首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
Active Flow Management is a new separation technique whereby the flow of mobile phase and the injection of sample are introduced to the column in a manner that allows migration according to the principles of the infinite diameter column. A segmented flow outlet fitting allows for the separation of solvent or solute that elutes along the central radial section of the column from that of the sample or solvent that elutes along the wall region of the column. Separation efficiency on the analytical scale is increased by 25% with an increase in sensitivity by as much as 52% compared to conventional separations.  相似文献   

2.
Pulsed flow modulation (PFM) is based on higher flow rate time compression of the first GC column effluent, which prior to the injection into the second column is stored for a few seconds in a standard fused silica wide bore transfer line. We constructed the PFM device with two standard 1/16 in. brass compression fittings with the insertion of the two columns inside the wide bore 0.53 mm i.d. fused silica storage transfer line for the elimination of dead volumes. This simple arrangement provides a combination of flexibility in the length of the sample storage transfer line hence comprehensive two-dimensional gas chromatography (GC x GC) cycle time, inert sample path and full elimination of cooling gas consumption. A record short second column injection time of 20 ms is demonstrated. Practical injection times are the sample collection time (such as 4s) divided by the second to first column flow rate ratio (such as 20/0.7), which is typically around 150 ms. Due to the low cost of the device it can also be considered for use with non comprehensive time segmented GC x GC to remove a few accidental coelutions. PFM-GCxGC excels with high second column capacity due to the use of 0.32 mm i.d. columns with high flow rates as the second dimension GC x GC column. As a result, PFM-GCxGC can have up to two orders of magnitude higher second column sample capacity and linear dynamic range for improved reduction of adverse matrix interference effects due to column overloading.  相似文献   

3.
A new type of chromatography column referred to as a parallel segmented flow (PSF) column enables ultra‐high‐speed high‐performance liquid chromatography‐MS to be undertaken. This occurs because the separation efficiency obtained on PSF columns has been shown in prior studies to be superior to conventional columns, and the flow stream is split radially inside the outlet end fitting of the column, rather than in an axial post‐column flow stream split. As a result, the flow through the column can be five times higher than the flow through the MS. In this work, the degradation of amino acids in dilute nitric acid was used to illustrate the process. Separations were obtained in less than 12 s, although the reinjection process was initiated 6 s after the previous injection. The degradation rate constant of tryptophan, in the presence of tyrosine and phenylalanine, was determined. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
杨三东  李乃杰  马周  唐涛  李彤 《色谱》2021,39(10):1065-1076
小型化是液相色谱分离技术发展的重要趋势之一,包括仪器外形尺寸的小型化、分离材料粒径的小型化以及色谱柱内径的小型化。色谱柱内径的减小能够降低样品和流动相的消耗,具有更高的质量灵敏度,特别适合用于复杂样品体系的分离分析。纳升液相色谱一般是指使用内径小于100 μm的毛细管色谱柱,流速范围在每分钟几十至几百纳升的色谱技术。由于流速很低,色谱柱体积很小,柱外效应显著,因此对色谱仪器系统各个模块的性能以及系统柱外效应的优化提出了较高的要求。纳升液相色谱的输液装置需要能够准确稳定地输送纳升级流速,具有梯度输液模式,且拥有一定的耐压能力,以适应不同规格的色谱柱类型;进样装置需要能够进行准确重复的进样过程,进样体积及进样方式适合毛细管色谱柱,同时不产生明显的柱外效应;检测装置需要具有较高的灵敏度,且具有较小的柱外扩散;管路与连接系统需要稳定、可靠、易操作,并能够最大限度地减小柱外体积,适配纳升级流速。鉴于目前大多数纳升液相色谱系统与质谱检测器联用,因而本文主要从输液装置、进样装置、管路与连接3个方面对相关技术领域的研究论文、技术专利以及仪器厂商的宣传文件等进行了检索与归纳,综述了这些模块的技术路线与研究进展,同时简要介绍光学吸收型检测装置的优化思路与研究进展,并对部分商品化的纳升液相色谱系统进行了对比。  相似文献   

5.
A high-throughput liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, which combines on-line sample extraction through turbulent flow chromatography with a monolithic column separation, has been developed for direct injection analysis of drugs and metabolites in human plasma samples. By coupling a monolithic column into the system as the analytical column, the method enables running 'dual-column' extraction and chromatography at higher flow rates, thus significantly reducing the time required for the transfer and mixing of extracted fraction onto the separation column as well as the time for gradient separation. A strategy of assessing and reducing the matrix suppression effect on the on-line extraction LC/MS/MS has also been discussed. Experiments for evaluating the resolution, peak shape, sensitivity, speed, and matrix effect were conducted with dextromethorphan and its metabolite dextrorphan as model compounds in human plasma matrix. It was demonstrated that the total run time for this assay with a baseline separation of two analytes is less than 1.5 min.  相似文献   

6.
Restricted access material (RAM) has been used in the packing of a solid-phase extraction (SPE) column for on-line extractions under turbulent flow conditions. The bio-compatible RAM material works by the principle of size exclusion in addition to conventional reversed-phase chromatography, thereby allowing the extraction and preconcentration of small analyte molecules from biological samples such as plasma. Using small column dimensions (0.76 mm x 50 mm) and a consequently high linear velocity, turbulent flow was achieved during online sample extractions. The improved mass-transfer rate characteristic of turbulent flow allows fast sample cleanup without decreased extraction efficiency. The novel use of the RAM column, connected upstream to a C18 monolithic column, allowed the direct injection, extraction, separation, and MS/MS detection of plasma samples spiked with rofecoxib in a span of 5 min. Calibration curves obtained using this RAM turbulent flow coupled column method showed good linearity (R2 > 0.99) and reproducibility (%RSD < or = 7%). The lower limit of quantitation of rofecoxib in plasma samples was found to be 40 ng/ml. The extraction method showed good recovery of rofecoxib from a plasma matrix with minimal signal loss and robustness after more than 200 plasma injections.  相似文献   

7.
With advances in fast chromatography techniques, and highly sensitive and selective detection methods such as tandem mass spectrometry, very high-throughput bioanalytical methods can now be easily developed. The bottleneck of the analytical process then becomes the sample preparation, which it is now realized is crucial to the robust operation of the analytical system, especially for quantitative assays. Turbulent flow liquid chromatography was developed in the late 1990s, and combines 'size exclusion' and traditional stationary phase column chemistry to separate macromolecules, such as proteins, from smaller molecules and analytes of interest in biological fluids. By definition, the process is very rapid, and the instrumentation and software have been developed for fully automated, on-line extraction of neat biological fluids. This work aims to review the chromatographic theory of turbulent flow chromatography and illustrate, using examples from recent literature, the application of this technique to a range of analytes from a number of different biological matrices.  相似文献   

8.
The conventional reverse fill/flush flow modulation for comprehensive two-dimensional gas chromatography requires a bleed capillary column to be connected to the outlet of the modulator channel. The purpose of this capillary, which does not contain the stationary phase, is to provide pressure resistance to the modulator channel flow. In this way, the desired modulator volumetric flow can be achieved, and channel over-filling can be avoided. Normally, the length and the internal diameter of the bleed capillary are chosen so as to obtain the modulator flow that is close to the flow of the first separation column. Thus, for any chosen set of chromatographic conditions, the required dimensions of the bleed capillary can be completely different, making the two-dimensional gas chromatography method development tedious and generating additional costs in consumables and analyst time. In this work, a tuneable pressure source generating a suitable backpressure was used instead of the fixed bleed capillary which has the advantage of the possibility to freely adapt the pressure resistance and generate the required modulator channel flow for any conditions. This set-up has been evaluated and compared in terms of the impact on the modulation performance to the set-up involving a fixed bleed capillary demonstrating comparable performance.  相似文献   

9.
K. Hibi  A. Wada  S. Mori 《Chromatographia》1986,21(11):635-641
Summary Several polystyrene gels of different pore sizes were packed into a 500 mm×2.1 mm I.D. column. Semi-micro size-exclusion chromatography (SEC) using these columns was carried out with a system consisting of a triple piston pump, a micro loop injector and a flow cell with 1.0-μl cell volume constructed for semi-micro HPLC, because the dead volume of the injector and the cell volume of flow cell for conventional HPLC caused a significant loss in column efficiency. The effects of sample amount, injection volume and mobile phase flow rate on column efficiency and retention volume were examined and the optimized operational variables of the sample amount (below 500 μg), the injection volume (less than 15 μl) and the flow rate range (30–70 μl/min) determiend for semi-micro SEC. Oligostyrene, epoxy resin, phenol-formaldehyde resin and phthalates were analyzed by the optimized semi-micro SEC system under the given conditions. In addition, molecular weight distribution of four different poly(ethylene terephthalate) films was successfully measured by using a mixture of chloroform and hexafluoroisopropanol as the eluent.  相似文献   

10.
A cold on-column injection system for capillary gas chromatography (GC) applications was constructed. It was based upon a conventional split/splitless capillary GC inlet, which in turn was a modification of a conventional packed GC column inlet. The heart of the laboratory constructed cold on-column inlet design was a disposable pyrex micro-sampling pipet, which functioned as a needle guide for sample injection. The sample was injected through a traditional GC septum. Construction of the injection system is described and applications are illustrated by separations of a variety of complex mixtures.  相似文献   

11.
Preliminary results are presented on the development of a sensitive, quantitative immunoassay based on a regenerable, flow injection analysis system incorporating a double-amplification approach. The double amplification is achieved by means of liposome-encapsulated peroxidase enzyme molecules which are released subsequent to a competitive immunological reaction with analyte molecules for immobilized antibodies. The released peroxidase enzymatically cleaves, from an organofluorine substrate, fluoride ions which are then potentiometrically measured. The entire process is carried out in a flow injection analysis system. The competition between the analyte molecules (theophylline) and theophylline-derivatized liposomes for immobilized antibody sites in flow-through immunoreactor column results in unbound liposomes being carried downstream where they are ruptured in the presence of hydrogen peroxide andp-fluorophenol. The peroxidase molecules released react enzymatically to produce fluoride ions which are measured with an ion-selective electrode. The immunoreactor column is then regenerated with a chaotropic agent and the next sample or calibration solution is injected. By means of column regeneration and calibration, accurate quantitation can be achieved; a feature missing from conventional batch-type immunoassays. By means of this liposome/enzyme double-amplification approach, theophylline was determined over a range of concentrations from 0.2 to 4000 ng/ml. The detection limit of 200 pg/ml corresponds to about 100 femtomole of theophylline measured in the 100 l sample injected.Dedicated to Professor W. Simon on the occasion of his 60th birthday  相似文献   

12.
The need for faster and more efficient separations of complex mixtures of organic compounds by gas chromatography has led to the development of small inner diameter open tubular columns. Owing to their decreased plate height, extremely narrow peaks are obtained. When differently sized columns with equal plate numbers are compared, injection of a fixed amount of a solute will give the highest detector signals for the smallest bore columns. When P is defined as the ratio of the column inlet and outlet pressures, it can be seen from theory that under normalized chromatographic conditions the minimum detectable amount (Qº) for a mass flow sensitive detector increases proportionally to the square of the column diameter for P = 1. In the situation of greater interest in the practice of open tubular gas chromatography where P is large, a linear relationship is derived between Qº and the column diameter. It is a widespread misunderstanding, however, that narrow bore capillary columns should be used for this reason in trace analysis. If a fixed relative contribution of the injection band width to the overall peak variance is allowed, a decreased plate height drastically restricts the maximum sample volume to be injected. It is shown that the minimum analyte concentration in the injected sample (Cº) is inversely proportional to the column inner diameter when a mass flow sensitive detector is used. For actual concentrations less than Cº, sample preconcentration is required. The effect of peak resolution and selectivity of the stationary phase in relation to Cº and Qº will be discussed as well. The validity of the given theory is experimentally investigated. Minimum analyte concentrations and minimum detectable amounts are compared using columns with different inner diameter.  相似文献   

13.
Summary In the case of liquid chromatography columns packed with small (3–5 m) particles and utilized at relatively high flow rates, pressure pulses associated with the sample injection process (caused by a short-duration interruption in mobile phase flow to the column during injection) may result in a reduction of column lifetime. This detrimental effect can be eliminated by the utilization of specially constructed sample injection valves incorporating properly desinged bypass loops. The paper investigates in detail the effect of pressure pulses, describes the criteria and performance of the bypass systems, and documents column life time and performance.Dedicated to Dr. L. S. Ettre on the occasion of his sixtieth birghday.  相似文献   

14.
The contributions to the radial distribution of the sample concentration across the column inlet and to the axial band dispersion resulting from a column header containing a distributor were evaluated using a band-visualization process entailing matching the refractive indices of the stationary and mobile phases in a glass column. This study illustrates graphically how a distributor fitted to the column can increase the axial dispersion of the sample band compared to an inlet containing only a frit. The distributor did not provide a uniform sample distribution across the column. In fact, for 17-mm inner diameter columns and high-porosity frits, the distribution was no better than with the frit having no distributor. However, when low-porosity frits were employed, improved peak shapes were obtained with a distributor. In addition, we observed that the inlet header configuration influenced dramatically the flow stream established along the column. The radial distribution of the efficiency of the columns was nearly homogeneous for those having only a frit but not for those having also a distributor. For the latter, the efficiency decreased from the column axis to its wall.  相似文献   

15.
The coupling of stripping voltammetry with flow injection systems offers significant advantages over conventional stripping methods. Equations solved for conventional stripping voltammetry, with steady-state deposition current, are not applicable to flow injection systems. Theoretical equations for the peak current under flow injection conditions are derived. As the total charge passed during the deposition step, ∫i dt, is independent of the shape of the sample plug, the stripping peak current is independent of the degree of dispersion. As a result, precise control of the dispersion or deposition period may not be required. The peak current is predicted to be directly proportional to the sample volume. Experimental results are incorporated to support the theoretical conclusions. The effects of experimental variables such as flow rate, length of tubing, deposition period, or sample volume are presented using cadmium ion as test species.  相似文献   

16.
A simple, fast and sensitive liquid chromatography-mass spectrometry (LC-MS) method with automated on-line extraction using turbulent flow chromatography (TFC) for the determination of five catechins in human plasma was developed. In this method, after on-line extraction by its injection onto an extractor column at turbulent flow, five catechins were backwashed onto a reversed phase column via on-line column switching and separated chromatographically at a laminar flow of 1 ml min(-1). Using this tandem LC-LC-MS system, the extraction, the separation and the quantitation of five catechins in human plasma could be achieved with satisfactory selectivity and sensitivity. The limit of detection (S/N = 3) ranged from 0.6 to 2 ng ml(-1). The described procedure was very simple and rapid since no off-line sample preparation was required, total analysis time being 18.5 min.  相似文献   

17.
The use of turbulent flow chromatography in conjunction with column switching isocratic focusing was used to perform on-line sample cleanup and concentration of neat rat plasma for the identification of low-level metabolites. The concentration was achieved by focusing multiple injections, which were cleaned by a turbulent flow column, onto an analytical column prior to elution into the mass spectrometer. In addition, the first application of turbulent flow chromatography for on-line sample cleanup of neat bile samples is reported. The on-line cleanup and concentration method extracts and concentrates a sample 20-fold in 1 h, and is completely automated.  相似文献   

18.
An experimental injection port has been designed for split or splitless sample introduction in capillary gas chromatography; the inlet uses electronic pressure control, in order that the column head pressure may be set from the GC keyboard, and the inlet may be used in the constant flow or constant pressure modes. Alternatively, the column head pressure may be programmed up or down during a GC run in a manner analogous to even temperature programming. Using electronic pressure control, a method was developed which used high column head pressures (high column flow rates) at the time of injection, followed by rapid reduction of the pressure to that required for optimum GC separation. In this way, high flow rates could be used at the time of splitless injection to reduce sample discrimination, while lower flow rates could be used for the separation. Using this method, up to 5 μl of a test sample could be injected in the splitless mode with no discrimination; in another experiment, 2.3 times as much sample was introduced into the column by using electronic pressure programming. Some GC peak broadening was observed in the first experiment.  相似文献   

19.
Hsieh Y  Brisson JM  Ng K  White RE  Korfmacher WA 《The Analyst》2001,126(12):2139-2143
A polymer-coated mixed-function (PCMF) column was evaluated for direct plasma injection for the simultaneous determination of a drug candidate and its hydroxyl metabolite by high-performance liquid chromatography (HPLC) with tandem mass spectrometry (MS-MS) in support of pharmacokinetic studies. Each diluted monkey plasma sample containing internal standard was directly injected on to the PCMF column for sample clean-up, enrichment and chromatographic separation. The proteins and macromolecules were first eluted from the column while the drug molecules were retained on the bonded hydrophobic phase. The analytes retained on the column were then eluted with a strong mobile phase using a gradient separation technique at a constant flow rate of 1.0 ml min(-1). When not diverted, the column effluent was connected either to the atmospheric pressure chemical ionization (APCI) source or the electrospray ionization (ESI) source as part of the mass spectrometer system used for quantification. The calibration curve was linear over the range 5-2500 ng ml(-1) for both analytes. The retention times for the analytes and the internal standard were both consistent and no column deterioration was observed for at least 500 injections. The recovery through the column and reproducibility of the dosed compound and its hydroxyl metabolite in monkey plasma samples were > 90% (RSD < 6%). The total analysis time was < 8 min per sample. The analytical results obtained by the proposed direct plasma injection method were in good agreement with those obtained by the conventional LC-MS-MS method.  相似文献   

20.
A simple, fast and sensitive liquid chromatography/atmospheric pressure photoionization mass spectrometry (LC/APPI-MS) method, with automated on-line extraction using turbulent flow chromatography (TFC), was developed for the determination of perfluorooctane sulfonate (PFOS) in river water. In this method, following an on-line extraction by injection onto a column under TFC conditions, PFOS is back-flushed onto a reversed-phase column via on-line column switching, and resolved chromatographically at a laminar flow rate of 1 mL min(-1). Using this tandem LC-LC/APPI-MS system the extraction, separation and selective detection of PFOS in river water could be achieved with satisfactory selectivity and sensitivity. The limit of detection (LOD) (S/N = 3) and the limit of quantitation (LOQ) (S/N = 10)were 5.35 and 17.86 pg mL(-1). The described procedure was very simple since no off-line sample preparation was required, total analysis time being 18.75 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号