首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
The applicability of three different ionization techniques: atmospheric pressure photoionization (APPI), atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) was tested for the liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of five target pharmaceuticals (cyclophosphamide, methotrexate, bezafibrate, enalapril and orlistat) in wastewater samples. Performance was compared both by flow injection analysis (FIA) and on-column analysis in deionized water and wastewater samples. A column switching technique for the on-line extraction and analysis of water samples was used. For both FIA and on-column analysis, signal intensity and signal-to-noise (S/N) ratio of the target analytes in the three sources were studied. Limits of detection and matrix effects during the analysis of wastewater samples were also investigated. ESI generated significantly larger peak areas and higher S/N ratios than APCI and APPI in FIA and in on-column analysis. ESI was proved to be the most suitable ionization method as it enabled the detection of the five target compounds, whereas APCI and APPI ionized only four compounds.  相似文献   

2.
Analysis of 11 polybrominated diphenyl ethers (PBDEs), tetrabromobisphenol A bis 2,3-dibromopropylether (TBBPA-bis), tetrachlorobisphenol A (TCBPA), tetrabromobisphenol A (TBBPA) and hexabromocyclododecanes (HBCDs) was optimized by ultrahigh pressure liquid chromatography/tandem mass spectrometry (UPLC–MS/MS) operating in negative ion (NI) mode. Electrospray ionization (ESI), atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) sources were tested and for PBDEs APCI gave higher sensitivity than APPI while for TBBPA-bis APCI and APPI showed similar performance. ESI was the best option for TCBPA, TBBPA and HBCDs. Detection limits were between 20 and 59 fg for the compounds analyzed by ESI, 0.10 and 0.72 pg for PBDEs and 6 pg for TBBPA-bis. The matrix effect of sewage sludge extract was also tested showing negligible ion suppression for APCI and an increase of the background level of all investigated pollutants leading to a worsening of the limits of quantification by a factor between 1.2 and 3.3. The UPLC-APCI/MS/MS method for PBDEs, after pressurized liquid extraction (PLE), was validated by comparison with the concentration values from the NIST 1944 standard reference material. The advantages of the methods include low detection limits, PBDE congeners specificity using selected multiple reaction monitoring (MRM) transitions, and the absence of thermal degradation of higher PBDE congeners, especially BDE-209. The methods were applied for the determination of the above reported flame retardants in sewage sludge in order to get more information about the degradation on PBDEs (in particular BDE-209) during municipal wastewater treatments.  相似文献   

3.
The performance of the atmospheric pressure photoionization (APPI) technique was evaluated against five sets of standards and drug-like compounds and compared to atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The APPI technique was first used to analyze a set of 86 drug standards with diverse structures and polarities with a 100% detection rate. More detailed studies were then performed for another three sets of both drug standards and proprietary drug candidates. All 60 test compounds in these three sets were detected by APPI with an overall higher ionization efficiency than either APCI or ESI. Most of the non-polar compounds in these three sets were not ionized by APCI or ESI. Analysis of a final set of 201 Wyeth proprietary drug candidates by APPI, APCI and ESI provided an additional comparison of the ionization techniques. The detection rates in positive ion mode were 94% for APPI, 84% for APCI, and 84% for ESI. Combining positive and negative ion mode detection, APPI detected 98% of the compounds, while APCI and ESI detected 91%, respectively. This analysis shows that APPI is a valuable tool for day-to-day usage in a pharmaceutical company setting because it is able to successfully ionize more compounds, with greater structural diversity, than the other two ionization techniques. Consequently, APPI could be considered a more universal ionization method, and therefore has great potential in high-throughput drug discovery especially for open access liquid chromatography/mass spectrometry (LC/MS) applications.  相似文献   

4.
Various carotenoids were analyzed by ultra-high-pressure liquid chromatography with tandem mass spectrometry detection (UHPLC-MS/MS). Three different techniques to ionize the carotenoids were compared: electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). For all of the carotenoids tested, it was possible to obtain characteristic transitions for their unequivocal identification using each ionization technique. APCI was shown to be a more powerful technique to ionize the carotenoids than ESI or APPI. Transitions to differentiate carotenoids that coelute were determined to distinguish antheraxanthin from astaxanthin and lutein from zeaxanthin. In addition, four dopants were evaluated to improve ionization and enhance the carotenoid signal strength in APPI. These dopants were acetone, toluene, anisole, and chlorobenzene. Carotenoids improved their response in almost all cases when a dopant was used. The use of dopants allowed the enhancement of the carotenoid signals strength up to 178-fold.  相似文献   

5.
The high performance liquid chromatography (HPLC) separation methodology employed in the study of polyalkene additive compounds by atmospheric pressure ionization mass spectrometry (API-MS) was undertaken. Both atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) were examined. APPI (including dopant-assisted APPI) was found to be an inferior ionization technique to APCI in all cases. APCI ion responses were found to be highly dependent upon the organic solvent type used in the HPLC separations. Namely, employing a water/methanol gradient in place of a water/acetonitrile or a water/acetone gradient yielded improvements in analyte ion intensities between 2.3- and 52-fold for the liquid chromatography-mass spectrometry (LC-MS) experiments. Analyte and mobile phase solvent ionization energies were found to be only partially responsible, whereas mobile phase cluster formation and hydration was also implicated. Mobile phase component modification is demonstrated to be an important consideration when developing new, or modifying existing HPLC separations for use in LC-MS experiments in order to enhance analyte sensitivity for a wide variety of common polyalkene additives.  相似文献   

6.
This paper describes a comparison between atmospheric pressure chemical ionization (APCI) and the recently introduced atmospheric pressure photoionization (APPI) technique for the liquid chromatography/mass spectrometric (LC/MS) determination of patulin in clear apple juice. A column switching technique for on-line extraction of clear apple juice was developed. The parameters investigated for the optimization of APPI were the ion source parameters fragmentor voltage, capillary voltage, and vaporizer temperature, and also mobile phase composition and flow rate. Furthermore, chemical noise and signal suppression of analyte signals due to sample matrix interference were investigated for both APCI and APPI. The results indicated that APPI provides lower chemical noise and signal suppression in comparison with APCI. The linear range for patulin in apple juice (correlation coefficient >0.999) was 0.2-100 ng mL(-1). Mean recoveries of patulin in three apple juices ranged from 94.5 to 103.2%, and the limit of detection (S/N = 3), repeatability and reproducibility were 1.03-1.50 ng mL(-1), 3.9-5.1% and 7.3-8.2%, respectively. The total analysis time was 10.0 min.  相似文献   

7.
The most widely used ionization techniques in liquid chromatography-mass spectrometry (LC-MS) are electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). All three provide user friendly coupling of LC to MS. Achieving optimal LC-MS conditions is not always easy, however, owing to the complexity of ionization processes and the many parameters affecting mass spectrometric sensitivity and chromatographic performance. The selection of eluent composition requires particular attention since a solvent that is optimal for analyte ionization often does not provide acceptable retention and resolution in LC. Compromises must then be made between ionization and chromatographic separation efficiencies. The review presents an overview of studies concerning the effect of eluent composition on the ionization efficiency of ESI, APCI and APPI in LC-MS. Solvent characteristics are discussed in the light of ionization theories, and selected analytical applications are described. The aim is to provide practical background information for the development and optimization of LC-MS methods.  相似文献   

8.
The analytical hyphenation of micro-flow high-performance liquid chromatography (LC), with post-column liquid mixing and mass spectrometric detection (MS) was established to detect partially oxidized polycyclic aromatic hydrocarbons (oxy-PAHs) for low quantity samples. 100pmol injections of 30 reference standards could be detected in good sensitivity using either atmospheric pressure chemical ionization (APCI) and/or atmospheric pressure photoionization (APPI). The connected mass spectrometer was a single quadrupol analyzer realizing simultaneous registration of positive and negative ions in scan range width of 200 - 300Da. The ionization efficiency was compared using three ionization sources (incl. electrospray ionization (ESI)) for several oxy-PAHs. According to the mass spectra, the analytes behave differently in ionization properties. Ionization mechanism (e.g. deprotonated ions and electron captured ions) could be discussed with new inside views. Finally, the hyphenated system was applied to an exemplary aerosol extract and thus highlighting the expedient utilization of this downscaled method for real samples.  相似文献   

9.
The effect of nine different eluent compositions on the ionization efficiency of five flavonoids was studied using ion spray (IS), atmospheric pressure chemical ionization (APCI), and the novel atmospheric pressure photoionization (APPI), in positive and negative ion modes. The eluent composition had a great effect on the ionization efficiency, and the optimal ionization conditions were achieved in positive ion IS and APCI using 0.4% formic acid (pH 2.3) as a buffer, and in negative ion IS and APCI using ammonium acetate buffer adjusted to pH 4.0. For APPI work, the eluent of choice appeared to be a mixture of organic solvent and 5 mM aqueous ammonium acetate. The limits of detection (LODs) were determined in scan mode for the analytes by liquid chromatography/mass spectrometry using IS, APCI and APPI interfaces. The results show that negative ion IS with an eluent system consisting of acidic ammonium acetate buffer provides the best conditions for detection of flavonoids in mass spectrometry mode, their LODs being between 0.8 and 13 microM for an injection volume of 20 microl.  相似文献   

10.
Until recently, atmospheric pressure photoionization (APPI) has typically been used for the determination of non-polar halogenated flame retardants (HFRs) by liquid chromatography (LC) tandem mass spectrometry. In this study, we demonstrated the feasibility of utilizing liquid chromatography atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (LC-APCI-MS/MS) for analysis of 38 HFRs. This developed method offered three advantages: simplicity, rapidity, and high sensitivity. Compared with APPI, APCI does not require a UV lamp and a dopant reagent to assist atmospheric pressure ionization. All the isomers and the isobaric compounds were well resolved within 14-min LC separation time. Excellent instrument detection limits (6.1 pg on average with 2.0 μL injection) were observed. The APCI mechanism was also investigated. The method developed has been applied to the screening of wastewater samples for screening purpose, with concentrations determined by LC-APCI-MS/MS agreeing with data obtained via gas chromatography high resolution mass spectrometry.
Figure
LC-APCI-MS/MS for analysis of halogenated flame reterdants  相似文献   

11.
A method for the determination of polymer additives like antioxidants, UV absorbers and processing stabilizers using liquid chromatography (LC) coupled with atmospheric pressure photoionization mass spectrometry (APPI-MS) is presented. Ion source parameters were optimized regarding temperatures, gas flow rates, and voltages applied. Detection limits were determined using APPI with or without dopant and were compared with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). Differences between APPI, ESI and APCI are pointed out and the effect of the dopant toluene and acetone is discussed. The optimized method yielded detection limits between 0.001 mg L−1 and 0.022 mg L−1 for 15 different analytes. Linear calibration plots could be obtained for all solutes over a wide concentration range showing satisfying repeatability with standard deviations of peak areas between 3.4% and 7.6%. The results indicate that the developed method can be regarded as suitable for the quantitative determination of polymer additives even at low concentration levels.  相似文献   

12.
We report on the development of a new laser-ionization (LI) source operating at atmospheric pressure (AP) for liquid chromatography/mass spectrometry (LC/MS) applications. APLI is introduced as a powerful addition to existing AP ionization techniques, in particular atmospheric-pressure chemical ionization (APCI), electrospray ionization (ESI), and atmospheric pressure photoionization (APPI). Replacing the one-step VUV approach in APPI with step-wise two-photon ionization strongly enhances the selectivity of the ionization process. Furthermore, the photon flux during an ionization event is drastically increased over that of APPI, leading to very low detection limits. In addition, the APLI mechanism generally operates primarily directly on the analyte. This allows for very efficient ionization even of non-polar compounds such as polycyclic aromatic hydrocarbons (PAHs). The APLI source was characterized with a MicroMass Q-Tof Ultima II analyzer. Both the effluent of an HPLC column containing a number of PAHs (benzo[a]pyrene, fluoranthene, anthracene, fluorene) and samples from direct syringe injection were analyzed with respect to selectivity and sensitivity of the overall system. The liquid phase was vaporized by a conventional APCI inlet (AP probe) with the corona needle removed. Ionization was performed through selective resonance-enhanced multi-photon ionization schemes using a high-repetition-rate fixed-frequency excimer laser operating at 248 nm. Detection limits well within the low-fmol regime are readily obtained for various aromatic hydrocarbons that exhibit long-lived electronic states at the energy level of the first photon. Only molecular ions are generated at the low laser fluxes employed ( approximately 1 MW/cm(2)). The design and performance of the laser-ionization source are presented along with results of the analysis of aromatic hydrocarbons.  相似文献   

13.
An atmospheric pressure photoionization (APPI) source and an atmospheric pressure chemical ionization (APCI) source were compared for the selective detection of microbial respiratory ubiquinone and menaquinone isoprenologues using tandem mass spectrometry. Ionization source- and compound mass-dependent parameters were optimized individually for both sources, using the available quinone standards. Detection levels for the two ion sources were determined with ubiquinone-6 (UQ6) and menaquinone-4 (MK4, vitamin K2) standards using flow injection analysis and selected reaction monitoring (SRM). With APPI the calculated lower limit of detection (LLOD) was 1.7 fmol microl(-1) for UQ6 and 2.2 fmol microl(-1) for MK4 at a signal-to-noise ratio of 3. These LLODs were at least three times lower than with APCI. The selectivity of detection afforded by SRM detection reduced complex mixture analysis to 3 min per sample by eliminating the need for chromatographic separations. The detection method was successfully applied to quinone quantification in a variety of environmental samples and cell cultures. Adequate amounts of respiratory quinones can be extracted and quantified from samples containing as low as 2 x 10(7) cells.  相似文献   

14.
系统地比较了3种常用的离子化技术电喷雾电离(ESI)、大气压化学电离(APCI)、大气压光致电离(APPI)对脂类化合物的离子化效率、检测灵敏度和覆盖范围,以探讨多重离子化液相色谱-质谱(LC-MS)方法在血清脂质组学研究中的适用性.血清样本经甲基叔丁基醚萃取后,采用Ascentiss Express C8 色谱柱(150 mm×2.1 mm, 2.7 μm)和二元线性梯度洗脱分离,流动相(A)为乙腈-水(3∶2, V/V, 含0.1%甲酸, 10 mmol/L甲酸铵),B为异丙醇-乙腈(9∶1, V/V, 含0.1%甲酸,10 mmol/L甲酸铵),分别采用ESI、APCI和APPI离子源正、负离子模式进行质谱检测.结果表明,ESI离子源对脂肪酸类、甘油脂类、甘油磷脂类化合物、鞘磷脂类化合物的离子化效率最高,对异戊烯醇脂类化合物的离子化效率与APPI离子源相当,APPI离子源对胆固醇(酯)类化合物的检测灵敏度最高,APCI离子源对各类化合物的检测灵敏度均低于ESI或APPI离子源;采用ESI和APPI离子源相结合的LC-MS脂质组学分析方法可以提高分析方法的整体灵敏度和血清中脂类信息检测的完整性.  相似文献   

15.
Hydroperoxides formed by autoxidation of common fragrance terpenes are strong allergens and known to cause allergic contact dermatitis (ACD), a common skin disease caused by low molecular weight chemicals. Until now, no suitable methods for chemical analyses of monoterpene hydroperoxides have been available. Their thermolability prohibits the use of gas chromatography and their low UV-absorption properties do not promote sensitive analytical methods by liquid chromatography based on UV detection. In our study, we have investigated different liquid chromatography/mass spectrometry (LC/MS) ionization techniques, electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photoionization (APPI), for detection of hydroperoxides from linalool and limonene.Flow injection analysis was used to evaluate the three different techniques to ionize the monoterpene hydroperoxides, linalool hydroperoxide and limonene hydroperoxide, by estimating the signal efficacy under experimental conditions for positive and negative ionization modes. The intensities for the species [M+H]+ and [M+H-H2O]+ in positive ionization mode and [M-H]- and [M-H-H2O]- in negative ionization mode were monitored. It was demonstrated that the mobile phase composition and instrumental parameters have major influences on the ionization efficiency of these compounds. ESI and APCI were both found to be appropriate as ionization techniques for detection of the two hydroperoxides. However, APPI was less suitable as ionization technique for the investigated hydroperoxides.  相似文献   

16.
Ivano Marchi 《Talanta》2009,78(1):1-610
This review presents the state-of-the-art techniques that couple liquid chromatography (LC) and mass spectrometry (MS) via atmospheric pressure photoionization (APPI). The different ionization mechanisms are discussed as well as the influence of the mobile phase composition, the nature of the dopant, etc. A comparison with other ionization sources, such as electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), is reported, and the combination of APPI with these sources is also discussed. Several applications, covering the time period of 2005-2008, for the analysis of drugs, lipids, natural compounds, pesticides, synthetic organics, petroleum derivatives, and other substances are presented.  相似文献   

17.
This paper describes a comparison between atmospheric pressure chemical ionization (APCI) and the recently introduced atmospheric pressure photoionization (APPI) interface for the LC–MS determination of idoxifene and its major metabolite, SB245419 (SB19), in human plasma. The results indicate that analyte response in APPI is highly dependent on the solvent composition, especially to water in the mobile phase. Other parameters investigated are the mobile phase flow-rate, the chemical noise, and signal suppression by matrix interferences. APPI appears to be six to eight times more sensitive than APCI for idoxifene and its SB245419 metabolite; the response for the SB245420 metabolite is considerably better than for APCI conditions, but still not sufficient for trace level pharmacokinetic determinations in human plasma. The LOQ for the parent drug and its major metabolite were 10 and 25 ng/ml, respectively, in human plasma. From post-column infusion experiments we conclude that there is little difference in matrix suppression between APCI and APPI. From these studies we suggest APPI may be an additional tool in pharmaceutical LC–MS applications.  相似文献   

18.
This study compared the sensitivities and matrix effects of four ionization modes and four reversed-phase liquid chromatographic (LC) systems on analyzing estrone (E1), 17β-estradiol (E2), estriol (E3), 17α-ethinylestradiol (EE2), 4-nonylphenol (NP), 4-tert-octylphenol (OP), bisphenol A (BPA) and their derivatives of dansyl chloride or pentafluorobenzyl bromide (PFBBr) in water matrixes using a triple-quadrupole mass spectrometer with selected reaction monitoring (SRM). The four probes were electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI) and APCI/APPI; the four LC systems were ultra-performance liquid chromatography (UPLC) with or without post-column split, a mixed-mode column and two-dimensional LC (2D-LC). Dansylated compounds with ESI at UPLC condition had the most intense signals and less matrix effects of the various combinations of ionization and LC systems. The on-column limits of detection (LODs) of dansylated estrogens by SRM were 0.05–0.20 pg, and the LODs in sewage treatment plant effluent and in river water were 0.23–0.52 and 0.56–0.91 ng/L, respectively. The LODs using selected ion monitoring (SIM) reached low ng/L levels in real samples and measured concentrations were comparable with those of SRM.  相似文献   

19.
Capillary electrophoresis/mass spectrometry (CE/MS) is predominantly carried out using electrospray ionization (ESI). Recently, atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) have become available for CE/MS. With the VUV lamp turned off, the APPI source may also be used for CE/MS by thermospray ionization (TSI). In the present study the suitability of ESI, APCI, APPI and TSI for drug impurity profiling by CE/MS in the positive ion mode is evaluated. The drugs carbachol, lidocaine and proguanil and their potential impurities were used as test compounds, representing different molecular polarities. A background electrolyte of 100 mM acetic acid (pH 4.5) provided baseline separation of nearly all impurities from the respective drugs. APPI yielded both even‐ and odd‐electron ions, whereas the other ionization techniques produced even‐electron ions only. In‐source fragmentation was more pronounced with APCI and APPI than with ESI and TSI, which was most obvious for proguanil and its impurities. In general, ESI and TSI appeared the most efficient ionization techniques for impurities that are charged in solution achieving detection limits of 100 ng/mL (full‐scan mode). APPI and APCI showed a lower efficiency, but allowed ionization of low and high polarity analytes, although quaternary ammonium compounds (e.g. carbachol) could not be detected. Largely neutral compounds, such as the lidocaine impurity 2,6‐dimethylaniline, could not be detected by TSI, and yielded similar detection limits (500 ng/mL) for ESI, APPI and APCI. In many cases, impurity detection at the 0.1% (w/w) level was possible when 1 mg/mL of parent drug was injected with at least one of the CE/MS systems. Overall, the tested CE/MS systems provide complementary information as illustrated by the detection and identification of an unknown impurity in carbachol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
We report the development and tests of several systems for the simultaneous determination of 18 energetic compounds and related congeners in untreated water samples. In these systems a Restricted Access Material trap or liquid-chromatography precolumn (with a C(18) or porous graphitic carbon, PGC, stationary phase) followed by a PGC analytical column are used for sample clean-up, enrichment and separation of the trace level analytes, which are then analyzed by mass spectrometry (MS). The relative merits of two MS ionization interfaces (atmospheric pressure chemical ionization, APCI, and atmospheric pressure photoionization, APPI) were also compared for the MS identification and quantification of these analytes. APCI was found to be superior in cases where both alternatives are applicable. A major drawback when applying APPI is that no signal is obtained for the cyclic nitramines and nitrate esters. Using APCI, a wide spectrum of unstable compounds can be determined in a single analysis, and the feasibility of using large volume samples (up to 100 mL) in combination with the sensitivity of the MS detection system provide method detection limits ranging from 2.5 pg/mL (for 2,4-dinitrotoluene and 2,6-diamino-6-nitrotoluene) to 563 pg/mL (for pentaerythritol tetranitrate, PETN), with repeatability ranging from 2 to 7%. Other chemometric parameters such as robustness, selectivity, repeatability, and intermediate precision were also evaluated in the validation of the extraction methods for use in water analysis. Tests with untreated groundwater and drinking water samples, spiked with 20 ng of the analytes, yielded results similar to those obtained with high purity water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号