首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
This study presents a quantitative estimation of the analysis and fate of several emerging pollutants, some of them endocrine-disrupting compounds, in surface water samples collected at several locations along the Ter River and two of its tributaries. Influent and effluent waters and particulate matter from five sewage treatment plants (STP) that discharge into these rivers were also studied. The target compounds analyzed were: nonylphenol ethoxylates (NPEO), nonylphenol (NP), octylphenol (OP), bisphenol A (BPA), phthalates, alcohol ethoxylates (AEO) and benzothiazoles. Chemical analysis by liquid chromatography–mass spectrometry using an electrospray interface (LC–ESI–MS) revealed the presence of low amounts (between 0.06 and 17.5 μg L−1) of the target compounds NPE1+2O and NP, which were detected in 100% and 84% of the samples respectively. Maximum concentrations occurred in the STPs associated with the municipalities of Vic and Girona. From the fate and behavior data obtained for the various compounds analyzed in the STP influent and effluent, we can conclude that the STPs are effective at removing large amounts (more than 70%) of the compounds studied from the water.   相似文献   

2.
In recent years perfluorinated alkylated substances (PFAS) have appeared as a new class of global pollutant. Besides being an industrially important group of compounds, PFAS are regarded as highly toxic and extraordinarily persistent chemicals that pervasively contaminate human blood and wildlife throughout the world. They are therefore regarded as PBT (persistent, bioaccumulative, and toxic) chemicals. Two comprehensive methods have been developed for determination of eleven of the most environmentally relevant PFAS (seven perfluoroalkylcarboxylates, two perfluoroalkylsulfonates, and two perfluoroctanesulfonamides) in aqueous samples. The compounds were isolated by liquid–liquid extraction (LLE) and solid-phase extraction (SPE), and identification and quantification of the target analytes were achieved by liquid chromatography–electrospray ionization–tandem mass spectrometry (LC–ESI–MS–MS). With LLE detection limits ranged from 0.26 to 0.62 ng L−1 for enrichment of 900-mL water samples; recovery of PFAS with a carbon chain longer than C7 was excellent (80–93%). With SPE, carboxylates with carbon chains <C10 could be extracted efficiently (70–98%) under acidic conditions, and PFOS and PFOSA could be extracted efficiently (81% and 96%, respectively) under basic conditions, resulting in MDLs between 0.25 and 0.64 ng L−1. The LLE method was applied successfully to Austrian wastewater effluent samples.  相似文献   

3.
An analytical procedure based on extraction by accelerated solvent extraction (ASE) followed by gas chromatography–mass spectrometry (GC/MS) analysis has been developed for the determination of particulate polycyclic aromatic hydrocarbons (PAHs) from large-volume water samples (20 L). The effect of temperature and number of cycles on the efficiency of ASE was investigated: the best results were obtained by using a temperature of 100°C and one static cycle. A mixture of hexane/acetone 1:1 (v/v) was used as extraction solvent. Mean total method recovery under optimized conditions was 85%. The developed methodology was applied to the analysis of suspended particulate matter from Lake Maggiore waters (north of Italy). Mean PAH concentrations in suspended particulate matter from Lake Maggiore ranged from 0.2 ng L−1 for anthracene to 18.7 ng L−1 for naphthalene.  相似文献   

4.
Although there is increasing concern about residues from personal care products entering the aquatic environment and their potential to accumulate to levels that pose a health threat to humans and wildlife, we still know little about the extent and magnitude of their presence in the aquatic environment. In this study we describe a procedure for isolation, and subsequent determination, of compounds commonly added to personal care products. The compounds of interest include UV filters with the commercial name Eusolex (homosalate, 4-methylbenzylidenecamphor, benzophenone-3, octocrylene, butylmethoxydibenzoylmethane, ethylhexyl methoxycinnamate) and two common anti-microbial agents, clorophene and triclosan. Water samples were filtered, acidified, and extracted by use of solid-phase extraction. Extracted compounds were then derivatised before analysis by gas chromatography–mass spectroscopy. By use of our method we obtained limits of detection of 13–266 ng L−1 for UV filters, and 10–186 ng L−1 for triclosan and clorophene. Recoveries were 82–98% for deionised water and 50–98% for natural water (seawater, pool water, lake water, and river water). Samples collected in Slovenia included seventeen recreational waters (seawater, pool water, lake water, and river water; August 2004) and four wastewaters (January 2005). The most abundant UV filter was benzophenone-3 (11–400 ng L−1). Of the two anti-microbial agents studied, trace amounts, only, of triclosan were present in the river Kolpa (68 ng L−1) and in an hospital effluent (122 ng L−1).  相似文献   

5.
By alternate use of two different extraction solvents, n-hexadecane and benzyl alcohol, a headspace-solvent microextraction (HSME)–GC–FID/MS method has been established for characterization of the volatile components of an orange juice beverage. The method avoids two disadvantages of conventional HSME—difficulty identifying components obscured by the solvent peak and inefficient extraction of some of the compounds if one solvent only is used. The optimum conditions (droplet volume, equilibration temperature and time, extraction time, and ionic strength) were determined by the factor-rotation method. The volatile components of the beverage were mainly terpenes, terpenols, fatty acids, and alcohols, for example limonene (114.71 mg L−1), phellandrene (4.50 mg L−1), terpineol (p-menth-1-en-8-ol; 3.12 mg L−1), α-pinene (0.33 mg L−1), n-hexadecanoic acid (0.28 mg L−1), and terpinol (0.13 mg L−1).  相似文献   

6.
As a part of a project aiming to assess the potential toxicological effects of contaminants in aquatic ecosystems, the objective of this work was to determine the occurrence of several selected endocrine-disrupting compounds in water and sediment and to estimate the estrogenicity of the water. The study consisted of four sampling campaigns at seven sampling points in the lower Llobregat catchment area (NE Spain). Water and sediment samples underwent chemical target analysis for 19 steroid estrogens and alkylphenols, which are known to be endocrine-disrupting compounds. In this study, the only estrogens detected in the water samples were estrone and estrone-sulfate, which were found at low levels (2–5 ng l−1). The alkylphenolic compound showing the highest concentrations was nonylphenol di-ether carboxylate (NP2EC), which was found at levels up to 30.62 μg l−1 in water samples and 535 ng g−1 in sediment samples. K d was determined for several alkylphenolic compounds and showed the expected trend of decreasing K d with increasing polarity. The concentrations of nonylphenol and octylphenol only exceeded the annual average of the European Union’s environmental quality standards (EQS) in one sampling point. However, the calculated estrogenic potential surpassed the expected effect concentration in several sampling points, indicating a potential risk. Therefore, we recommend that future EQS include short-chain alkylphenol ethoxylates and carboxylates.  相似文献   

7.
In recent years, bamboo charcoal, a new kind of material with special microporous and biological characteristics, has attracted great attention in many application fields. In this paper, the potential of bamboo charcoal to act as a solid-phase extraction (SPE) adsorbent for the enrichment of the environmental pollutant perfluorooctanoic acid, which is one of the newest types of persistent organic pollutants in the environment, has been investigated. Important factors that may influence the enrichment efficiency—such as the eluent and its volume, the flow rate of the sample, the pH of the sample and the sample volume—were investigated and optimized in detail. Under the optimum conditions, the limit of detection for PFOA was 0.2 ng L−1. The experimental results indicated that this approach gives good linearity (R 2 = 0.9995) over the range 1–1000 ng L−1 and good reproducibility, with a relative standard deviation of 4.0% (n = 5). The proposed method has been applied to the analysis of real water samples, and satisfactory results were obtained. The average spiked recoveries were in the range 79.5∼118.3 %. All of the results indicate that the proposed method could be used for the determination of PFOA at ultratrace levels in water samples.  相似文献   

8.
Derivative of 8-hydroxyquinoline i.e. Clioquinol is well known for its antibiotic properties, drug design and coordinating ability towards metal ion such as Copper(II). The structure of mixed ligand complexes has been investigated using spectral, elemental and thermal analysis. In vitro anti microbial activity against four bacterial species were performed i.e. Escherichia coli, Pseudomonas aeruginosa, Serratia marcescens, Bacillus substilis and found that synthesized complexes (15–37 mm) were found to be significant potent compared to standard drugs (clioquinol i.e. 10–26 mm), parental ligands and metal salts employed for complexation. The kinetic parameters such as order of reaction (n = 0.96–1.49), and the energy of activation (E a = 3.065–142.9 kJ mol−1), have been calculated using Freeman–Carroll method. The range found for the pre-exponential factor (A), the activation entropy (S* = −91.03 to−102.6 JK−1 mol−1), the activation enthalpy (H* = 0.380–135.15 kJ mol−1), and the free energy (G* = 33.52–222.4 kJ mol−1) of activation reveals that the complexes are more stable. Order of stability of complexes were found to be [Cu(A4)(CQ)OH] · 4H2O > [Cu(A3)(CQ)OH] · 5H2O > [Cu(A1)(CQ)OH] · H2O > [Cu(A2)(CQ)OH] · 3H2O  相似文献   

9.
Perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA) are the most notable members of an emerging class of persistent organic pollutants (POPs), perfluorochemicals (PFCs). A method for the determination of PFOS and PFOA in water samples was developed and validated in this study. Water samples collected from river and industrial effluent at Guangzhou, one of the most industrialized regions in China, were analyzed by solid-phase extraction (SPE) followed by high-performance liquid chromatography (HPLC) negative electrospray ionization (ESI) mass spectrometry. Operational parameters of the ion trap mass spectrometer were optimized to improve sensitivity and selectivity of this method. The limits of quantitation and recoveries were 2.0 ng L− 1 and 75% for PFOA and 0.50 ng L− 1 and 88% for PFOS, respectively. In river water samples, 2.3-33 ng L− 1 of PFOS and < 2.0-11 ng L− 1 of PFPA were detected. And sewage effluents contained considerably higher concentrations of PFOS and PFOA.  相似文献   

10.
A sensitive and simple analytical method has been developed for determination of Sb(III), Sb(V), Se(IV), Se(VI), Te(IV), Te(VI), and Bi(III) in garlic samples by using hydride-generation–atomic-fluorescence spectrometry (HG–AFS). The method is based on a single extraction of the inorganic species by sonication at room temperature with 1 mol L−1 H2SO4 and washing of the solid phase with 0.1% (w/v) EDTA, followed by measurement of the corresponding hydrides generated under two different experimental conditions directly and after a pre-reduction step. The limit of detection of the method was 0.7 ng g−1 for Sb(III), 1.0 ng g−1 for Sb(V), 1.3 ng g−1 for Se(IV), 1.0 ng g−1 for Se(VI), 1.1 ng g−1 for Te(IV), 0.5 ng g−1 for Te(VI), and 0.9 ng g−1 for Bi(III), in all cases expressed in terms of sample dry weight.  相似文献   

11.
Liquid chromatography with electrospray mass spectrometry (LC–ESI-MS) instrumentation equipped with a single quadrupole mass filter has been used to determine several benzoylphenylurea insecticides (diflubenzuron, triflumuron, hexaflumuron, lufenuron and flufenoxuron). Chromatographic and MS parameters were optimised to obtain the best sensitivity and selectivity for all pesticides. Solid-phase extraction (SPE) using C18 cartridges was applied for preconcentration of pesticide trace levels in river water samples. Recoveries of benzoylphenylurea pesticides from spiked river water (0.01 and 0.025 μg L−1) were between 73 and 110% and detection limits were between 3.5 and 7.5 ng L−1. The applicability of the method to the determination of benzoylphenylurea insecticides in spiked cucumber, green beans, tomatoes and aubergines was evaluated. Samples were extracted into dichloromethane without any clean-up step. The limits of detection ranged from 1.0 to 3.2 ng mL−1 (0.68 and 2.13 μg kg−1 in the vegetable samples). Mean recoveries ranged from 79 to 114% at spiking levels of 0.01 and 0.03 mg kg−1. The method was applied to determine traces of benzoylphenylureas in both river water and vegetable samples with precision values lower than 10%. Interferences due to the matrix effect were overcome using matrix-matched standards.  相似文献   

12.
The determination of perfluorooctanoic acid (PFOA) and perfluorooctanesulfonate (PFOS) in food and beverages sold in Turkey was carried out using liquid chromatography–tandem mass spectrometry (LC-MS/MS). A total of 123 samples of selected food and beverages such as fish, meat, offal, egg, cracker, chips, cake, chocolate, vegetable, milk and juice were examined. The highest PFOA concentrations were determined in cow meat (5.15 ng g?1), cow kidney (5.65 ng g?1), cow spleen (5.06 ng g?1) and chicken liver (5.02 ng g?1). The highest PFOS levels were found in horse mackerel (52.43 ng g?1), pike-perch (45.87 ng g?1), sardine (42.83 ng g?1) and black cod (41.33 ng g?1). Fish was found to be major source of the PFOS intake, while meat and offal were found to be major sources of the PFOA intake.  相似文献   

13.
Two alternatives for the rapid simultaneous quantification of six sulfonylurea herbicides and five of their main degradation products in natural water are proposed. For concentration, the compounds were extracted on a polystyrene–divinylbenzene solid phase under pH and elution conditions that suppressed any hydrolysis. The eluates were analysed by liquid chromatography coupled to electrospray tandem mass spectrometry within 20 min. The whole method was validated and shown to give no hydrolysis artefacts. The application of off-line and on-line SPE of sulfonylureas enabled the 0.1 μg L−1 and 1 ng L−1 LOQ levels to be reached, respectively. The on-line SPE–LC–MS–MS method allowed the accurate quantitation of all sulfonylureas and three degradation products at 0.1 μg L−1 or below in natural water, with an average repeatability of 8%.  相似文献   

14.
A fully automated method using direct immersion solid-phase microextraction (DI-SPME) and headspace on-fiber silylation for simultaneous determinations of exogenous endocrine-disrupting chemicals (EDCs) and endogenous steroid hormones in environmental aqueous and biological samples by gas chromatography–mass spectrometry (GC-MS) was developed and compared to a previously reported manual method. Three EDCs and five endocrine steroid hormones were selected to evaluate this method. The extraction and derivatization time, ion strength, pH, incubation temperature, sample volume, and extraction solvent were optimized. Satisfactory results in pure water were obtained in terms of linearity of calibration curve (R 2=0.9932–1.0000), dynamic range (3 orders of magnitude), precision (4–9% RSD), as well as LOD (0.001–0.124 μg L−1) and LOQ (0.004–0.413 μg L−1), respectively. These results were similar to those obtained using a manual method, and moreover, the precision was improved. This new automated method has been applied to the determinations of target compounds in real samples used in our previous study on a manual SPME method. Exogenous octylphenol (OP), technical grade nonylphenol (t-NP), and diethylstilbestrol (DES) were at 0.13, 5.03, and 0.02 μg L−1 in river water and 3.76, 13.25, and 0.10 μg L−1 in fish serum, respectively. Natural steroid hormones estrone (E1), 17β-estradiol (E2), and testosterone (T) were at 0.19, 0.11, and 6.22 μg L−1 in river water; and in female fish serum E1, E2, and pregnenolone (PREG) were at 1.37, 1.95, and 6.25 μg L−1, respectively. These results were confirmed by the manual method. The developed fully automated SPME and on-fiber silylation procedures showed satisfactory applications in environmental analysis and the performances show improved precision and a reduced analysis time compared to the manual method.  相似文献   

15.
A complete characterization of sewage sludge collected from five biological waste water treatment plants was done to determine physico-chemical parameters, heavy metals and alkylphenols, making special emphasis on sampling, homogenization, and sample pre-treatment. Ultrasonic extraction followed by gas chromatrography coupled with mass spectrometry was used to evaluate the effect of sample pre-treatment (untreated sample, freeze-drying, drying at 40 °C or drying at 100 °C) on the concentration of octylphenol (OP), nonylphenol (NP) and nonylphenol ethoxylates (NP1EO, NP2EO). Untreated samples and samples dried at 100 oC gave concentration levels up to 62% and 89% lower, respectively, than freeze-dried samples. In 50% of cases, freeze-dried samples led to significantly higher concentrations than those obtained by drying at 40 °C. Thus, freeze-drying is the recommended sample pre-treatment to prevent possible losses of OP, NP, and NP1EO. Using this methodology, concentrations detected were from 3.2 to 199 mg kg−1 being NP followed by NP1EO found in highest concentration. The total concentration of NP and NP1EO exceeded the limit of 50 mg kg−1 proposed by the draft European directive on sewage sludge in three out of five samples studied. Contrarily, heavy metals were below the legislated values.  相似文献   

16.
A new Schiff-base ligand [N, N′, N″-Tri- (2,4-dihydroxyacetophenone) – triaminotriethylamine (TDATA)] with a tripodal structure was synthesized. Its fluorescence intensity with the europium(III) complex was increased about 178-fold in the presence of sodium acetate (NaAc) and about 126-fold in the presence of sodium phosphate (Na3PO4) solution. After adding the organic solvent dimethylsulfoxide (DMSO) to the above system, which leads to Eu3+ the fluorescence was further enhanced about 12-fold. Spectrofluorimetric determination of trace amounts of Eu3+ based on the phenomenon was performed. The excitation and emission wavelength is 365 nm and 615 nm, respectively. Under optimum conditions, the fluorescence intensities vary linearly with the concentration of Eu3+ in the range of 4.9 × 10−12–3.2 × 10−6 mol · L−1 with a detection limit of 4.5 × 10−12 mol · L−1 (for the TDATA-NaAc-DMSO system) or 6.2 × 10−11–8.6 × 10−6 mol · L−1 with a detection limit of 6.0 × 10−11 mol · L−1 (for the TDATA-Na3PO4-DMSO system). Interferences of some rare earth metals and other inorganic ions are described. The method is a selective, sensitive, rapid and simple analytical procedure for the determination of europium(III) in a high purity yttrium oxide and synthetic sample. The mechanism for the fluorescence enhancement is also discussed.  相似文献   

17.
The electrochemical behavior of the ofloxacin–copper complex, Cu(II)L2, at a mercury electrode, and the interaction of DNA with the complex have been investigated. The experiments indicate that the electrode reaction of Cu(II)L2 is an irreversible surface electrochemical reaction and that the reactant is of adsorbed character. In the presence of DNA, the formation of the electrochemically non-active complexes Cu(II)L2-DNA, results in the decrease of the peak current of Cu(II)L2. Based on the electrochemical behavior of the Cu(II)L2 with DNA, binding by electrostatic interaction is suggested and a new method for determining nucleic acid is proposed. Under the optimum conditions, the decrease of the peak current is in proportional to the concentration of nucleic acids in the range from 3 × 10−8 to 3 × 10−6 g · mL−1 for calf thymus DNA, from 1.6 × 10−8 to 9.0 × 10−7 g · mL−1 for fish sperm DNA, and from 3.3 × 10−8 to 5.5 × 10−7 g · mL−1 for yeast RNA. The detection limits are 3.3 × 10−9, 6.7 × 10−9 and 8.0 × 10−9 g · mL−1, respectively. The method exhibits good recovery and high sensitivity in synthetic samples and in real samples.  相似文献   

18.
A rapid, sensitive, and accurate high-performance liquid-chromatographic–mass spectrometric (HPLC–MS) method, with estazolam as internal standard, has been developed and validated for determination of aripiprazole in human plasma. After liquid–liquid extraction the compound was analyzed by HPLC on a C18 column, with acetonitrile—30 mm ammonium acetate containing 0.1% formic acid, 58:42 (v/v), as mobile phase, coupled with electrospray ionization mass spectrometry (ESI-MS). The protonated analyte was quantified by selected-ion recording (SIR) with a quadrupole mass spectrometer in positive-ion mode. Calibration plots were linear over the concentration range 19.9–1119.6 ng mL−1. Intra-day and inter-day precision (CV%) and accuracy (RE%) for quality-control samples (37.3, 124.4, and 622.0 ng mL−1) ranged between 2.5 and 9.0% and between 1.3 and 3.5%, respectively. Extraction recovery of aripiprazole from plasma was in the range 75.8–84.1%. The method enables rapid, sensitive, precise, and accurate measurement of the concentration of aripiprazole in human plasma.  相似文献   

19.
A novel method employing high-performance cation chromatography in combination with inductively coupled plasma dynamic reaction cell mass spectrometry (ICP–DRC–MS) for the simultaneous determination of the herbicide glyphosate (N-phosphonomethylglycine) and its main metabolite aminomethyl phosphonic acid (AMPA) is presented. P was measured as 31P16O+ using oxygen as reaction gas. For monitoring the stringent target value of 0.1 μg L−1 for glyphosate, applicable for drinking and surface water within the EU, a two-step enrichment procedure employing Chelex 100 and AG1-X8 resins was applied prior to HPIC–ICP–MS analysis. The presented approach was validated for surface water, revealing concentrations of 0.67 μg L−1 glyphosate and 2.8 μg L−1 AMPA in selected Austrian river water samples. Moreover, investigations at three waste water-treatment plants showed that elimination of the compounds at the present concentration levels was not straightforward. On the contrary, all investigated plant effluents showed significant amounts of both compounds. Concentration levels ranged from 0.5–2 μg L−1 and 4–14 μg L−1 for glyphosate and AMPA, respectively.  相似文献   

20.
A rapid and simple high performance liquid chromatographic method coupled with tandem mass spectrometry (LC–MS–MS) via electrospray ionization (ESI) has been developed and validated to separate and simultaneously quantify sodium ferulate (SF), salicylic acid (SA), cinnarizine (CIN) and vitamin B1 (VB1) in human plasma. Gemfibrozil (GEM) was used as the internal standard (IS) for SF and SA, whereas lomerizine (LOM) was used as the IS for CIN and VB1. The plasma samples were prepared by one-step protein precipitation followed by an isocratic elution with 10 mM ammonium acetate buffer (pH = 5.0): acetonitrile (35:65, v/v,) on an Agilent Zorbax SB-CN column (150 mm × 2.0 mm ID, 5 μm). The precursor and product ions of these drugs were monitored on a triple quadrupole mass spectrometer, operating in the selected reaction monitoring mode (SRM) with polarity switch, in the negative-ion mode for SF, SA and GEM, in the positive-ion mode for CIN, VB1 and LOM. The method was validated over the concentration range of 1.5–1,000 ng mL−1 for SF, 20–5,000 ng mL−1 for SA, 2–500 ng mL−1 for CIN, 1–30 ng mL−1 for VB1. The intra- and inter-batch precisions were less than 15% of the relative standard deviation. The recoveries for analytes and IS achieved from spiked plasma samples were consistent and reproducible. The validated LC–MS–MS method has been successfully applied to the pharmacokinetic study of sodium ferulate and aspirin capsule in healthy volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号