首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
Gotardo MA  Gigante AC  Pezza L  Pezza HR 《Talanta》2004,64(2):361-365
In this report an analytical method to determine furosemide by using diffuse reflectance spectroscopy is presented. This study shows that this technique can give quantitative results using spot test analysis, particularly in the case of pharmaceuticals containing furosemide. The color spot test could be obtained by reaction between furosemide with p-dimethylaminocinnamaldehyde, in acid medium. This reaction produced a stable complex on filter paper after heating to 80 °C for 5 min. All reflectance measurements were carried out at 585 nm and the linear range was from 7.56×10−3 to 6.05×10−2 mol l−1, with a correlation coefficient of 0.999. The limit of detection was estimated to be 2.49×10−3 mol l−1 (R.S.D.=1.7%) and the effect of common excipients on the reflectance measurements was evaluated. The method was applied to determine furosemide in commercial brands of pharmaceuticals. The results obtained by the proposed method were favorably compared with those of the official method, showing for the first time ever that quantitative spot test analysis by diffuse reflectance could be successfully used to determine furosemide in tablets.  相似文献   

2.
A new enantioselective potentiometric sensor containing chiral salen Mn(III) as the chiral selector was designed for the assay of l-mandelic acid (l-MA). Optimized membrane electrodes displayed linear dynamic range from 1 × 10−5 to 1 × 10−1 mol L−1 with a detection limit of 7.2 × 10−6 mol L−1 and a Nernstian response of −58.1 ± 0.5 mV decade−1 towards l-MA within pH range 7.0-10.2. The potentiometric enantioselectivity coefficient () of this sensor was −4.0, indicating that the chiral salen Mn(III) complex-based electrode exhibited fairly good discrimination toward l-MA over counter isomer d-MA. The mechanism of chiral recognition for l-MA is discussed by using HF/STO-3G calculation method simulation.  相似文献   

3.
BiFeO3 magnetic nanoparticles (BFO MNPs) are used as a catalyst to develop an ultrasensitive method for the determination of H2O2. It is found that BFO MNPs can catalyze the decomposition of H2O2 to produce OH radicals, which in turn oxidize the weakly fluorescent benzoic acid to a strongly fluorescent hydroxylated product with a maximum emission at 405 nm. This makes it possible to sensitively quantify traces of H2O2. Under optimized conditions, the fluorescence intensity is observed to be well linearly correlated with H2O2 concentration from 2.0 × 10−8 to 2.0 × 10−5 mol L−1 with a detection limit of 4.5 × 10−9 mol L−1 (S/N = 3). In addition, a selective method for glucose determination is developed by using both glucose oxidase and BFO MNPs, which has a linear range for glucose concentration from 1.0 × 10−6 to 1.0 × 10−4 mol L−1 with a detection limit of 5.0 × 10−7 mol L−1. These new methods have been successfully applied for the determination of H2O2 in rainwater and glucose in human serum samples.  相似文献   

4.
Terbium sensitized fluorescence was used as a post-column detection system to develop a simple, sensitive and rapid high-performance liquid chromatographic method for the simultaneous determination of catecholamines norepinephrine (NE), epinephrine (E) and dopamine (DA).Catecholamines were separated by an ion-pair reversed-phase chromatography on a BDS-Hypersil analytical column with a mobile phase of methanol and 50 mmol l−1 acetate buffer (pH 4.7) containing 1.1 mmol l−1 SOS and 0.11 mmol l−1 EDTA (15+85 v/v).Catecholamines and the internal standard (3,4-dihydroxybenzylamine, DHBA) were post-column derivatized by the addition to the eluent of an alkaline solution containing a stoichiometric mixture of terbium(III) chloride and EDTA. Fluorescence detection (λex=300 nm, λem=545 nm) is based on the sensitization of terbium ion fluorescence after complexation with catecholamines.The chemical compatibility between the eluent and the post-column reagent was studied and the analytical characteristics of the method were established. Detection limits found were 1.0×10−8, 4.0×10−8 and 7.0×10−8 mol l−1 for NE, E and DA, respectively. The method has been successfully applied to the determination of catecholamines in urine samples after solid-phase extraction (SPE) pre-treatment. Recoveries from urine spiked with NE (4.0×10−7, 2.0×10−6 and 4.0×10−6 mol l−1), E (8.2×10−8, 4.1×10−7 and 8.2×10−7 mol l−1) and DA (1.0×10−6, 5.0×10−6 and 1.0×10−5 mol l−1) varied from 98 to 100% (mean=99.3%), from 106 to 107% (mean=106.3%) and from 98 to 101% (mean=99.3%), respectively. The between-run precision (relative standard deviation, R.S.D.) for the method for three urine samples at different concentration levels of each catecholamine varied from 3.6 to 7.0%.  相似文献   

5.
A flow-injection chemiluminescence (CL) method is described for the determination of fluoroquinolones including ciprofloxacin, norfloxacin and ofloxacin. The method is based on the enhancement by these compounds of the weak CL from peroxynitrous acid. The linear ranges are 1.0×10−7 to 1.0×10−5 mol l−1 for ciprofloxacin and norfloxacin, and 3.0×10−7 to 3.0×10−5 mol l−1 for ofloxacin, respectively. The detection limits (S/N=3) are 4.5×10−8 mol l−1 ciprofloxacin, 5.9×10−8 mol l−1 norfloxacin and 1.1×10−7 mol l−1 ofloxacin, respectively. The proposed method was applied to the determination of fluoroquinolones in pharmaceutical preparations.  相似文献   

6.
A highly sensitive flow-injection (FI) method with chemiluminescence (CL) detection is used for the determination of l-ascorbic acid. The method is based on the CL reaction of Rhodamine B with cerium(IV) in sulfuric acid media. l-Ascorbic acid is suggested to be a catalyst utilized in the energy-transferred excitation process. The proposed procedure allows quantitation of l-ascorbic acid in the range 3.8×10−13 to 1.0×10−10 mol l−1 with a correlation coefficient of 0.9998 (n=5) and relative standard deviation (R.S.D.) of 0.92% (n=11) at 1.0×10−11 mol l−1. The detection limit (3×blank) was 1.0×10−13 mol l−1. The method is successfully used to determine l-ascorbic acid in fresh vegetables. The possible mechanism of the chemiluminescence in the system is discussed.  相似文献   

7.
A method for determination of nine brominated phenols as environmental risk compounds was developed by on-line coupled capillary isotachophoresis and capillary zone electrophoresis (ITP–CZE). For ITP step, 1 × 10−2 mol L−1 hydrochloric acid with 3 × 10−2 mol L−1 ammediol pH 9.1 was used as the leading electrolyte, and 3 × 10−2 mol L−1 β-alanine with 2 × 10−2 mol L−1 sodium hydroxide pH 10.05 was used as the terminating electrolyte. As the background electrolyte for CZE separation, 2.5 × 10−2 mol L−1 β-alanine with 2.5 × 10−2 mol L−1 lysine pH 9.6 was used. All electrolytes contained 0.05% or 0.1% (m/v) hydroxyethylcellulose to suppress the electroosmotic flow. UV detection at wavelength 220 nm was used. Detection limits in order of tens of nmol L−1 were achieved. Good repeatability of migration times (less than 0.33% RSD) and good repeatability of peak areas (less than 7.19% RSD) at concentration level 5 × 10−8 mol L−1 were observed. Developed ITP–CZE method was applied to determination of brominated phenols in spiked tap and river water samples.  相似文献   

8.
Liu T  Li M  Li Q 《Talanta》2004,63(4):1053-1059
Voltammetric behavior of dopamine (DA) on a gold electrode modified with the self-assembled monolayer (SAM) of N-acetylcysteine has been investigated, and one pair of well-defined redox peaks of dopamine is obtained at the SAM modified gold electrode. The oxidation peak current increases linearly with the concentration of dopamine in the range of  mol l−1. The detection limit is 8.0×10−7 mol l−1. This method will be applicable to the determination of dopamine in injection of dopamine hydrochloride, and the good recovery of dopamine is obtained. Furthermore, The SAM modified gold electrode can resolve well the voltammetric responses of dopamine and ascorbic acid (AA), so it can also be applied to the determination of dopamine in the presence of ascorbic acid.  相似文献   

9.
A novel method of first derivative synchronous fluorescence was developed for the rapid simultaneous analysis of trace 1-hydroxypyrene (1-OHP), 1-naphthol (1-NAP), 2-naphthol (2-NAP), 9-hydroxyphenanthrene (9-OHPe) and 2-hydroxyfluorene (2-OHFlu) in human urine. Only one single scan was needed for quantitative determination of five compounds simultaneously when Δλ = 10 nm was chosen. In the optimal experimental conditions, there was a linear relationship between the fluorescence intensity and the concentration of 1-OHP, 1-NAP, 2-NAP, 9-OHPe and 2-OHFlu in the range of 1.75 × 10−9 to 4.50 × 10−6 mol L−1, 3.64 × 10−8 to 2.20 × 10−4 mol L−1, 8.18 × 10−9 to 1.20 × 10−4 mol L−1, 3.26 × 10−9 to 8.50 × 10−5 mol L−1 and 4.88 × 10−9 to 5.50 × 10−6 mol L−1, respectively. The limits of detection (LOD) were found to be 5.25 × 10−10 mol L−1 for 1-OHP, 1.10 × 10−8 mol L−1 for 1-NAP, 2.46 × 10−9 mol L−1 for 2-NAP, 9.77 × 10−10 mol L−1 for 9-OHPe and 1.46 × 10−9 mol L−1 for 2-OHFlu. The proposed method is reliable, selective and sensitive, and has been used successfully in the determination of traces of 1-OHP, 1-NAP, 2-NAP, 9-OHPe and 2-OHFlu in human urine samples, whose results were in good agreement with those gained by the HPLC method.  相似文献   

10.
The reactions of OH, H and eaq with 2,4,5-trichlorophenoxyacetic acid (2,4,5-T) and 4-chloro-2-methylphenoxyacetic acid (MCPA) were studied by pulse radiolysis. The site of OH-radicals addition to the aromatic ring of 2,4,5-T was found to be—C1: ∼18%, C2/C4/C5: total ∼28% and C3/C6: total ∼41%. The overall rate constants with OH-radicals were k(OH+2,4,5-T)=6.4 (±0.5)×109 mol dm−3 s−1 and k(OH+MCPA)=8.5 (±0.8)×109 mol dm−3 s−1. The radiation induced decomposition of the pesticides, chloride- and product formation (phenolic compounds, aliphatic acids) was studied by gamma radiolysis as a function of dose. A mechanism for acetate formation is discussed. The presence of oxygen during irradiation affected the decomposition rate only indiscernibly, however, chloride elimination, ring fragmentation (formation of aliphatic acids), TOC- and toxicity reduction were strongly enhanced. For complete removal of 500 μmol dm−3 herbicides a dose of ∼4 kGy was required. Using air saturation during irradiation a reduction of 37-40% of the TOC was observable at 5 kGy, detoxification (luminescence inhibition <20%) was achieved with 10 kGy.  相似文献   

11.
Liang YD  Song JF  Yang XF  Guo W 《Talanta》2004,62(4):757-763
A new flow-injection chemiluminescence (CL) method for determination of chloroquine is proposed based on a stronger chemiluminescence of chloroquine in hydrogen peroxide-nitrite-sulfuric acid medium. The proposed method allows the measurement of chloroquine over the range of 3.0×10−7 to 1.0×10−5 mol l−1. The detection limit is 8.6×10−8 mol l−1, and the relative standard deviation for 1.0×10−6 mol l−1 chloroquine (n=11) is 1.6%. The CL mechanism is also discussed.  相似文献   

12.
A silver hexacyanoferrate nanoparticles/carbon nanotubes modified glassy carbon electrode was fabricated and then successfully used for the simultaneous determination of ascorbic acid, dopamine and uric acid by cyclic voltammetry. A detailed investigation by transmission electron microscopy (TEM) and electrochemistry was performed in order to elucidate the preparation process and properties of the nanocomposites. The size of silver hexacyanoferrate nanoparticles was examined by TEM around 27 nm. Linear calibration plots were obtained over the range of 4.0 × 10−6-7.8 × 10−5, 2.4 × 10−6-1.3 × 10−4 and 2.0 × 10−6-1.5 × 10−4 mol L−1 with detection limits of 4.2 × 10−7,1.4 × 10−7 and 6.0 × 10−8 mol L−1 for ascorbic acid, dopamine and uric acid, respectively. The practical analytical utilities of the modified electrode were demonstrated by the determination of ascorbic acid, dopamine and uric acid in urine and human blood serum samples.  相似文献   

13.
Terbium sensitized fluorescence was used to develop a sensitive and simple spectrofluorimetric method for the determination of the anthranilic acid derivatives furosemide and mefenamic and tolfenamic acids. The method makes use of radiative energy transfer from anthranilates to terbium ions in alkaline methanolic solutions. Optimum conditions for the formation of the anthranilate-Tb3+ complexes were investigated. Under optimized conditions, the detection limits are 6 x 10(-9), 1.4 x 10(-8) and 9.0 x 10(-9) mol l-1 for furosemide, mefenamic acids and tolfenamic acid, respectively. The range of application is 2.5 x 10(-8)-5.0 x 10(-5) mol l-1 for all three drugs. The method was successfully applied to the determination of furosemide and mefenamic and tolfenamic acids in serum after extraction of the samples with ethyl acetate, evaporation of the organic layer under a stream of nitrogen at 40 degrees C and reconstitution of the residue with alkaline methanolic terbium solution prior to instrumental measurement. The mean recoveries from serum samples spiked with furosemide (5.0 x 10(-7), 2.0 x 10(-6) and 8.0 x 10(-6) mol l-1), mefenamic acid (3.0 x 10(-6), 9.0 x 10(-6) and 3.0 x 10(-5) mol l-1) and tolfenamic acid (3.1 x 10(-6), 12.5 x 10(-6) and 2.5 x 10(-5) mol l-1) were 96 +/- 8, 101 +/- 5 and 98 +/- 7%, respectively. The within-run precision (RSD) for the method for two serum samples of each drug varied from 2 to 8% and the day-to-day precision for two concentration levels varied from 2 to 13%.  相似文献   

14.
Vinod K. Gupta  Manoj K. Pal 《Talanta》2010,82(4):1136-1142
A new terbium selective sensor based on N-(2-hydroxyphenyl)-3-(2-hydroxyphenylhydroxyphenylimino)-N-phenylbutanamidine (L1) and N,N′-bis((1H-indole-3-yl)methylene)butane-1,4 diamine (L2) as a ionophore is reported. Effect of various plasticizers; 2-nitrophenyloctylether (o-NPOE), dibutyl butylphosphonate (DBBP), chloronaphthelene (CN), dioctylphthalate (DOP) and tri-(2-ethylhexyl)phosphate (TEHP) with anion excluder, potassium tetrakis (p-chloropheny1)borate (KTpClPB) have been studied. The membrane with a composition of ionophore (L1):KTpClPB:PVC:o-NPOE (w/w, %) in ratio of 3.0:5.0:30.0:62.0 exhibited enhanced selectivity towards terbium ions (III) in the concentration range of 3.5 × 10−7 to 1.0 × 10−2 M with a detection limit of 1.2 × 10−7 M and a Nernstian slope (20.0 ± 0.5 mV dec−1 activity). The sensors showed the working pH range to be 3.5-7.5 with response time of 11 s. The sensor has been found to work satisfactorily in partially non-aqueous media up to 15% (v/v) content of methanol, ethanol or acetonitrile and could be used for a period of 3 months. The selectivity coefficients indicated high selectivity for terbium (III). The fast and stable response, good reproducibility and long-term stability of the sensors were observed. The application of the sensor has been demonstrated in determination of terbium (III) ions in spiked water samples.  相似文献   

15.
The polyamines, octyl-[2-(2-octylamino-ethylamino)-ethyl]-amine (L1) and octyl-{2-[2-(2-octylamino-ethylamino)-ethylamino]-ethyl}-amine (L2), have been used as anion ionophores in PVC-based membrane ion-selective electrodes. Different electrodes were prepared containing L1, or L2, and o-nitrophenyl octyl ether (NPOE) or bis(2-ethylhexyl)sebacate (DOS) as plasticizers. The response of the electrodes was tested in two different buffers, HEPES-KOH (pH 7) and MES-KOH (pH 5.6). Electrodes containing L1 and L2 with NPOE (E1 and E2, respectively) showed a Nernstian response for thiocyanate with a good response time. The detection limit, linear range and slope for electrode E1 were 3.8 × 10−6 mol dm−3, 1 × 10−5 to 1 × 10−1 mol dm−3 and −57.2 mV decade−1 at pH 5.6 and 4.47 × 10−6 mol dm−3, 1.95 × 10−5 to 1 × 10−1 mol dm−3 and −58.1 mV decade−1 at pH 7.0. For electrode E2 the detection limit, linear range and slope found were 2.63 × 10−6 mol dm−3, 7.94 × 10−6 to 1 × 10−1 mol dm−3 and −58.5 mV decade−1 at pH 5.6 and 1.23 × 10−5 mol dm−3, 7.95 × 10−5 to 1 × 10−1 mol dm−3 and −46.0 mV decade−1 at pH 7. In contrast, electrodes containing DOS as plasticizers gave only response at pH 5.6 (detection limit, linear range and slope at pH 5.6 were 3.16 × 10−5 mol dm−3, 1 × 10−4 to 1 × 10−1 mol dm−3 and −52.6 mV decade−1). Selectivity coefficients for different anions with respect to thiocyanate were calculated. The electrode E2 at pH 5.6 was also used for the determination of SCN by potentiometric titrations with Ag+ ions with good results. The electrode E2 was also used to determine concentrations of thiocyanate in biological samples.  相似文献   

16.
High-performance liquid chromatography (HPLC) with tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection methodology is reported for the determination of the atypical antipsychotic drug quetiapine and the observation of its major active and inactive metabolites in human urine and serum. The method uses a monolithic chromatographic column allowing high flow rates of 3 mL min−1 enabling rapid quantification. Flow injection analysis (FIA) with tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection and HPLC time of flight mass spectrometry (TOF-MS) were used for the determination of quetiapine in a pharmaceutical preparation to establish its suitability as a calibration standard. The limit of detection achieved with FIA was 2 × 10−11 mol L−1 in simple aqueous solution. The limits of detection achieved with HPLC were 7 × 10−8 and 2 × 10−10 mol L−1 in urine and serum, respectively. The calibration range for FIA was between 5 × 10−9 and 1 × 10−6 mol L−1. The calibration ranges for HPLC were between 1 × 10−7-1 × 10−4 and 1 × 10−8-1 × 10−4 mol L−1 in urine and serum, respectively. The quetiapine concentrations in patient samples were found to be 3 × 10−6 mol L−1 in urine and 7 × 10−7 mol L−1 in serum. Without the need for preconcentration, the HPLC detection limits compared favourably with those in previously published methodologies. The metabolites were identified using HPLC-TOF-MS.  相似文献   

17.
A new sensor for simultaneous determination of peroxyacetic acid and hydrogen peroxide using silver nanoparticles (Ag-NPs) as a chromogenic reagent is introduced. The silver nanoparticles have the catalytic ability for the decomposition of peroxyacetic acid and hydrogen peroxide; then the decomposition of them induces the degradation of silver nanoparticles. Hence, a remarkable change in the localized surface plasmon resonance absorbance strength could be observed. Spectra-kinetic approach and artificial neural network was applied for the simultaneous determination of peroxyacetic acid and hydrogen peroxide. Linear calibration graphs were obtained in the concentration range of (8.20 × 10−5 to 2.00 × 10−3 mol L−1) for peroxyacetic acid and (2.00 × 10−5 to 4.80 × 10−3 mol L−1) for hydrogen peroxide. The analytical performance of this sensor has been evaluated for the detection of simultaneous determination of peroxyacetic acid and hydrogen peroxide in real samples.  相似文献   

18.
Nalidixic acid (NA) and its main metabolite, 7-hydroximethylnalidixic acid (OHNA), are quinolones antibacterial used as agents used for the treatment of urinary tract infection. For both compounds an adsorption process on a hanging mercury electrode (HMDE). On this basis, a square wave adsorptive stripping voltammetry (SWadSV) method has been developed for the individual and simultaneous determination of NA and OHNA. The variables that affect to accumulation process, such as concentration of perchloric acid, accumulation potential and accumulation time have been optimised by using an experimental design (concretely a Box-Behnken design with three levels) together with the response surface methodology (RSM). Calibration curves were linear in the range (0-1.38) × 10−7 mol L−1 for NA and (0-3.23) × 10−8 mol L−1 for OHNA, in the optimized conditions, with detection limits of 9.48 × 10−9 mol L−1 and 8.06 × 10−10 mol L−1 for NA and OHNA, respectively. The method was applied to urine samples containing only one of the analytes with satisfactory recoveries. As the voltammetric signals of these compounds show a high overlapping, different chemometric methods, such as classical least squares (CLS), partial least squares (PLS), principal component regression (PCR) and artificial neural network (ANN) have been used for the resolution of the mixture. The analysis of these compounds in urine samples were carried out using the different chemometric tools and the best recoveries were obtained by using ANN. No pre-treatment of the sample was necessary.  相似文献   

19.
Yoichi M.A Yamada 《Tetrahedron》2004,60(18):4097-4105
The efficient heterogeneous Heck reaction was achieved by a new networked and supramolecular catalyst PdAS-V (1b). Employing of PdAS-V in 5.0×10−5 mol equiv. efficiently progressed the heterogeneous Heck reaction of a series of aryl iodides with acrylates, styrenes and acrylic acid. PdAS-V was successfully recycled five times without any decrease in its activity, and showed good stability in toluene and water, and hence the Heck reaction was efficiently performed in both reaction media. The use of 8.0×10−7 mol equiv. of PdAS-V resulted in the coupling product in 92% yield with the turnover number (TON) and the turnover frequency (TOF) of PdAS-V reached up to 1,150,000 and 12,000, respectively. The efficient synthesis of resveratrol was achieved via the PdAS-V-promoted Heck reaction.  相似文献   

20.
Ding SN  Xu JJ  Zhang WJ  Chen HY 《Talanta》2006,70(3):572-577
Tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+)-Zirconia-Nafion composite modified glassy carbon disk electrode as a solid-state electrochemiluminescence (ECL) detector is successfully applied to an electrophoretic microchip system with a wall-jet configuration. Pharmaceuticals such as tramadol, lidocaine and ofloxacin were selected to characterize the performance of this microchip capillary electrophoresis (CE)-ECL detection system. Voltammetric and ECL behaviors of immobilized Ru(bpy)32+ were investigated in lidocaine system. Influences of the separation electric field to cyclic voltammograms (CVs) of the immobilized Ru(bpy)32+ were also investigated. Tramadol, lidocaine and ofloxacin can be baseline separated without any additives. The detection limits (S/N = 3) were 2.5 × 10−5 mol L−1 for tramadol, 5.0 × 10−6 mol L−1 for lidocaine, 1.0 × 10−5 mol L−1 for ofloxacin under the sample injection of picoliters, and the linear ranges were from 5.0 × 10−5 to 2.5 × 10−3 mol L−1 for tramadol, 1.0 × 10−5 to 1.0 × 10−3 mol L−1 for lidocaine, and 1.0 × 10−5 to 2.5 × 10−3 mol L−1 for ofloxacin, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号