reference materials certified for tin content, can be used to validate more routine methodologies applied to tin determination in this kind of samples.  相似文献   

7.
This paper is concerned with the study of isotope exchange reaction between Sn(II) and Sn(IV) in hydrochloric acid solutions. The kinetics of the exchange reaction of tin in these solutions were studied by extraction of Sn(IV)-hydroxyquinolate into chloroform.113Sn tracer, initially in the Sn(IV) state, was used. The rate of exchange reaction was determined at 22°C in a wide range of hydrochloric acid concentrations (2.8–12M). The dependence of the exchange rate on the concentration of chloride and hydrogen ions in these solutions (ionic strength: I∼8 and I∼12) are given. The activation energy dependence on chloride ion concentration at I∼12 was determined. The possible mechanism of the exchange reaction between tin(II) and tin(IV) is discussed on the basis of these data.  相似文献   

8.
A novel method has been developed for the solvent extraction of tin(IV) from 8 M hydrochloric acid with 4% N‐n‐octylaniline. Tin(IV) from the organic phase was determined spectrophotometrically with pyrocatechol violet at 550 nm. Extraction was found to be quantitative in the range of 7–10 M hydrochloric acid. When the concentration of N‐n‐octylaniline was varied from 0.05–20% in xylene, it showed that optimum concentration was > 3%. Amongst diluents like benzene and xylene, toluene was found to be an effective diluent. Effect of shaking time, concentration of metal ion, and salting out agents was studied. Tolerance limits of various diverse ions were determined by masking interfering cations. Tin(IV) was separated from associated elements in its binary mixture with Se(IV), Sb(III), Bi(III), Pb(II), Au(III), Cu(II) and Zn(II) and from its ternary mixtures with Sb(III), Bi(III) and Cu(II), Au(III). The proposed method was applied for separation and determination of tin(IV) in tin bearing alloys and foodstuffs.  相似文献   

9.
Costa AC  Teixeira LS  Ferreira SL 《Talanta》1995,42(12):1973-1978
In the present paper, a new procedure using Pyrocatechol Violet (PCV) for the determination of tin in copper-based alloys is proposed. The use of HEDTA as masking agent allowed tin to be determined in the presence of large amounts of copper, without any separation procedure. The method is more selective than previous methods. Cetyltrimethylammonium bromide (CTAB) and Tween-20 are used to increase the stability of the system.

The method can be applied directly to an acidic solution of Sn(IV) in the range 2.0–60.0 μg with a final volume of 50 ml. The pH is adjusted to 2.0 ± 0.2 with glycine buffer and, after 30 min, the absorbance is measured at 660 nm. Al(III), Cd(II), Co(II), Mg(II), Ca(II), Mn(II), Ni(II) and Pb(II) do not interfere at the 500 mg level; 20 000 μg of Cu(II) and 400 μg of NaCl can be present. The interference at 100 μg of Fe(III) can be masked with ascorbic acid. Bi(III), Sb(V), Ti(IV), Mo(VI), EDTA, tartrate, citrate and iodide interfere. The proposed method was used for tin determination in several copper-based alloys and a comparison of the analytical results with certified values indicates that the procedure provides accurate and precise results.  相似文献   


10.
A polarographic method is described for determining down to 0.01% lead and tin in iron and steel, using citric acid as supporting electrolyte. The sample is dissolved under purified nitrogen. Two curves are recorded for each sample solution: the first shows the sum of lead(II) and tin(II), and the second, after oxidation of tin(II) with a solution of iodine, gives a wave for lead only.  相似文献   

11.
DFT methods have been applied for the calculation of several ground-state properties of neutral and charged ruthenium(II) and osmium(II) tin trihydride complexes bearing N-donor, P-donor and C-donor ancillary ligands in their coordination sphere. Complexes of the type M(SnH3)(Tp)(PPh3)P(OMe)3, M(SnH3)(Cp)(PPh3)P(OMe)3 and [M(SnH3)(Bpy)2P(OMe)3]+ (M = Ru, Os; Tp = tris(pyrazol-1-yl)borate; Cp = cyclopentadienyl ion; Bpy = 2,2′-bipyridine) have been studied using the EDF2 and B3PW91 functionals. The same calculations have been carried out also on the corresponding [M]-CH3 and [M]-H compounds, to compare the electronic features of the different reactive ligands coordinated to the same metal fragments. Charge distribution analyses were used to give insight into the roles of the transition metal centres and the ancillary ligands on the properties of the coordinated SnH3 group. The molecular orbitals of the methyl- and trihydrostannyl-complexes were compared to understand the nature of the [M]-SnH3 bond and the electronic transitions of these species.  相似文献   

12.
The reaction of β-diketiminate substituted germanium(II) and tin(II) fluorides (LGeF (1) and LSnF (2)) (L = CH{(CMe)2(2,6-iPr2C6H3N)2}) with diiron nonacarbonyl, Fe2(CO)9 at room temperature, leads to the iron carbonyl complexes of germanium(II) LGeFFe(CO)4 (3) and tin(II) LSnFFe(CO)4 (4), respectively. Compounds 3 and 4 were characterized by elemental analysis, NMR spectroscopy, and mass spectrometry. Furthermore, both complexes (3 and 4) were investigated by X-ray structural analysis which shows that both compounds are monomeric in the solid state containing terminal fluorine atoms.  相似文献   

13.
Small amounts (0.1–0.2 mg) of tin were determined quantitatively in the presence of 1000 times the amount of antimony. The method is based on the measurement of the turbidity caused by tin(IV) with 3-nitro-4-hydroxy-bcnzene-arsonic ; it has great specificity.  相似文献   

14.
The design, construction and optimization studies of a continuous flow hydride generation laser-induced breakdown spectroscopic system, HG-LIBS, for the determination of tin in aqueous environments is presented. Optimization of the Laser Induced Breakdown Spectroscopy (LIBS) signal with respect to carrier gas flow rate, analyte, acid (HCl) and reductant (NaBH4) concentrations and flow rates was performed by using spectral emission intensity from the neutral Sn(I) line at 284.0 nm under atmospheric pressures. With flow rates of 5.0 mL/min for NaBH4 and 2.5 mL/min for HCl, optimum NaBH4 and HCl concentrations were determined as 2.0% (w/v) and 1.0% (v/v), respectively. The hydride generation efficiency of the system was tested for tin hydride, stannane (SnH4), by inductively coupled plasma mass spectrometer (ICP-MS). It was found that higher than 99% of the analyte was released into the gaseous phase. Upon optimization, the minimum detectable Sn concentration was found as 0.3 mg/L in water samples. That corresponds to more than two orders of increase in sensitivity compared to methods that employ common sample introduction techniques in liquids analysis by LIBS. Over 90% recoveries were obtained from spiking experiments with river, tap and drinking water samples. Results illustrate potential use of the continuous flow HG-LIBS system for monitoring of Sn concentrations in aqueous environments.  相似文献   

15.
trans-Bis(ferrocenecarboxylato)(5,10,15,20-tetraphenylporphyrinato)tin(IV) complex Sn(TPP)(FcCOO)2 has been synthesized and fully characterized. The X-ray structural analysis of Sn(TPP)(FcCOO)2 reveals that the tin(IV) center is octahedrally coordinated by the porphyrin occupying the square base and axial coordination of two ferrocenecarboxylato ligands in an anti orientation with respect to each other. The Fe(II) center of the ferrocenecarboxylato ligand lies 5.7 Å from the tin(IV) center of the porphyrin ring. The cyclic voltammogram of Sn(TPP)(FcCOO)2 exhibits three distinctive redox couples consisting of one oxidative wave and two reductive waves due to the ferrocenecarboxylato ligands and the porphyrin ring, respectively.  相似文献   

16.
Rhodium complexes such as [RhCl(cod)]2, [Rh(cod)2]BF4, and [Rh(cod)(CH3CN)2]BF4 function as catalysts for carbonyl allylations by allylic alcohols with 1 equimolar amount of tin(II) chloride to each allylic alcohol and aldehyde in THF at 50 °C to produce the corresponding homoallylic alcohols.  相似文献   

17.
A new tin(IV) complex, (C13H10NO)[SnCl4(C9H6NO)]·2CH3OH, was prepared in a facile process and characterized by 1H, 13C, and 119Sn NMR, IR, and UV spectroscopy in addition to single-crystal X-ray diffraction analysis. Current–voltage (I–V) characteristics, photoluminescence (PL), and electroluminescence (EL) properties of the complex have been investigated and an application of the prepared complex in fabrication of an organic light-emitting diode has been demonstrated. The EL of the compound exhibits blue–green emission at 494?nm. Tin(IV) oxide core that resulted from direct thermal decomposition of the complex at 450?°C in air was characterized by X-ray powder diffraction and scanning electron microscopy; then, the PL property was investigated and compared with the PL of the complex. The tin(IV) oxide core showed a band gap of ~3.81?eV determined from the UV/visible absorption spectrum. The tin oxide core showed stable PL with one emission peak centered at 581?nm.  相似文献   

18.
A disposable paper-based sensor (PBS) is described for the determination of Cu(II) in natural and waste waters at approximately 2 cents per measurement. The device makes use of a polymer inclusion membrane (PIM) to provide the selectivity for Cu(II). The PIM consists of 40 wt% di(2-ethlyhexyl) phosphoric acid (D2EHPA) as the carrier, 10 wt% dioctyl phthalate (DOP) as a plasticizer, 49.5 wt% poly(vinyl chloride) (PVC) as the base polymer and 0.5 wt% (m m−1) 1-(2′-pyridylazo)-2-naphthol (PAN) as the colourimetric reagent. High selectivity under mildly acidic conditions (HCl, pH 2.0) is achieved for Cu(II) in the presence of frequently encountered metal ions in natural and waste waters such as Fe(III), Al(III), Zn(II), Cd(II), Pb(II), Ca(II), Mg(II), and Ni(II).  相似文献   

19.
Agrawal YK  Sharma KR 《Talanta》2005,67(1):112-120
A new functionalized calix[6]crown hydroxamic acid is reported for the speciation, liquid-liquid extraction, sequential separation and trace determination of Cr(III), Mo(VI) and W(VI). Chromium(III), molybdenum(VI) and tungsten(VI) are extracted at pH 4.5, 1.5 M HCl and 6.0 M HCl, respectively with calixcrown hydroxamic acid (37,38,39,40,41,42-hexahydroxy7,25,31-calix[6]crown hydroxamic acid) in chloroform in presence of large number of cations and anions. The extraction mechanism is investigated. The various extraction parameters, appropriate pH/M HCl, choice of solvent, effect of the reagent concentration, temperature and distribution constant have been studied. The speciation, preconcentration and kinetic of transport has been investigated. The maximum transport is observed 35, 45 and 30 min for chromium(III), molybdenum(VI) and tungsten(IV), respectively. For trace determination the extracts were directly inserted into the plasma for inductively coupled plasma atomic emission spectrometry, ICP-AES, measurements of chromium, molybdenum and tungsten which increase the sensitivity by 30-fold, with detection limits of 3 ng ml−1. The method is applied for the determination of chromium, molybdenum and tungsten in high purity grade ores, biological and environmental samples. The chromium was recovered from the effluent of electroplating industries.  相似文献   

20.
Carbonyl allylations by allylic chlorides either with tin(IV) iodide and tetrabutylammonium iodide (TBAI) in dichloromethane or with tin(IV) iodide and sodium iodide in 1,3-dimethylimidazolidin-2-one at room temperature produced the corresponding homoallylic alcohols. The carbonyl allylations probably proceeded via the reduction of tin(IV) iodide to triiodostannate(II) species with iodide sources such as TBAI and NaI, which led to the construction of a tin(IV)-catalytic cycle based on regeneration of tin(IV) iodide via the transmetalation of homoallyloxytriiodotin to homoallyloxytrimethylsilane with iodotrimethylsilane.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号