首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Zhang Z  Rhind SM 《Talanta》2011,84(2):487-493
We describe a solid-phase extraction (SPE) method, followed by gas chromatography-mass spectrometry (GC-MS), for the simultaneous determination of polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) in sheep serum samples. The denaturation of serum proteins by formic acid, water-1-propanol and water-2-propanol were compared and optimized. Seven different solid-phase sorbents were tested and it was found that Strata-X cartridge (200 mg, 6 mL) gave the best recoveries (92-106%, SD < 6%, n = 3) for all the target analytes. The different extraction solvents (iso-hexane and dichloromethane), either alone or in combination, were used to extract these persistent organic compounds from spiked serum samples by SPE. Removal of co-extracted biogenic materials was achieved using adsorption chromatography with acid modified silica and activated silica. Iso-hexane was found to be the most appropriate solvent for clean-up providing good recoveries and clear chromatographic separation; its use is preferable to that of DCM because it is less environmentally toxic. The limits of detection (LOD) of the proposed method were 47-105 pg g−1 and 16-24 pg g−1 for the different PBDEs and PCBs studied, respectively. The developed method was linear over the range from 0.05 to 30 ng g−1, for all PBDEs except PBDE 183 (0.10-30 ng g−1), and from 0.02 to 30 ng g−1 for all tested PCB congeners. The established method was successfully applied to sheep serum samples from Scotland, UK, for the determination of the target PBDEs and PCBs.  相似文献   

2.
A one-step extraction and clean-up method using pressurized liquid extraction (PLE) (selective PLE) combined with gas chromatography-ion-trap tandem mass spectrometry (GC-ITMS-MS) was evaluated for the analysis of polybrominated diphenyl ethers (from tri- to hepta-PBDEs) at low concentrations in fish and shellfish samples. To this end, the performance of an on-line PLE extraction/clean-up method and of a classical Soxhlet extraction and clean-up method using a multi-layer modified silica column were compared. The two sample treatment methods provided similar results, although an important reduction in the sample treatment time (40 min per sample) was achieved using the selective PLE method. In addition, the suitability of the PLE combined with GC-ITMS-MS method was evaluated by comparing the results obtained in the analysis of fish samples with those obtained by gas chromatography-high resolution mass spectrometry (GC-HRMS). Good agreement between both techniques was obtained with differences between the mean values of less than 16%. The selective PLE method coupled to GC-ITMS-MS produced accurate results for PBDE determination with low limits of detection (1.0-16.8 pg g−1 wet weight) and quantification (3.1-51 pg g−1 wet weight) as well as good precision (RSD < 16%). This method has been applied to the analysis of PBDEs in fish and shellfish samples collected at fish markets in Catalonia (NE Spain).  相似文献   

3.
The applicability of two different MS ionisation modes (EI and ECNI) for the determination of PBDEs at low-trace levels in small-size (up to 1 mL) human samples was compared. The instrumental precision, expressed as R.S.D., obtained for both ionisation modes was similar and lower than 6% (repeatability) and 12% (intermediate precision) for all congeners investigated, except PBDE 209. The LODs obtained when using the ECNI-MS operation mode (6-507 fg) were lower than those found in EI-MS experiments (9 and 10,909 fg), mainly for those congeners with a high bromination degree, i.e., hepta- to deca-BDEs. The selectivity of the ECNI-MS method proposed in the present work was improved by using two ions of the [M−HxBry] cluster as both qualifier and quantifier ions. For the final validation of the methods, serum and breast milk samples from two different inter-laboratory exercises were analysed. A good agreement was found between the results obtained using the proposed methods and the results provided by the different inter-laboratory organisations, but only ECNI-MS provided the low-LODs necessary for the quantification of high brominated congeners (mainly, PBDEs 196, 197 and 209) at low concentration levels in small-size human samples. Finally, the ECNI-MS method was applied to real-life samples obtained from the Spanish population and the preliminary results obtained were in the same range as those found in other European and Asian regions and lower than the concentrations reported in USA populations.  相似文献   

4.
A multi-class, multi-residue method for the analysis of 13 novel flame retardants, 18 representative pesticides, 14 polychlorinated biphenyl (PCB) congeners, 16 polycyclic aromatic hydrocarbons (PAHs), and 7 polybrominated diphenyl ether (PBDE) congeners in catfish muscle was developed and evaluated using fast low pressure gas chromatography triple quadrupole tandem mass spectrometry (LP-GC/MS–MS). The method was based on a QuEChERS (quick, easy, cheap, effective, rugged, safe) extraction with acetonitrile and dispersive solid-phase extraction (d-SPE) clean-up with zirconium-based sorbent prior to LP-GC/MS–MS analysis. The developed method was evaluated at 4 spiking levels and further validated by analysis of NIST Standard Reference Materials (SRMs) 1974B and 1947. Sample preparation for a batch of 10 homogenized samples took about 1 h/analyst, and LP-GC/MS–MS analysis provided fast separation of multiple analytes within 9 min achieving high throughput. With the use of isotopically labeled internal standards, recoveries of all but one analyte were between 70 and 120% with relative standard deviations less than 20% (n = 5). The measured values for both SRMs agreed with certified/reference values (72–119% accuracy) for the majority of analytes. The detection limits were 0.1–0.5 ng g−1 for PCBs, 0.5–10 ng g−1 for PBDEs, 0.5–5 ng g−1 for select pesticides and PAHs and 1–10 ng g−1 for flame retardants. The developed method was successfully applied for analysis of catfish samples from the market.  相似文献   

5.
Polybrominated diphenyl ether (PBDE) congeners and components of the complex mixture toxaphene are stable in the environment and readily bioaccumulated into wildlife and human tissues. PBDEs are presently used in large quantities worldwide as flame retardants in textiles, furniture, computer equipment, and cables. Toxaphene is a complex mixture of chlorinated bornanes and bornenes that was the most heavily used pesticide in the United States until it was banned in 1982; however, some countries continue to use toxaphene. The National Institute of Standards and Technology has quantified PBDE congeners and toxaphene in several available Standard Reference Materials (SRMs) using methods of gas chromatography with electron impact mass spectrometry (GC-EI-MS) and GC negative chemical ionization (NCI) MS, respectively. SRM 1588a Organics in Cod Liver Oil and SRM 1945 Organics in Whale Blubber were examined for PBDE congeners 47, 99, 100, 153, and 154, total toxaphene, and toxaphene congeners 26, 50, and 62. SRM 1946 Lake Superior Fish Tissue was also examined for total toxaphene and toxaphene congeners. The sum of the PBDE congeners (mean, (1 SD) wet basis) for SRM 1945 was 150 ng g–1 (7 ng g–1). The concentration of PBDE 47 in SRM 1588a was 82.7 ng g–1 (2.8 ng g–1). Other PBDEs were detected in SRM 1588a but were not quantified due their low levels. The total toxaphene (wet mass basis) was 1,210 ng g–1 (127 ng g–1), 1,960 ng g–1 (133 ng g–1), and 3,980 ng g–1 (248 ng g–1) in SRMs 1945, 1946, and 1588a, respectively. The values for PBDEs and toxaphene determined in the SRMs, while not certified, indicate that the SRMs will be suitable control materials for PBDE and toxaphene analyses.  相似文献   

6.
Polychlorinated dibenzo-p-dioxins/furans (PCDD/Fs), polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) are important environmental contaminants. Their maximum legally allowable levels in food and environment are in the low pg g−1 range. Therefore some highly selective and sensitive analytical methods must be used to determine them. Prior to final determination by GC/MS the cleaned-up samples have to be split into some fractions in view of large differences in concentrations of various analytes and existence of numerous chromatographic co-elutions (which in any case cannot be fully avoided). The aim of this study was to: (i) develop a robust, time-saving analytical method to isolate, clean-up and fractionate PCBs, PBDEs and PCDD/Fs prior to their determination with gas chromatography/ion trap mass spectrometry; (ii) assess method performance using laboratory validation data and some certified reference materials; (iii) use the developed method to assess PCB/PBDE/PCDD/F levels in samples of commercially available food. A combination of alumina, florisil, modified silica gel and two carbon columns were used for sample cleanup and fractionation. Separate fractions containing dioxins/furans, PBDE, non-ortho, mono-ortho and di-/tri-/tetra-ortho PCBs were obtained. The method statistical parameters were compatible with 1883/2006 EC Regulation (80–120%, RSD below 15%). The method performance was successfully used to evaluation of some real life food samples.  相似文献   

7.
Ultrasound-assisted leaching-dispersive solid-phase extraction followed by dispersive liquid-liquid microextraction (USAL-DSPE-DLLME) technique has been developed as a new analytical approach for extracting, cleaning up and preconcentrating polybrominated diphenyl ethers (PBDEs) from sediment samples prior gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. In the first place, PBDEs were leached from sediment samples by using acetone. This extract was cleaned-up by DSPE using activated silica gel as sorbent material. After clean-up, PBDEs were preconcentrated by using DLLME technique. Thus, 1 mL acetone extract (disperser solvent) and 60 μL carbon tetrachloride (extraction solvent) were added to 5 mL ultrapure water and a DLLME technique was applied. Several variables that govern the proposed technique were studied and optimized. Under optimum conditions, the method detection limits (MDLs) of PBDEs calculated as three times the signal-to-noise ratio (S/N) were within the range 0.02-0.06 ng g−1. The relative standard deviations (RSDs) for five replicates were <9.8%. The calibration graphs were linear within the concentration range of 0.07-1000 ng g−1 for BDE-47, 0.09-1000 ng g−1 for BDE-100, 0.10-1000 ng g−1 for BDE-99 and 0.19-1000 ng g−1 for BDE-153 and the coefficients of estimation were ≥0.9991. Validation of the methodology was carried out by standard addition method at two concentration levels (0.25 and 1 ng g−1) and by comparing with a reference Soxhlet technique. Recovery values were ≥80%, which showed a satisfactory robustness of the analytical methodology for determination of low PBDEs concentration in sediment samples.  相似文献   

8.
In the present study, a novel analytical approach for the simultaneous determination of 27 brominated flame retardants (BFRs), namely polybrominated diphenyl ethers (PBDEs), isomers of hexabromocyclododecane (HBCD), tetrabromobisphenol A (TBBPA) and several novel BFRs (NBFRs), together with 18 perfluoroalkyl substances (PFASs) in indoor dust was developed and validated. To achieve integrated isolation of analytes from the sample and their fractionation, a miniaturized method based on matrix solid phase dispersion (MSPD) was employed. Principally, after mixing the dust (<0.1 g) with the Florisil®, the mixture was applied on the top of a sorbent (Florisil®) placed in glass column and then analytes were eluted using solvents with different polarities. For the identification/quantification of target compounds largely differing in polarity, complementary techniques represented by gas and liquid chromatography coupled to tandem mass spectrometry (GC–MS/MS and LC–MS/MS) were used. The results of validation experiments, which were performed on the SRM 2585 material (for PBDEs, HBCDs and TBBPA), were in accordance with the certified/reference values. For other analytes (NBFRs and PFASs), the analysis of an artificially contaminated blank dust sample was realized. The method recoveries for all target compounds ranged from 81 to 122% with relative standard deviations lower than 21%. The quantification limits were in the range of 1–25 ng g−1 for BFRs and 0.25–1 ng g−1 for PFASs. Finally, 18 samples (6 households × 3 sampling sites) were analyzed. The high variability between concentrations of PFASs and BFRs in the dust samples from various households as well as collecting sites in a respective house was observed. The total amounts of PFASs and BFRs were in the range of 1.58–236 ng g−1 (median 10.6 ng g−1) and 39.2–2320 ng g−1 (median 325 ng g−1), respectively. It was clearly shown that dust from the indoor environment might be a significant source of human exposure to various organohalogen pollutants.  相似文献   

9.
Polybrominated diphenyl ethers (PBDEs) are flame retardants, which due to their widespread use are frequently present as pollutants in the environment. In the EU Water Framework Directive (WFD) six PBDE congeners (BDE 28, BDE47, BDE 99, BDE 100, BDE 153 and BDE 154) are listed as priority substances. The uncertainty of the analytical method used for their determination in water samples at environmental quality standard (EQS) level (0.5 ng L−1 for the ΣPBDEs) should be equal or less than 50% and the limit of quantification (LOQ) for ΣPBDEs below 0.15 ng L−1. To meet these requirements, an analytical procedure for the determination of these six PBDEs in environmental water samples by gas chromatography–inductively coupled plasma mass spectrometry (GC–ICP-MS) was developed. The acidification of water samples to pH 2 maintained the stability of PBDEs for at least 20 days. The use of Tris–citrate buffer enabled efficient desorption of PBDEs from suspended particulate matter (SPM) and humic acids (HA), and their further quantitative solvent extraction into 2 mL of iso-octane. When 300 mL of water sample was used for analysis and the organic phase concentrated to 25 μL, the expanded uncertainty for determination of PBDEs at EQS level was found to be around 40% (a coverage factor for a confidence level of 95%, k = 2), and the LOQ for the ΣPBDEs 0.109 ng L−1. Finally, to demonstrate the applicability of the newly developed GC–ICP-MS procedure, PBDEs were determined in river and sea water samples.  相似文献   

10.
An organically modified silicate (ORMOSIL) SPME stationary phase molecularly imprinted with BDE-209 has been successfully fabricated by conventional sol-gel technique from phenyltrimethoxysilane and tetraethoxysilane. The thickness of the ORMOSIL-SPME stationary phase, on fused-silica optical fibres, was measured to be ca. 9.5 μm with a volume of ca. 0.12 μL. Rebinding assays and Scatchard analysis revealed that the imprinted ORMOSIL-SPME stationary phase possessed a binding affinity, KB, of 7.3 ± 1.7 × 1010 M−1 for BDE-209, with a receptor site density, Bmax, of 1.2 × 10−3 pmol per SPME device. Besides its molecular template, the ORMOSIL-SPME stationary phase also showed good affinity (log KB ≥ 9.5) for smaller BDE congeners commonly found in the natural environment. The density of receptor sites within the imprinted matrix for those smaller BDE congeners was even higher than that for BDE-209. This may be attributable to the binding site heterogeneity of the imprinting process that creates deformed binding sites that are suitable for the accommodation of the smaller BDE congeners. Compared to the commercially available polyacrylate and polydimethylsiloxane SPME stationary phases, the imprinted ORMOSIL-SPME devices showed much higher pre-concentration ability towards polybrominated diphenyl ethers (PBDEs), even in direct immersion sampling at room temperature. Coupled with GC-NCI-MS and GC-μECD, the imprinted ORMOSIL-SPME device was able to achieve detection sensitivity of 0.2-3.6 pg mL−1 and 1-8.8 pg mL−1, respectively, for commonly occurring BDE congeners, including medium to high molecular weight PBDEs. The imprinted ORMOSIL-SPME device has been successfully applied to monitor PBDE contents in municipal wastewaters.  相似文献   

11.
Josep Rubert  Jordi Mañes 《Talanta》2010,82(2):567-826
A method based on Matrix Solid-Phase Dispersion (MSPD) has been developed for the determination of 5 mycotoxins (ochratoxin A and aflatoxins B and G) in different cereals. Several dispersants, eluents and ratios were tested during the optimization of the process in order to obtain the best results. Finally, samples were blended with C18 and the mycotoxins were extracted with acetonitrile. Regarding to matrix effects, the results clearly demonstrated the necessity to use a matrix-matched calibration to validate the method. Analyses were performed by liquid chromatography-triple quadrupole-tandem mass spectrometry (LC-QqQ-MS/MS). The recoveries of the extraction process ranged from 64% to 91% with relative standard deviation lower than 19% in all cases, when samples were fortified at two different concentrations levels. Limits of detection ranged from 0.3 ng g−1 for aflatoxins to 0.8 ng g−1 for OTA and the limits of quantification ranged from 1 ng g−1 for aflatoxins to 2 ng g−1 for OTA, which were below the limits of mycotoxins set by European Union in the matrices evaluated. Application of the method to the analysis of several samples purchased in local supermarkets revealed aflatoxins and OTA levels.  相似文献   

12.
S. Losada  M.T. Galceran 《Talanta》2009,80(2):839-91
A fast and simple method for the analysis of polybrominated diphenyl ethers (PBDEs) in fish samples was developed using a one-step extraction and clean-up by means of pressurized liquid extraction (PLE) combined with gas chromatography-ion trap tandem mass spectrometry (GC-ITMS-MS). The selective PLE method provided to obtain ready-to-analyse extracts without any additional clean-up step, using a sorbent as fat retainer inside the PLE cell. Several PLE operating conditions, such as solvent type, extraction temperature and time, number of cycles and type of fat retainer, were studied. Using Florisil as fat retainer, maximum recoveries of PBDEs (83-108%) with minimum presence of matrix-interfering compounds were obtained using a mixture of n-hexane:dichloromethane 90:10 (v/v) as solvent, an extraction temperature of 100 °C and a static extraction time of 5 min in combination with three static cycles. Quality parameters of the method were established using standards and fish samples. Limits of detection and quantification ranged from 10 to 34 pg g−1 wet weight and between 34 and 68 pg g−1 wet weight, respectively. In addition, good linearity (between 1 and 500 ng ml−1) and high precision (RSD % < 15%) were achieved. The method was validated using the standard reference material SRM-1945 (whale blubber) and was then applied to the analysis of PBDEs in fish samples.  相似文献   

13.
A rapid and reliable analytical method based on pressurised solvent extraction (PSE) and GC-NCI-MS was developed for the determination of 41 different PBDEs in soil. All PBDEs, including mono- to hepta-BDEs (sum of 39 congeners), one nona-BDE and deca-BDE, were efficiently extracted from soil samples using the extraction technology of PSE. The extract was then cleaned up on a florisil column. Satisfactory separation of 41 PBDE congeners was obtained on a 15-m DB-5MS capillary column, saving the use of another 30-m column specific for the separation of mono- to hepta-BDEs. PBDEs were identified and quantified by GC-MS in negative chemical ionisation (NCI) mode, and further confirmed in semi electron impact (SEI) mode when the ion source was also NCI. The method detection limits ranged from 0.01 to 0.03?ng?g?1?dw for mono- to hepta-BDEs, 1.43?ng?g?1?dw for the nona-BDE and 0.20?ng?g?1?dw for deca-BDE. The applicability of the method was tested in soil samples collected from an e-waste recycling site at Guiyu. Twenty-one PBDEs (mono- to deca-) were detected, and eighteen congeners were quantified. The concentration range of PBDEs was 0.78–436?ng?g?1?dw. BDE-47, BDE-99, BDE-153, BDE-183, BDE-206 and BDE-209 were the dominant congeners, and BDE-209 accounted for 62% of the total PBDEs. The congener profiles of PBDEs in soil samples were similar to those in three commercial PBDE products (Penta-, Octa- and Deca-BDE), and Deca-BDE product was the most important contributor.  相似文献   

14.
Polybrominated diphenyl ethers (PBDEs) are a class of flame retardants used globally in many consumer products and industrial applications. Traditionally, gas chromatography–high resolution mass spectrometry (GC–HR-MS) is the method of choice for analysis of PBDEs in environmental samples because it offers high sensitivity and selectivity, resulting in less interferences. However, the specificity offered by gas chromatography-triple quadrupole tandem mass spectrometry (GC–QQQ-MS/MS), operated in selected reaction monitoring mode, provides a more affordable alternative to GC–HR-MS for the analysis of PBDEs in complex environmental samples. In this study, an analytical method was developed for the analysis of 41 PBDE congeners in fish using GC–QQQ-MS/MS. Results from the analysis of three fish species [lake trout (Salvelinus namaycush), yellow perch (Perca flavescens), and round goby (Neogobius melanostomus)] using GC–QQQ-MS/MS were compared with those obtained by GC–HR-MS. These species were selected because they represent varying levels of lipid-rich matrix and contaminant loads. Instrumental limits of detection for the GC–QQQ-MS/MS ranged from 0.04 pg to 41 pg, whereas those for the GC–HR-MS ranged from 5 pg to 85 pg. The PBDE values obtained from these two methods were highly correlated, R2 values >0.7, for all three fish species, supporting the suitability of GC–QQQ-MS/MS for analysis of PBDEs in fish with varying fat content.  相似文献   

15.
A low pressure microwave assisted vapor phase dissolution procedure for silicon nitride and volatilization of in situ generated SiF4 has been developed using H2SO4, HF and HNO3 for the determination of trace impurities present in silicon nitride. Sample was taken in minimum amount (0.5 mL for 100 mg) of H2SO4 and treated with vapors generated from HF and HNO3 mixture in presence of microwaves in a closed container. An 80 psi pressure with ramp and hold times of 30 min and 60 min respectively, operated twice, resulted in 99.9% volatilization of Si. Matrix free solutions were analyzed for impurities using DRC-ICP-MS. The recoveries of Cr, Mn, Fe, Ni, Co, Cu, Zn, Sr, Y, Cd, Ba and Pb were between 80 and 100% after volatilization of Si. The blanks were in lower ng g−1 with method detection limits in lower ng g−1 to sub ng g−1 range. The method was applied for the analysis of two silicon nitride samples.  相似文献   

16.
The coordination polymer [Zn(BDC)(H2O)2]n was tested for extraction of pyrimethanil, ametryn, dichlofluanid, tetraconazole, flumetralin, kresoxim-methyl and tebuconazole from the medicinal plant Hyptis pectinata, with analysis using gas chromatography-mass spectrometry in selected ion monitoring mode (GC/MS, SIM). Experiments carried out at different fortification levels (0.1, 0.5 and 1.0 μg g−1) resulted in recoveries in the range 73-97%, and RSD values were between 5 and 12% for the [Zn(BDC)(H2O)2]n sorbent. Detection and quantification limits ranged from 0.02 to 0.07 μg g−1 and from 0.05 to 0.1 μg g−1, respectively, for the different pesticides studied. The method developed was linear over the range tested (0.04-14.0 μg g−1), with correlation coefficients ranging from 0.9987 to 0.9998. Comparison between [Zn(BDC)(H2O)2]n and the commercial phase C18-bonded silica showed good performance of the [Zn(BDC)(H2O)2]n polymeric sorbent for the pesticides tested.  相似文献   

17.
A micro-solid-phase extraction (μ-SPE) device was developed by filling copper(II) isonicotinate coordination polymer (Cu(4-C5H4N-COO)2(H2O)4) into a porous polypropylene envelope, and the μ-SPE, coupling with gas chromatography (GC) with a micro-cell electron capture detector (μ-ECD), was used for extraction and determination of PBDEs in soils. Variables affecting extraction procedures, including temperature, water volume, extraction time, and desorption time, were investigated in a spiked soil, and the parameters were optimized. Under the optimal experimental conditions, the method detection limits for seven PBDEs (BDE-28, 47, 99, 100, 153, 154, and 183) were in the range of 0.026–0.066 ng g−1, and the reproducibility was satisfactory with the relative standard deviation in range of 1.3–10.1%. Good linear relationship between PBDEs concentrations and GC signals (defined as peak area) was obtained in the range between 0.1 and 200 ng g−1. The recovery of the seven PBDEs by μ-SPE varied from 70 to 90%, which was comparable to that determined by accelerated solvent extraction method. Finally, the proposed method was used to determine PBDEs in several field-contaminated soils, and it was suggested that the μ-SPE is a promising alternative microextraction technique for the detection of PBDEs in soils.  相似文献   

18.
A novel and efficient analytical methodology is proposed for extracting and preconcentrating polybrominated diphenyl ethers (PBDEs) from samples of environmental interest prior gas chromatography–mass spectrometry (GC–MS) analysis. It is based on the induction of micellar organized medium by using a non-ionic surfactant (Triton X-114) to extract the target PBDEs. To enable coupling the efficient extracting technique with GC analysis, ultrasound-assisted back-extraction (UABE) into an organic solvent was required. Several factors, including surfactant type and concentration, equilibration temperature and time, ionic strength, pH and buffers nature and concentration were studied and optimized over the extraction efficiency of the proposed technique. Under optimal experimental conditions, the target analytes were quantitatively extracted achieving an enrichment factor of 250 when 10 mL aliquot of ultrapure water spiked with PBDE-standard mixture (10 pg mL−1 each PBDE) was extracted. Method detection limits (MDLs) calculated with aqueous PBDEs solutions as three times the signal-to-noise ratio (S/N), ranged from 1 to 2 pg mL−1 with RSDs values ≤8.5% (n = 5). The coefficients of estimation of the calibration curves obtained following the proposed methodology were ≥0.9987 and linear range of all PBDEs was 4–150 pg mL−1. The proposed methodology was validated by carrying out a recovery study by spiking the samples at two different concentration levels of PBDEs (10 and 50 pg mL−1 for waters samples). Recoveries values in the range of 96–106% for water samples were obtained showing satisfactory robustness of the method for analyzing PBDEs in water samples. The proposed methodology was applied for the analysis of PBDEs: 2,2′,4,4′-tetraBDE (BDE-47), 2,2′,4,4,5-pentaBDE (BDE-99), 2,2′,4,4,6-pentaBDE (BDE-100) and 2,2,4,4′,5,5′-hexaBDE (BDE-153) in water samples, including drinking, lake, river water and soil samples. Significant quantities of PBDEs were not found in the analyzed samples.  相似文献   

19.
A digestion mixture of H2SO4/HNO3/H2O2/HF/V2O5 was investigated for decomposition of plant samples and sensitive detection of selenium was achieved by hydride generation atomic fluorescence spectrometry (HG-AFS). The method was found to be accurate and reproducible, with a low detection limit (DL) (0.14 ng g−1 solution). The repeatability of the determination was mostly around 10%, the reproducibility over a period of 8 months for determination of selenium in the standard reference material Trace Elements in Spinach Leaves, NIST 1570a, was 9% and the relative measurement uncertainty was 7% using a coverage factor of 2.3 at 95% probability. The average recovery of the whole procedure was 90%. The characteristics of this method are simple and inexpensive equipment, low consumption of chemicals and the ability to analyse many samples in a short time. The whole procedure was carried out in the same PTFE tube, and in addition only a simple cleaning procedure is needed. As a consequence of all these advantages, the described method is suitable for environmental and nutritional studies. The selenium content was determined in 44 vegetable samples from different regions of Slovenia and the contents found were in the range 0.3-77 ng g−1 wet weight.  相似文献   

20.
Porous magnetic composites were prepared by the synthesis of molecular sieve MCM-41 in the presence of Fe3O4 nanoparticles with average diameter of 15 nm. Nanoparticles were captured by porous silica matrix MCM-41, which resulted in their incorporation, as it was confirmed by TEM, SEM and X-ray diffraction. The materials possessed high surface area (392-666 m2 g−1), high pore volume (0.39-0.73 cm3 g−1) along with high magnetic response (MS up to 28.4 emu g−1 at 300 K). Calcination of samples resulted in partial oxidation of Fe3O4 to α-Fe2O3. The influence of nanoparticles content on sorption and magnetic properties of the composites was shown. No hysteresis was found for the samples at 300 K; at 5 K, HC was in the range 370-385 G for non-calcinated samples and 350-356 G for calcinated ones.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号