首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
An in situ plated lead film electrode has been applied for adsorptive stripping voltammetric determination of trace concentrations of molybdenum in the presence of Alizarin S. The procedure is based on the preconcentration of the molybdenum-Alizarin S complex at an in situ plated lead film electrode held at −0.6 V (versus Ag/AgCl), followed by a negatively sweeping square wave voltammetric scan. The peak current is proportional to the concentration of molybdenum over the range 2 × 10−9 to 5 × 10−8 mol L−1, with a 3σ detection limit of 9 × 10−10 mol L−1 with an accumulation time of 60 s. The measurements were carried out from underaerated solutions. The proposed procedure was validated in the course of Mo(VI) determination in water certified reference materials.  相似文献   

2.
A novel method of first derivative synchronous fluorescence was developed for the rapid simultaneous analysis of trace 1-hydroxypyrene (1-OHP), 1-naphthol (1-NAP), 2-naphthol (2-NAP), 9-hydroxyphenanthrene (9-OHPe) and 2-hydroxyfluorene (2-OHFlu) in human urine. Only one single scan was needed for quantitative determination of five compounds simultaneously when Δλ = 10 nm was chosen. In the optimal experimental conditions, there was a linear relationship between the fluorescence intensity and the concentration of 1-OHP, 1-NAP, 2-NAP, 9-OHPe and 2-OHFlu in the range of 1.75 × 10−9 to 4.50 × 10−6 mol L−1, 3.64 × 10−8 to 2.20 × 10−4 mol L−1, 8.18 × 10−9 to 1.20 × 10−4 mol L−1, 3.26 × 10−9 to 8.50 × 10−5 mol L−1 and 4.88 × 10−9 to 5.50 × 10−6 mol L−1, respectively. The limits of detection (LOD) were found to be 5.25 × 10−10 mol L−1 for 1-OHP, 1.10 × 10−8 mol L−1 for 1-NAP, 2.46 × 10−9 mol L−1 for 2-NAP, 9.77 × 10−10 mol L−1 for 9-OHPe and 1.46 × 10−9 mol L−1 for 2-OHFlu. The proposed method is reliable, selective and sensitive, and has been used successfully in the determination of traces of 1-OHP, 1-NAP, 2-NAP, 9-OHPe and 2-OHFlu in human urine samples, whose results were in good agreement with those gained by the HPLC method.  相似文献   

3.
A method for determination of nine brominated phenols as environmental risk compounds was developed by on-line coupled capillary isotachophoresis and capillary zone electrophoresis (ITP–CZE). For ITP step, 1 × 10−2 mol L−1 hydrochloric acid with 3 × 10−2 mol L−1 ammediol pH 9.1 was used as the leading electrolyte, and 3 × 10−2 mol L−1 β-alanine with 2 × 10−2 mol L−1 sodium hydroxide pH 10.05 was used as the terminating electrolyte. As the background electrolyte for CZE separation, 2.5 × 10−2 mol L−1 β-alanine with 2.5 × 10−2 mol L−1 lysine pH 9.6 was used. All electrolytes contained 0.05% or 0.1% (m/v) hydroxyethylcellulose to suppress the electroosmotic flow. UV detection at wavelength 220 nm was used. Detection limits in order of tens of nmol L−1 were achieved. Good repeatability of migration times (less than 0.33% RSD) and good repeatability of peak areas (less than 7.19% RSD) at concentration level 5 × 10−8 mol L−1 were observed. Developed ITP–CZE method was applied to determination of brominated phenols in spiked tap and river water samples.  相似文献   

4.
Xiang Y  Mei L  Li N  Tong A 《Analytica chimica acta》2007,581(1):132-136
A new fluorogenic method for the selective and sensitive determination of chromium(VI) in acidic water using rhodamine B hydrazide was developed. This method was based on the oxidation of non-fluorescent rhodamine B hydrazide by potassium dichromate in acidic aqueous conditions to give rhodamine B, which was highly fluorescent, as a product. With the optimum condition described, the fluorescence enhancement at 585 nm was linearly related to the concentration of chromium(VI) in the range of 5.0 × 10−8 to 2.0 × 10−6 mol L−1 (2.60-104 ng mL−1) with a correlation coefficient of R2 = 0.9993 (n = 18) and a detection limit of 5.5 × 10−9 mol L−1 (0.29 ng mL−1). The R.S.D. was 2.2% (n = 5). The proposed method was also applied to the determination of chromium(VI) in drinking water, river water and synthetic samples.  相似文献   

5.
The influence of the boron-doping levels in boron-doped diamond film electrodes on the electrochemical response of nitrofurantoin (NFT) and the development of an electroanalytical procedure for NFT determination were investigated. The investigations were carried out using the techniques of cyclic voltammetry and square wave voltammetry on diamond film electrodes with different boron-doping levels (i.e., 5000, 10,000 and 20,000 mg L−1). The level of boron-doping in the diamond film electrodes influenced the electrochemical reduction of NFT. The appropriate cyclic voltammetric response of NFT was obtained with Britton-Robinson buffer at pH 4 and for diamond films doped with 10,000 and 20,000 mg L−1 of boron. These two films were selected for the development of the electroanalytical procedure. The use of square wave voltammetry with the optimized parameters demonstrated a good linear relationship between the peak current and the NFT concentration for a wide range of concentration. The lower limit of detection for the electrodes doped with 10,000 and 20,000 mg L−1 of boron were 2.69 × 10−8 mol L−1 (6.40 μg L−1) and 8.15 × 10−9 mol L−1 (1.94 μg L−1), respectively, while the lower limits of quantification were 8.96 × 10−8 mol L−1 (21.33 μg L−1) and 2.72 × 10−8 mol L−1 (6.47 μg L−1), respectively. The applicability of the proposed procedure was tested using a commercial pharmaceutical formulation of NFT, and the results were compared with the procedure recommended by the British Pharmacopeia. The proposed procedure was sensitive, accurate and precise for analysis of NFT and did not require complex preparations or renovations of the electrode surface. This presents the advantage of eliminating mercury waste and minimizing the adsorptive problems related to the use of other electrodic solid surfaces.  相似文献   

6.
A simple and highly selective electrochemical method was developed for the single or simultaneous determination of paracetamol (N-acetyl-p-aminophenol, acetaminophen) and caffeine (3,7-dihydro-1,3,7-trimethyl-1H-purine-2,6-dione) in aqueous media (acetate buffer, pH 4.5) on a boron-doped diamond (BDD) electrode using square wave voltammetry (SWV) or differential pulse voltammetry (DPV). Using DPV with the cathodically pre-treated BDD electrode, a separation of about 550 mV between the peak oxidation potentials of paracetamol and caffeine present in binary mixtures was obtained. The calibration curves for the simultaneous determination of paracetamol and caffeine showed an excellent linear response, ranging from 5.0 × 10−7 mol L−1 to 8.3 × 10−5 mol L−1 for both compounds. The detection limits for the simultaneous determination of paracetamol and caffeine were 4.9 × 10−7 mol L−1 and 3.5 × 10−8 mol L−1, respectively. The proposed method was successfully applied in the simultaneous determination of paracetamol and caffeine in several pharmaceutical formulations (tablets), with results similar to those obtained using a high-performance liquid chromatography method (at 95% confidence level).  相似文献   

7.
High-performance liquid chromatography (HPLC) with tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection methodology is reported for the determination of the atypical antipsychotic drug quetiapine and the observation of its major active and inactive metabolites in human urine and serum. The method uses a monolithic chromatographic column allowing high flow rates of 3 mL min−1 enabling rapid quantification. Flow injection analysis (FIA) with tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection and HPLC time of flight mass spectrometry (TOF-MS) were used for the determination of quetiapine in a pharmaceutical preparation to establish its suitability as a calibration standard. The limit of detection achieved with FIA was 2 × 10−11 mol L−1 in simple aqueous solution. The limits of detection achieved with HPLC were 7 × 10−8 and 2 × 10−10 mol L−1 in urine and serum, respectively. The calibration range for FIA was between 5 × 10−9 and 1 × 10−6 mol L−1. The calibration ranges for HPLC were between 1 × 10−7-1 × 10−4 and 1 × 10−8-1 × 10−4 mol L−1 in urine and serum, respectively. The quetiapine concentrations in patient samples were found to be 3 × 10−6 mol L−1 in urine and 7 × 10−7 mol L−1 in serum. Without the need for preconcentration, the HPLC detection limits compared favourably with those in previously published methodologies. The metabolites were identified using HPLC-TOF-MS.  相似文献   

8.
Su Y  Wang J  Chen G 《Talanta》2005,65(2):531-536
Epinephrine was found to be able to strongly enhance the electrochemiluminescence (ECL) of lucigenin system by using the anodic potential sweep. Based on which, a novel ECL method for the determination of epinephrine was developed. Under the optimum condition, the enhanced ECL intensity was linear with the epinephrine concentration in the range of 4.0 × 10−8 to 2.0 × 10−7 mol L−1. The detection limit (defined as S/N = 3) was 2.4 × 10−8 mol L−1, and the relative standard deviation was 2.7% for 1.0 × 10−7 mol L−1 epinephrine (n = 11). The method was successfully applied to the determination of epinephrine in pharmaceutical samples with satisfactory results. In addition, the possible mechanism for the lucigenin ECL system in the presence of epinephrine has also been discussed.  相似文献   

9.
Titanium phosphate grafted on the surface of silica gel (devoted briefly as Si-TiPH) was synthesized and used as bulk modifier to fabricate a renewable three-dimensional chemically modified electrode. The Si-TiPH bulk modified carbon paste electrode was used for the selective determination of dopamine (DA) in the presence of ascorbic acid (AA). The modified electrode offers an excellent and stable response for the determination of DA in the presence of AA. The differential pulse voltammetry peak current was found to be linear with the DA concentration in the range 2 × 10−7 to 1 × 10−6 and 2 × 10−6 to 6 × 10−5 mol L−1. The detection limit of the proposed method in the presence of 2.0 × 10−5 M of AA was found to be 4.3 × 10−8 mol L−1 for DA determination. The proposed method was successfully applied for the determination of DA in injections.  相似文献   

10.
Grabarczyk M  Koper A 《Talanta》2011,84(2):393-399
A differential pulse adsorptive stripping voltammetric method has been developed for molybdenum trace determination in environmental water samples containing organic compounds. It was proved that interferences from the organic matrix such as surface active substances and humic substances could be removed by the addition of resin to the analysed sample prior to voltammetric measurement. The parameters for Mo(VI) determination in the presence of resin, using a hanging mercury drop as the working electrode, were examined systematically for two complexing agents: cupferron and chloranilic acid. The detection limits estimated from 3 times the standard deviation for a low Mo(VI) concentrations were equal to 5 × 10−11 and 3 × 10−10 mol L−1 for cupferron and chloranilic acid, respectively. At the optimized conditions the quantitative Mo(VI) determination in the presence of even 50 mg L−1 of surface active compounds can be performed. The proposed procedures were validated in the course of Mo(VI) determination in certified reference material NASS-5 and in the course of studying recovery of Mo(VI) from spiked river water samples.  相似文献   

11.
In this paper, the electrogenerated chemiluminescence (ECL) from thiol-capped CdTe quantum dots (QDs) was reported. The ECL emission was occurred at −1.1 V and reached a maximum value at −2.4 V when the potential was cycled between 0.0 and −2.5 V. The reduced species of CdTe QDs could react with the coreactants to produce the ECL emission. The CdTe QD concentration (6.64 × 10−7 mol L−1) of ECL is lower than that (1.0 × 10−3 mol L−1) of chemiluminescence (CL). Based on the enhancement of light emission from thiol-capped CdTe QDs by H2O2 in the negative electrode potential, a novel method for the determination of H2O2 was developed. The light intensity was linearly proportional to the concentration of H2O2 between 2.0 × 10−7 and 1.0 × 10−5 mol L−1 with a detection limit of 6.0 × 10−8 mol L−1. Compared with most of previous reports, the proposed method has higher sensitivity for the determination of H2O2. In addition, the ECL spectrum of thiol-capped CdTe QDs exhibited a peak at around 620 nm, which was substantially red shifted from the photoluminescence (PL) spectrum, suggesting the surface states play an important role in this ECL process.  相似文献   

12.
In this work, synergistic flotation of U(VI)-alizarin complex at the presence of some diamine compounds was firstly investigated by the spectrophotometric method. The flotation process was carried out on aliquots of 100 ml of U(VI) solutions containing alizarin and the diamine at pH of 5.00 using n-heptane. The floated layer was then dissolved in acetonitrile and its absorbance was measured. Since the synergistic effect of 4,4′-diaminophenylmethane (dapm) was much more than the others, it was used for the determination of U(VI) by this method. Beer's law was obeyed (λmax = 591 nm) in the range of 5 × 10−7 to 1 × 10−5 mol l−1 with the apparent molar absorptivity of 1.12 × 106 l mol−1 cm−1, and a correlation coefficient of 0.9991. The detection limit (n = 7) was 1 × 10−7 mol l−1, and the R.S.D. (n = 7) obtained for 4 × 10−6 mol l−1 of U(VI) was 2.23%. Except that only a few analogous cations, which could be masked by EDTA, no interference was observed at the presence of various conventional ions, even at high concentrations. The reliability and applicability of the method were confirmed using some geological standard reference materials and spiked synthetic water samples, respectively.  相似文献   

13.
Amir Waseem 《Talanta》2007,71(1):56-61
A flow injection (FI) method is reported for the determination of thyroxine based on its enhancement of chemiluminescence (CL) from the Ru(bpy)33+-NADH system. The calibration graph was linear over the range 2.0-10 × 10−8 mol L−1 (r2 = 0.9989) with relative standard deviations (R.S.D.) in the range 2.0-4.5% (n = 4). The limit of detection (3σ blank) was 1.0 × 10−9 mol L−1 with sample throughput of 120 h−1. The effect of some organic compounds, anions and cations were studied for l-thyroxine determination. The method was applied to pharmaceutical preparations and the results obtained were in reasonable agreement with the amount labeled. The method was statistically compared with the results obtained by RIA; no significant disagreement at 95% confidence limit was observed. A calibration graph of NADH over the range 1.3 × 10−8-1.3 × 10−6 mol L−1 was also established (r2 = 0.9992) with R.S.D. in the range1.0-3.5% (n = 4). The limit of detection (3σ) was 1.0 × 10−10 mol L−1 NADH.  相似文献   

14.
Locatelli C 《Talanta》2011,85(1):546-550
An extremely sensitive stripping voltammetric procedure for ultra-trace determination of iridium(III) is reported. The method is based on the interfacial accumulation of the iridium(III)-CTAB complex onto the glassy carbon electrode, followed by the catalytic reduction of the adsorbed complex in the presence of bromate. 0.3 mol L−1 acetate buffer pH 4.7 + 6.9 × 10−2 mol L−1 NaBrO3 + 2.7 × 10−5 mol L−1 cetyltrimethylammonium bromide (CTAB) + 0.2 mol L−1 KCl was employed as the supporting electrolyte.The analytical procedure was verified by the analysis of the standard reference materials: Sea Water BCR-CRM 403 and Fresh Water NIST-SRM 1643d.The accuracy, expressed as relative error e%, was satisfactory, being lower than 6%, while precision as repeatability, expressed as relative standard deviation sr%, was generally lower than 5%. The limit of detection was of the order of 2-3 ng L−1.Once set up on the standard reference materials, the analytical procedure was transferred and applied to superficial water sampled in proximity to superhighway and in the Po river mouth area.  相似文献   

15.
Tang B  Zhang L  Xu KH 《Talanta》2006,68(3):876-882
A new kind of near-infrared fluorescence agent, tricarbochlorocyanine dye (Cy.7.Cl), had been synthesized in house and used for near-infrared spectrofluorimetric determination of hydrogen peroxide (H2O2) by flow injection analysis (FIA) for the first time. The oxidation reaction of Cy.7.Cl with H2O2 occurred under the catalysis of horseradish peroxidase (HRP) and it was studied in detail. The possible reaction mechanism was discussed. Under optimal experimental conditions, fluorescence from Cy.7.Cl displayed excitation and emission maxima (ex/em) at 780 and 800 nm, respectively. The two linear working ranges were 1.86 × 10−7 to 4.11 × 10−7 mol L−1 and 4.11 × 10−7 to 7.19 × 10−6 mol L−1, respectively. The detection limit was 5.58 × 10−8 mol L−1 of H2O2. The effect of interferences was studied. The proposed method was successfully applied to the determination of hydrogen peroxide in rainwater, serum and plant samples.  相似文献   

16.
A sensitive method of Co(II) determination by adsorptive stripping voltammetry is presented. The method exploits the enhancement of cobalt peak current observed in the system Co(II)-nioxime-cetyltrimethylammonium bromide-piperazine-N,N′-bis(2-ethanesulfonic acid). The calibration plot for an accumulation time of 60 s is linear from 5 × 10−11 to 3 × 10−9 mol L−1. The relative standard deviation is 3.8% for Co(II) determination at concentration 1 × 10−9 mol L−1. The detection limit is 1.7 × 10−11 mol L−1. The validation of the method is performed by the analyses of certified reference materials and comparing the result of Co(II) determination in river water sample by the proposed method with those obtained by ET AAS. The main advantage of this new system is the micro-trace Co(II) determination by adsorptive stripping voltammetry, as compared to those described before, a low concentration of the supporting electrolyte used, and so commercially available reagents without additional purification can be used.  相似文献   

17.
Xi Cheng 《Talanta》2007,71(3):1083-1087
In this paper, a polyamide-modified carbon paste electrode in capillary zone electrophoresis with amperometric detection (CZE-AD) was firstly applied to the determination of four carbamate pesticides: fenobucarb, isoprocarb, metolcarb and carbaryl. The four carbamates were hydrolyzed in alkalescent aqueous solutions, resulting in the formation of 2-sec-butylphenol, 2-isopropylphenol, m-cresol and α-naphthol, which could be determined by amperometry after capillary electrophoretic separation. Under the selected optimum conditions, the four analytes could be perfectly separated within 23 min. The linear ranges of 2-sec-butylphenol, 2-isopropylphenol and m-cresol were from 1.0 × 10−7 to 2.0 × 10−5 mol L−1 and that of α-naphthol was from 2.0 × 10−7 to 2.0 × 10−5 mol L−1 and their detection limits were 3.0 × 10−8, 3.0 × 10−8, 3.0 × 10−8 and 6.0 × 10−8 mol L−1, respectively (S/N = 3). Fenobucarb, isoprocarb, metolcarb and carbaryl can be indirectly determined by this CZE-AD method with recovery of 105, 104, 110 and 98% and R.S.D. of 4, 3, 4 and 3%, respectively. Above results demonstrated that this method was of high sensitivity, good repeatability and could be used in the rapid determination of the pesticide residues.  相似文献   

18.
Zhao L  Tao Y  Yang X  Zhang L  Oyama M  Chen X 《Talanta》2006,70(1):104-110
Electrogenerated chemiluminescences (ECLs) of alkaloids, such as berberine, trigonelline, allantoin and betaine, were studied in an aqueous alkaline buffer solution (pH 9.5), based on tris(2,2′-bipyridine)ruthenium(II) [Ru(bpy)32+] immobilized in organically modified silicates (ORMOSILs) film on a glassy carbon electrode (GCE). The immobilized Ru(bpy)32+ showed good electrochemical and photochemical activities. In a flow system, the eluted alkaloids were oxidized on the modified GCE, and reacted with immobilized Ru(bpy)32+ at the potential of +1.50 V (versus Ag/AgCl). The luminescence with λmax 610 nm was caused by a reaction of electrolytically formed Ru(bpy)33+ with an oxidized amine group to generate Ru(bpy)32+*. The determination limit was 5 × 10−6 mol L−1, 8 × 10−6 mol L−1, 2.0 × 10−5 mol L−1 and 5.0 × 10−5 mol L−1 for berberine, trigonelline, allantoin and betaine at S/N 3, respectively. In addition, the factors affecting the determination of the four alkaloids were also studied.  相似文献   

19.
A novel method for the simultaneous determination of 1-hydroxypyrene (1-OHP), β-naphthol (β-NAP) and 9-hydroxyphenanthrene (9-OHPe) in human urine has been established by using synchronous fluorescence spectrometry. It was based on the fact that synchronous fluorescence spectrometry can resolve the broad-band overlapping of conventional fluorescence spectra, which arise from their similar molecular structures. Only one single scan is needed for quantitative determination of three compounds simultaneously when Δλ = 15 nm is chosen. The signals detected at these three wavelengths, 369.6, 330.0 and 358.0 nm, vary linearly when the concentration of 1-OHP, β-NAP and 9-OHPe is in the range of 2.16 × 10−8-1.50 × 10−5 mol L−1, 1.20 × 10−7-1.10 × 10−5 mol L−1 and 1.07 × 10−7-3.50 × 10−5 mol L−1, respectively. The correlation coefficients for the standard calibration graphs were 0.994, 0.999 and 0.997 (n = 7) for 1-OHP, β-NAP and 9-OHPe, respectively. The limits of detection (LOD) for 1-OHP, β-NAP and 9-OHPe were 6.47 × 10−9 mol L−1, 3.60 × 10−8 mol L−1 and 3.02 × 10−8 mol L−1with relative standard deviations (R.S.D.) of 4.70-6.40%, 2.80-4.20%, 3.10-4.90% (n = 6), respectively. The method described here had been applied to determine traces of 1-OHP, β-NAP and 9-OHPe in human urine, and the obtained results were in good agreement with those obtained by the HPLC method. In addition, the interaction modes between β-cyclodextrin (β-CD) and 1-OHP, β-NAP or 9-OHPe, as well as the mechanism of the fluorescence enhancement were also discussed.  相似文献   

20.
The polyamines, octyl-[2-(2-octylamino-ethylamino)-ethyl]-amine (L1) and octyl-{2-[2-(2-octylamino-ethylamino)-ethylamino]-ethyl}-amine (L2), have been used as anion ionophores in PVC-based membrane ion-selective electrodes. Different electrodes were prepared containing L1, or L2, and o-nitrophenyl octyl ether (NPOE) or bis(2-ethylhexyl)sebacate (DOS) as plasticizers. The response of the electrodes was tested in two different buffers, HEPES-KOH (pH 7) and MES-KOH (pH 5.6). Electrodes containing L1 and L2 with NPOE (E1 and E2, respectively) showed a Nernstian response for thiocyanate with a good response time. The detection limit, linear range and slope for electrode E1 were 3.8 × 10−6 mol dm−3, 1 × 10−5 to 1 × 10−1 mol dm−3 and −57.2 mV decade−1 at pH 5.6 and 4.47 × 10−6 mol dm−3, 1.95 × 10−5 to 1 × 10−1 mol dm−3 and −58.1 mV decade−1 at pH 7.0. For electrode E2 the detection limit, linear range and slope found were 2.63 × 10−6 mol dm−3, 7.94 × 10−6 to 1 × 10−1 mol dm−3 and −58.5 mV decade−1 at pH 5.6 and 1.23 × 10−5 mol dm−3, 7.95 × 10−5 to 1 × 10−1 mol dm−3 and −46.0 mV decade−1 at pH 7. In contrast, electrodes containing DOS as plasticizers gave only response at pH 5.6 (detection limit, linear range and slope at pH 5.6 were 3.16 × 10−5 mol dm−3, 1 × 10−4 to 1 × 10−1 mol dm−3 and −52.6 mV decade−1). Selectivity coefficients for different anions with respect to thiocyanate were calculated. The electrode E2 at pH 5.6 was also used for the determination of SCN by potentiometric titrations with Ag+ ions with good results. The electrode E2 was also used to determine concentrations of thiocyanate in biological samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号