首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
A new liquid chromatographic (LC) method for simultaneous determination of lidocaine hydrochloride (LH) and tribenoside (TR) along with their related compounds in pharmaceutical preparations is described. Satisfactory LC separation of all analytes after the liquid–liquid extraction (LLE) procedure with ethanol was performed on a C18 column using a gradient elution of a mixture of acetonitrile and 0.1 % orthophosphoric acid as the mobile phase. The procedure was validated according to the ICH guidelines. The limits of detection (LOD) and quantification (LOQ) were 4.36 and 13.21 μg mL?1 for LH, 7.60 and 23.04 μg mL?1 for TR, and below 0.11 and 0.33 μg mL?1 for their impurities, respectively. Intra- and inter-day precision was below 1.97 %, whereas accuracy for all analytes ranged from 98.17 to 101.94 %. The proposed method was sensitive, robust, and specific allowing reliable simultaneous quantification of all mentioned compounds. Moreover, a comparative study of the RP-LC column classification based on the quantitative structure-retention relationships (QSRR) and column selectivity obtained in real pharmaceutical analysis was innovatively applied using factor analysis (FA). In the column performance test, the analysis of LH and TR in the presence of their impurities was carried out according to the developed method with the use of 12 RP-LC stationary phases previously tested under the QSRR conditions. The obtained results confirmed that the classes of the stationary phases selected in accordance with the QSRR models provided comparable separation for LH, TR, and their impurities. Hence, it was concluded that the proposed QSRR approach could be considered a supportive tool in the selection of the suitable column for the pharmaceutical analysis.  相似文献   

5.
Summary Separation of positional and cis-trans-isomers of tetrahydro-1,5-benzothiazepines and tetrahydro-1,5-benzodiazepines was studied using reversed-phase chromatography and liquid-solid chromatography. The selection of solvent was based on the selective triangle for solvents. Systems of separation consisted of C18 columns and methanol, THF or acetonitrile in water for the reversedphase method; it was suitable for the separation of positional isomers only but the liquid-solid method was suitable for separation of cis-trans-isomers as well as positional isomers using a silica column and ethyl ether, chloroform or ethyl acetate as the mobile phase respectively.  相似文献   

6.
There are various reversed‐phase stationary phases that offer significant differences in selectivity and retention. To investigate different reversed‐phase stationary phases (aqueous stable C18, biphenyl, pentafluorophenyl propyl, and polar‐embedded alkyl) in an automated fashion, commercial software and associated hardware for mobile phase and column selection were used in conjunction with liquid chromatography and a triple quadrupole mass spectrometer detector. A model analyte mixture was prepared using a combination of standards from varying classes of analytes (including drugs, drugs of abuse, amino acids, nicotine, and nicotine‐like compounds). Chromatographic results revealed diverse variations in selectivity and peak shape. Differences in the elution order of analytes on the polar‐embedded alkyl phase for several analytes showed distinct selectivity differences compared to the aqueous C18 phase. The electron‐rich pentafluorophenyl propyl phase showed unique selectivity toward protonated amines. The biphenyl phase provided further changes in selectivity relative to C18 with a methanolic phase, but it behaved very similarly to a C18 when an acetonitrile‐based mobile phase was evaluated. This study shows the value of rapid column screening as an alternative to excessive mobile phase variation to obtain suitable chromatographic settings for analyte separation.  相似文献   

7.
Saponins are widely distributed in the plant kingdom and have been shown to be active components of many medicinal herbs. In this study, a two-dimensional purification method based on reversed-phase liquid chromatography coupled with hydrophilic interaction liquid chromatography was successfully applied to purify saponins from leaves of Panax notoginseng. Nine saponin reference standards were used to test the separation modes and columns. The standards could not be resolved using C18 columns owing to their limited polar selectivity. However, they were completely separated on a XAmide column in hydrophilic interaction liquid chromatography mode, including two pairs of standards that were coeluted on a C18 column. The elution order of the standards on the two columns was sufficiently different, with a correlation coefficient between retention times on the C18 and XAmide columns of 0.0126, indicating good column orthogonality. Therefore, the first-dimension preparation was performed on a C18 column, followed by a XAmide column that was used to separate the fractions in the second dimension. Fifty-four fractions were prepared in the first dimension, with 25 fractions rich in saponins. Eight saponins, including two pairs of isomeric saponins and one new saponin, were isolated and identified from three representative fractions. This procedure was shown to be an effective approach for the preparative isolation and purification of saponins from leaves of P. notoginseng. Moreover, this method could possibly be employed in the purification of low-content and novel active saponins from natural products.
Figure
Separation of saponins using 2-D RPLC/HILIC  相似文献   

8.
The selection of column packing during the development of high-performance liquid chromatography method is a crucial step to achieve sufficient chromatographic resolution of analyzed species in complex mixtures. Various stationary phases are tested in this paper for the analysis of complex mixture of triacylglycerols (TGs) in blackcurrant oil using non-aqueous reversed-phase (NARP) system with acetonitrile–2-propanol mobile phase. Conventional C18 column in the total length of 45 cm is used for the separation of TGs according to their equivalent carbon number, the number and positions of double bonds and acyl chain lengths. The separation of TGs and their more polar hydrolysis products after the partial enzymatic hydrolysis of blackcurrant oil in one chromatographic run is achieved using conventional C18 column. Retention times of TGs are reduced almost 10 times without the loss of the chromatographic resolution using ultra high-performance liquid chromatography with 1.7 μm C18 particles. The separation in NARP system on C30 column shows an unusual phenomenon, because the retention order of TGs changes depending on the column temperature, which is reported for the first time. The commercial monolithic column modified with C18 is used for the fast analysis of TGs to increase the sample throughput but at cost of low resolution.  相似文献   

9.
Summary The chromatographic behaviour of some porphyrins and their complexes with zinc has been studied by HPLC on 150×3.9 mm and 300×3.9 mm columns packed with Nova-Pak C18 and μ-Bondapak C18, respectively, and on a microcolumn (64×2 mm) packed with Nucleosil C18. The effect of the nature and the arrangement of side substituents in the porphyrin molecules on retention is considered. It is demonstrated that HPLC can be used for the separation ofcis-andtrans-isomers (atropisomers) of the zinc complex of 5,15-di(phenyl-2-CH3O)-3,7,13,17-tetramethyl-2,8,12,18-tetrabutylporphyrin and other porphyrins with a similar structure. The efficiency of separation has been compared on different columns.  相似文献   

10.
Summary On-column endcapping and derivatization or regeneration of C8 and C18 reversed-phase HPLC columns with newly introduced reagents were studied. These treatments can increase column life expectancy by restoring retention times and original chromatographic characteristics of the columns. This is illustrated by examples. Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984  相似文献   

11.
The paper describes a new test designed in micellar LC (MLC) to compare the commercial C18 stationary phase properties. This test provides the total hydrophobicity, hydrophilicity, steric selectivity, hydrogen bonding, and ion‐exchange capacity properties calculation of the ODS stationary phases. Both the test compounds and chromatographic separation conditions choice for column characterization in MLC are detailed. The chromatographic performance of several stationary phases that are used in MLC was evaluated with specific chromatographic test comprising nine test compounds, possessing different physico‐chemical properties, which were injected on different supports with two micellar mobile phases: one at pH 7.0 (0.075 mol/L SDS and 1.5% v/v 1‐pentanol), and other at pH 2.7 (0.075 mol/L SDS and 1.5% v/v 1‐pentanol adjusted to pH by TFA). Fundamental column chromatographic properties were obtained under these conditions and were treated by hierarchical cluster analysis. From the results of cluster analysis, two closely related groups of columns are distinguished, and it was shown that the chosen column characteristic parameters allow characterizing both sorbent and micellar chromatographic system properties. Eleven columns were analyzed by this test, which allows a comparison of columns with the aim of the selection of suitable and analogous column for the analysis with MLC.  相似文献   

12.
90Y was separated from 90Sr using an extraction chromatographic resin consisting of 4, 4′(5′)-bis-t-butylcyclohexano-18-crown-6 (DtBuCH18C6), 1-ethyl-3-methylimidazolium bis(trifluoromethanesulfonyl) amide (C2mimNTf2), and a polymer (Amberlite XAD-7). Ionic liquid was introduced into the column to improve the separation efficiency. The column showed an excellent performance for the separation of Y from Sr. After the separation, the ratio of 90Sr/90Y was <2.0 × 10?5; the column was recycled for >18 times. This study provides preliminary results on columns to produce 90Y with a high purity in radiopharmaceuticals.  相似文献   

13.
In this study, a comparative investigation was performed of HPLC Ascentis® (2.7 μm particles) columns based on fused-core particle technology and Acquity® (1.7 μm particles) columns requiring UPLC instruments, in comparison with Chromolith™ RP-18e columns. The study was carried out on mother and vegetal tinctures of Passiflora incarnata L. on one single or two coupled columns. The fundamental attributions of the chromatographic profiles are evaluated using a chemometric procedure, based on the AutoCovariance Function (ACVF). Different chromatographic systems are compared in terms of their separation parameters, i.e., number of total chemical components (mtot), separation efficiency (σ), peak capacity (nc), overlap degree of peaks and peak purity. The obtained results show the improvements achieved by HPLC columns with narrow size particles in terms of total analysis time and chromatographic efficiency: comparable performance are achieved by Ascentis® (2.7 μm particle) column and Acquity® (1.7 μm particle) column requiring UPLC instruments. The ACVF plot is proposed as a simplified tool describing the chromatographic fingerprint to be used for evaluating and comparing chemical composition of plant extracts by using the parameters D% – relative abundance of the deterministic component – and cEACF – similarity index computed on ACVF.  相似文献   

14.
High-performance liquid chromatography (HPLC) has been commonly used as method of separating and identifying photosynthetic pigments such as chlorophylls and carotenoids because of such advantages as speed, high resolution and sensitivity. In this technique, high separation relies largely on the type of column material. This study compared the efficiency of five reverse-phase columns, C8, C18, C18 monolithic, π-NAP, and cholester, for separation of photosynthetic pigments at several fixed conditions of mobile phase and temperature. This investigation also analysed the parameters of ΔtR and tR ratio for selected pigments and resolution for structural isomers, such as α- and β-carotene. Among above columns tested, cholester column is suitable for separation of pigments not only for a broad range of polarity, but also for hydrophobic pigments in a simple mobile phase. This finding can help in the selection of column and HPLC parameters in separating photosynthetic pigments.  相似文献   

15.
An empirical test is described for the evaluation of column selectivity in reversed-phase liquid chromatography. Using a test mixture of three polycyclic aromatic hydrocarbons (PAH), overall column selectivity toward PAH was assessed for over 20 different commercial C18 columns. Retention behavior was correlated to phase type (i.e., monomeric and polymeric surface modification chemistry) for custom synthesized phases. A classification scheme is proposed in which commercial C18 columns are grouped into three classes based on retention behavior: monomeric-like, polymeric-like, and intermediate phase selectivity toward PAH. Correlation of retention behavior of the test mixture with the separation of PAH mixtures and with more general column properties (e.g., phase thickness) is discussed.  相似文献   

16.
The performance of four different reversed-phase columns which included a conventional C18 phase, a C18 polar-endcapped phase, an ether-linked phenyl polar-endcapped phase and a calixarene-bonded phase has been systematically compared for the separation of mixture of some water-soluble vitamins containing basic, neutral and acidic compounds of different polarities, as well as different functional groups at three pH levels and different proportions of buffer/methanol. The characteristics of water-soluble vitamins make this combination of compounds very useful as a test mixture to check column performance with real samples. Due to the physical and chemical differences between these compounds, the type of chosen column has a significant influence on the chromatographic behavior. Results of this comparison show that the C18 polar-endcapped phase was the most suitable for the separation of this group of vitamins. The presence of a polar group as an endcapping agent does not seem to influence the overall hydrophobic nature of the polar-endcapped stationary phases. At the same time, these phases displayed enhanced hydrogen bonding and silanol activity.  相似文献   

17.
Summary A fully integrated chromatographic system was developed for the determination of leukotrienes in biological samples using photodiode-array detection (PDAD), which eliminates time consuming manual sample handling steps. A special solid phase extraction, (SPE) methodology for leucotriene metabolite stability was developed which increased the recoveries and eliminates the contamination risk of biological samples. The inherent instability (autooxidation) of many of the leukotriene mediators, and the adsorption effects onto exposed surfaces in vials and in the chromatographic system were found to be very important parameters to control in order to circumvent high loss of sample analytes. By binding the cell supernatants to the functionalities of the SPE support stabilised these mediators. Cell culture samples were eluted through a disposable C18 SPE column. The SPE columns were allowed to thaw and deposited in an automated sample handling unit (ASPEC XL). Desorption of the analytes was followed by a second on-line SPE step, to eliminate remaining interfering matrix compounds. Typical recoveries when stored at −70°C were in-between 55–97% except for (LTE4) which was found to be around 40% after 72 days of storage. Seven reversed-phase packings were studied. Selectivity factors, as well as the separation efficiencies, were found to differ for the various C18 bonded silica stationary phases. This integrated on-line column liquid chromatographic system was applied to the determination of leukotriene B4, leukotriene C4, leukotriene D4, leukotriene and E4 in human cell extracts using prostaglandin B2 as the internal standard. More than 1500 biological samples were analysed. Some validation data are presented for unattended operations.  相似文献   

18.
The gas chromatographic separation of fatty acid methyl esters (FAMEs) on ionic liquid stationary phases was investigated. Seven commercially available ionic liquid columns were tested using a test mixture containing 37 fatty acid methyl esters. The influence of column temperature on the elution order was studied using five different temperature programs. Retention times were highly reproducible. Similar retention behavior was observed for the IL59, IL60, and IL61 columns. The peak pair C18:1 cis/trans was not baseline resolved on these columns, whose stationary phases are highly similar. C18:2 cis/trans, C18:3 n6/n3, and C20:3 n6/n3 were baseline separated on all columns. Baseline separation of the complete test mix was only obtained on the IL82 column using a heating rate of 5 K/min. In general, retention times decreased with increasing column polarity but unsaturated FAMEs were retained stronger compared to their saturated counterparts. Except for the IL59 column, retention crossover was observed when the temperature program was changed.  相似文献   

19.
A rapid and simple micellar liquid chromatographic method that does not require use of specific chromatographic columns has been developed and validated for azithromycin determination. The method uses a Hypersil C18 column at 60 °C, 1-butanol–pH 6.86 phosphate buffer solution–water, 15:25:60 (v/v), containing 0.10 M sodium dodecyl sulfate, as mobile phase, and UV-detection at 215 nm. Different characteristics of the method were validated satisfactorily. The specificity, accuracy, linearity, precision (repeatability), and robustness of the method were demonstrated. The method proved suitable for determination of the azithromycin content of capsules and uncoated tablets.Revised: 5 February and 11 March 2004  相似文献   

20.
Summary High-performance liquid chromatographic and gas chromatographic methods were developed for the separation of unusual secondary aromatic amino acids. Amino acids containing 1,2,3,4-tetrahydroisoquinoline, 1,2,3,4-tetrahydronorharmane-1-carboxylic acid and 1,2,3,4-tetrahydro-3-carboxy-2-carboline moieties were synthetized in racemic or chiral forms. The high-performance liquid chromatography was carried out either on a teicoplanin-containing chiral stationary phase or on an achiral C18 column. In the latter case the diastereomers of the amino acids formed by precolumn derivatization with the chiral reagents 2,3,4,6-tetra-O-acetyl-β-D-glucopyranosyl isothiocyanate or 1-fluoro-2,4-dinitrophenyl-5-L-alanine amide were separated. The gas chromatographic analyses were based on separation on a Chirasil-L-Val column. Presented at: Balaton Symposium on High-Performance Separation Methods, Siófok, Hungary, September 3–5, 1997  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号