首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
An expeditious method for the determination of triclosan (TCS) and methyl triclosan (MTCS) in sludge and sediment samples is presented. Extraction and cleanup steps were integrated in the same process using matrix solid-phase dispersion as sample preparation technique. Effects of different variables on the efficiency and the selectivity of the sample preparation process are discussed. Under final working conditions, samples (0.5 g) were dispersed with diatomaceous earth (1 g) and transferred to a polypropylene syringe containing 2 g of silica impregnated with sulphuric acid (15%, w:w). Analytes were recovered with 10 mL of dichloromethane. After solvent exchange to ethyl acetate, TCS was converted into the tert-butyldimethylsilyl derivative, and the extract was analysed by gas chromatography-mass spectrometry, without any additional cleanup. Obtained recoveries, for sludge and sediment samples spiked at different concentration levels, ranged from 86% to 113%, with associated standard deviations between 2 and 13%. Limits of quantification of the global method were 6 and 7 ng g−1 for MTCS and TCS, respectively. Both compounds were detected in all the processed sludge samples with maximum concentrations of 191 ng g−1 (MTCS) and 2,640 ng g−1 (TCS). The parent bactericide was also found in some sediment samples at concentrations up to 200 ng g−1.  相似文献   

2.
A sensitive method has been developed and validated for the determination of diverse groups of pharmaceuticals, steroid hormones, and hormone-like personal care products in sewage sludge. Samples were extracted by ultrasonic-assisted extraction followed by solid-phase extraction cleanup. For determination of estrogens and hormone-like phenolic compounds, sample extracts were further derivatized with dansyl chloride and purified with silica gel column chromatography to improve the analytical sensitivity. The chemicals were determined by ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) in multiple-reaction monitoring mode. Recoveries ranged mostly from 63% to 119% with relative standard deviations within 15%. Method quantification limits were 0.1–3 ng g−1 dry weight (dw) for sewage sludge. The method was applied to a preliminary investigation of pharmaceuticals and personal care products (PPCPs) in sewage sludge and sediment in the Pearl River Delta, South China. Triclosan, triclocarban, 2-phenylphenol, bisphenol A, and parabens were ubiquitously detected at 3.6–5088.2 ng g−1 dw in sludge and 0.29–113.1 ng g−1 dw in sediment samples, respectively. Estrone, carbamazepine, metoprolol, and propranolol were also frequently quantified in the sludge and sediment samples. The dewatering process caused no significant losses of these PPCPs in sewage sludge.  相似文献   

3.
A survey of contamination of surface and drinking waters around Lake Maggiore in Northern Italy with polar anthropogenic environmental pollutants has been conducted. The target analytes were polar herbicides, pharmaceuticals (including antibiotics), steroid estrogens, perfluorooctanesulfonate (PFOS), perfluoroalkyl carboxylates (including perfluorooctanoate PFOA), nonylphenol and its carboxylates and ethoxylates (NPEO surfactants), and triclosan, a bactericide used in personal-care products. Analysis of water samples was performed by solid-phase extraction (SPE) then liquid chromatography–triple-quadrupole (tandem) mass spectrometry (LC–MS–MS). By extraction of 1-L water samples and concentration of the extract to 100 μL, method detection limits (MDLs) as low as 0.05–0.1 ng L−1 were achieved for most compounds. Lake-water samples from seven different locations in the Southern part of Lake Maggiore and eleven samples from different tributary rivers and creeks were investigated. Rain water was also analyzed to investigate atmospheric input of the contaminants. Compounds regularly detected at very low concentrations in the lake water included: caffeine (max. concentration 124 ng L−1), the herbicides terbutylazine (7 ng L−1), atrazine (5 ng L−1), simazine (16 ng L−1), diuron (11 ng L−1), and atrazine-desethyl (11 ng L−1), the pharmaceuticals carbamazepine (9 ng L−1), sulfamethoxazole (10 ng L−1), gemfibrozil (1.7 ng L−1), and benzafibrate (1.2 ng L−1), the surfactant metabolite nonylphenol (15 ng L−1), its carboxylates (NPE1C 120 ng L−1, NPE2C 7 ng L−1, NPE3C 15 ng L−1) and ethoxylates (NPE n Os, n = 3-17; 300 ng L−1), perfluorinated surfactants (PFOS 9 ng L−1, PFOA 3 ng L−1), and estrone (0.4 ng L−1). Levels of these compounds in drinking water produced from Lake Maggiore were almost identical with those found in the lake itself, revealing the poor performance of sand filtration and chlorination applied by the local waterworks.  相似文献   

4.
Robust instrumental analytical chemistry and the subsequent development of improved analytical methodologies and extraction procedures have enabled the detection at environmental levels of new emerging contaminants, for example pharmaceuticals. The objective of this study was to explore the potential of liquid chromatography–tandem quadrupole-linear ion trap (LC–QqLIT MS) for quantitative determination of nine sulfonamides (SAs) and one acetylated metabolite in surface water from the Llobregat River and one of its main tributaries, the Anoia River, in Catalonia (Spain). A total of 21 samples were taken in three sampling campaigns. Recoveries ranging from 26% to 123% were calculated for the SAs studied, and method limits of detection (MLODs) achieved were in the range 0.05–0.2 ng L−1. Through the different campaigns, concentrations ranged from 0.74 ng L−1 (sulfamethizole) to 2,482 ng L−1 (sulfamethazine) in the Llobregat River, and from 0.27 ng L−1 (sulfamethizole) to 168 ng L−1 (sulfamethoxazole) in the Anoia River. Sulfamethoxazole and sulfapyridine were the two SAs most frequently detected (80% and 71% respectively). N 4-acetylsulfamethazine was detected in both rivers, but with different frequencies (4% of the samples from the Anoia River and 43% of those from the Llobregat River). Information-dependent acquisition (IDA) experiments were also developed in order to obtain enhanced product-ion spectra in surface water samples.  相似文献   

5.
Continuous disposal of endocrine-disrupting compounds (EDCs) into the environment can lead to serious human health problems and can affect plants and aquatic organisms. The determination of EDCs in water has become an increasingly important activity due to our increased knowledge about their toxicities, even at low concentration. The EDCs in water samples from the reclaimed water plant of Tianjin, northern China, were identified by gas chromatography (GC)–mass spectrometry (MS). Important and contrasting EDCs including estrone (E1), 17β-estradiol (E2), 17α-ethynylestradiol (EE2), 4-tert-octylphenol (OP), 4-nonylphenol (NP), bisphenol A (BPA), di-n-butyl phthalate (DnBP), diisobutyl phthalate (DIBP), and di(2-ethylhexyl)phthalate (DEHP) were selected as the target compounds. Concentrations of steroid hormones, alkylphenolic compounds and phthalates ranged from below the limit of detection (LOD) to 8.1 ng L−1, from <LOD to 14.2 ng L−1, and from 1.00 μg L−1 to 23.8 μg L−1, respectively. The average removal efficiencies for target EDCs varied from 30% to 82%. These results indicate that environmental endocrine disrupting compounds are not completely removed during reclaimed water treatment and may be carried over into the general aquatic environment.  相似文献   

6.
The performance of the dispersive liquid–liquid microextraction (DLLME) technique for the determination of eight UV filters and a structurally related personal care species, benzyl salicylate (BzS), in environmental water samples is evaluated. After extraction, analytes were determined by gas chromatography combined with mass spectrometry detection (GC-MS). Parameters potentially affecting the performance of the sample preparation method (sample pH, ionic strength, type and volume of dispersant and extractant solvents) were systematically investigated using both multi- and univariant optimization strategies. Under final working conditions, analytes were extracted from 10 mL water samples by addition of 1 mL of acetone (dispersant) containing 60 μL of chlorobenzene (extractant), without modifying either the pH or the ionic strength of the sample. Limits of quantification (LOQs) between 2 and 14 ng L−1, inter-day variability (evaluated with relative standard deviations, RSDs) from 9% to 14% and good linearity up to concentrations of 10,000 ng L−1 were obtained. Moreover, the efficiency of the extraction was scarcely affected by the type of water sample. With the only exception of 2-ethylhexyl-p-dimethylaminobenzoate (EHPABA), compounds were found in environmental water samples at concentrations between 6 ± 1 ng L−1 and 26 ± 2 ng mL−1.  相似文献   

7.
The present work describes the development and validation of an analytical method based on liquid chromatography (LC), coupled with tandem mass spectrometry (MS/MS) that allows the determination and confirmation of several endocrine-disrupting chemicals (EDCs) in honey. The EDCs studied were nine phenols of different nature: chlorophenols (2,4-dichlorophenol, 2,4,5-trichlorophenol, and pentachlorophenol), alkylphenols (4-tert-butylphenol, 4-tert-octylphenol, and 4-n-octylphenol) bisphenols (bisphenol-A and bisphenol-F), and 4-tert-butylbenzoic acid. The method incorporates a restricted-access material (RAM), coupled on-line to the LC-MS/MS system, which allows direct injection of the matrix into the RAM-LC-MS/MS system. The optimized method developed, RAM-LC-MS/MS, was applied to fortified honey samples, affording detection limits in the 0.6–7.2 ng g−1 range, calculated for a signal-to-noise ratio of 3. In addition, the method was validated as a quantitative confirmatory method according to European Union Decision 2002/657/EC. The validation criteria evaluated were linearity, repeatability, reproducibility, recovery, decision limits, detection capabilities, specificity, and ruggedness. Repeatability and within-laboratory reproducibility were evaluated at two concentration levels, being ±11% or below at 20 ng g−1. The decision limits (CCα) and detection capabilities (CCβ) were in the 1.7–12.6 and 2.8–21.6 ng g−1 range, respectively.  相似文献   

8.
Stir-bar-sorptive extraction (SBSE) with liquid desorption (LD) and ultra-high-performance liquid chromatography–electrospray ionization triple-quadrupole tandem mass spectrometry (UHPLC–(ESI)MS–MS) were used for analysis of six personal care products in environmental water: four UV filters (2,2-dihydroxy-4-methoxybenzophenone, benzophenone-3, octocrylene, and octyldimethyl-p-aminobenzoic acid) and two antimicrobial agents (triclocarban and triclosan). Experimental conditions that affect SBSE-LD sorption efficiency (extraction time and temperature, sample pH, and ionic strength) and desorption efficiency (solvent, temperature, and time) were optimized. The method proved to be sensitive—a 50-mL sample was used to determine these compounds in environmental waters at trace levels. The detection limits of the analytical method were 2.5 ng L−1 for river water and 5–10 ng L−1 for effluent and influent sewage water. In river waters, benzophenone-3 was found at levels from 6 ng L−1 to 28 ng L−1 and triclosan at levels <LOQ. Benzophenone-3 was found between 75 and 127 ng L−1 in influent sewage, whereas concentrations of benzophenone-3 and triclosan were commonly below 25 ng L−1 in effluent sewage.  相似文献   

9.
This article presents an analytical method based on solid-phase extraction (SPE) and gas chromatography coupled with mass spectrometry for the simultaneous determination of the most frequently used acidic pharmaceutical residues, ibuprofen, diclofenac, naproxen and ketoprofen (KFN), and phenolic endocrine disruptors, bisphenol (BPA), triclosan (TCS), nonylphenol, nonylphenol monoethoxylate and nonylphenol diethoxylate, in wastewater and sewage sludge samples. In the first phase of the study, each compound has been characterized individually and afterwards in mixture as a trimethylsilyl derivative in order to identify the characteristic ions (m/z ratio) constituting the mass spectrum and to choose the ions for quantification and confirmation. Subsequently, derivatization was evaluated by testing different variables such as the volume of the derivatization solvent bis(trimethylsilyl)trifluoroacetamide and the effect of each catalyst, pyridine and 1% trimethyl chlorosilane, in the derivatized solution. For the analysis of wastewater samples, two commercial SPE cartridges, C18 and Oasis HLB, were compared for their extraction efficiency of the target compounds. The key parameter of extraction procedure included the effect of pH (2.5, 5.3 and 7) of the loading solution. For solid samples, parameters such as the extracted biomass, the volume of the extraction organic solvent and the effect of matrix interferences in chromatographic analysis were evaluated. By using C18 cartridges as purification procedure and ultrasound sonication, satisfactory mean relative recoveries with BPA-d16 and meclofenamic acid as surrogates were obtained ranging from 91% to 117% for wastewater and 84% to 107% for sewage sludge samples. Nine-point calibration of the standard mixture was performed by linear regression analysis with a correlation coefficient >0.99 for all the tested compounds. Limits of detection for the developed methods were established between 0.3 (KFN) and 14.8 (BPA) ng L−1, and 15.0 (TCS) and 32.9 (BPA) ng g−1 for wastewater and sewage sludge, respectively. Application to real samples of the wastewater treatment plant in Athens, the capital of Greece, demonstrated the presence of all tested compounds in most of the samples.  相似文献   

10.
The present study describes an automated methodology based on a liquid chromatography-electrospray, tandem mass spectrometry method combined with online solid phase extraction (online SPE-LC-ESI-MS/MS) for the simultaneous analysis of 16 sulfonamides (SAs) and five of their acetylated metabolites in groundwater. The evaluation of the degree of SA pollution in groundwater was made through the analysis of a total of 39 samples taken in seven groundwater bodies of Catalonia (Spain). Recovery values obtained ranged from 34.3% (N 4-acetylsulfadiazine) to 134.4% (sulfabenzamide). The method limits of detection for all the analytes were 0.09–11 ng L−1. Sulfamethoxazole was the SA detected more frequently (56.4% of the samples), with an average concentration of 2.3 ng L−1, followed by sulfadimethoxine, present in 54% of the samples with an average concentration of 0.2 ng L−1. It should be highlighted that the acetylated metabolites were ubiquitous in the different samples, with frequencies of detection up to 36% and maximum concentrations of 18 ng L−1 (N 4-acetylsulfamerazine).  相似文献   

11.
It is observed that Ag(I) catalyzes the rate of substitution of phenylhydrazine (PhNHNH2) into hexacyanoferrate(II), producing a cherry red colored complex, [Fe(CN)5PhNHNH2]3−. The reaction was monitored at 488 nm leading to the formation of the complex under the conditions: [Fe(CN)6]4− (5.0 × 10−3 mol dm−3), PhNHNH2 (2.0 × 10−3 mol dm−3), temperature (25 ± 0.1 °C), pH (2.8 ± 0.02), and ionic strength, I (0.02 mol dm−3), (KNO3). Under optimum conditions, absorbance at fixed times (A t ) is linearly related to Ag(I) in the concentration range 10.79–97.08 ng cm−3, in the presence of several diverse ions. The highest percentage error and relative standard deviations in the entire range of Ag(I) determination are found to be 2.5% and 0.16, with a detection limit of 8.75 ng cm−3 of silver(I). The experimental accuracies expressed in terms of percentage recoveries are in the range of 97.87–102.50. The method was successfully applied for the determination of Ag(I) in a few synthetic samples and found to be in good agreement with those obtained from atomic absorption spectrophotometry (AAS). The validity of the proposed method has also been tested for Ag(I) determination in spiked drinking water samples. The present catalytic kinetic method (CKM) is highly sensitive, selective, reproducible, and inexpensive. A review of recently published catalytic spectrophotometric methods for determination of Ag(I) has also been presented for comparison.  相似文献   

12.
An indirect competitive enzyme-linked immunosorbent assay (ELISA) was developed in plate to detect three sulfonamide residues (sulfamerazine (SMR), sulfadimetoxine (SDM), and sulfadiazine (SDZ)) in gilthead sea bream (Sparus aurata) samples. Different extraction methodologies—using methanol/water 1:1 (v/v) + ethylene diamine tetraacetic acid (EDTA) 0.5% (m/v), acetonitrile, phosphate-buffered saline (PBS) 10 mmol L−1 pH 7 and acetate buffer 100 mmol L−1 pH 5—and cleanup steps, based on solid-phase extraction (C18, SCX, Si) or liquid extraction with hexane, were assayed. As optimum, a fast and simple method using acetonitrile was selected to extract the sulfonamide residues from the edible muscle of fish. Due to matrix effects, a standard addition calibration curve in fish extract is necessary for quantification purposes. Sulfonamide-free samples were spiked at different concentration levels (between 30 and 90 ng g−1, 5–15 ng mL−1 in plate) and average recoveries (n = 8), ranging from 71% to 95%, 65% to 79%, and 72% to 95%, were obtained for SMR, SDM, and SDZ, respectively. The assay detection limits for these antibiotics were lower than 100 μg kg−1 (maximum residue level established by the European Union). The accuracy was evaluated by spiking blank fish extracts at different concentrations (10–40 ng mL−1, 5–20 ng mL−1 in plate), and the relative errors ranged between ±20%. Finally, in order to confirm the utility of the developed ELISA as a screening methodology, fish samples from different supermarkets were analyzed, and results were compared with those obtained by a validated high-performance liquid chromatography (HPLC) method. The correlation between the results obtained by both ELISA and HPLC methods is satisfactory.   相似文献   

13.
A novel method for the determination of five sulfonylurea herbicides in soil was developed by a dispersive solid-phase extraction (DSPE) clean-up followed by dispersive liquid–liquid microextraction (DLLME), prior to sweeping micellar electrokinetic chromatography (MEKC). In the DSPE-DLLME, 10 g of soil sample was first extracted with 10 mL of acetonitrile containing 5% formic acid (pH 3.0). The extract was then cleaned-up by a DSPE with C18 as sorbent. A 1 mL aliquot of the resulting extract was then added into a centrifuge tube containing 5 mL of water adjusted to pH 2.0 and 60.0 μL chlorobenzene (as extraction solvent) for DLLME procedure. Then, the organic sample extraction solution was evaporated to dryness, and reconstituted with 20.0 μL of 1.0 mmol L−1 Na2HPO4 (pH 10.0) for sweeping-MEKC analysis after DLLME. Under optimized conditions, the method provided as high as 3,000- to 5,000-fold enrichments factors. The linearity of the method was in the range of 3.3–200 ng g−1 for chlorimuron ethyl and bensulfuron methyl, and in the range of 1.7–200 ng g−1 for tribenuron methyl, chlorsulfuron and metsulfuron methyl, with the correlation coefficients (r) ranging from 0.9965 to 0.9983, respectively. The limits of detection (LODs) ranged from 0.5 to 1.0 ng g−1. The intraday relative standard deviations (RSDs, n = 5) were below 5.3% and interday RSDs (n = 15) within 6.8%. The recoveries of the method for the five sulfonylureas from soil samples at spiking levels of 5.0, 20.0, and 100.0 ng g−1 were 76.0–93.5%, respectively. The developed method has been successfully applied to the analysis of the target sulfonylurea herbicide residues in soil samples with a satisfactory result.  相似文献   

14.
A complete characterization of sewage sludge collected from five biological waste water treatment plants was done to determine physico-chemical parameters, heavy metals and alkylphenols, making special emphasis on sampling, homogenization, and sample pre-treatment. Ultrasonic extraction followed by gas chromatrography coupled with mass spectrometry was used to evaluate the effect of sample pre-treatment (untreated sample, freeze-drying, drying at 40 °C or drying at 100 °C) on the concentration of octylphenol (OP), nonylphenol (NP) and nonylphenol ethoxylates (NP1EO, NP2EO). Untreated samples and samples dried at 100 oC gave concentration levels up to 62% and 89% lower, respectively, than freeze-dried samples. In 50% of cases, freeze-dried samples led to significantly higher concentrations than those obtained by drying at 40 °C. Thus, freeze-drying is the recommended sample pre-treatment to prevent possible losses of OP, NP, and NP1EO. Using this methodology, concentrations detected were from 3.2 to 199 mg kg−1 being NP followed by NP1EO found in highest concentration. The total concentration of NP and NP1EO exceeded the limit of 50 mg kg−1 proposed by the draft European directive on sewage sludge in three out of five samples studied. Contrarily, heavy metals were below the legislated values.  相似文献   

15.
A liquid chromatographic–mass spectrometric (LC–MS) method has been developed and validated for simultaneous determination of dehydroevodiamine and limonin from Evodia rutaecarpa in rat plasma. After addition of the internal standard, domperidone, plasma samples were extracted by liquid–liquid extraction with ethyl acetate and separated on an Apollo C18 column (250 mm × 4.6 mm, 5 μm), with methanol–0.01% formic acid water (60:40, v/v) as mobile phase, within a runtime of 12.0 min. The analytes were detected without interference in the selected ion monitoring (SIM) mode with positive electrospray ionization. The linear range was 1.0–500 ng mL−1 for dehydroevodiamine and 2.0–1,000 ng mL−1 for limonin, with lower limits of quantitation of 1.0 and 2.0 ng mL−1, respectively. Intra-day and inter-day precision were within 6.0% and 10.9%, respectively, for both analytes, and the accuracy (relative error, RE, %) was less than 4.8% and 6.5%, respectively. The validated method was successfully applied to a comparative pharmacokinetic study of dehydroevodiamine and limonin in rat plasma after oral administration of dehydroevodiamine, limonin, and an aqueous extract of Evodiae fructus. The results indicated there were obvious differences between the pharmacokinetic behavior after oral administration of an aqueous extract of Evodiae fructus compared with single substances.  相似文献   

16.
For safety assessments of geological repositories of nuclear waste, understanding of uranium (U) fate in estuarine areas is important because U chemical behavior in the areas is expected to be complex. Environmental transfer parameters such as sediment–water distribution coefficients (K d) and concentration ratios (CRs) for marine organisms are useful in mathematical models for the assessment. However, due to its low concentration in estuarine water, K d and CF data for U are scarce. Thus we studied a rapid method for separation and concentration of U from estuarine water samples using NOBIAS-CHELATE PA1 resin columns followed by inductively coupled plasma mass spectrometry (ICP-MS) for U measurement. Chemical recovery was about 100% at pH of 5.7 ± 0.1 from the water samples and alkali and alkaline earth metals were removed. The method was used to measure U concentrations in estuarine water samples collected at eight Japanese estuarine areas; they ranged from 0.1 to 3.8 μg L−1. We also measured U concentrations in sediment and marine organism samples by ICP-MS after acid digestion. Using these values, we observed K d (range: 39–284 L kg−1) and CRs (0.86–52 L kg−1 for macroalgae, 0.087–15 L kg−1 for crustaceans, and 0.52–93 L kg−1 for molluscs).  相似文献   

17.
In this study, a method for the determination of organic micro-pollutants, i.e. personal care products such as synthetic musk fragrances, household bactericides, organophosphate flame retardants and plasticizers, as well as phthalates in sludge, has been developed. This method is based on lyophilisation and accelerated solvent extraction followed by clean-up steps, i.e. solid phase extraction and size exclusion chromatography. The determination is performed by gas chromatography coupled to mass spectrometry. Stable isotope-labelled compounds such as musk xylene (MX D15), tri-n-butylphosphate (TnBP D27) and triphenylphosphate (TPP D15) were used as internal standards. Recovery rates were determined to be 36–114% (with typical relative standard deviation of 5% to 23%) for the target compounds. The limit of detection was 3–30 ng g−1, and the limit of quantification was 10–100 ng g−1 dry matter.  相似文献   

18.
A fully automated method using direct immersion solid-phase microextraction (DI-SPME) and headspace on-fiber silylation for simultaneous determinations of exogenous endocrine-disrupting chemicals (EDCs) and endogenous steroid hormones in environmental aqueous and biological samples by gas chromatography–mass spectrometry (GC-MS) was developed and compared to a previously reported manual method. Three EDCs and five endocrine steroid hormones were selected to evaluate this method. The extraction and derivatization time, ion strength, pH, incubation temperature, sample volume, and extraction solvent were optimized. Satisfactory results in pure water were obtained in terms of linearity of calibration curve (R 2=0.9932–1.0000), dynamic range (3 orders of magnitude), precision (4–9% RSD), as well as LOD (0.001–0.124 μg L−1) and LOQ (0.004–0.413 μg L−1), respectively. These results were similar to those obtained using a manual method, and moreover, the precision was improved. This new automated method has been applied to the determinations of target compounds in real samples used in our previous study on a manual SPME method. Exogenous octylphenol (OP), technical grade nonylphenol (t-NP), and diethylstilbestrol (DES) were at 0.13, 5.03, and 0.02 μg L−1 in river water and 3.76, 13.25, and 0.10 μg L−1 in fish serum, respectively. Natural steroid hormones estrone (E1), 17β-estradiol (E2), and testosterone (T) were at 0.19, 0.11, and 6.22 μg L−1 in river water; and in female fish serum E1, E2, and pregnenolone (PREG) were at 1.37, 1.95, and 6.25 μg L−1, respectively. These results were confirmed by the manual method. The developed fully automated SPME and on-fiber silylation procedures showed satisfactory applications in environmental analysis and the performances show improved precision and a reduced analysis time compared to the manual method.  相似文献   

19.
The combination of bar adsorptive micro-extraction using activated carbon (AC) and polystyrene–divinylbenzene copolymer (PS-DVB) sorbent phases, followed by liquid desorption and large-volume injection gas chromatography coupled to mass spectrometry, under selected ion monitoring mode acquisition, was developed for the first time to monitor pharmaceutical and personal care products (PPCPs) in environmental water matrices. Assays performed on 25 mL water samples spiked (100 ng L−1) with caffeine, gemfibrozil, triclosan, propranolol, carbamazepine and diazepam, selected as model compounds, yielded recoveries ranging from 74% to 99% under optimised experimental conditions (equilibrium time, 16 h (1,000 rpm); matrix characteristics: pH 5, 5% NaCl for AC phase; LD: methanol/acetonitrile (1:1), 45 min). The analytical performance showed good precision (RSD < 18%), convenient detection limits (5–20 ng L−1) and excellent linear dynamic range (20–800 ng L−1) with remarkable determination coefficients (r 2 > 0.99), where the PS-DVB sorbent phase showed a much better efficiency. By using the standard addition methodology, the application of the present analytical approach on tap, ground, sea, estuary and wastewater samples allowed very good performance at the trace level. The proposed method proved to be a suitable sorption-based micro-extraction alternative for the analysis of priority pollutants with medium-polar to polar characteristics, showing to be easy to implement, reliable, sensitive and requiring a low sample volume to monitor PPCPs in water matrices.  相似文献   

20.
A cost-effective and low solvent consumption method, based on the matrix solid-phase dispersion (MSPD) technique, for the determination of six benzotriazole UV absorbers in sediments is presented. Sieved samples (0.5 g) were first mixed in a mortar with a solid sorbent and then transferred to a polypropylene syringe containing a layer of clean-up co-sorbent. Analytes were eluted with a suitable solvent and further determined by gas chromatography with tandem mass spectrometry (GC-MS/MS). Under final conditions, diatomaceous earth and silica, deactivated to 10%, were used as inert dispersant and clean-up co-sorbent, respectively. Analytes were recovered using just 5 mL of dichloromethane, and this extract was concentrated and exchanged to 1 mL of isooctane. Further removal of co-extracted sulphur was achieved adding activated copper powder to final extracts, which were stored overnight, before injection in the GC-MS/MS system. The accuracy of the method was assessed with river and marine sediment samples showing different carbon contents and spiked at different concentrations in the range from 40 to 500 ng g−1. Recoveries varied between 78% and 110% with associated standard deviations below 14%. The limits of quantification of the method stayed between 3 and 15 ng g−1. Levels of target compounds in sediment samples ranged from not detected up to a maximum of 56 ng g−1 for Tinuvin 328.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号