首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new method was developed for the determination of cadmium in water samples using ionic liquid-based ultrasound-assisted dispersive liquid–liquid microextraction (IL-based USA-DLLME) followed by electrothermal atomic absorption spectrometry (ETAAS). The IL-based USA-DLLME procedure is free of volatile organic solvents, and there is no need for a dispersive solvent, in contrast to conventional DLLME. The ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate (HMIMPF6), was quickly disrupted by an ultrasonic probe for 1 min and dispersed in water samples like a cloud. At this stage, a hydrophobic cadmium–DDTC complex was formed and extracted into the fine droplets of HMIMPF6. After centrifugation, the concentration of the enriched cadmium in the sedimented phase was determined by ETAAS. Some effective parameters of the complex formation and microextraction, such as the concentration of the chelating agent, the pH, the volume of the extraction solvent, the extraction time, and the salt effect, have been optimized. Under optimal conditions, a high extraction efficiency and selectivity were reached for the extraction of 1.0 ng of cadmium in 10.0 mL of water solution employing 73 µL of HMIMPF6 as the extraction solvent. The enrichment factor of the method is 67. The detection limit was 7.4 ng L− 1, and the characteristic mass (m0, 0.0044 absorbance) of the proposed method was 0.02 pg for cadmium (Cd). The relative standard deviation (RSD) for 11 replicates of 50 ng L− 1 Cd was 3.3%. The method was applied to the analysis of tap, well, river, and lake water samples and the Environmental Water Reference Material GSBZ 50009-88 (200921). The recoveries of spiked samples were in the range of 87.2–106%.  相似文献   

2.
A novel switchable solvent (SS) extraction methodology has been used for the enrichment of aluminium (Al) in acid‐digested blood samples of patients with neurological disorders before proceeding to flame atomic absorption spectrometry. 1,8‐Diazabicyclo[5.4.0]undec‐7‐ene and decanol in combination made a SS which reversibly changes from hydrophobic (nonpolar) to hydrophilic (polar) according to switch‐on and switch‐off phenomena in aqueous medium by exposure to anti‐solvent trigger (CO2). The SS polar micro‐emulsion was switched on by bubbling CO2, and switched off by heating from 40 to 70°C with exposure to N2 gas. The changes obtained in the structure and physical properties of the SS due to switching from lower polarity to higher polarity were investigated using Fourier transform infrared spectroscopic analysis. The SS was effectively analysed as an extractive medium for hydrophobic chelate of Al with 3,5,7,2,4‐pentahydroxyflavone (morin) and extracted in SS. Then hydrophobic enriched Al‐morin‐SS was treated with 1.0 M HNO3 and CO2 purging at various time intervals, switch to a miscible polar hydrophilic monophase state. The SS was easily recycled up to six times for further enrichment process. For the developed method, various parameters were optimized such as pH, volume of chelating reagent, CO2 purging time and pressure, and rate of heating. Under favourable conditions, enhancement factor and limit of detection were observed as 25 and 0.47 μg l?1, respectively, for 10 ml of samples/standards solution. The accuracy of the developed method was determined using certified reference material (SRM 3101a), with a standard addition procedure. The method was used for the pre‐concentration of Al in blood samples of patients with neurological disorders.  相似文献   

3.
In this research, we combined ionic liquid-based dispersive liquid-liquid micro-extraction (IL-based DLLME) with stopped-flow spectrofluorometry (SFS) to evaluate the concentration of aluminum in different real samples at trace level. 1-Hexylpyridinium hexafluorophosphate [Hpy][PF6] ionic liquid and 8-hydroxyquinoline (oxine), which forms a highly fluorescent complex with Al3+, were chosen as the extraction solvent and chelating agent, respectively. The hydrophobic Al-oxine complex was extracted into the [Hpy][PF6] and separated from the aqueous phase. Then, the concentration of the enriched aluminum in the sediment phase was determined by SFS. Some effective parameters that influence the SFS signals and the micro-extraction efficiency, such as the suction and sending time, the concentration of the chelating agent, pH, the amount of the ionic liquid, the type of disperser solvent and diluting agent, ionic strength, extraction time, equilibration temperature and centrifugation time were investigated and optimized. In the optimum experimental conditions, the limit of detection (3 s) and enrichment factor were 0.05 μg L−1 and 100, respectively. The relative standard deviation (RSD) for six replicate determinations of 6 μg L−1 Al was 1.7%. The calibration graph using the pre-concentration system was linear in the range of 0.06-15 μg L−1 with a correlation coefficient of 0.9989. The developed method was validated by the analysis of certified reference materials and applied successfully to the determination of aluminum in several water, fruit juice and food samples.  相似文献   

4.
Abstract

Lacinilene C 7-methyl ether (an implicated causative agent of byssinosis), lacinilene C, and their immediate cadalene precursors were extracted from dried green cotton bracts into water. These compounds were then quantitatively adsorbed from water and concentrated on SEP-PAK C18 Cartridges. The lacinilenes, and their cadalene precursors were then separated on a μBONDAPAK C18 column. A new sample preparation strategy for SEP-PAK C18 Cartridges was developed, in which the loaded Cartridge was dried with N2 gas and eluted with the most non-polar solvent that would totally release the compound(s) in question. Consequently, due to insolubility, many adsorbed undesirable compounds were not eluted. This strategy is highly selective and allows for a quick, convenient, yet quantitative recovery, and should have wide applicability to the isolation of hydrophobic compounds.  相似文献   

5.
A novel type of solvent named deep eutectic solvent (DES) has been considered as a green ionic liquid analogue. A novel method was developed for enrichment and speciation of chromium ion from water and food samples based on deep eutectic solvent and ultrasonic extraction. The procedure for this method was comprised of Cr(III) complex formation with a hydrophobic complexing agent (Z)‐N‐(3,5‐diphenyl‐1H‐pyrrol‐2‐yl)‐3,5‐diphenyl‐2H‐pyrrol‐2‐imine (azadipyrromethene dye). Metal complex was entrapped in a deep eutectic solvent as an extracting solvent. While Cr(III) recovery was quantitative, the recovery of Cr(VI) was found 5%. After reduction of Cr(VI) to Cr(III), the method was applied for determination of total chromium(III) ion. The amount of Cr(VI) was calculated as subtracting of Cr(III) from total chromium ion. Various analytical parameters were optimized. The certified reference materials were analyzed and standard addition method also carried out to real samples to check the accuracy of the developed method. Preconcentration factor was found to be 50. The limit of detection of chromium(III) was found to be 4.3 ng l‐1. The precision of developed method as the relative standard deviation (RSD) was found as 3.5 %. The developed method was applied successfully for the speciation of chromium ions in water and food samples.  相似文献   

6.
We report on a new method for the dispersive liquid-liquid microextraction of Cd(II), Co(II), Pb(II) and Ni (II) from water samples prior to their simultaneous determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The procedure is based on the injection of a ternary solvent system composed of appropriate quantities of extraction solvent (trichloroethylene), dispersive solvent (ethanol), and the chelating reagent 2-(2′-benzothiazolylazo)-p-cresol into the sample solution. The solution turns turbid immediately after injection, and the analytes are extracted into the droplets of the organic phase which was dried and dissolved in a mixture of Triton X-114, nitric acid, and ethanol. The metal ions in this mixture were quantified by ICP-OES. The detection limits under optimized conditions are 0.2, 0.3, 0.2 and 0.7?μg?L?1 for Cd(II), Co(II), Pb(II) and Ni(II), respectively. The enrichment factors were also calculated for Cd (13), Co (11), Pb (11) and Ni (8). The procedure was applied to the determination of cadmium, cobalt, lead and nickel in certified reference material (waterway sediment) and water samples.
Figure
A new method for the dispersive liquid-liquid microextraction of Cd(II), Co(II), Pb(II) and Ni(II) from water samples prior to their simultaneous determination by inductively coupled plasma optical emission spectrometry (ICP OES) is presented. The procedure was applied to the determination of elements in samples of river and lake water.  相似文献   

7.
Mass transfer in rectangular chromatographic channels   总被引:6,自引:0,他引:6  
  相似文献   

8.
The nitrogen (δ15N) and oxygen isotope (δ18O) analysis of nitrate (NO3) from aqueous samples can be used to determine nitrate sources and to study N transformation processes. For these purposes, several methods have been developed; however, none of them allows an accurate, fast and inexpensive analysis. Here, we present a new simple method for the isolation of nitrate, which is based on the different solubilities of inorganic salts in an acetone/hexane/water mixture. In this solvent, all major nitrate salts are soluble, whereas all other oxygen‐bearing compounds such as most inorganic carbonates, sulfates, and phosphates are not. Nitrate is first concentrated by freeze‐drying, dissolved in the ternary solvent and separated from insoluble compounds by centrifugation. Anhydrous barium nitrate is then precipitated in the supernatant solution by adding barium iodide. For δ18O analysis, dried Ba(NO3)2 samples are directly reduced in a high‐temperature conversion system to CO and measured on‐line using isotope ratio mass spectrometry (IRMS). For δ15N analysis, samples are combusted in an elemental analyzer (EA) coupled to an IRMS system. The method has been tested down to 20 µmol NO3 with a reproducibility (1SD) of 0.1‰ for nitrogen and 0.2–0.4‰ for oxygen isotopes. For nitrogen we observed a small consistent 15N enrichment of +0.2‰, probably due to an incomplete precipitation process and, for oxygen, a correction for the incorporation of water in the precipitated Ba(NO3)2 has to be applied. Apart from being robust, this method is highly efficient and low in cost. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
Octyl‐functionalized hybrid magnetic mesoporous (Fe3O4·nSiO2·meso‐hybrid‐C8) microspheres were synthesized and applied in the isolation and pre‐concentration of low‐concentration peptides prior to direct analysis by matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS). Such microspheres possess high surface area (324 m2/g), hydrophobic group (C8), relatively large pore volume (0.304 cm3/g), uniform pore diameter (~3.7 nm), and magnetic responsivity, which make them a simple and efficient kind of adsorbent for the enrichment of low‐concentration peptides. For bovine serum albumin (BSA, 15 fmol μL–1) digest, after concentration by Fe3O4·nSiO2·meso‐hybrid‐C8 microspheres, the enrichment performance was evidently better than those obtained by solvent evaporation and C8‐functionalized magnetic particles, and comparable to those obtained by commercial Anchor chip target and ZipTipC18 pipette tip. Such microspheres were further applied in the enrichment of the tryptic digests of rat cerebellum proteins and endogenous peptides of crude human serum, and more peaks with higher signal‐to‐noise (S/N) ratio were obtained than before pre‐concentration. Furthermore, the pre‐concentration reproducibility of magnetic microspheres for biological samples was good, and the limit of detection (LOD) for BSA digests by MALDI‐TOF MS was decreased by at least one order of magnitude compared with that obtained without pre‐concentration. All the above‐mentioned results indicate that the synthesized Fe3O4·nSiO2·meso‐hybrid‐C8 microspheres are promising for the enrichment of low‐concentration peptides from complex biosamples. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
Recovering critical metals from secondary resources have attracted great interest recently.In this work,a green one-pot leaching-extraction process based on tributyl(tetradecyl)phosphonium chloride (P44414Cl)aqueous biphasic system (ABS) was developed to efficiently recover rare earth elements (REEs) from Nd Fe B permanent magnet.The reaction process,phase separation mechanism,and operation conditions were thoroughly investigated.It is found that the P44414Cl-HCl ABS showed...  相似文献   

11.
以二硫化碳为萃取剂,丙酮为分散剂对水样和土壤样中残留的多环芳烃进行分散液相微萃取。提取液供高效液相色谱仪的二极管阵列检测器和荧光检测器测定。选用LiChrospherPAH色谱柱作为固定相,用乙腈和水以不同比例混合的溶液作为流动相进行梯度淋洗。在优化的试验条件下,对合成水样中多环芳烃的富集倍数达220~560倍,16种多环芳烃可有效分离并测定。16种多环芳烃的检出限(3S/N)在0.002~0.05μg.L-1之间。用标准加入法测得回收率在64%~108%之间,测定值的相对标准偏差(n=7)在2.0%~7.8%之间。  相似文献   

12.
Task-specific ionic liquid dispersive liquid–liquid microextraction (TSIL-DLLME) is a simple and rapid preconcentration approach for the measurement of cadmium in serum and blood samples of human subjects. In this method a novel task-specific ionic liquid, trioctylmethyl ammonium thiosalicylate (TOMATS), which has dual characteristics as a chelating agent and extractive solvent, was investigated. TOMATS complexes with Cd due to the chelating effect of the ortho-positioned carboxylate relative to the thiol functionality. The assessment of the optimum values of variables including the pH, amount of reagents (TOMATS, diluents, Triton X114, and back extracting acid solution), temperature, and incubation time, which affect the recoveries of analyte by TSIL-DLLME method were studied. After enrichment experiments, acidic solution was used to back extract the metal ions from the ionic liquid rich phase and with determination by electrothermal atomic absorption spectrometry. Using the optimal experimental conditions, the limit of detection (3?s), precision (relative standard deviation), preconcentration, and enhancement factors of developed method for Cd were found to be 0.05?µg/L, greater than 5%, 62.5, and 52.8, respectively. To check the accuracy of the developed method, certified reference material of serum and blood were analyzed by the developed method, and the measured values of Cd were in good agreement with the certified values. The developed method was applied successfully to determine Cd in blood and serum samples of lymphatic cancer patients relative to healthy controls.  相似文献   

13.
We report on the application of emulsification-based dispersive liquid microextraction (EB-DLME) to the preconcentration of Cd(II). This procedure not only possesses all the advantages of routine DLLME, but also results in a more stable cloudy state which is particularly useful when coupling it to FAAS. In EB-DLME, appropriate amounts of the extraction solvent (a solution of dithizone in chloroform) and an aqueous solution of sodium dodecyl sulfate (SDS; acting as a disperser) are injected into the samples. A stable cloudy microemulsion is formed and Cd(II) ion is extracted by chelation. After phase separation, the sedimented phase is subjected to FAAS. Under optimized conditions, the calibration curve for Cd(II) is linear in the range from 0.1 to 25 μg L?1, the limit of detection (at S/N?=?3) is 30 pg L?1, the relative standard deviations for seven replicate analyses (at 0.56 μg L?1 of Cd(II)) is 4.6 %, and the enrichment factor is 151. EB-DLME in our opinion is a simple, efficient and rapid method for the preconcentration of Cd(II) (and most likely of many other ions) prior to FAAS determination.
Figure
Emulsification based dispersive liquid microextraction is presented for determination of cadmium in water samples  相似文献   

14.
A novel microextraction method, termed microwave‐assisted ionic liquid/ionic liquid dispersive liquid–liquid microextraction, has been developed for the rapid enrichment and analysis of triazine herbicides in fruit juice samples by high‐performance liquid chromatography. Instead of using hazardous organic solvents, two kinds of ionic liquids, a hydrophobic ionic liquid (1‐hexyl‐3‐methylimidazolium hexafluorophosphate) and a hydrophilic ionic liquid (1‐butyl‐3‐methylimidazolium tetrafluoroborate), were used as the extraction solvent and dispersion agent, respectively, in this method. The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of 1‐hexyl‐3‐methylimidazolium hexafluorophosphate dispersed entirely into sample solution with the help of 1‐butyl‐3‐methylimidazolium tetrafluoroborate. In addition, an ion‐pairing agent (NH4PF6) was introduced to improve recoveries of the ionic liquid phase. Several experimental parameters that might affect the extraction efficiency were investigated. Under the optimum experimental conditions, the linearity for determining the analytes was in the range of 5.00–250.00 μg/L, with the correlation coefficients of 0.9982–0.9997. The practical application of this effective and green method is demonstrated by the successful analysis of triazine herbicides in four juice samples, with satisfactory recoveries (76.7–105.7%) and relative standard deviations (lower than 6.6%). In general, this method is fast, effective, and robust to determine triazine herbicides in juice samples.  相似文献   

15.
A new pretreatment method, SPE combined with dispersive liquid–liquid microextraction, was proposed for the determination of abamectin in citrus fruit samples for the first time. In this method, fruit samples were extracted by ultrasound‐assisted extraction followed by SPE. Then, the SPE was used as a disperser solvent in the next dispersive liquid–liquid microextraction step for further purification and enrichment of abamectin. The effects of various parameters on the extraction efficiency of the proposed method were investigated and optimized. Good linearity of abamectin was obtained from 0.005 to 10.0 mg/kg for B1a and from 0.05 to 10.0 mg/kg for B1b with correlation coefficient (r2) of 0.998 for B1a and 0.991 for B1b, respectively. The LODs were 0.001 and 0.008 mg/kg (S/N = 3) for B1a and B1b, respectively. The relative recoveries at three spiked levels were ranged from 87 to 96% with the RSD less than 11% (n = 3). The method has been successfully applied to the determination of abamectin in citrus fruit samples.  相似文献   

16.
Dispersive liquid–liquid microextraction (DLLME) technique was successfully used as a sample preparation method for graphite furnace atomic absorption spectrometry (GF AAS). In this extraction method, 500 μL methanol (disperser solvent) containing 34 μL carbon tetrachloride (extraction solvent) and 0.00010 g Salen(N,N′‐bis(salicylidene)ethylenediamine) (chelating agent) was rapidly injected by syringe into the water sample containing cadmium ions (interest analyte). Thereby, a cloudy solution formed. The cloudy state resulted from the formation of fine droplets of carbon tetrachloride, which have been dispersed, in bulk aqueous sample. At this stage, cadmium reacts with Salen(N,N′‐bis(salicylidene)‐ethylenediamine), and therefore, hydrophobic complex forms which is extracted into the fine droplets of carbon tetrachloride. After centrifugation (2 min at 5000 rpm), these droplets were sedimented at the bottom of the conical test tube (25 ± 1 μL). Then a 20 μL of sedimented phase containing enriched analyte was determined by GF AAS. Some effective parameters on extraction and complex formation, such as extraction and disperser solvent type and their volume, extraction time, salt effect, pH and concentration of the chelating agent have been optimized. Under the optimum conditions, the enrichment factor 122 was obtained from only 5.00 mL of water sample. The calibration graph was linear in the range of 2‐21 ng L?1 with a detection limit of 0.5 ng L?1. The relative standard deviation (R.S.D.s) for ten replicate measurements of 20 ng L?1 of cadmium was 2.9%. The relative recoveries of cadmium in tap, sea and rain water samples at a spiking level of 5 and 10 ng L?1 are 99, 94, 97 and 96%, respectively. The characteristics of the proposed method have been compared with cloud point extraction (CPE), on‐line liquid‐liquid extraction, single drop microextraction (SDME), on‐line solid phase extraction (SPE) and co‐precipitation based on bibliographic data. Therefore, DLLME combined with GF AAS is a very simple, rapid and sensitive method, which requires low volume of sample (5.00 mL).  相似文献   

17.
The uptake behavior of porous silica modified with N‐propylsalicylaldimine (IE11) for Cd(II), Cr(III), Cu(II), Mn(II) and Pb(II) metal ions were studied. The Log kd values were found to be within the range 2.19–5.16 depending on pH and time of stirring. IE11 was used in the separation and preconcentration of Cd(II), Cr(III), Cu(II), Mn(II) and Pb(II) from some natural water samples. The data were compared with those obtained by the solvent extraction method (APDC/MIBK). The method was found to be accurate and precise and not subject to random error.  相似文献   

18.
A simple and highly sensitive method developed for preconcentration and spectrophotometric determination of ultra trace amounts of azide ion (N 3 ? ) in water and biological samples using dispersive liquid-liquid microextraction (DLLME) technique. The method is based on ion association formation of azide ion with malachite green and extraction of the ion pairing product using DLLME technique. Some important parameters, such as reaction conditions and the kind and volume of extraction solvent and disperser solvent were studied and optimized. The calibration curve was linear in the range of 0.5–50 μg/L of azide ion. Also, the enrichment factor and extraction recovery obtained were 24.7 and 98.7%, respectively. The method was applied to the determination of azide ion in water and biological samples.  相似文献   

19.
Topping JJ  MacCrehan WA 《Talanta》1974,21(12):1281-1286
Studies were made of the solvent extraction of cadmium(II) from hydrochloric acid into a tri-n-octylamine—cyclohexene mixture. Distribution ratios, as a function of amine and acid concentration, were determined and this information was used to establish optimum extraction conditions and the probable nature of the extracted species. This system was used as the basis for the development of a reversed-phase column chromatographic technique for preconcentrating Cd(II). The amine—cyclohexene phase was coated on an inert macroreticular resin (XAD-2) to provide a stable column. With this system, Cd(II) in acidified water samples as large as 31. may be concentrated to 10 ml and determined by conventional atomic absorption. Interferences were studied, and the method was applied to the analysis of fresh-water streams for Cd(II).  相似文献   

20.
    
The solvent extraction of cobalt(II), nickel(II) and copper(II) using 2,4-pent-dione (Hacac) and 4-phenyl-2, 4-but-dione (Hbzac) is carried out by varying the reagent concentration and pH of the aqueous phase. Each of these metals is quantitatively separated (≈ 98%) from their binary mixtures with monovalent (Ag), divalent (Mn, Zn, Cd, Hg, Mg, Sn, Pb) and trivalent (Cr, Fe) metals. The extraction constants are calculated from the metal distribution data using linear regression analysis. The extracted species is MA2 in each case. A most significant result is separation of copper(II) from iron(III) which otherwise interferes when extracted from the acidic medium.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏