1.
Caslavska J  Jung B  Thormann W 《Electrophoresis》2011,32(13):1760-1764
CZE coupled to sheath liquid-based electrospray ionization (ESI) and multiple-stage ion trap mass spectrometry (MS(n) ) was used for the confirmation analysis of ethyl glucuronide (EtG) and ethyl sulfate (EtS) in human serum and urine collected after intake of alcoholic beverages. Electrophoretic separations were performed in uncoated fused-silica capillaries using a pH 9.5 ammonium acetate background electrolyte and normal polarity. MS detection of EtG and EtS occurred after negative ionization using a spray liquid containing 0.5%?v/v ammonia in isopropanol/water (60:40%, v/v). CZE-MS and CZE-MS2 results obtained after injection of solid-phase extracts for EtG and EtS and of diluted urine confirmed the presence of EtG and EtS in samples whose levels were previously determined by CZE with indirect UV detection. Detection limits of each compound were estimated to be around 2.0 (injection of diluted urine) and 0.2?μg/mL (extracts).  相似文献   

2.
Zheng J  Jann MW  Hon YY  Shamsi SA 《Electrophoresis》2004,25(13):2033-2043
A method of coupling capillary zone electrophoresis (CZE) with electrospray ionization-mass spectrometry (ESI-MS) detection has been developed for monitoring an antiepileptic drug, lamotrigine (LTG) in human plasma. The CZE-MS was developed in three stages: (i) CZE separation and ESI-MS detection of LTG and tyramine (TRM, internal standard) were simultaneously optimized by studying the influence of CZE background electrolyte (BGE) pH, BGE ionic strength, and nebulizer pressure of the MS sprayer; (ii) sheath liquid parameters, such as pH, ionic strength, organic modifier content, and flow rate of the sheath liquid, were systematically varied under optimum CZE-MS conditions developed in the first stage; (iii) MS sprayer chamber parameters (drying gas temperature and drying gas flow rate) were varied for the best MS detection of LTG. The developed assay was finally applied for the determination of LTG in plasma samples. The linear range of LTG in plasma sample assay was between 0.1-5.0 microg/mL with a limit of detection as low as 0.05 microg/mL and run time less than 6 min. Finally, the concentration-time profile of LTG in human plasma sample was found to correlate well when CZE-ESI-MS was compared to a more established method of high-performance liquid chromatography with ultraviolet detection.  相似文献   

3.
Monoclonal antibody (mAb) therapeutics attract the largest concern due to their strong therapeutic potency and specificity. The Fc region of mAbs is common to many new biotherapeutics as biosimilar, antibody drug conjugate or fusion protein. Fc region has consequences for Fc-mediated effector functions that might be desirable for therapeutic applications. As a consequence, there is a continuous need for improvement of analytical methods to enable fast and accurate characterization of biotherapeutics. Capillary zone electrophoresis-Mass spectrometry couplings (CZE-MS) appear really attractive methods for the characterization of biological samples. In this report, we used CZE-MS systems developed in house and native MS infusion to allow precise middle-up characterization of Fc/2 variant of cetuximab. Molecular weights were measured for three Fc/2 charge variants detected in the CZE separation of cetuximab subunits. Two Fc/2 C-terminal lysine variants were identified and separated. As the aim is to understand the presence of three peaks in the CZE separation for two Fc/2 subunits, we developed a strategy using CZE-UV/MALDI-MS and CZE-UV/ESI-MS to evaluate the role of N-glycosylation and C-terminal lysine truncation on the CZE separation. The chemical structure of N-glycosylation expressed on the Fc region of cetuximab does not influence CZE separation while C-terminal lysine is significantly influencing separation. In addition, native MS infusion demonstrated the characterization of Fc/2 dimers at pH 5.7 and 6.8 and the first separation of these dimers using CZE-MS.  相似文献   

4.
Capillary electrophoresis (CE) was interfaced with a quadrupole mass spectrometer, using pneumatically-assisted electrospray ionization (ESI) in order to analyze Ecstasy and derivatives in urine. The influence of the sheath liquid composition, including the type and the percentage of the organic solvent, as well as the nature of the conductive acid modifier, were examined in order to find optimal coupling conditions. A fractional factorial design was also used to optimize the electrospray experimental parameters, such as the nebulizing gas pressure, the electrospray voltage, the drying gas flow rate, the drying gas temperature, the skimmer voltage, and the sheath liquid flow rate. The separation conditions were optimized in terms of temperature, electrolyte concentration, percentage of organic modifier, as well as capillary type. Finally, the optimal CE-ESI-MS conditions were applied to the analysis of Ecstasy and other related amphetamines in urine samples, following a liquid-liquid extraction procedure.  相似文献   

5.
A peptide separation strategy that combines two-dimensional (2-D) liquid chromatography (LC)-capillary zone electrophoresis (CZE) with tandem mass spectrometry (MS/MS) is described for the identification of proteins in complex mixtures. To test the effectiveness of this strategy, a serum sample was depleted of the high-abundance proteins by methanol precipitation, digested with trypsin to generate a complex peptide mixture, and separated into 96 fractions by reversed-phase (RP)-LC. Compared to ion-exchange LC separations, RPLC provides much higher resolution and peak capacity. Fractions were collected off-line from the RPLC separation, and subjected to short 20 min CZE separations. The separated zones were introduced to the mass spectrometer through a sheathless electrospray ionization interface that is integrated on the separation capillary. The ease of fabrication of the interface and its durability allowed for the analysis of all fractions on a single capillary in a relatively short analysis time. A stable electrospray was produced at nanoliter flowrates by augmenting analyte electrophoretic and electroosmotic mobilities with pressure-assisted flow. Unlike first-dimensional ion-exchange LC fractionation, where there is a large degree of overlap, the CZE-MS results show less than 15% overlap between neighboring RPLC fractions.  相似文献   

6.
Eighteen positional isomers of chlorophenols were separated by capillary electrophoresis (CE) and detected on-line by electrospray ionization ion-trap mass spectrometry (MS). Conditions for the coupling of CE to MS, e.g., the concentration of carrier electrolyte, the sheath liquid composition and the sheath gas flow-rate were optimized. Diethylmalonic acid (5 mM) at pH 7.25 and isopropanol-250 mM dimethylamine (80:20) as sheath liquid were used. The activation parameters for ion-trap mass spectrometric analysis of chlorophenols were optimized. The mass spectra, obtained for all the analytes, revealed that the [M-H]- ion was the base peak for all chlorophenols. Moreover, conditions for CE-MS-MS detection were established and [M-H-HCl]- ions were detected.  相似文献   

7.
Peptide standards and tryptic digests of ribonuclease B are separated by comprehensive two-dimensional reversed phase liquid chromatography (RPLC) and capillary zone electrophoresis (CZE) and detected on-line by electrospray mass spectrometry. The RPLC column is coupled to the CZE column by a transverse flow gating interface. A new rugged microelectrospray needle is described that combines high ionization efficiency, low flow rates, and a sheath flow. The result is a system combining the separation capabilities of both RPLC and CZE with on-line mass spectrometric detection, all in about 15 min.  相似文献   

8.
The applicability of a capillary zone electrophoresis–electrospray ionisation tandem mass spectrometric (CZE–ESI-MS–MS) method for the separation of nine fluoroquinolones was investigated. Method optimisation involved systematic trouble-shooting starting with the type and duration of capillary pre-washing and conditioning, the choice of both the CE run buffer, MS sheath liquid, CE run potential, ESI spray voltage, sheath gas flow-rate, MS capillary voltage and CE capillary and MS capillary temperatures. Another extremely important factor was found to be the degree to which the CE capillary protrudes into the ESI chamber as well as whether or not sheath gas and spray voltage are employed during the CE injection or not. The importance of the latter has, to our knowledge, not been addressed elsewhere. Nine fluoroquinolones have been separated and detected in a single run by this technique.  相似文献   

9.
梁玉  张丽华  张玉奎 《色谱》2020,38(10):1117-1124
蛋白质组学研究在生物学、精准医学等方面发挥着重要的作用。然而研究面临的巨大挑战来自生物样品的复杂性,因此在质谱(MS)鉴定技术不断革新的同时,发展分离技术以降低样品复杂度尤为重要。毛细管电泳(CE)技术具有上样体积小、分离效率高、分离速度快等优势,其与质谱的联用在蛋白质组学研究中越来越受到关注。低流速鞘流液和无鞘流液接口的发展及商品化推动了CE-MS技术的发展。目前毛细管区带电泳(CZE)、毛细管等电聚焦(CIEF)、毛细管电色谱(CEC)等分离模式已与质谱联用,其中CZE-MS应用最广泛。目前被广泛采用的蛋白质组学研究策略主要是基于酶解肽段分离鉴定的"自下而上(bottom-up)"策略。首先,CE-MS技术对酶解肽段的检测灵敏度高达1 zmol,已成功应用于单细胞蛋白质组学;其次,毛细管电泳技术与反相液相色谱互补,为疏水性质相近的肽段(尤其是翻译后修饰肽段)的分离鉴定提供了新的途径。基于整体蛋白质分离鉴定的自上而下"top-down"策略可以直接获得更精准、更完整的蛋白质信息。CE技术在蛋白质大分子的分离方面具有分离效率高、回收率高的优势,其与质谱的联用提高了整体蛋白质的鉴定灵敏度和覆盖度。非变性质谱(native MS)是一种在近生理条件下从完整蛋白质复合物水平上进行分析的质谱技术。CE与非变性质谱联用已被尝试用于蛋白质复合体的分离鉴定。该文引用了与CE-MS和蛋白质组学应用相关的93篇文献,综述了以上介绍的CE-MS的研究进展以及在蛋白质组学分析中的应用优势,并总结和展望了其应用前景。  相似文献   

10.
A generic approach has been developed for coupling capillary electrophoresis (CE) using non-volatile background electrolytes (BGEs) with mass spectrometry (MS) using a sheath liquid interface. CE-MS has been applied for basic and bi-functional compounds using a BGE consisting of 100 mM of TRIS adjusted to pH 2.5 using phosphoric acid. A liquid sheath effect is observed which may influence the CZE separation and hence may complicate the correlation between CE-UV and CE-MS methods. The influence of the liquid sheath effect on the migration behavior of basic pharmaceuticals has been studied by simulation experiments, in which the BGE outlet vial is replaced by sheath liquid in a CE-UV experiment. As a consequence of the liquid sheath effect, phosphate based BGEs can be used without significant loss of MS sensitivity compared to volatile BGEs. The use of buffer constituents such as TRIS can lead to lower detection limits as loss of MS sensitivity can be compensated by better CE performance. TRIS based BGEs permit relatively high injection amounts of about 100 pmol while maintaining high resolution. The ESI-MS parameters were optimized for a generic method with maximum sensitivity and stable operation, in which the composition of the sheath liquid and the position of the capillary were found to be important. Furthermore, the nebulizing pressure strongly influenced the separation efficiency. The system showed stable performance for several days and a reproducibility of about 15% RSD in peak area has been obtained. Nearly all test compounds used in this study could be analyzed with an MS detection limit of 0.05% measured in scan mode using extracted ion chromatograms. As a result, CE-MS was found to be a valuable analytical tool for pharmaceutical impurity profiling.  相似文献   

11.
We have developed a novel sheath-flow interface for low-flow electrospray ionization mass spectrometry (ESI-MS) and capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The interface is composed of two capillaries. One is a tapered fused-silica ESI emitter suitable for microliter and nanoliter flow rate electrospray and the other is a tail-end gold-coated CE separation column that is inserted into the emitter. A sheath liquid is supplied between the column and the emitter capillaries. The gold coating and the sheath liquid are used as the conducting media for ESI and the CE circuit. This novel design was initially evaluated by an infusion ESI-MS analysis of the most common antiretroviral dideoxynucleosides, followed by CE/MS coupling analysis of several antidepressant drugs. With infusion studies, the effects of the sheath liquid and the sample flow rates on detection sensitivity and signal stability were investigated. For an emitter with an internal diameter of 30 microm, the optimum flow rates for the sheath and the sample were 200 and 300 nL/min, respectively. The main improvement of this approach in comparison with conventional sheath liquid approaches using an ionspray interface is the gain in sensitivity. Sensitivities were three times better for dideoxynucleosides analyzed by infusion and 12 times higher for antidepressant drugs analyzed by CE/MS with this interface compared with ionspray. The emitter is durable, disposable, and simple to fabricate.  相似文献   

12.
Larsson M  Lutz ES 《Electrophoresis》2000,21(14):2859-2865
Transient isotachophoresic (ITP) focusing was used for the on-line analysis of peptides by capillary zone electrophoresis-mass spectrometry (CZE-MS), allowing injection volumes of up to 0.9 microL. A sheath liquid electrospray interface was used with a single quadrupole mass analyzer. First, the technique was applied to the qualitative analysis of a tryptic digest of cytochrome c, resulting in low-background, high-quality spectra. Second, the linear range was investigated by selected ion monitoring (SIM) for a peptidomimetic direct thrombin inhibitor melagatran (Mr 429.5) and two endogenous peptides, substance P (Mr 1348) and calcitonin gene-related peptide (alpha-CGRP; Mr 3806).  相似文献   

13.
The present study describes a reproducible and quantitative capillary zone electrophoresis (CZE) method, which leads to the separation of nine forms (native, oxidized and glycated) of human serum albumin (HSA). In an attempt to identify the different species separated by this CZE method, the capillary electrophoresis was coupled to mass spectrometry using a sheath liquid interface, an optimized capillary coating and a suitable CE running buffer. CE-MS analyses confirmed the heterogeneity of albumin preparation and revealed new truncated and modified forms such as Advanced Glycation End products (AGEs). Assignment of the CZE peaks was carried out using specific antibodies, carboxypeptidase A or sample reduction before or during the CE separation. Thus, five HSA forms were unambiguously identified. Using this CZE method several albumin batches produced by slightly different fractionation ways could be discriminated. Furthermore, analyses of HSA preparations marketed by five pharmaceutical industries revealed that two therapeutic albumins, including that marketed by LFB, contained the highest proportion of native form and lower levels of oxidized forms.  相似文献   

14.
Sixteen synthetic chemical drugs, often found in adulterated Chinese medicines, were studied by capillary electrophoresis/UV absorbance (CE/UV) and capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS). Only nine peaks were detected with CZE/UV, but on-line CZE/MS provided clear identification for most compounds. For a real sample of a Chinese medicinal preparation, a few adulterants were identified by their migration times and protonated molecular ions. For coeluting compounds, more reliable identification was achieved by MS/MS in selected reaction monitoring mode. Micellar electrokinetic chromatography (MEKC) using sodium dodecyl sulfate (SDS) provided better separation than capillary zone electrophoresis (CZE), and, under optimal conditions, fourteen peaks were detected using UV detection. In ESI, the interference of SDS was less severe in positive ion mode than in negative ion mode. Up to 20 mM SDS could be used in direct coupling of MEKC with ESI-MS if the mass spectrometer was operated in positive ion mode. Because of better resolution in MEKC, adulterants can be identified without the use of MS/MS.  相似文献   

15.
The capillary electrophoretic-mass spectrometric analysis (CE-MS) of catecholamines was optimized with coaxial sheath flow interface and electrospray ionization (ESI). The parameters studied included the sheath liquid composition and its flow rate, separation conditions in ammonium acetate buffer together with the ESI and cone voltages as mass spectrometric parameters. In addition, the effect of ESI voltage on injection as well as the siphoning effect were considered. The optimized conditions were a sheath liquid composition of methanol-water (80:20 v/v) with 0.5% acetic acid, with a flow rate of 6 microL/min. The capillary electrophoretic separation parameters were optimized with 50 mM ammonium acetate buffer, pH 4.0, to +25 kV separation voltage together with a pressure of 0.1 psi. The most intensive signals were obtained with an ESI voltage of +4.0 kV and a cone voltage of +20 V. The nonactive ESI voltage during injection as well as avoidance of the siphoning effect increased the sensitivity of the MS detection considerably. The use of ammonium hydroxide as the CE capillary conditioning solution instead of sodium hydroxide did not affect the CE-MS performance, but allowed the conditioning of the capillary between analyses to be performed in the MS without contaminating the ion source.  相似文献   

16.
Conditions for the simultaneous determination of the three herbicides paraquat, diquat and difenzoquat and the two plant growth regulators chlormequat and mepiquat by pressure-assisted capillary electrophoresis coupled to mass spectrometry (ion-trap) using electrospray as ionisation source have been established. A 200 mM formic acid-ammonium formate buffer solution at pH 3.0 with 50% of methanol was used as carrier electrolyte. Some capillary electrophoresis-mass spectrometry parameters such as sheath liquid and sheath gas flow-rates, sheath liquid composition, electrospray voltage andthe CE capillary position were optimised. The MS and MS-MS spectra of positive ions were studied in order to obtain structural information for the confirmation of the identity. The use of labelled standards allowed to confirm fragment ions assignation. The detection limits, based on a signal-to-noise ratio of 3:1, were between 0.5 and 2.5 mg l(-1) with hydrodynamic injection (10 s) and between 1 and 10 microg l(-1) with elecrokinetic injection (20 s, 10 kV) using standards in ultrapure water. Quality parameters such as linearity and run-to-run precision (n=6) were established. Quantitation was carried out using labelled standards. The method has been applied to the analysis of contaminated irrigation water and spiked mineral water samples.  相似文献   

17.
CZE-ESI-MS联用测定小肽混合物的研究   总被引:3,自引:0,他引:3  
研究肽的分离行为、测定方法及测定条件对蛋白质组学研究具有重要意义 .毛细管电泳 ( CE)作为一种高效、快速的分离方法 ,样品用量少 ,已被广泛应用于生物领域中 ,尤其是小肽和蛋白质的分离分析 .质谱 ( MS)能够进行微量鉴定 ,并提供精确的分子量和结构信息 ,使其成为小肽和蛋白质检测和序列测定的强有力的支撑技术之一 [1~ 3] .其中 ,电喷雾 ( ESI)质谱作为一种软电离技术 ,易与常规的高分辨率分离方法如高效液相色谱、毛细管电泳等实现在线联用 ,具有分离效率高、检测灵敏度高和样品定性方便等特点 ,因而在小肽和蛋白质的测定中得到广…  相似文献   

18.
Capillary electrophoresis (CE) coupled with electrospray ionization (ESI) mass spectrometry (MS) is a suitable technique for the analysis of intact proteins. The main configuration to realize this coupling is the sheath liquid interface, which is characterized by the addition of a make-up liquid providing the electric contact as well as the appropriate flow and solvent composition for optimal ionization and evaporation. One main advantage of this interface is that the composition of the sheath liquid can be tuned to modify the ionization without affecting CE selectivity and efficiency. In the case of protein ionization, this feature is particularly interesting to modulate their charge-state distribution (CSD), while keeping the separation performance unchanged.  相似文献   

19.
Amon S  Plematl A  Rizzi A 《Electrophoresis》2006,27(5-6):1209-1219
Defined conditions of EOF along with different pH values of the BGE were compared for the purpose of analyzing glycopetides by CZE coupled to MS (CZE-MS). Hyphenation to MS involved ESI as well as MALDI, and single-stage and multistage MS were applied. Variation of the EOF was accomplished by selecting appropriate coatings for the capillary, namely hexadimethrine bromide (HDMB) and HDMB/dextran sulfate. A high and reproducible anodic and cathodic EOF, respectively, was obtained in both approaches, allowing the detection of analytes with net positive as well as negative charge in one single run. Thus, a fast and sensitive determination of the glycopeptides in a tryptic digest of antithrombin, chosen as a test sample, was achieved. Ionization suppression effects, a phenomenon typically observed with glycopeptides in MS analysis, were minimized thanks to separation from other peptides present. The high stability of the coatings permitted the generation of mass spectra without interfering peaks originating from the coating polymers. The high EOF generated by the coatings facilitated the maintenance of a stable spray when coupling to ESI-MS, and a stable CZE current when working with a sheath flow-assisted analyte deposition onto MALDI targets, respectively. In conclusion, CZE-MS could be demonstrated as a robust complementary method to capillary RP-HPLC-MS in combination with both soft-ionization techniques, ESI and MALDI, generally, and particularly in the context of glycopeptide analysis.  相似文献   

20.
Nanoscale separation techniques, nanoscale packed capillary columns (75 μm id), and capillary zone electrophoresis (CZE), on-line with electrospray mass spectrometry (ESI/MS), were applied to the separation of a series of ten macrolide antibiotics. Both techniques use sub-microliter-per-minute flow rates through the analytical column and therefore require an electrospray probe that incorporates coaxial sheath flow. Positive ion electrospray mass spectra of these compounds yielded mainly protonated molecules. Fragmentation to yield structurally significant fragment ions was achieved by collision-induced dissociation (CID) at increased skimmer voltages. Separations were achieved using both techniques, with CZE/ESI/MS showing improved peak shapes and detection limits combined with faster analysis times. Nanoscale packed capillary columns provided better chromatographic resolution and was less susceptible to peak broadening caused by overloading of the analytes.  相似文献   