首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 562 毫秒
1.
Pan X  Tian K  Jones LE  Cobb GP 《Talanta》2006,70(2):455-459
A simple, sensitive LC-ESI-MS method was optimized for quantitative analysis of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) in environmental samples. Under negative ionization mode, HMX can form adduct ions with various organic acids and salts, including acetic acid, formic acid, propionic acid, ammonium nitrate, ammonium chloride, sodium nitrite, and sodium nitrate. Acetic acid was chosen as additive and the ion, [M + CH3COO] with m/z = 355 was used for selective ion monitoring (SIM) in this study. Good sensitivity was achieved with low acetic acid concentration in the mobile phase and relatively low capillary temperature. The method detection limit was 0.78 pg for HMX in standard solution. Linearity (R2 > 0.9998) was obtained at low concentrations (0.5-50 μg/L). This method has been used to determine HMX concentrations in water samples and lizard egg samples from an animal exposure study.  相似文献   

2.
In the present study, dissociative electron attachment (DEA) measurements with gas phase HMX, octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine, C4H8N8O8, have been performed by means of a crossed electron-molecular beam experiment. The most intense signals are observed at 46 and 176 u and assigned to NO2 ? and C3H6N5O4 ?, respectively. Anion efficiency curves for 15 negatively charged fragments have been measured in the electron energy region from about 0–20 eV with an energy resolution of ~0.7 eV. Product anions are observed mainly in the low energy region, near 0 eV, arising from surprisingly complex reactions associated with multiple bond cleavages and structural and electronic rearrangement. The remarkable instability of HMX towards electron attachment with virtually zero kinetic energy reflects the highly explosive nature of this compound. Substantially different intensity ratios of resonances for common fragment anions allow distinguishing the nitroamines HMX and royal demolition explosive molecule (RDX) in negative ion mass spectrometry based on free electron capture.   相似文献   

3.
We apply differential scanning calorimetry (DSC) to measure the kinetics of the βδ solid-solid phase transition of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine, HMX. Integration of the DSC signal gives a direct measurement of degree of conversion. Data is analyzed by first-order kinetics, the Ozawa method, and isoconversional analysis. The range of activation energies found in this work, centering around 500 kJ/mol, is much higher than previously reported values by Brill and co-workers [AIAA J. (1982)], 204 kJ/mol [1], and Henson et al. and Henson and co-workers [B. Henson, L. Smilowitz, B. Asay, P. Dickson, Thermodynamics of the beta to delta phase transition in PBX-9501, in: Proceedings of American Physical Society Topical Group on Shock Compression of Condensed Matter, American Institute of Physics, Atlanta, GA, 2001; L. Smilowitz, B. Henson, J. Robinson, P. Dickson, B. Asay, Kinetics of the beta to delta phase transition in PBX-9501, in: Proceedings of American Physical Society Topical Group on Shock Compression of Condensed Matter, American Institute of Physics, Atlanta, GA, 2001; P.M. Dickson, B.W. Asay, B.F. Henson, C.S. Fugard, J. Wong, Measurement of phase change and thermal decomposition kinetics during cookoff of PBX-9501, in: Proceedings of American Physical Society Topical Group on Shock Compression of Condensed Matter, American Institute of Physics, Snowbird, UT, 1999], 200 kJ/mol [4]. We discuss possible reasons for the higher activation energies measured here but do not identify the cause.  相似文献   

4.
A quantitative liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method was developed for the analysis of the explosive, octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX). In negative ionization mode, HMX forms an acetate adduct ion [M + CH(3)COO](-), m/z 355, in the presence of a small amount of acetic acid in the mobile phase. The ESI collision-induced dissociation (CID) spectrum of m/z 355 was acquired and the transitions m/z 355 --> 147 and m/z 355 --> 174 were chosen for the determination of HMX in samples. Using this quantification technique, the method detection limit was 1.57 microg/L and good linearity was achieved in the range 5-500 microg/L. This method will help to unambiguously analyze environmentally relevant concentrations of HMX.  相似文献   

5.
A BODIPY-based fluorescent derivatization reagent with a hydrazine moiety, 1,3,5,7-tetramethyl-8-aminozide-difluoroboradiaza-s-indacene (BODIPY-aminozide), has been designed for aldehyde labeling. An increased fluorescence quantum yield was observed from 0.38 to 0.94 in acetonitrile when it reacted with aldehydes. Twelve aliphatic aldehydes from formaldehyde to lauraldehyde were used to evaluate the analytical potential of this reagent by high performance liquid chromatography (HPLC) on C18 column with fluorescence detection. The derivatization reaction of BODIPY-aminozide with aldehydes proceeded at 60 °C for 30 min to form stable corresponding BODIPY hydrazone derivatives in the presence of phosphoric acid as a catalyst. The maximum excitation (495 nm) and emission (505 nm) wavelengths were almost the same for all the aldehyde derivatives. A baseline separation of all the 12 aliphatic aldehydes (except formaldehyde and acetaldehyde) is achieved in 20 min with acetonitrile–tetrahydrofuran (THF)–water as mobile phase. The detection limits were obtained in the range from 0.43 to 0.69 nM (signal-to-noise = 3), which are better than or comparable with those obtained by the existing methods based on aldehyde labeling. This reagent has been applied to the precolumn derivatization followed with HPLC determination of trace aliphatic aldehydes in human serum samples without complex pretreatment or enrichment method.  相似文献   

6.
This work reports the development of a selective, sensitive and rapid spectrofluorimetric method for the determination of reduced glutathione (GSH) in the presence of relatively high levels of cysteine (Cys) in clinical and biological samples using 1,3,5,7-tetramethyl-8-phenyl-(2-maleimide)-difluoroboradiaza-s-indacene (TMPAB-o-M). The fluorescence from TMPAB-o-M is strongly quenched by its maleimide moiety, but after reaction with thiol, the fluorescence is restored with a 350-fold intensity increase (fluorescence quantum yield from 0.002 to 0.73). In H3Cit-Na2HPO4 buffer (pH 7.40), the derivatization is completed in just 5 min under 37 °C. The linear range is 0.005-0.2 μmol L−1, with detection limit of 1.1 × 10−10 mol L−1 (signal-to-noise ratio = 3). Almost all amino acids, including Cys, impose no interference even if present at relatively high concentrations (amino acids:GSH = 100:1, Cys:GSH = 1:1, molar ratio, CGSH = 3 × 10−7 mol L−1). The sample can be used directly without further treatment after the protein is removed. The developed method is precise with a relative standard deviation (R.S.D.) lower than 5.0% (n = 6) and has been applied to the determination of GSH in human blood and pig’s liver with recoveries between 94.4 and 105.6%.  相似文献   

7.
Pan X  Zhang B  Cobb GP 《Talanta》2005,67(4):816-823
An efficient extraction and cleanup technique, and an instrumental detection method suitable for determination of trace amounts of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and its nitroso-metabolites in animal liver tissue were developed and validated in this paper. The method includes the extraction of explosives from liver tissue samples using accelerated solvent extraction (ASE) followed by cleanup using florisil and styrene-divinyl benzene (SDB) cartridges to remove interfering naturally endogenous compounds. The instrumental analysis was conducted using a capillary column gas chromatograph coupled with an electron capture detector (GC-ECD). High recoveries (58.9-106.8%) of RDX, hexahydro-1-nitroso-3,5-dinitro-1,3,5-triazine (MNX), hexahydro-1,3-dinitroso-5-nitro-1,3,5-triazine (DNX), and hexahydro-1,3,5-trinitroso-1,3,5-triazine (TNX) were achieved at all concentrations studied. RDX, MNX, and TNX gave higher recoveries than DNX at all three tested concentrations (50, 250, 1250 ng/g). Overall recoveries of RDX, MNX, DNX, and TNX from 1 g beef liver samples containing 50, 250, and 1250 ng/g were 80.1, 82.8, 68.9, and 80.4%, respectively. The optimal injection port temperature range was 160-170 °C for analysis of RDX and its nitroso-metabolites. Higher or lower temperatures than 160-170 °C decreased signal amplitudes. RDX was unstable in the liver extraction matrix; as much as 50% of RDX was degraded 10 days after extraction if keeping the liver sample extracts at room temperature. Degradation of RDX to MNX, DNX, or TNX was not detected during the sample storage, extraction, or instrument analysis processes. Other optimized extraction and GC conditions are also discussed.  相似文献   

8.
Yan H  Row KH 《Analytica chimica acta》2007,584(1):160-165
A sensitive, simple, and accurate method for determination of levofloxacin and its (R)-enantiomer was developed to determine the chiral impurity of levofloxacin in Cravit Tablets material by ligand-exchange high performance liquid chromatography. The effects of different kinds of ligands, concentration of ligands in mobile phase, organic modifier, pH of mobile phase, and temperature on enantioseparation were investigated and evaluated. Chiral separation was performed on a conventional C18 column, where the mobile phase consisted of a methanol-water solution (containing10 mmol L−1l-leucine and 5 mmol L−1 copper sulfate) (88:12, v/v) and its flow-rate was set at 1.0 mL min−1. The conventional C18 column offers baseline separation of two enantiomers with a resolution of 2.4 in less than 20 min. Thermodynamic data (ΔΔH and ΔΔS) obtained by Van’t Hoff plots revealed the chiral separation is an enthalpy-controlled process. The standard curves showed excellent linearity over the concentration range from 0.5 to 400 mg L−1 for levofloxacin and its (R)-enantiomer. The linear correlation equations are: y = 1.33 × 105x + 6297 (r = 0.9991) and y = 1.34 × 105x + 3565 (r = 0.9997), respectively. The relative standard deviation (RSD) of the method was below 2.3% (n = 3).  相似文献   

9.
The pyrolysis products formed during the isothermal decomposition of HMX at 211°C are H2O, HCN, CO, CH2O, NO, N2O, methylformamide, C2H6N2O, octahydro-1-nitroso-3,5,7-trinitro-1,3,5,7-tetrazocine, and a nonvolatile residue. The temporal behaviors of these products during the decomposition are presented. The method for using time-of-flight (TOF) velocity spectra to assist mass-spectrometry measurements in identifying the different gaseous products formed from the pyrolysis of a material by determining the approximate molecular weights of the different gaseous products contributing to the different m/z values in the mass spectrum of the mixture is described. The ion fragmentation of HMX as a function of electron energy shows complete fragmentation of the HMX molecular ion for electron energies ≥ 12.4 eV. No fragments from the pyrolysis of HMX other than those mentioned above are observed.  相似文献   

10.
A method for the determination of isocyanates as di-n-butyl amine (DBA) derivatives using tandem mass spectrometry (MS/MS) and electrospray ionisation (ESI) is presented. Multiple-reaction monitoring (MRM) of the protonated molecular ions and corresponding deuterium-labelled d9-DBA derivatives resulted in selective quantifications with correlation coefficients >0.998 for the DBA derivatives of isocyanic acid (ICA), methyl isocyanate (MIC), ethyl isocyanate (EIC), propyl isocyanate (PIC), phenyl isocyanate (PhI), 1,6-hexamethylene diisocyanate (HDI), 2,4-, 2,6-toluene diisocyanate (TDI), isophorone diisocyanate (IPDI), 4,4′-methylenediphenyl diisocyanate (MDI), 3-ring MDI, 4-ring MDI, HDI-isocyanurate, HDI-diisocyanurate, HDI-biuret and HDI-dibiuret. The instrumental precision for 10 repeated injections of a solution containing 0.1 μg ml−1 of the studied derivatives was <2%. Performing MRM of the product ion [DBA + H]+ (m/z = 130) from the protonated molecular ion resulted in the lowest detection limits, down to 10 amol (for TDI). Quantification of concentrations below 10−6 of the occupational exposure limit (OEL) for TDI during 10 min of air sampling was made possible. In an effort to control the formation of alkali adducts, addition of lithium acetate to the mobile phase and monitoring of lithium adducts was evaluated. Having lithium present in the mobile phase resulted in complete domination of [M + Li]+ adducts, but detection limits for the studied compounds were not improved. Different deuterium-labelled derivatives as internal standards were evaluated. (1) DBA derivatives of deuterium-labelled isocyanates (d4-HDI, d3-2,4-TDI, d3-2,6-TDI and d2-MDI), (2) d9-DBA derivatives of the corresponding isocyanates and (3) d18-DBA derivatives of the corresponding isocyanates. An increase in number of deuterium in the molecule of the internal standard resulted in an increase in instrumental precision and a decrease in correlation within calibration series.  相似文献   

11.
A high-performance liquid chromatographic method has been developed for the determination in human plasma of the specific serotonin reuptake inhibitor (SSRI) antidepressant paroxetine and its three main metabolites (M1, M2, M3). Fluorescence detection was used, exciting at λ = 294 nm and monitoring emission at λ = 330 nm for paroxetine (λexc = 280 nm, λem = 330 nm for M1 and M2; λexc = 268 nm, λem = 290 nm for M3). Separation was obtained on a reversed-phase C18 column using a mobile phase composed of 66.7% aqueous phosphate at pH 2.5 and 33.3% acetonitrile. Imipramine (λexc = 252 nm, λem = 390 nm) was used as the internal standard. A careful pre-treatment of plasma samples was developed, using solid-phase extraction with C8 cartridges (50 mg, 1 mL). The calibration curves were linear over a working range of 2.5-100 ng mL−1 for paroxetine and of 5-100 ng mL−1 for all metabolites. The limit of detection (LOD) was 1.2 ng mL−1 for PRX and 2.0 ng mL−1 for the metabolites. The method was applied with success to plasma samples from depressed patients undergoing treatment with paroxetine. Hence, the method seems to be suitable for the therapeutic drug monitoring of paroxetine and its main metabolites in depressed patients’ plasma.  相似文献   

12.
A quantitative liquid chromatographic-electrospray ionization mass spectrometric method for the determination of dexamethasone in sheep plasma has been developed and validated. The samples were extracted using solid-phase extraction cartridges with mixed reversed-phase materials (oasis-HLB). The chromatographic separation was performed on a reversed-phase XTerrra MS C18 column ( mm; 5 μm) using a mobile phase consisting of 65% methanol in water containing 0.1% (v/v) formic acid, pumped at a flow rate of 0.30 ml min−1. The analyte was detected after positive electrospray ionization using selected ion monitoring (SIM) mode. The probe heater temperature was set at 260 °C, the capillary voltage was set at 3.5 kV and the source block voltage (AQAmax) was set at 30 V. The method was fully validated. Calibration graphs were linear (r better than 0.998, n=11), in concentration ranges 6-1000 ng ml−1 for dexamethasone. The intra- and inter-day RSD values were less than 24.1% (n=6). The limits of detection and quantitation for dexamethasone were found to be 1 and 6 ng ml−1, respectively. The efficiency of the solid phase extraction procedure was found to be 92.4% for dexamethasone. The method was further applied to a pilot kinetic study in order to assess the main pharmacokinetic parameters of dexamethasone in sheep.  相似文献   

13.
A rapid and specific liquid chromatographic-mass spectrometric method has been developed and validated for the determination of the carboxylic acid metabolite of clopidogrel in human plasma. Sulphafurazole was used as internal standard. The samples were subjected to a solid phase extraction procedure using Hypercarb cartridges. The chromatographic separation was performed on a reversed phase porous graphitized carbon column using a mobile phase consisting of 70% methanol in water containing 0.1% (v/v) trifluoroacetic acid, pumped at a flow rate of 0.25 ml min−1. The analytes were detected after positive electrospray ionization using the selected ion monitoring mode of the species at m/z 308 for the carboxylic acid metabolite of clopidogrel, m/z 322 for clopidogrel and m/z 268 for sulphafurazole. Calibration graphs were linear (r>0.9994, n=6), in the range 100-1000 ng ml−1 for the carboxylic acid metabolite of clopidogrel. The intra- and inter-day R.S.D. values were <3.1%, while the relative error Er was less than −9.6% (n=6). The limits of detection (3.3σ) and quantitation (10σ) for the carboxylic acid metabolite of clopidogrel were found to be 28 and 93 ng ml−1, respectively. The efficiency of the solid phase extraction procedure for the carboxylic acid metabolite of clopidogrel averaged 74.6%.  相似文献   

14.
Olivier Vigneau 《Talanta》2009,77(5):1609-1058
The introduction of chloroform into the nebulising gas of a LC/MS electrospray interface (ESI), in a perfectly controlled way, leads to the formation of intense adducts ([M+Cl]) when a mobile phase containing HMX (1,3,5,7-tetranitro-1,3,5,7-tetrazacyclooctane or octogen) and RDX (1,3,5-trintro-1,3,5-triazacyclohexane or hexogen) is eluted. This LC/MS method allows the direct analysis of aqueous samples containing HMX and RDX at the pictogram level without a concentration step. The method is used to determine HMX and RDX concentrations in ground water samples from a military site.  相似文献   

15.
A simple chiral high-performance liquid chromatography (HPLC) method with ultraviolet (UV) and circular dichroism (CD) detection was developed and validated for measuring benalaxyl enantiomers using (R,R) Whelk-O 1 column. The effects of mobile phase composition and column temperature on the entioseparation were investigated. A CD detector was used to determine the elution order of the enantiomers. Excellent resolution was easily obtained using n-hexane-polar organic alcohols mobile phase. The chiral recognition mechanism was also discussed. Based on the developed chiral HPLC method, enantioselective analysis methods for this fungicide in environment matrix (soil and water) were developed and validated. Good linearities were obtained over the concentration range of 0.25-25 mg L−1 for both enantiomers. Liquid-liquid extraction and solid phase extraction (SPE) were used for the enrichment and cleanup of soil and water samples. Recoveries for the two enantiomers were 79-91% at 0.02, 0.04 and 0.2 mg kg−1 levels from soil, and 89-101% at 0.0025, 0.01 and 0.05 mg L−1 levels from water. Run-to-run and day-to-day assay precisions were below 10% for both enantiomers at concentrations of 0.5, 1 and 5 mg L−1. Individual detection limits of the two enantiomers were both 2 ng. Limits of detection (LOD) were 0.004 mg kg−1 in soil and 0.001 mg L−1 in water.  相似文献   

16.
A method for enhanced extraction of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) from environmental samples is developed with the assistance of sodium dodecyl sulphate (SDS) surfactant. In this study, the concentration of SDS surfactant and other analytical parameters are optimized on a high-performance liquid chromatography-UV system. An isocratic flow of 1.0 mL/min with mobile phase acetonitrile-water; 70:30 (v/v) at 230 nm wavelength on a reverse-phase amide column is used for baseline separation of explosives and making calibration curves. The amount of recovered explosives from spiked soil and water samples are calculated. The limits of detection obtained for HMX and RDX standards are 1.5 and 3.8 ppb (S/N=3), respectively, which are much better than obtained by the Environmental Protection Agency method 8330. The recoveries are found to be enhanced by 1.7 and 1.6-fold with SDS solution as compared to water for HMX and RDX, respectively, from soil samples.  相似文献   

17.
A simple and sensitive method has been developed using preconcentration technique solid phase microextraction (SPME) and analytical technique HPLC-UV for the determination of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) from the environmental samples. Aqueous solution of anionic surfactant SDS was used for the extraction of both nitramine high explosives, viz., HMX and RDX from soil samples which were subsequently sorbed on SPME fiber. The static desorption was carried out in the desorption chamber of the SPME-HPLC interface in the presence of mobile phase ACN/methanol/water (30:35:35) and the subsequent chromatographic analysis at a flow rate of 0.5 mL/min and detection at 230 nm. For this purpose, a C(18), 5 microm RP analytical column was used as a separation medium in this method. Several parameters relating to SPME, e.g., adsorption/desorption time, concentration of salt, stirring rate, etc., were optimized. The method was linear over the range of 20-400 ng/mL for HMX and RDX standards in the presence of surfactant in aqueous phase, respectively. The correlation coefficient (R(2)) for HMX and RDX are 0.9998 and 0.9982, respectively. With SPME, the detection limits (S/N = 3) in ng/mL are 0.05 and 0.1 for HMX and RDX, respectively in the presence of the SDS surfactant. The developed method has been applied successfully to the analysis of real environmental samples like bore well water, river water, and ground alluvial soil.  相似文献   

18.
A simple, precise, and accurate hydrophilic interaction liquid chromatographic (HILIC) method has been developed for the determination of five aromatic amines in environmental water samples. Chromatography was carried out on a bare silica column, using a mixture of acetonitrile and a buffer of NaH2PO4–H3PO4 (pH 1.5, containing 10 mM NaH2PO4) (85:15, v/v) as a mobile phase at a flow rate of 1 mL min−1. Aromatic amines were detected by UV absorbance at 254 nm. The linear range of amines was good (r2 > 0.998) and limit of detection (LOD) within 0.02–0.2 mg L−1 (S/N = 3). The retention mechanism for the analytes under the optimum conditions was determined to be a combination of adsorption, partition and ionic interactions. The proposed method was applied to the environmental water samples. Aromatic amines were isolated from aqueous samples using solid-phase extraction (SPE) with Oasis HLB cartridges. Recoveries of greater than 75% with precision (RSD) less than 12% were obtained at amine concentrations of 5–50 μg L−1 from 100 mL river water and influents from a wastewater treatment plant (WWTP). The present HILIC technique proved to be a viable method for the analysis of aromatic amines in the environmental water samples.  相似文献   

19.
An analytical method based on the cloud point extraction combined with high performance liquid chromatography is used for the extraction, separation and determination of four explosives; octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazine (HMX), hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), 2,4,6-trinitrotoluene (TNT) and pentaerythritol tetranitrate (PETN). These compounds are extracted by using of Triton X-114 and cetyl-trimethyl ammonium bromide (CTAB). After extraction, the samples were analyzed using a HPLC-UV system. The parameters affecting extraction efficiency (such as Triton X-114 and CTAB concentrations, amount of Na2SO4, temperature, incubation and centrifuge times) were evaluated and optimized. Under the optimum conditions, the preconcentration factor was 40 and the improvement factors of 34, 29, 61 and 42 with detection limits of 0.09, 0.14, 0.08 and 0.40 (μg L−1) were obtained for HMX, RDX, TNT and PETN, respectively. The proposed method was successfully applied to the determination of these compounds in water samples and showed recovery percentages of 97-102% with RSD values of 2.13-4.92%.  相似文献   

20.
Huang KJ  Wang H  Guo YH  Fan RL  Zhang HS 《Talanta》2006,69(1):73-78
A new fluorescent probe 1,3,5,7-tetramethyl-2,6-dicarbethoxy-8-(3′,4′-diaminophenyl)-difluoroboradiaza-s-indacene (TMDCDABODIPY) has been developed to detect nitrite in meat products and vegetables. The fluorescence of TMDCDABODIPY is very weak, but when it reacts with nitrite, a strong fluorescent triazole forms in aqueous medium at room temperature, which offers the advantage of specificity and sensitivity for the determination of nitrite. The fluorescence intensity was linear over a nitrite concentration of 9-300 nmol l−1 with a detection limit of 0.21 nmol l−1 (S/N = 3). The proposed method has been used for the determination of trace nitrite in food products with the recoveries of 94.62-105.48%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号