首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this study, we explored the MS/MS behavior of various synthetic peptides that possess a lysine residue at the N-terminal position. These peptides were designed to mimic peptides produced upon proteolysis by the Lys-N enzyme, a metalloendopeptidase issued from a Japanese fungus Grifola frondosa that was recently investigated in proteomic studies as an alternative to trypsin digestion, as a specific cleavage at the amide X-Lys chain is obtained that provides N-terminal lysine peptide fragments. In contrast to tryptic peptides exhibiting a lysine or arginine residue solely at the C-terminal position, and are thus devoid of such basic amino acids within the sequence, these Lys-N proteolytic peptides can contain the highly basic arginine residue anywhere within the peptide chain. The fragmentation patterns of such sequences with the ESI-QqTOF and MALDI-TOF/TOF mass spectrometers commonly used in proteomic bottom-up experiments were investigated.  相似文献   

2.
The decision peptide-driven tool implements a software application for assisting the user in a protocol for accurate protein quantification based on the following steps: (1) protein separation through gel electrophoresis; (2) in-gel protein digestion; (3) direct and inverse 18O-labeling and (4) matrix assisted laser desorption ionization time of flight mass spectrometry, MALDI analysis. The DPD software compares the MALDI results of the direct and inverse 18O-labeling experiments and quickly identifies those peptides with paralleled loses in different sets of a typical proteomic workflow. Those peptides are used for subsequent accurate protein quantification. The interpretation of the MALDI data from direct and inverse labeling experiments is time-consuming requiring a significant amount of time to do all comparisons manually. The DPD software shortens and simplifies the searching of the peptides that must be used for quantification from a week to just some minutes. To do so, it takes as input several MALDI spectra and aids the researcher in an automatic mode (i) to compare data from direct and inverse 18O-labeling experiments, calculating the corresponding ratios to determine those peptides with paralleled losses throughout different sets of experiments; and (ii) allow to use those peptides as internal standards for subsequent accurate protein quantification using 18O-labeling. In this work the DPD software is presented and explained with the quantification of protein carbonic anhydrase.  相似文献   

3.
This paper focuses on the sequential steps involved in developing a technique for quantifying Greenland halibut vitellogenin, a serum protein biomarker, using a comprehensive mass spectrometric approach. In the first phase of this study, in‐gel trypsin digestions of serum proteins separated by sodium dodecyl sulphate polyacrylamide gel electrophoresis (SDS‐PAGE) were analyzed by matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS). A characteristic band around a molecular mass of 185 kDa, present in the mature female specimens, but absent in the male samples, was identified as vitellognin according to the peptide mass fingerprint obtained by MALDI‐MS. Subsequently, MALDI and electrospray ionization tandem mass spectrometry (ESI‐MS/MS) analyses were performed on the digest of the vitellogenin band for de novo sequencing. From these studies, a characteristic 'signature' peptide (sequence: FFGQEIAFANIDK) was selected from a list of candidate peptides as a surrogate analytical standard used for quantification purposes. Sample preparation for vitellogenin quantification consisted of a simple one‐step overnight trypsin digestion. Samples were spiked with an isotopologue signature peptide standard and analyzed by high‐performance liquid chromatography (HPLC) coupled in‐line to an electrospray quadrupole‐hexapole‐quadrupole tandem mass spectrometer, operated in selective reaction monitoring mode. Transitions [(m/z 750.0 → 1020.4 and 750.0 → 1205.4) and (754.8 → 1028.6 and 754.8 → 1213.2)] were monitored for the signature peptide and the internal standard, respectively. Samples obtained from the field showed that vitellogenin levels were in accordance with fish maturity determined by macroscopic examination of the gonad, proving this technique suitable for measuring vitellogenin as a serum protein biomarker for reproductive maturity in female fish. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Proteomics requires an optimized level of sample-processing, including a minimal sample-processing time and an optimal peptide recovery from protein digests, in order to maximize the percentage sequence coverage and to improve the accuracy of protein identification. The conventional methods of protein characterization from one-dimensional or two-dimensional gels include the destaining of an excised gel piece, followed by an overnight in-gel enzyme digestion. The aims of this study were to determine whether: (1) stained gels can be used without any destaining for trypsin digestion and mass spectrometry (MS); (2) tryptic peptides can be recovered from a matrix-assisted laser desorption/ionization (MALDI) target plate for a subsequent analysis with liquid chromatography (LC) coupled to an electrospray ionization (ESI) quadrupole ion trap MS; and (3) an overnight in-gel digestion is necessary for protein characterization with MS. These three strategies would significantly improve sample throughput. Cerebrospinal fluid (CSF) was the model biological fluid used to develop these methods. CSF was desalted by gel filtration, and CSF proteins were separated by two-dimensional gel electrophoresis (2DGE). Proteins were visualized with either silver, Coomassie, or Stains-All (counterstained with silver). None of the gels was destained. Protein spots were in-gel trypsin digested, the tryptic peptides were purified with ZipTip, and the peptides were analyzed with MALDI and ESI MS. Some of the samples that were spotted onto a wax-coated MALDI target plate were recovered and analyzed with ESI MS. All three types of stained gels were compatible with MALDI and ESI MS without any destaining. In-gel trypsin digestion can be performed in only 10-60 min for protein characterization with MS, the sample can be recovered from the MALDI target plate for use in ESI MS, and there was a 90% reduction in sample-processing time from overnight to ca. 3 h.  相似文献   

5.
Mass spectrometric plasma analysis for biomarker discovery has become an exploratory focus in proteomic research: the challenges of analyzing plasma samples by mass spectrometry have become apparent not only since the human proteome organization (HUPO) has put much emphasis on the human plasma proteome. This work demonstrates fundamental proteomic research to reveal sensitivity and quantification capabilities of our Peptidomics technologies by detecting distinct changes in plasma peptide composition in samples after challenging healthy volunteers with orally administered glucose. Differential Peptide Display (DPD) is a technique for peptidomics studies to compare peptides from distinct biological samples. Mass spectrometry (MS) is used as a qualitative and quantitative analysis tool without previous trypsin digestion or labeling of the samples. Circulating peptides (< 15 kDa) were extracted from 1.3 mL plasma samples and the extracts separated by liquid chromatography into 96 fractions. Each fraction was subjected to MALDI MS, and mass spectra of all fractions were combined resulting in a 2D-display of > 2,000 peptides from each sample. Endogenous peptides that responded to oral glucose challenge were detected by DPD of pre-and post-challenge plasma samples from 16 healthy volunteers and subsequently identified by nESI-qTOF MS. Two of the 15 MS peaks that were significantly modulated by glucose challenge were subsequently identified as insulin and C-peptide. These results were validated by using immunoassays for insulin and C-peptide. This paper serves as a proof of principle for proteomic biomarker discovery down to the pM concentration range by using small amounts of human plasma.  相似文献   

6.
By screening a data set of 392 synthetic peptides MS/MS spectra, we found that a known C-terminal rearrangement was unexpectedly frequently occurring from monoprotonated molecular ions in both ESI and MALDI tandem mass spectrometry upon low and high energy collision activated dissociations with QqTOF and TOF/TOF mass analyzer configuration, respectively. Any residue localized at the C-terminal carboxylic acid end, even a basic one, was lost, provided that a basic amino acid such arginine and to a lesser extent histidine and lysine was present in the sequence leading to a fragment ion, usually depicted as (bn-1 + H2O) ion, corresponding to a shortened non-scrambled peptide chain. Far from being an epiphenomenon, such a residue exclusion from the peptide chain C-terminal extremity gave a fragment ion that was the base peak of the MS/MS spectrum in certain cases. Within the frame of the mobile proton model, the ionizing proton being sequestered onto the basic amino acid side chain, it is known that the charge directed fragmentation mechanism involved the C-terminal carboxylic acid function forming an anhydride intermediate structure. The same mechanism was also demonstrated from cationized peptides. To confirm such assessment, we have prepared some of the peptides that displayed such C-terminal residue exclusion as a C-terminal backbone amide. As expected in this peptide amide series, the production of truncated chains was completely suppressed. Besides, multiply charged molecular ions of all peptides recorded in ESI mass spectrometry did not undergo such fragmentation validating that any mobile ionizing proton will prevent such a competitive C-terminal backbone rearrangement. Among all well-known nondirect sequence fragment ions issued from non specific loss of neutral molecules (mainly H2O and NH3) and multiple backbone amide ruptures (b-type internal ions), the described C-terminal residue exclusion is highly identifiable giving raise to a single fragment ion in the high mass range of the MS/MS spectra. The mass difference between this signal and the protonated molecular ion corresponds to the mass of the C-terminal residue. It allowed a straightforward identification of the amino acid positioned at this extremity. It must be emphasized that a neutral residue loss can be misattributed to the formation of a ym-1 ion, i.e., to the loss of the N-terminal residue following the a1-ym–1 fragmentation channel. Extreme caution must be adopted when reading the direct sequence ion on the positive ion MS/MS spectra of singly charged peptides not to mix up the attribution of the N- and C-terminal amino acids. Although such peculiar fragmentation behavior is of obvious interest for de novo peptide sequencing, it can also be exploited in proteomics, especially for studies involving digestion protocols carried out with proteolytic enzymes other than trypsin (Lys-N, Glu-C, and Asp-N) that produce arginine-containing peptides.  相似文献   

7.
Protein identification is routinely accomplished by peptide sequencing using mass spectrometry (MS) after enzymatic digestion. Site-specific chemical modification may improve peptide ionization efficiency or sequence coverage in mass spectrometry. We report herein that amino group of lysine residue in peptides can be selectively modified by reaction with a peroxycarbonate and the resulting lysine peroxycarbamates undergo homolytic fragmentation under conditions of low-energy collision-induced dissociation (CID) in electrospray ionization (ESI) and matrix-assisted laser desorption and ionization (MALDI) MS. Selective modification of lysine residue in peptides by our strategy can induce specific peptide cleavage at or near the lysine site. Studies using deuterated analogues of modified lysine indicate that fragmentation of the modified peptides involves apparent free-radical processes that lead to peptide chain fragmentation and side-chain loss. The formation of a-, c-, or z-types of ions in MS is reminiscent of the proposed free-radical mechanisms in low-energy electron capture dissociation (ECD) processes that may have better sequence coverage than that of the conventional CID method. This site-specific cleavage of peptides by free radical- promoted processes is feasible and such strategies may aid the protein sequencing analysis and have potential applications in top-down proteomics.  相似文献   

8.
赖氨酸胍基化在蛋白质组学定性和定量研究中起着重要作用,本文系统分析了胍基化前后,HeLa细胞蛋白质经胰蛋白酶酶解产生的3种不同类型肽段的质谱鉴定情况,并探讨了不同肽段质谱响应改变的内在原因。发现赖氨酸在侧链能选择性地发生胍基化反应(其选择性达到96.8%),转化为高精氨酸,碱性增强。因此在正离子质谱模式下,C端为赖氨酸的肽段产生了更多的y离子,提供了许多新的离子碎片信息。在鉴定结果中,此类肽段所占总肽段的比例由原来的51.7%上升为57.3%,并且有1015条新的肽段被检测到。对于不含有赖氨酸的肽段,其鉴定结果在胍基化前后基本没有变化。结果表明,胍基化可以在一定程度上提高质谱鉴定的灵敏度和互补性,提高蛋白质分析的覆盖率。  相似文献   

9.
We have developed a new method to determine the N-terminal amino acid sequences of proteins, regardless of whether their N-termini are modified. This method consists of the following five steps: (1) reduction, S-alkylation and guanidination for targeted proteins; (2) coupling of sulfo-NHS-SS-biotin to N(alpha)-amino groups of proteins; (3) digestion of the modified proteins by an appropriate protease followed by oxidation with performic acid; (4) specific isolation of N-terminal peptides from digests using DITC resins; (5) de novo sequence analysis of the N-terminal peptides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) using the CAF (chemically assisted fragmentation) method or tandem mass spectrometric (MS/MS) analysis according to unblocked or blocked peptides, respectively. By employing DITC resins instead of avidin resins used in our previous method (Yamaguchi et al., Rapid Commun. Mass Spectrom. 2007; 21: 3329), it has been possible to isolate selectively N-terminal peptides from proteins regardless of modification of N-terminal amino acids. Here we propose a universal method for N-terminal sequence analysis of proteins.  相似文献   

10.
The rapid and specific detection of therapeutically important ligands in complex mixtures, that may bind to membrane proteins, remains challenging for many research laboratories and pharmaceutical industries. Through its use in the development of screening assays, mass spectrometry (MS) is currently experiencing a period of tremendous expansion. In the study presented here, we took advantage of the remarkable stability properties of a bacterial membrane protein, the KcsA K+ channel, produced in E. coli and purified as a tetrameric protein in the presence of a detergent. This membrane protein can subserve as a molecular template to display the pore‐forming region of human K+ channels, which are considered as targets in the search for inhibitory ligands. The engineered chimeric proteins were linked to metal‐bound magnetic beads, for the screening of complex peptide mixtures, such as that of scorpion venoms. The affinity‐captured scorpion toxins were eluted prior to matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOFMS), and to nano‐electrospray ionization tandem mass QqTOF mass spectrometry (MS/MS) analysis. The de novo sequence of the toxins was deduced by combining the MS/MS fragmentation of the reduced form (up to the 33 first residues) and the trypsin digest peptides of the native toxins. This affinity‐capture screening assay led to the isolation and characterization of potent and specific ligands of the human K+ channel, Kv1.3. The affinity‐capture procedure is fast and reproducible. When linked to magnetic beads, the chimeric membrane protein can be re‐used several times without losing any of its selectivity or specificity. This assay also benefits from the fact that it requires minimal amounts of animal venoms or complex mixtures, which can be expensive or difficult to procure. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
The spatial distribution of proteins in tissue sections can be used to identify potential markers for pathological processes. Tissue sections are often subjected to enzymatic digestion before matrix‐assisted laser desorption/ionization (MALDI) imaging. This study is targeted at improving the on‐tissue identification of tryptic peptides by accurate mass measurements and complementary off‐line liquid chromatography coupled to electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) analysis. Two adjacent mouse brain sections were analyzed in parallel. The first section was spotted with trypsin and analyzed by MALDI imaging. Direct on‐tissue MS/MS experiments of this section resulted in the identification of 14 peptides (originating from 4 proteins). The second tissue section was homogenized, fractionated by ultracentrifugation and digested with trypsin prior to LC/ESI‐MS/MS analysis. The number of identified peptides was increased to 153 (corresponding to 106 proteins) by matching imaged mass peaks to peptides which were identified in these LC/ESI‐MS/MS experiments. All results (including MALDI imaging data) were based on accurate mass measurements (RMS <2 ppm) and allow a confident identification of tryptic peptides. Measurements based on lower accuracy would have led to ambiguous or misleading results. MS images of identified peptides were generated with a bin width (mass range used for image generation) of Δm/z = 0.01. The application of accurate mass measurements and additional LC/MS measurements increased both the quality and the number of peptide identifications. The advantages of this approach for the analysis of biological tissue sections are demonstrated and discussed in detail. Results indicate that accurate mass measurements are needed for confident identification and specific image generation of tryptic peptides in tissue sections. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
Trypsin digestion is a major component of preparing proteins for peptide based identification and quantification by mass spectral (MS) analysis. Surprisingly proteolysis is the slowest part of the proteomics process by an order of magnitude. Numerous recent efforts to reduce protein digestion to a few minutes have centered on the use of an immobilized enzyme reactor (IMER) to minimize both trypsin autolysis and vastly increase the trypsin to protein ratio. A central question in this approach is whether proteolysis with an IMER produces the same peptide cleavage products as derived from solution based digestion. The studies reported here examined this question with transferrin; a model protein of known resistance to trypsin digestion. Results from these studies confirmed that a trypsin‐IMER can in fact digest transferrin in a few minutes; providing tryptic peptides that subsequent to MS analysis allow sequence identification equivalent to solution digestion. Although many of the peptides obtained from these two trypsin digestion systems were identical, many were not. The greatest difference was that the trypsin‐ IMER produces (i) numerous peptides bearing multiple lysine and/or arginine residues and (ii) identical portions of the protein sequence were found in multiple peptides. Most of these peptides were derived from five regions in transferrin. These results were interpreted to mean that proteolysis in the case of transferrin occurred faster than the rate at which buried lysine and arginine residues were unmasked in the five regions providing peptides that were only partially digested.  相似文献   

13.
To address immunocapture of proteins in large cohorts of clinical samples high throughput sample processing is required. Here a method using the proteomic sample platform, ISET (integrated selective enrichment target) that integrates highly specific immunoaffinity capture of protein biomarker, digestion and sample cleanup with a direct interface to mass spectrometry is presented. The robustness of the on-ISET protein digestion protocol was validated by MALDI MS analysis of model proteins, ranging from 40 fmol to 1 pmol per nanovial. On-ISET digestion and MALDI MS/MS analysis of immunoaffinity captured disease-associated biomarker PSA (prostate specific antigen) from human seminal plasma are presented.  相似文献   

14.
While surfactants are commonly used in preparing protein samples, their presence in a protein sample can potentially affect the enzymatic digestion process and the subsequent analysis of the resulting peptides by mass spectrometry. The extent of the tolerance of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) to surfactant interference in peptide analysis is very much dependent on the matrix/sample preparation method. In this work the effects of four commonly used surfactants, namely n-octyl glucoside (OG), Triton X-100 (TX-100), 3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulfonate (CHAPS) and sodium dodecyl sulfate (SDS), for biological sample preparation on trypsin digestion and MALDI-MS of the resulting digest are examined in detail within the context of using a two-layer method for MALDI matrix/sample preparation. Non-ionic and mild surfactants, such as OG, TX-100 or CHAPS, are found to have no significant effect on trypsin digestion with surfactant concentrations up to 1%. However, TX-100 and CHAPS interfere with the subsequent peptide analysis by MALDI-MS and should be removed prior to peptide analysis. OG is an MS-friendly surfactant and no effect is observed for MALDI peptide analysis. The effect of SDS on trypsin digestion in terms of the number of peptides generated and the overall protein sequence coverage by these peptides is found to be protein dependent. The use of SDS to solubilize hydrophobic membrane proteins, followed by trypsin digestion in the presence of 0.1% SDS, results in a peptide mixture that can be analyzed directly by MALDI-MS. These peptides are shown to provide better sequence coverage compared with those obtained without the use of SDS in the case of bacteriorhodopsin, a very hydrophobic transmembrane protein. This work illustrates that MALDI-MS with the two-layer sample preparation method can be used for direct analysis of protein digests with no or minimum sample cleanup after proteins are digested in a solution containing surfactants.  相似文献   

15.
In this work, partial characterization of the primary structure of phycocyanin from the cyanobacterium Aphanizomenon flos‐aquae (AFA) was achieved by mass spectrometry de novo sequencing with the aid of chemical derivatization. Combining N‐terminal sulfonation of tryptic peptides by 4‐sulfophenyl isothiocyanate (SPITC) and MALDI‐TOF/TOF analyses, facilitated the acquisition of sequence information for AFA phycocyanin subunits. In fact, SPITC‐derivatized peptides underwent facile fragmentation, predominantly resulting in y‐series ions in the MS/MS spectra and often exhibiting uninterrupted sequences of 20 or more amino acid residues. This strategy allowed us to carry out peptide fragment fingerprinting and de novo sequencing of several peptides belonging to both α‐ and β‐phycocyanin polypeptides, obtaining a sequence coverage of 67% and 75%, respectively. The presence of different isoforms of phycocyanin subunits was also revealed; subsequently Intact Mass Measurements (IMMs) by both MALDI‐ and ESI‐MS supported the detection of these protein isoforms. Finally, we discuss the evolutionary importance of phycocyanin isoforms in cyanobacteria, suggesting the possible use of the phycocyanin operon for a correct taxonomic identity of this species. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

16.
Peptide tagging is a useful tool to improve matrix‐assisted laser desorption/ionization tandem mass spectrometric (MALDI‐MS/MS) analysis. We present a new application of the use of the dansyl chloride (DNS‐Cl). DNS‐Cl is a specific primary amine reagent widely used in protein biochemistry. It adds a fluorescent dimethylaminonaphthalene moiety to the molecule. The evaluation of MALDI‐MS and MS/MS analyses of dansylated peptides shows that dansylation raises the ionization efficiency of the most hydrophilic species compared with the most hydrophobic ones. Consequently, higher Mascot scores and protein sequence coverage are obtained by combining MS and MS/MS data of native and tagged samples. The N‐terminal DNS‐Cl sulfonation improves the peptide fragmentation and promotes the generation of b‐fragments allowing better peptide sequencing. In addition, we set up a labeling protocol based on the microwave chemistry. Peptide dansylation proved to be a rapid and cheap method to improve the performance of liquid chromatography (LC)/MALDI‐MS/MS analysis at the proteomic scale in terms of peptide detection and sequence coverage. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
The use of chemical crosslinking is an attractive tool that presents many advantages in the application of mass spectrometry to structural biology. The correct assignment of crosslinked peptides, however, is still a challenge because of the lack of detailed fragmentation studies on resultant species. In this work, the fragmentation patterns of intramolecular crosslinked peptides with disuccinimidyl suberate (DSS) has been devised by using a set of versatile, model peptides that resemble species found in crosslinking experiments with proteins. These peptides contain an acetylated N-terminus followed by a random sequence of residues containing two lysine residues separated by an arginine. After the crosslinking reaction, controlled trypsin digestion yields both intra- and intermolecular crosslinked peptides. In the present study we analyzed the fragmentation of matrix-assisted laser desorption/ionization-generated peptides crosslinked with DSS in which both lysines are found in the same peptide. Fragmentation starts in the linear moiety of the peptide, yielding regular b and y ions. Once it reaches the cyclic portion of the molecule, fragmentation was observed to occur either at the following peptide bond or at the peptide crosslinker amide bond. If the peptide crosslinker bond is cleaved, it fragments as a regular modified peptide, in which the DSS backbone remains attached to the first lysine. This fragmentation pattern resembles the fragmentation of modified peptides and may be identified by common automated search engines using DSS as a modification. If, on the other hand, fragmentation happens at the peptide bond itself, rearrangement of the last crosslinked lysine is observed and a product ion containing the crosslinker backbone and lysine (m/z 222) is formed. The detailed identification of fragment ions can help the development of softwares devoted to the MS/MS data analysis of crosslinked peptides.  相似文献   

18.
We present the MALDI‐TOF/TOF‐MS analyses of various hapten–bovine serum albumin (BSA) neoglycoconjugates obtained by squaric acid chemistry coupling of the spacer‐equipped, terminal monosaccharide of the O‐specific polysaccharide of Vibrio cholerae O1, serotype Ogawa, to BSA. These analyses allowed not only to calculate the molecular masses of the hapten–BSA neoglycoconjugates with different hapten–BSA ratios (4.3, 6.6 and 13.2) but, more importantly, also to localize the covalent linkages (conjugation sites) between the hapten and the carrier protein. Determination of the site of glycation was based on comparison of the MALDI‐TOF/TOF‐MS analysis of the peptides resulting from the digestion of BSA with similar data resulting from the digestion of BSA glycoconjugates, followed by sequencing by MALDI‐TOF/TOF‐MS/MS of the glycated peptides. The product‐ion scans of the protonated molecules were carried out with a MALDI‐TOF/TOF‐MS/MS tandem mass spectrometer equipped with a high‐collision energy cell. The high‐energy collision‐induced dissociation (CID) spectra afforded product ions formed by fragmentation of the carbohydrate hapten and amino acid sequences conjugated with fragments of the carbohydrate hapten. We were able to identify three conjugation sites on lysine residues (Lys235, Lys437 and Lys455). It was shown that these lysine residues are very reactive and bind lysine specific reagents. We presume that these Lys residues belong to those that are considered to be sterically more accessible on the surface of the tridimensional structure. The identification of the y‐series product ions was very useful for the sequencing of various peptides. The series of a‐ and b‐product ions confirmed the sequence of the conjugated peptides. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
Prefabricated surfaces containing α‐cyano‐4‐hydroxycinnamic acid and trypsin have been developed to facilitate enzymatic digestion of endogenous tissue proteins prior to matrix‐assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS). Tissue sections are placed onto slides that were previously coated with α‐cyano‐4‐hydroxycinnamic acid and trypsin. After incubation to promote enzymatic digestion, the tissue is analyzed by MALDI IMS to determine the spatial distribution of the tryptic fragments. The peptides detected in the MALDI IMS dataset were identified by Liquid chromatography‐tandem mass spectrometry/mass spectrometry. Protein identification was further confirmed by correlating the localization of unique tryptic fragments originating from common parent proteins. Using this procedure, proteins with molecular weights as large as 300 kDa were identified and their distributions were imaged in sections of rat brain. In particular, large proteins such as myristoylated alanine‐rich C‐kinase substrate (29.8 kDa) and spectrin alpha chain, non‐erythrocytic 1 (284 kDa) were detected that are not observed without trypsin. The pre‐coated targets simplify workflow and increase sample throughput by decreasing the sample preparation time. Further, the approach allows imaging at higher spatial resolution compared with robotic spotters that apply one drop at a time. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
Derivatization of tryptic peptides using an Ettan CAF matrix-assisted laser desorption/ionization (MALDI) sequencing kit in combination with MALDI-post source decay (PSD) is a fast, accurate and convenient way to obtain de novo or confirmative peptide sequencing data. CAF (chemically assisted fragmentation) is based on solid-phase derivatization using a new class of water stable sulfonation agents, which strongly improves PSD analysis and simplifies the interpretation of acquired spectra. The derivatization is performed on solid supports, ZipTip(microC18, limiting the maximum peptide amount to 5 microg. By performing the derivatization in solution enabled the labeling of tryptic peptides derived from 100 microg of protein. To increase the number of peptides that could be sequenced, derivatized peptides were purified using multidimensional liquid chromatography (MDLC) prior to MALDI sequencing. Following the first dimension strong cation exchange (SCX) chromatography step, modified peptides were separated using reversed-phase chromatography (RPC). During the SCX clean up step, positively charged peptides are retained on the column while properly CAF-derivatized peptides (uncharged) are not. A moderately complex tryptic digest, prepared from six different proteins of equimolar amounts, was CAF-derivatized and purified by MDLC. Fractions from the second dimension nano RPC step were automatically sampled and on-line dispensed to MALDI sample plates and analyzed using MALDI mass spectrometry fragmentation techniques. All proteins in the derivatized protein mixture digest were readily identified using MALDI-PSD or MALDI tandem mass spectrometry (MS/MS). More than 40 peptides were unambiguously sequenced, representing a seven-fold increase in the number of sequenced peptides in comparison to when the CAF-derivatized protein mix digest was analyzed directly (no MDLC-separation) using MALDI-PSD. In conclusion, MDLC purification of CAF-derivatized peptides significantly increases the success rate for de novo and confirmative sequencing using various MALDI fragmentation techniques. This new approach is not only applicable to single protein digests but also to more complex digests and could, thus, be an alternative to electrospray ionization MS/MS for peptide sequencing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号