首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
The present work describes the development of a sensitive and reliable analytical method based on solid‐phase extraction followed by analysis using liquid chromatography with tandem mass spectrometry for the simultaneous determination of pharmaceuticals from antibiotics (fluoroquinolones, sulfonamides, and their N4‐acetyl metabolites, and trimethoprim as sulfonamides synergist) and anthelmintics groups. SPE was optimized using different cartridges (Strata‐X, Oasis HLB, Strata C18‐E, Isolute C18, SampliQ C8/Si‐SCX). The highest recovery was achieved using Strata X cartridge (>80%) with good reproducibility (RSDs < 5%) despite various physicochemical properties of the compounds. Investigated analytes were identified and quantitatively determined by liquid chromatography with tandem mass spectrometry using multiple reaction monitoring. The method was shown to be linear over the concentration range of 0.05–30 μg/L for febantel and albendazole, and 0.10–60 μg/L for all other pharmaceuticals. Correlation coefficients were >0.99 for all compounds except for sulfamethazine (0.98). In order to demonstrate the applicability of the developed method, wastewater from the veterinary industry was analyzed. Results evidenced the presence of febantel, praziquantel, albendazole, enrofloxacin, sulfamethazine, and sulfadiazine.  相似文献   

2.
This paper focuses on the investigation of different types of SPE sorbents for the preconcentration of eight veterinary pharmaceuticals from water samples. The pharmaceuticals studied were sulfamethazine, sulfadiazine, sulfaguanidine, trimethoprim, oxytetracycline, enrofloxacin, norfloxacin and penicillin G/procaine. Five different SPE materials (Strata‐X, Strata‐X‐C, Strata SDB‐L, Strata C8 and Strata C18) from Phenomenex were compared with Oasis HLB with a view to obtaining the best cartridges for all pharmaceuticals investigated. Extraction efficiency was determined by HPLC with diode array detection (DAD). HPLC‐DAD separation and quantification of the selected pharmaceuticals were carried out under gradient elution by a binary mixture of 0.01 M oxalic acid and ACN based on cyano modified column (LiChrosphere 100 CN) from Merck. Strata‐X provided the best results in the preconcentration of 100 mL water samples, yielding average pharmaceutical recoveries of higher than 90%, except for sulfaguanidine (76.1%). The developed Strata‐X‐HLPC‐DAD method was validated and applied, for the efficient investigation of reverse osmosis/nanofiltration membranes and for the removal of these eight pharmaceuticals from the production wastewater samples. NF90 and XLE membranes were shown to be the best for the rejection of all investigated pharmaceuticals.  相似文献   

3.
《Analytical letters》2012,45(9):1682-1690
Abstract

The recovery of the pharmaceuticals bezafibrate and tetracycline from water was evaluated, using Solid Phase Extraction (SPE) with the aim of applying this technique to interrupt the pharmaceuticals' photodegradation by photo-Fenton process for further analysis. Sep-Pack C-18, Strata X, and Oasis HLB cartridges were evaluated. Oasis HLB showed the most satisfactory recovery and repeatability results: 98% (CV = 1%) for bezafibrate (20.0 mg L?1) and 76% (CV = 1%) for tetracycline (25.0 mg L?1). There was not a significant decrease in recovery at lower concentrations of the pharmaceuticals, and neither when present in Sewage Treatment Plant (STP) effluent matrix.  相似文献   

4.
The objective of this paper is to provide information about application of solid-phase extraction (SPE) for isolation of nine high-intensity sweeteners (acesulfame-K, alitame, aspartame, cyclamate, dulcin, neotame, saccharin, sucralose and neohesperidin dihydrochalcone) from aqueous solutions. The influence of several types of LC-MS compatible buffers (different pH values and compositions) on their recovery has been studied and discussed. A number of commercially available SPE cartridges, such as Chromabond C18ec, Strata-X RP, Bakerbond Octadecyl, Bakerbond SDB-1, Bakerbond SPE Phenyl, Oasis HLB, LiChrolut RP-18, Supelclean LC-18, Discovery DSC-18 and Zorbax C18 were tested in order to evaluate their applicability for the isolation of analytes. Very high recoveries (better than 92%) of all studied compounds were obtained using formic acid-N,N-diisopropylethylamine buffer adjusted to pH 4.5 and C18-bonded silica sorbents. Behaviour of polymeric sorbents strongly depends on their structure. Strata-X RP behaves much like a C18-bonded silica sorbent. Recoveries obtained using Oasis HLB were comparable with those observed for silica-based sorbents. The only compound less efficiently (83%) retained by this sorbent was cyclamate. Bakerbond SDB-1 shows unusual selectivity towards aspartame and alitame. Recoveries of these two sweeteners were very low (26 and 42%, respectively). It was also found that aspartame and alitame can be selectively separated from the mixture of sweeteners using formic acid-triethylamine buffer at pH 3.5.  相似文献   

5.
In the present study, a simple procedure for the isolation by solid-phase extraction (SPE) and quantification by UV-Vis spectrometry (400 nm) of the humic acids (HAs) in the natural waters was developed. Seven different sorbents: Porapak P (polystyrene-divinylbenzene copolymer), Florisil (chemical composition: 84.0% SiO2, 15.5% MgO and 0.5% Na2SO4), Silica gel C18 (octadecyl silane), Strata X (surface modified polystyrene-divinylbenzene), Strata NH2 (silica-based trifunctional amino ligand), Strata SAX (silica-based trifunctional quaternary amine) and Strata C18-E (silica-based trifunctional C18 with hydrophobic end-capping of silanols) were tested. The HAs, adsorbed on SPE cartridges, were eluted using: NaOH (0.1 M), sodium dodecyl sulphate (SDS) (20 g L−1), and a 1:1 v/v mixture of SDS (20 g L−1) and NaOH (0.1 M). The extraction efficiency was evaluated by comparing the HAs recovery levels. The repeatability of results was estimated by the relative standard deviation (RSD). The data confirmed that Porapak P, Silica gel C18, Florisil, Strata NH2 and Strata X could be good alternatives for the traditional isolation of the aquatic HAs with XAD resin. The proposed method was applied for the determination of HAs in some waters sampled from the Western Romanian Plain. The content of HAs was correlated with the arsenic concentration and total organic carbon (TOC) level.   相似文献   

6.
Fuh MR  Wu TY  Lin TY 《Talanta》2006,68(3):987-991
A method using a solid phase extraction (SPE) and ion-pair liquid chromatography-electrospray-tandem mass spectrometry (LC-ES-MS/MS) was developed for determination of amphetamine (Amp) and methamphetamine (mAmp) in urine samples. A reversed phase C18 column was utilized for LC separation and MS/MS was used for detection. Trifluoroacetic acid was added to the mobile phase as an ion-pairing reagent. MS2 was employed for quantitative determination. In addition, d8-amphetamine and d8-methamphetamine were used as internal standards. An Oasis HLB SPE cartridge, which has hydrophilic and lipophilic functions, was utilized for sample pre-treatment. Recoveries ranging from 97.3 to 102.1% were measured. Good linear ranges, 5-500 ng/ml, for Amp and mAmp were determined. The detection limit of each analytical compound, based on a signal-to-noise ratio of 3, was approximately 1 ng/ml. The applicability of this newly developed method was examined by analyzing several urine samples from drug users.  相似文献   

7.
A simple solid-phase extraction (SPE) procedure with an octadecyl bonded phase silica (C18) was developed for clean-up of the fungicide thiram from aqueous solutions containing high concentrations of humic substances, for future studies of thiram adsorption onto solid humic substances or soils. Suspensions of humic acids and soil, in aqueous 0.01 M CaCl2 solution, were prepared and used as samples. These extracts were spiked with thiram and immediately applied to a C18-SPE cartridge. Thiram was eluted with chloroform and its concentration measured by spectrophotometry at 283 nm. Non-spiked aqueous extracts (blanks) and a control sample of thiram in 0.01 M CaCl2 aqueous solution were also prepared and submitted to the same SPE procedure. The results show that humic substances are extensively retained by the C18 cartridge but are not eluted with CHCl3. Recoveries of 100-104% were obtained for thiram in the presence of humic substances. The SPE procedure described in this work is an efficient clean-up step to remove the interference of humic substances absorbance and to be coupled to any spectrophotometric or HPLC-UV method, usually used for thiram analysis in food extracts.  相似文献   

8.
A novel and simple method has been developed for the simultaneous determination of beta-lactam antibiotics (BLAs) (penicillin G, amoxicillin, ampicillin, penicillin V, oxacillin, cloxacillin, dicloxacillin and nafcillin) in wastewater. The method is based on solid-phase extraction (SPE) and high performance liquid chromatography with UV-diode array detection (UV-DAD). Two SPE cartridges have been compared for sample clean up and preconcentration: a reversed-phase silica-based cartridge (Bond Elut C18, Varian Inc.) and a strong polymeric mixed mode anion exchanger (Oasis MAX, Waters). The penicillins have been separated using a LUNA™ C18 (2) (150 mm × 4.6 mm, 5 μm) HPLC column and gradient elution with mobile phases consisting of aqueous trifluoroacetic acid and acetonitrile. The analytical wavelength was set at 220 nm. Under optimised conditions it was possible to preconcentrate up to 1000 mL of Milli-Q water in the Oasis MAX cartridges with recoveries in the range 82-97% (R.S.D. 2-9%) for all the antibiotic tested, except amoxicillin (52%, R.S.D. 8%), and limits of detection in the range of 8-24 ng L−1. The matrix components in industrial and urban wastewater samples reduce the preconcentration efficiency in both sorbents, especially for the Bond Elut C18. The use of the Oasis MAX allowed detection limits between 2.9-25.6, 2.5-12.4 and 2.2-12.7 μg L−1, when processing 250 mL of industrial, influent and effluent sewage treatment plant (STP) samples. Recoveries ranged between 46-91, 28-91 and 39-114% (industrial, influent and effluent STP, respectively) for samples spiked with all the antibiotics at 25 and 75 μg L−1 (n = 3 for each level).  相似文献   

9.
A simple adsorption/desorption procedure using a mixed matrix membrane (MMM) as extraction medium is demonstrated as a new miniaturized sample pretreatment and preconcentration technique. Reversed-phase particles namely polymeric bonded octadecyl (C18) was incorporated through dispersion in a cellulose triacetate (CTA) polymer matrix to form a C18-MMM. Non-steroidal anti-inflammatory drugs (NSAIDs) namely diclofenac, mefenamic acid and ibuprofen present in the environmental water samples were selected as targeted model analytes. The extraction setup is simple by dipping a small piece of C18-MMM (7 mm × 7 mm) in a stirred 10 mL sample solution for analyte adsorption process. The entrapped analyte within the membrane was then desorbed into 100 μL of methanol by ultrasonication prior to high performance liquid chromatography (HPLC) analysis. Each membrane was discarded after single use to avoid any analyte carry-over effect. Several important parameters, such as effect of sample pH, salting-out effect, sample volume, extraction time, desorption solvent and desorption time were comprehensively optimized. The C18-MMM demonstrated high affinity for NSAIDs spiked in tap and river water with relative recoveries ranging from 92 to 100% and good reproducibility with relative standard deviations between 1.1 and 5.5% (n = 9). The overall results obtained were found comparable against conventional solid phase extraction (SPE) using cartridge packed with identical C18 adsorbent.  相似文献   

10.
A method using an on-line solid phase extraction (SPE) and liquid chromatography with electrospray-tandem mass spectrometry (LC-ES-MS/MS) for the determination of flunitrazepam (FM2) and 7-aminoflunitrazepam (7-aminoFM2) in urine was developed. A mixed mode Oasis HLB SPE cartridge column was utilized for on-line extraction. A reversed phase C18 LC column was employed for LC separation and MS/MS was used for detection. Sample extraction, clean-up and elution were performed automatically and controlled by a six-port valve. Recoveries ranging from 94.8 to 101.3% were measured. For both 7-aminoFM2 and FM2, dual linear ranges were determined from 20 to 200 and 200-2000 ng/ml, respectively. The detection limit for each analyte based on a signal-to-noise ratio of 3 ranged from 1 to 3 ng/ml. The intra-day and inter-day precision showed coefficients of variance (CV) ranging from 4.6 to 8.5 and 2.6-9.2%, respectively. The applicability of this newly developed method was examined by analyzing several urine samples.  相似文献   

11.
This paper describes the development of an optimized method based on solid-phase extraction (SPE) followed by liquid chromatography–electrospray ionization tandem mass spectrometry (LC–MS/MS) for the simultaneous analysis of ten antibiotic compounds including tetracyclines, sulfonamides, macrolides and quinolones. LC–MS/MS sensitivity has been optimized by alterations to both LC and MS operations. Of the two high resolution columns tested, Waters Symmetry C18 endcapped and Agilent Zorbax Bonus-RP, the latter was found to show better performance in producing sharp peaks and clear separation for most of the target compounds. Optimization of the MS fragmentation collision and cone energy enhanced the peak areas of the target analytes. The recovery of the target compounds from water samples was most efficient on Waters Oasis HLB SPE cartridge, while methanol was shown to be the most suitable solvent for desorbing the compounds from SPE. In addition, acidification of samples prior to SPE was shown to enhance the recovery of the compounds. To ensure a satisfactory recovery, the flow rate through SPE should be maintained at ≤10 mL min−1. The method was successfully applied to the analysis of antibiotics from environmental water samples, with concentrations being <LOD in tap water, between <LOD to 28 ng L−1 in river water and between <LOD to 230 ng L−1 in sewage effluent.  相似文献   

12.
This paper discusses the development of a comprehensive method for the simultaneous analysis of personal care products (PCPs) based on SPE and GC‐MS. The method was developed on 29 target compounds to represent PCPs belonging to different chemical classes: surfactants in detergents (alkyl benzenes), fragrances in cosmetics (nitro and polycyclic musks), antioxidants and preservatives (phenols), plasticizers (phthalates) displaying a wide range of volatility, polarity, water solubility. In addition to the conventional C18 stationary phase, a surface modified styrene divinylbenzene polymeric phase (StrataTM X SPE cartridge) has been investigated as suitable for the simultaneous extraction of several PCPs with polar and non‐polar characteristics. For both sorbents different solvent compositions and eluting conditions were tested and compared in order to achieve high extraction efficiency for as many sample components as possible. Comparison of the behavior of the two cartridges reveals that, overall, Strata‐X provides better efficiency with extraction recovery higher than 70% for most of the PCPs investigated. The best results were obtained under the following operative conditions: an evaporation temperature of 40°C, elution on Strata‐X cartridge using a volume of 15 mL of ethyl acetate (EA) as solvent and operating with slow flow rate (–10 KPa). In addition to the conventional method based on peak integration, a chemometric approach based on the computation of the experimental autocovariance function (EACVFtot) was applied to the complex GC‐MS signal: the percentage recovery and information on peak abundance distribution can be evaluated for each procedure step. The PC‐based signal processing proved very helpful in assisting the development of the analytical procedure, since it saves labor and time and increases result reliability in handling GC complex signals.  相似文献   

13.
Rodenticides are used as pest control to eradicate rodents and have emerged as new environmental contaminants due to their widespread use in domestic and urban infrastructures. In this study, we have developed and validated an analytical methodology based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the determination of 13 anticoagulant rodenticides in wastewater. In a first step, ionization conditions were tested in electrospray mode, and positive ionization gave the highest sensitivity. Fragmentation patterns were determined and two selected reaction monitoring (SRM) transitions were selected for each compound. Using a Zorbax Eclipse XDB-C18 column and specific SRM transitions, 13 compounds were resolved. The LC-MS/MS method provided good linearity, sensitivity, intra- and inter-day precision, and good identification capabilities for these compounds in wastewaters. Thereafter miniaturized liquid–liquid extraction (LLE) and solid-phase extraction (SPE) were optimized. Oasis HLB and Strata WA SPE cartridges with methanol/dichloromethane as eluting solvents provided good recoveries and limits of detection ranged between 0.34 and 20 ng L?1, whereas LLE failed to recover some compounds. Finally, the performance of both LLE and SPE methods was evaluated by analyzing rodenticides in a set of wastewaters. Warfarin was the only detected compound at nanogram per liter level, and good agreement was observed between LLE and SPE.  相似文献   

14.
In this work, a simple, sensitive and affordable analytical method for the simultaneous determination of nine organotin compounds (butyltins, phenyltins and methyltins) in seawater using solid-phase extraction (SPE) and gas chromatography-pulsed flame photometric detection was developed and validated. The performance of three different SPE cartridges (Envi C18, Oasis HLB and Oasis MCX) and three elution solvents of different polarity (hexane, methanol and acetonitrile) was evaluated. The extraction parameters, such as solvent volume, presence of complexing and ion-pairing reagents, sample volume and pH and breakthrough volume, were also investigated. Tributyltin, as the organotin compound of special interest, was efficiently extracted using any of the cartridges and solvents tested. However, the simultaneous extraction of all nine organotin compounds was the most efficient using reversed-phase Envi C18 cartridge and 0.1% (w/v) tropolone in methanol as eluent. The optimised method resulted in good recovery, precision and linearity for all compounds, particularly for tri- and disubstituted species. Method detection limits ranged from 0.22 to 1.27 ng(Sn) L?1 for butyltins, 0.37 to 4.91 ng(Sn) L?1 for phenyltins and 0.45 to 1.16 ng(Sn) L?1 for methyltins. The accuracy of butyltins determination was further verified by the comparison with purchased derivatised standards. The developed method was successfully applied to the environmental samples.  相似文献   

15.
Ochratoxin A (OTA) is a mycotoxin produced by some species of Aspergillus and Penicillium verrucosum. It has been found in foods and feed all over the world. There is a great concern about OTA because it is nephrotoxic and probably, carcinogenic to humans. Most of analytical methods developed for OTA in wine, beer and other products are based on LC with fluorescence detection (LC-FLD). In the present work, various procedures for extraction and/or clean-up for determination of OTA in musts, wine and beer by LC-FLD were compared: (1) dilution with polyethylen glycol 8000 and NaHCO3 solution and clean-up an on immunoaffinity column (IAC); (2) extraction with chloroform and IAC clean-up; solid-phase extraction (SPE) on (3) reversed-phase (RP) C18; (4) RP phenylsilane and (5) Oasis HLB cartridges. SPE on phenylsilane and Oasis HLB have not been reported for OTA analysis in beverages. The same LC-FLD conditions and concentration ratio were used. The former procedure was simple, rapid and provided flat baselines, free from most impurity peaks, high OTA recoveries and quite repeatable results. RP C18 using methanol-acetic acid (99.5:0.5) as elution solvent provided good recoveries and precision, thus becoming a cheaper but interesting alternative at 0.1-1 ng/ml spiking levels. Oasis HLB cartridges were usually better than phenylsilane. Possible binding of OTA to proteins or other components was tested by acid treatment before extraction but no significant differences with controls appeared.  相似文献   

16.
Summary A reversed-phase high performance liquid chromatographic (HPLC) method with an acetonitrile-methanol-water mobile phase gradient and photodiode-array detection (DAD) is described for simultaneous determination of 21 pesticides, frequently used in agriculture, of different types, namely organophosphorus, organochlorine,N-methylcarbamates, triazines and phenylureas in vegetable samples. The pesticides were extracted with acetone and then partitioned from the vegetable sample with dichloromethane. Sample clean-up was accomplished by solid-phase extraction (SPE) using both C18 and florisil SPE columns. Average recoveries from green beans ranged from 70.0 to 110.1%. Detection limits of less than 0.1 mg kg–1 were obtained.  相似文献   

17.
A sensitive and reliable method based on MEKC has been developed and validated for trace determination of neonicotinoid insecticides (thiamethoxam, acetamiprid, and imidacloprid) and the metabolite 6‐chloronicotinic acid in water and soil matrices. Optimum separation of the neonicotinoid insecticides was obtained on a 58 cm long capillary (75 μm id) using as the running electrolyte 40 mM SDS, 5 mM borate (pH 10.4), and 5% (v/v) methanol at a temperature of 25°C, a voltage of 25 kV and with hydrodynamic injection (10 s). The analysis time was less than 7 min. Prior to MEKC determination, the samples were purified and enriched by carrying out extraction‐preconcentration steps. For aqueous samples, off‐line SPE with a sorptive material such as Strata‐X (polymeric hydrophobic sorbent) and octadecylsilane (C18) was carried out to clean up and preconcentrate the insecticides. However, for soil samples, matrix solid‐phase dispersion (MSPD) was applied with C18 used as the dispersant. Good linearity, accuracy, and precision were obtained and the detection limits were in the range between 0.01 and 0.07 μg mL?1 for river water and 0.17 and 0.37 μg g?1 for soil samples. Recovery levels reached greater than 92% for all of the assayed neonicotinoids in river water samples with Strata‐X. In soil matrices, the best recoveries (63–99%) were obtained with MSPD.  相似文献   

18.
This study investigates an off-line solid phase extraction (SPE) for improving the sensitivity in the capillary electrophoretic (CE) analysis of four cephalosporins. Two sorbents—LiChrolut-C18 and Oasis HLB—were used in a SPE process to detect cephalosporins in natural waters (tap, river and hospital sewage) and their performances were compared. By using Oasis HLB sorbent higher recoveries for river water were obtained (94–107% when 500 mL of sample were analyzed). The off-line SPE–CZE method was validated for river water with good detection limits (3 μg L−1) and the linearity ranged between 5 and 200 μg L−1.  相似文献   

19.
The monitoring of organochlorine pesticides has raised a great concern in the last years due to their toxicity (some of them are carcinogenic and endocrine disruptor compounds) and persistence. European Directive 2008/105/EC establishes very restrictive levels for organochlorine pesticides in surface waters. Therefore, simple, fast, highly sensitive and low cost analytical methods are required to detect and quantify these pollutants in water. In the present work, four procedures for extraction and determination are proposed and compared for the analysis of 28 organochlorine pesticides in tap, surface and sea waters. The suitability of each method of analysis was evaluated for each kind of water. The extraction methods proposed were: two solid-phase extraction methods using C18 laminar disk and Oasis HLB cartridges, a solid-phase microextraction procedure using a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre, and a micro liquid–liquid extraction procedure using ethyl acetate as solvent. Determination of pesticides was performed by large volume on-column injector-gas chromatography-electron capture detection (LVOCI-GC-ECD), splitless-GC-ECD and GC-MS (mass spectrometry). All methods present a good sensitivity with method detection limits lower than 10?ng?L?1, good accuracy with recoveries between 75 and 120% (with some exceptions) and good precision (relative standard deviations <15%), according to the Commission Decision 2002/657/EC criteria. The advantages and disadvantages of each method are discussed in terms of the green chemistry principles, the figures of merit and the matrix effect. This work tries to be a useful guidance for routine and control analysis laboratories.  相似文献   

20.
This study describes an efficient method using on-line solid-phase extraction (SPE) (Oasis HLB) for preparative HPLC purification of short-lived radiotracers for positron emission tomography (PET) and for HPLC analysis of radiotracers and their metabolites in cell homogenates, plasma and urine samples. The radiochemical purity of tracers (fluorine-18 labeled) purified using this method (Oasis column) was >99% compared to 90% when no Oasis column was used. Radiometabolites of several fluorine-18 and carbon-11-labeled tracers and one technetium-99m tracer were quantified in cell homogenates, plasma and urine samples. Samples were analyzed using Oasis column and analytical HPLC system without prior precipitation of proteins or removal of other biological matrices. The metabolites observed for the evaluated tracers were all polar relative to the unchanged tracer. The extraction repeatability was found to be good (RSD 2.2%) and recoveries of Oasis column/HPLC-injected radioactivity (plasma) were found to be high (mean recovery >91%). The same Oasis column was used for several times without back pressure build-up or decrease of the HPLC separation characteristics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号