1.
A simple method using a one-step liquid-liquid extraction (LLE) followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of bromazepam in human plasma, using lorazepam as internal standard. The acquisition was performed in the multiple reaction monitoring mode, monitoring the transitions: m/z 316 > 182 for bromazepam and m/z 321 > 275 for lorazepam. The method was linear over the studied range (1-100 ng ml(-1)), with r(2) > 0.98, and the run time was 2.5 min. The intra- and inter-assay precisions were 2.7-14.6 and 4.1-17.3%, respectively and the intra- and inter-assay accuracies were 87-111 and 75.8-109.5%, respectively. The mean recovery was 73.7%, ranging from 64.5 to 79.7%. The limit of quantification was 1 ng ml(-1). At this concentration the mean intra- and inter-assay precisions were 14.6 and 7.1%, respectively, and the mean intra- and inter-assay accuracies were 102.5 and 104%, respectively. Bromazepam stability was evaluated and the results showed that the drug is stable in standard solution and in plasma samples under typical storage and processing conditions. The method was applied to a bioequivalence study in which 27 healthy adult volunteers (14 men) received single oral doses (6 mg) of reference and test bromazepam formulations, in an open, two-period, randomized, crossover protocol. The 90% confidence interval of the individual ratios (test formulation/reference formulation) for C(max) (peak plasma concentration), AUC(0-96) and AUC(0-inf) (area under the plasma concentration versus time curve from time zero to 96 h and to infinity, respectively) were within the range 80-125%, which supports the conclusion that the test formulation is bioequivalent to the reference formulation regarding the rate and extent of bromazepam absorption.  相似文献   

2.
A method based on solid-phase extraction (SPE) coupled to high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed for the simultaneous determination of lamivudine (3TC) and zidovudine (AZT) in human serum, using didanosine (ddI) as internal standard. The acquisition was performed in multiple reaction monitoring (MRM) mode, monitoring the transitions m/z 230.0 --> 111.8 for 3TC, m/z 268.1 --> 126.8 for AZT, and m/z 237.2 --> 136.8 for ddI. The limits of detection and quantitation were 3 and 10 ng/mL for 3TC, and 5 and 15 ng/mL for AZT. The method was linear in the studied ranges (10-1500 ng/mL for 3TC and 15-3000 ng/mL for AZT), with r(2) > 0.99 for each drug, and the run time was 4 min. The intra-assay precisions (%) were in the ranges 1.9-8.7 (3TC) and 2.2-8.9 (AZT), the inter-assay precisions were in the ranges 2.6-9.0 (3TC) and 4.2-8.1 (AZT), and the intra- and inter-assay accuracies were >97% for both drugs. The absolute recoveries were 95-99% for 3TC (45, 600 and 1200 ng/mL) and 104-112% for AZT (45, 1000 and 2400 ng/mL). The analytical method was applied to a bioequivalence study in which 24 healthy adult volunteers received single oral doses of the reference formulation and two test combined AZT/3TC tablets, in an open, three-period, balanced, randomized, crossover protocol. Based on the 90% confidence interval of the individual ratios (test formulation/reference formulation) for C(max) (peak serum concentration) and AUC(0-inf) (extrapolated area under the serum concentration vs. time curve from time zero to infinity), it was concluded that the two test formulations are bioequivalent to the reference formulation with respect to the rate and extent of absorption of both 3TC and AZT.  相似文献   

3.
A method based on solid-phase extraction (SPE) coupled to high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed for the determination of stavudine in human serum, using didanosine as internal standard. The acquisition was performed in multiple reaction monitoring (MRM) mode. The method was linear over the studied range (10-2000 ng/mL), with r(2) > 0.99, and the run time was 4 min. The intra- and inter-assay precisions (%) were in the ranges 0.1-13.6 and 2.6-9.9, respectively, and the intra- and inter-assay accuracies were >92%. The absolute recoveries were approximately 100% (10 ng/mL), 98% (30 ng/mL), 105% (750 ng/mL) and 105% (1500 ng/mL). The limits of detection and quantitation were 4 and 10 ng/mL, respectively. The analytical method was applied to a bioequivalence study, in which 24 healthy adult volunteers (12 men) received single oral doses (40 mg) of reference and two test stavudine formulations, in an open, three-period, randomized, crossover protocol. The 90% confidence interval of the individual ratios (test formulation/reference formulation) for C(max) (peak serum concentration), AUC(0-10) and AUC(0-inf) (areas under the serum concentration vs. time curve from time zero to 10 h and to infinity, respectively), were in the range 80-125%, which supports the conclusion that the two test formulations are bioequivalent to the reference formulation with respect to the rate and extent of stavudine absorption.  相似文献   

4.
Using the avidin-biotin binding system, an enzyme immunoassay procedure was developed to measure the membrane-associated placental tissue protein 1 (MP1) in serum. The standard curve covered the range from 10 to 1000 ng/ml of MP1. The intra- and inter-assay coefficient of variations (C.Vs) were less than 5 and 10%, respectively. Recoveries of MP1 added to serum ranged between about 96 and 101%. The MP1 serum level was over 10 and under 112 ng/ml in non-pathological men, and under 240 ng/ml in non-pathological women. The MP1 level in the ovulatory phase was higher than in other phases of the menstrual cycle. In pregnancies during 6-39 weeks, the MP1 level ranged from 10 to 540 ng/ml, and it increased during the third trimester of gestational age. In benign gynecologic diseases, the MP1 concentration in serum ranged from 10 to 215 ng/ml. The MP1 levels in benign diseases were compared with those in ovarian malignancies, in endometrial carcinoma, and in uterine cervical cancer. The immunohistochemical location of MP1 was detected in the cell membrane of ovarian cystadenocarcinoma.  相似文献   

5.
A rapid, sensitive and specific method to quantify nevirapine in human plasma using dibenzepine as the internal standard (IS) was developed and validated. The method employed a liquid-liquid extraction. The analyte and the IS were chromatographed on a C(18) analytical column, (150 x 4.6 mm i.d. 4 microm) and analyzed by tandem mass spectrometry in the multiple reaction monitoring mode. The method had a chromatographic run time of 5.0 min and a linear calibration curve over the range 10-5000 ng ml(-1) (r(2) > 0.9970). The between-run precision, based on the relative standard deviation for replicate quality controls was 1.3% (30 ng ml(-1)), 2.8% (300 ng ml(-1)) and 3.6% (3000 ng ml(-1)). The between-run accuracy was 4.0, 7.0 and 6.2% for the above-mentioned concentrations, respectively. This method was employed in a bioequivalence study of two nevirapine tablet formulations (Nevirapina from Far-Manguinhos, Brazil, as a test formulation, and Viramune from Boehringer Ingelheim do Brasil Química e Farmacêutica, as a reference formulation) in 25 healthy volunteers of both sexes who received a single 200 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 3 week washout interval. The 90% confidence interval (CI) of the individual ratio geometric mean for Nevirapina/Viramune was 96.4-104.5% for AUC((0-last)), 91.4-105.1% for AUC((0-infinity)) and 95.3-111.6% for C(max) (AUC = area under the curve; C(max) = peak plasma concentration). Since both 90% CI for AUC((0-last)) and AUC((0-infinity)) and C(max) were included in the 80-125% interval proposed by the US Food and Drug Administration, Nevirapina was considered bioequivalent to Viramune according to both the rate and extent of absorption.  相似文献   

6.
A rapid, sensitive and specific analytical method was developed and validated to quantify gabapentin in human plasma using acetaminophen as an internal standard. The method employs a single plasma protein precipitation. The analytes are chromatographed on a C4 reversed-phase chromatographic column and analyzed by mass spectrometry in the multiple reaction monitoring (MRM) mode. The method has a chromatographic run time of 4 min and a linear calibration curve over the range 50-10 000 ng x ml(-1) (r > 0.999). The between-run precision, based on the relative standard deviation for replicate quality controls, was < or = 4.8 % (200 ng x ml(-1)), 6.0% (1000 ng x ml(-1)) and 4.4% (5000 ng x ml(-1)). The between-run accuracy was +/-2.6, 4.4 and 0.5% for the above-mentioned concentrations, respectively. This method was employed in a bioequivalence study of two gabentin capsule formulations (Progresse from Biosintética, Brazil, as a test formulation, and Neurotin from Parke-Davis, as a reference formulation) in 24 healthy volunteers of both sexes who received a single 300 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 7-day washout interval. The 90% confidence interval (CI) of the individual ratio geometric mean for Progresse/Neurotin was 87.9-115.6% for AUC(0-36 h) and 88.6-111.7% for Cmax. Since both 90% CI for AUC(0-36 h) and Cmax were included in the 80-125% interval proposed by the US Food and Drug Administration, Progresse was considered bioequivalent to Neurotin according to both the rate and extent of absorption.  相似文献   

7.
We have developed and validated a simple detection system with high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) for determining cimetropium levels in human plasma using scopolamine butyl bromide as an internal standard (I.S.). The acquisition was performed in the multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 357.9 > 103.1 for cimetropium and m/z 359.9 > 103.1 for butyl-scopolamine. The method involves a simple single-step liquid-liquid extraction with dichloromethane. The analyte was chromatographed on an YMC C18 reversed-phase chromatographic column by isocratic elution with 10 mM ammonium formate buffer-methanol (19:81, v/v; adjusted to pH 4.0 with formic acid). The results were linear over the studied range (0.2-100 ng ml(-1)), with r2 = 1.0000, and the total analysis time for each run was 2 min. Intra- and interassay precisions were 0.70-8.54% and 1.08-4.85%, respectively, and intra- and interassay accuracies were 97.56-108.23% and 97.48-103.91%, respectively. The lower limit of quantification (LLOQ) was 0.2 ng ml(-1). At this concentration, mean intra- and interassay precisions were 8.54% and 4.85%, respectively, and mean intra- and interassay accuracies were 97.56% and 98.91%, respectively. The mean recovery ranged from 62.71 +/- 4.06 to 64.23 +/- 2.32%. Cimetropium was found to be stable in plasma samples under typical storage and processing conditions. The devised assay was successfully applied to a pharmacokinetic study of cimetropium bromide administered as a single oral dose (150 mg) to healthy volunteers.  相似文献   

8.
A liquid chromatographic atmospheric pressure chemical ionization tandem mass spectrometric method is described for the determination of 21-hydroxydeflazacort in human plasma using dexamethasone 21-acetate as an internal standard. The procedure requires a single diethyl ether extraction. After evaporation of the solvent under a nitrogen flow, the analytes are reconstituted in the mobile phase, chromatographed on a C18 reversed-phase column and analyzed by mass spectrometry via a heated nebulizer interface where they are detected by multiple reaction monitoring. The method has a chromatographic run time of less than 5 min and a linear calibration curve with a range of 1-400 ng ml(-1) (r>0.999). The between-run precision, based on the relative standard deviation for replicate quality controls, was < or =5.5% (10 ng ml(-1)), 1.0% (50 ng ml(-1)) and 2.7% (200 ng ml(-1)). The between-run accuracy was +/-7.1, 3.8 and 4.8% for the above concentrations, respectively. This method was employed in a bioequivalence study of two DFZ tablet formulations (Denacen from Marjan Industria e Comercio, Brazil, as a test formulation, and Calcort from Merrell Lepetit, Brazil, as a reference formulation) in 24 healthy volunteers of both sexes who received a single 30 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 7-day washout interval. The 90% confidence interval (CI) of the individual geometric mean ratio for Denacen/Calcort was 89.8-109.5% for area under the curve AUC(0-24 h) and 80.7-98.5% for Cmax. Since both the 90% CI for AUC(0-24 h) and Cmax were included in the 80-125% interval proposed by the US Food and Drug Administration, Denacen was considered bioequivalent to Calcort according to both the rate and extent of absorption.  相似文献   

9.
Mass spectrometry coupled with a pyrolysis inlet system (Pyr-ms) is compared with high performance liquid chromatography (HPLC) for the determination of vancomycin and its crystal degradation products (CDP-Is) in human serum. Quantitative analysis of Pyr-ms was performed by selected ion monitoring (SIM) method at 108 mass:charge (m/z) of pyrolysis product of vancomycin. 3-Nitroaniline (138 m/z) was used as an internal standard. A mu-Bondapak C(18) column and the gradient mobile phase of triethylamine buffer (pH 6.2), acetonitrile and tetrahydrofuran and a photometric detection at 205 nm are found to be the optimum conditions for the HPLC determination of vancomycin and CDP-Is. The limit of detection (LOD=1 ng ml(-1)), linearity (1 ng ml(-1)-10 mg ml(-1)), relative standard deviation (R.S.D.=1%), time analysis (1/2 h) and sample volume (50 mul) of Pyr-ms are far better than of the HPLC method. However, the HPLC method can individually determine the concentration of vancomycin and its degradation products.  相似文献   

10.
A sensitive and specific method for the quantitative determination of paroxetine in human plasma is presented. After solvent extraction from plasma with hexane/ethyl acetate (1 : 1) at alkaline pH and derivatization to the pentafluorobenzyl carbamate derivative, paroxetine was measured by gas chromatography-negative ion chemical ionization mass spectrometry. The carboxylate anion at m/z 372 was obtained at high relative abundance. [2H6]-labeled paroxetine was used as an internal standard and its rapid and facile preparation from the unlabeled compound is described. Calibration graphs were linear within a range of 0.094-12.000 ng x ml(-1) using 1 ml of plasma and 0.469-60 ng x ml(-1) using 200 microl of plasma. Intra-day precision was 1.47% (0.375 ng x ml(-1)), 3.16% (3 ng x ml(-1)) and 1.37% (9 ng x ml(-1)) for the low-level method, and 3.37% (1.875 ng x ml(-1)), 2.72% (15 ng x ml(-1)) and 2.22% (45 ng x ml(-1)) for the high-level method. Inter-day precision was 1.65% (0.375 ng x ml(-1)), 2.13% (3 ng x ml(-1)) and 1.66% (9 ng x ml(-1)) for the low-level method, and 1.10% (1.875 ng x ml(-1)), 1.56% (15 ng x ml(-1)) and 1.90% (45 ng x ml(-1)) for the high-level method. At the limit of quantification (0.094 ng x ml(-1)), intra-day precision was 4.30% (low-level method) and 2.56% (high-level method), and inter-day precision was 3.23% (low-level method) and 3.00% (high-level method). The method is rugged, rapid and robust and has been applied to the batch analysis of paroxetine during pharmacokinetic profiling of the drug.  相似文献   

11.
Ulbrich W  Lamprecht A 《Talanta》2011,84(2):437-442
The bisphosphonates clodronate and alendronate are drugs in the therapy of osteoporosis or Paget's disease. They are highly hydrophilic and therefore of low oral bioavailability. Determination methods for bisphosphonates are often laborious and expensive equipment is needed. The presented quantification method based on kinetic measurement of the fluorescence decrease of an Al3+-morin complex can be used to determine the bisphosphonate content in aqueous and plasma samples. The intra- and inter-assay accuracies were found to be within 98.8% and 102.3% of the target samples for clodronate and within 97.2% and 105.0% of the target samples for alendronate. The LOQ was defined as 15.6 ng/ml for clodronate and 62.5 ng/ml for alendronate. In serum samples, intra- and inter-assay accuracy was found to be within 99.0% and 101.6% of the target samples for clodronate and within 97.8% and 102.6% of the target samples for alendronate. In serum samples, the LOQ was defined as 1.55 mg/ml for clodronate and 0.39 mg/ml for alendronate. Though less sensitive in serum, the presented method could support research on the development of drug delivery systems in vitro and in vivo for the investigated and other structurally related bisphosphonates.  相似文献   

12.
A method based on liquid chromatography with negative ion electrospray ionization and tandem mass spectrometry is described for the determination of nimesulide in human plasma. Liquid-liquid extraction using a mixture of diethyl ether and dichloromethane was employed and celecoxib was used as an internal standard. The chromatographic run time was 4.5 min and the weighted (1/x) calibration curve was linear in the range 10.0-2000 ng x ml(-1). The limit of quantification was 10 ng x ml(-1), the intra-batch precision was 6.3, 2.1 and 2.1% and the intra-batch accuracy was 3.2, 0.3 and 0.1% for 30, 300 and 1200 ng x ml(-1) respectively. The inter-batch precision was 2.3, 2.8 and 2.7% and the accuracy was 3.3, 0.3 and 0.1% for 30, 300 and 1200 ng x ml(-1) respectively. This method was employed in a bioequivalence study of one nimesulide drop formulation (nimesulide 50 mg x ml(-1) drop, Medley S/A Indústria Farmacêutica, Brazil) against one standard nimesulide drop formulation (Nisulid, 50 mg x ml(-1) drop, Astra Médica, Brazil). Twenty-four healthy volunteers (both sexes) took part in the study and received a single oral dose of nimesulide (100 mg, equivalent to 2 ml of either formulation) in an open, randomized, two-period crossover way, with a 2-week washout interval between periods. The 90% confidence interval (CI) for geometric mean ratios between nimesulide and Nisulid were 93.1-109.6% for C(max), 87.7-99.8% for AUC(last) and 88.1-99.7% for AUC(0-infinity). Since the 90% CI for the above-mentioned parameters were included in the 80-125% interval proposed by the US Food and Drug Administration, the two formulations were considered bioequivalent in terms of both rate and extent of absorption.  相似文献   

13.
A sensitive and specific method for the determination of methylphenidate in human plasma is presented. Methylphenidate was extracted from plasma by solvent extraction with hexane at pH 9.3 and derivatized to its heptafluorobutyrate derivative. The derivative was measured by gas chromatography/negative ion chemical ionization mass spectrometry without any further purification. Using this detection mode, a diagnostically useful fragment ion at m/z 369 was obtained at high relative abundance. (18)O(2)-labelled methylphenidate was used as an internal standard and its rapid and facile preparation from the unlabeled compound is described. Calibration graphs were linear within the range 0.14-18.25 ng ml(-1). The inter-assay precision was 8.7% (0.14 ng ml(-1)) and 3.1% (4.56 ng ml(-1)) and the intra-assay variability was 1.3% (0.14 ng ml(-1)) and 0.4% (4.56 ng ml(-1)). Accuracy determinations showed deviations of +0.7% (0.14 ng ml(-1)) and -2.5% (4.56 ng ml(-1)). The method is rugged, rapid and robust and has been applied to the batch analysis of methylphenidate during pharmacokinetic profiling of the drug.  相似文献   

14.
Wu Z  Zhang C  Yang C  Zhang X  Wu E 《The Analyst》2000,125(12):2201-2205
A selective, reliable and rapid method for the simultaneous determination of progesterone and norgestrel concentrations in human serum after taking oral contraceptive tablet has been developed using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) with atmospheric pressure chemical ionization (APCI) interface. The norethisterone was used as the internal standard. Selected transitions of m/z 313/245 for norgestrel, m/z 315/97 for progesterone and m/z 299/109 for norethisterone were monitored using multiple reaction monitoring (MRM) mode for quantitation. The assay was linear over the concentration range of 0.2-50 ng mL-1 for norgestrel and progesterone. The lower level of quantitation in human serum was obtained at 0.2 ng mL-1 for both norgestrel and progesterone using optimum tuning parameters. The intra-assay precision and inter-assay precision do not exceed 10 and 9%, respectively. The method has been applied to the determination of norgestrel and progesterone in serum of female volunteers.  相似文献   

15.
An isocratic high-performance liquid chromatographic (HPLC) method with ultraviolet detection is described for the quantification of the atypical neuroleptic clozapine and its major metabolites, N-desmethylclozapine and clozapine N-oxide, in human serum or plasma. The method included automated solid-phase extraction on C18 reversed-phase material. Clozapine and its metabolites were separated by HPLC on a C18 ODS Hypersil analytical column (5 microns particle size; 250 mm x 4.6 mm I.D.) using an acetonitrile-water (40:60, v/v) eluent buffered with 0.4% (v/v) N,N,N',N'-tetramethylethylenediamine and acetic acid to pH 6.5. Imipramine served as internal standard. After extraction of 1 ml of serum or plasma, as little as 5 ng/ml of clozapine and 10 or 20 ng/ml of the metabolites were detectable. Linearity was found for drug concentrations between 5 and 2000 ng/ml as indicated by correlation coefficients of 0.998 to 0.985. The intra- and inter-assay coefficients of variation ranged between 1 and 20%. Interferences with other psychotropic drugs such as benzodiazepines, antidepressants or neuroleptics were negligible. In all samples, collected from schizophrenic patients who had been treated with daily oral doses of 75-400 mg of clozapine, the drug and its major metabolite, N-desmethylclozapine, could be detected, while the concentrations of clozapine N-oxide were below 20 ng/ml in three of sixteen patients. Using the method described here, data regarding relations between therapeutic or toxic effects and drug blood levels or metabolism may be collected in clinical practice to improve the therapeutic efficacy of clozapine drug treatment.  相似文献   

16.
The histidine-containing dipeptides carnosine (CAR) and structurally related anserine (ANS) and homocarnosine (HCAR), widely distributed in vertebrate organisms, have recently been proposed as endogenous quenchers for highly cytotoxic alpha,beta-unsaturated aldehydes generated by peroxidation. A sensitive, selective, specific and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric assay was developed and validated for the simultaneous determination of these peptides in biological matrices in order to establish their plasma/tissue distribution. Samples (plasma or tissue homogenates from male rats) were prepared by protein precipitation with HClO(4) (1 : 1, v/v) containing H-Tyr-His-OH as internal standard. The supernatant was separated on a Phenomenex Sinergy polar-RP column with a mobile phase of water-acetonitrile-heptafluorobutyric acid (9 : 1 : 0.01, v/v/v) at a flow-rate of 0.2 ml min(-1), with a run time of 10 min. Detection was effected on an ion trap mass spectrometer equipped with an electrospray ionization interface operating in positive ionization mode. The acquisitions were in the multiple reaction monitoring mode using the following precursor --> product ion combinations: H-Tyr-His-OH (internal standard) m/z 319 --> 301; CAR m/z 227 --> 210 + 209; ANS m/z 241 --> 224 + 197 + 170; HCAR m/z 241 --> 156. The method was validated over the concentration range 15-1000 nmol g(-1) and the limit of quantification (LOQ) and limit of detection (LOD) were 12.5 and 4.2 pmol injected, respectively. The intra- and inter-day precisions were <10% (< or =17.47% at the LOQ) and the intra- and inter-assay accuracies were within +/-10% for all concentrations. The mapping profile in rat tissue gave the following results: the highest concentrations of CAR and ANS were found in skeletal muscles (soleus, gastrocnemius, tibialis), followed by the heart, cerebellum and brain (ANS below the LOQ). HCAR was found only in the brain and cerebellum. No histidine-containing dipeptides were detectable in plasma, liver, kidney and lung.  相似文献   

17.
A sensitive and specific assay for detection of busulfan in human plasma was developed. The assay is based on rapid isolation of busulfan by liquid-liquid extraction with ethyl acetate, and detection by high-performance liquid chromatography with electrospray ionization and tandem mass spectrometry. 1,6-Bis(methanesulfonyloxy)hexane, a synthesized analogue of busulfan, was used as the internal standard (IS). The acquisition was performed in the multiple reaction monitoring mode; busulfan and the IS were detected with no interferences from plasma matrix. The method was linear over the range 5-2500 ng mL(-1), with r2 > 0.99 and a run time of only 3.5 min. The intra- and inter-assay precisions were in the ranges 2.1-11.9% and 3.2-10.1%, respectively, and the intra- and inter-assay accuracies were 92.2-107.6% and 94.7-104.1%, respectively. The absolute recoveries were 82.0% (20 ng mL(-1)), 90.6% (1000 ng mL(-1)) and 80.0% (2000 ng mL(-1)) for busulfan, and 89.1% for the IS (1000 ng mL(-1)). The limits of detection and quantification were 2 and 5 ng mL(-1), respectively. The validated method was successfully applied to analyze plasma samples obtained from six adults receiving doses of 1 mg kg(-1) in a conditioning regimen prior to bone marrow transplantation. A marked intra-patient variation in busulfan concentrations during the steady state was observed, which limits the application of pharmacokinetic modeling and suggests that continuous therapeutic monitoring is necessary for adequate individualized dosing. In this regard, the present assay brings important advantages relative to other methods described in the literature, i.e., it is highly specific and simple to perform, with a rapid chromatographic run time (3.5 min), and the whole procedure can be completed in 4-5 h, which would permit dose corrections after the third dose allowing earlier and better dosing adjustments towards the target level of busulfan.  相似文献   

18.
Volpi N 《Electrophoresis》2008,29(17):3504-3510
A new highly specific and sensitive capillary electrophoresis method (electrokinetic chromatography with SDS) for the determination of the total alginic acid (AA) content in pharmaceutical formulations is described by means of capillary electrophoresis at 230 nm after treatment with alginate lyase [4.2.2.3] and separation of unsaturated products, Delta-oligomers (DeltaHexA-[HexA](n)), in particular, DP3 (DeltaHexA-HexA-HexA) and DP4 (DeltaHexA-HexA-HexA-HexA). Using a buffer constituted with 10 mM sodium borate and 50 mM SDS at pH 9.0, micellar electrokinetic capillary chromatography was able to determine with very high resolution the AA Delta-oligomers produced by the action of the lyase (mainly DP3 and DP4) as one single species. The intra- and inter-day variations (CV%) were between 6.3 and 9.1 for migration time and between 2.5 and 5.7 for peak area, respectively. The calibration curve showed good linearity for the examined concentration range (60-360 ng) with an average correlation coefficient greater than 0.980. The lowest detection limit and the lowest quantitation limit of the method were 15 ng (0.25 mg/mL) and 40 ng (0.67 mg/mL), respectively. The intra- and inter-day variations in terms of CV% were 5.5 and 8.6%, respectively, and the intra- and inter-day accuracy was estimated to range from 4.1 to 8.9%, while the percent recoveries of AA were calculated to be 102, 97 and 93% for different AA amounts. Variations in temperatures, voltage and buffer composition in comparison with adopted conditions within a 10% limit do not modify the electrophoresis results. The evaluation of AA was performed in both solid and liquid pharmaceutical formulations also in the presence of other ingredients, in particular, aluminium, sodium and potassium bicarbonate, and emulsifying and flavouring agents. The quantitative results obtained were 101.2+/-3.4% of AA content in tablets and 98.4+/-2.8% in liquid formulation, in total conformity with the label claims.  相似文献   

19.
A high-performance liquid chromatographic method for the measurement of bumetanide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol-water-glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5-2000 ng/ml.  相似文献   

20.
Selective liquid chromatographic assay for propylthiouracil in plasma   总被引:3,自引:0,他引:3  
A liquid chromatographic assay was developed to quantitate propylthiouracil in plasma using an internal standard, 5-propyl-2-thiouracil, of similar structure and physical properties. Caffeine, which coelutes with propylthiouracil, was removed by extraction from serum treated with base. No other compounds were found to interfere in the assay. The drug was extracted from plasma with chloroform with a recovery of 59.4% and the intra- and inter-assay coefficients of variation were 5.7 and 3.3%, respectively. The assay was linear to 3 micrograms/ml with a lower detection limit of 40 ng/ml for a sample volume of 1 ml.  相似文献   