首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 768 毫秒
1.
An accurate, sensitive and least time consuming reverse phase high performance liquid chromatographic (RP‐HPLC) method for the estimation of captopril in the presence of non steroidal anti‐inflammatory drugs in formulation and human serum has been developed and validated. Chromatographic separation was conducted on prepacked Purospher star C18 (5 μm, 25 × 0.46 cm) column at room temperature using methanol:water (80:20 v/v) as a mobile phase, pH adjusted at 2.8 with o‐phosphoric acid and at a flow rate of 1.0 mL min−1, while UV detection was performed at 227 nm. The limit of detection and quantification for captopril were 1 and 0.35 ng mL−1, while that for (NSAID's) i.e. flurbiprofen, ibuprofen, diclofenac sodium and mefenamic acid LOD were 0.2, 1, 2 and 0.4 ng mL−1 respectively and LOQ were 0.9, 2.9, 8 and 1 ng mL−1 Analytical recovery was > 98.1%. The method used for the quantitative analysis of commonly administered non steroidal anti‐inflammatory drugs (NSAID's) i.e. ibuprofen, flurbiprofen, diclofenac sodium and mefenamic acid alone or in combination with captopril from API (active pharmaceutical ingredients), dosage formulations and in human serum. The established method is rapid (RT < 12 min), accurate (recovery > 98.1%), selective (no interference of excepients and other commonly used drugs and food) and sensitive (LOQ 3.5 ng mL;‐1) and reproducible (SD ± 0.003).  相似文献   

2.
A reliable, high‐throughput and sensitive LC–MS/MS procedure was developed and validated for the determination of five tyrosine kinase inhibitors in human plasma. Following their extraction from human plasma, samples were eluted on a RP Luna®‐PFP 100 Å column using a mobile phase system composed of acetonitrile and 0.01 m ammonium formate in water (pH ~4.1) with a ratio of (50:50, v /v) flowing at 0.3 mL min−1. The mass spectrometer was operating with electrospray ionization in the positive ion multiple reaction monitoring mode. The proposed methodology resulted in linear calibration plots with correlation coefficients values of r 2 = 0.9995–0.9999 from concentration ranges of 2.5–100 ng mL−1 for imatinib, 5.0–100 ng mL−1 for sorafenib, tofacitinib and afatinib, and 1.0–100 ng mL−1 for cabozantinib. The procedure was validated in terms of its specificity, limit of detection (0.32–1.71 ng mL−1), lower limit of quantification (0.97–5.07 ng mL−1), intra‐ and inter assay accuracy (−3.83 to +2.40%) and precision (<3.37%), matrix effect and recovery and stability. Our results demonstrated that the proposed method is highly reliable for routine quantification of the investigated tyrosine kinase inhibitors in human plasma and can be efficiently applied in the rapid and sensitive analysis of their clinical samples.  相似文献   

3.

A new, sensitive and stability indicating liquid chromatographic method has been developed for the determination of imatinib mesylate (IM). Efficient chromatographic separation was achieved using a C18 column with simple mobile phase combination delivered in an isocratic mode and quantitation was carried out using ultraviolet detection. For the first time, a novel microwave assisted degradation procedure was employed for stress testing studies. In addition, orthogonal separation technique was applied to demonstrate selectivity of the proposed method. The method has demonstrated excellent linearity over the range of 25–1,600 ng mL−1. Moreover, the method was found to be sensitive with a low limit of detection (3.35 ng mL−1) and limit of quantitation (10.16 ng mL−1). The method has shown good and consistent recoveries (99.35–100.69%) with low intra- and inter-day relative standard deviation (RSD) (<2.5%). Experimental design confirmed that peak area was unaffected by small changes in critical factors, in robustness study. The validated method was successfully applied for determination of IM in pharmaceutical formulations.

  相似文献   

4.
Amantadine (AMA) is an anti‐viral drug used in apiculture to protect honeybee against the sacbrood virus (Morator aetatulae). This study described a reliable high‐performance liquid chromatographic (HPLC) method for analyzing AMA in honey using a solid‐phase extraction (SPE) cartridge (Plexa PCX) for purification, 4‐fluoro‐7‐nitro‐2,1,3‐benzoxadiazole (NBD‐F) as a pre‐column derivatization agent, and fluorometric detection (λex=470 nm, λem=530 nm). The chromatographic separation was performed on an XDB C18 column (150×4.6 mm i.d.) using 0.1% trifluoroacetic acid/acetonitrile (35:65,V/V) as the mobile phase at a flow rate of 1.0 mL·min−1 with a run time of 20 min. Under these optimal conditions, a linear relationship was observed in the range of 0.025–1.0 µg· mL−1 with a good correlation coefficient (0.998) and low limit of detection (0.0080 µg·g−1), the recoveries were all above 90%, and the intra‐day and inter‐day precision (RSD) ranged from 3.4%–5.1%.  相似文献   

5.
A simple and highly sensitive liquid chromatography–tandem mass spectrometry (LC‐MS/MS) bioanalytical method was developed and fully validated for the first time for the simultaneous determination of newly discovered antiviral drugs, namely sofosbuvir (SOF) and daclatasvir (DAC) in human plasma. Tadalafil (TAD) was used as internal standard (IS). SOF, DAC and TAD (IS) were extracted from plasma using liquid–liquid extraction technique with methyl tert‐butyl ether. The chromatographic separation was carried out using ZorbaxSB‐C18 column (4.6 × 50 mm,5 μm) and 5 mm ammonium formate buffer (pH 3.5)–acetonitrile (50:50, v/v) as mobile phase in an isocratic elution mode pumped at a flow rate 0.7 mL min−1. The quantitation was performed on API4500 triple quadrupole tandem mass spectrometer with positive electrospray ionization interface in multiple reaction monitoring mode. Validation was applied according to US Food and Drug Administration guidelines for bio‐analytical methodswith respect to linearity, precision, accuracy, selectivity, carry‐over, stability and dilution integrity. Linearity was obtained over concentration ranges of 0.3–3000 and 3–3000 ng mL−1 for SOF and DAC, respectively, by applying a weighted least‐squares linear regression method (1/x2). The proposed method could be applied successfully in bioequivalence and/or clinical studies for therapeutic drug monitoring of patients undergoing dual combination therapy as the latter combination proved more efficacious and powerful tool for the complete treatment of hepatitis C genotype 3 within 16 weeks. The suggested method has been applied successfully to pharmacokinetic studies with excellent assay ruggedness and reproducibility.  相似文献   

6.
A simple, specific, sensitive and rapid LC‐ESI‐MS/MS method has been developed and validated for the quantification of 4‐methylpyrazole in dog plasma using N‐methylnicotinamide‐d4 as an internal standard (IS) as per regulatory guidelines. Sample preparation was accomplished through a simple protein precipitation. Chromatographic separation of 4‐methylpyrazole and the IS was performed on a monolithic (Chromolith RP18e) column using an isocratic mobile phase comprising 0.2% formic acid in water and acetonitrile (20:80, v/v) at a flow rate of 1.0 mL/min. Elution of 4‐methylpyrazole and the IS occurred at ~1.60 and 1.56 min, respectively. The total chromatographic run time was 3.2 min. A linear response function was established in the concentration range of 4.96–4955 ng/mL. The intra‐ and inter‐day accuracy and precision were in the ranges 1.81–12.9 and 3.80–11.1%, respectively. This novel method has been applied to a pharmacokinetic study in dogs.  相似文献   

7.
The aim of the present study was to develop a simple, sensitive and accurate liquid chromatography–electrospray ionization tandem mass spectrometry (ESI‐MS/MS) method for the determination of lixivaptan (LIX) in mouse plasma using vildagliptin as the internal standard (IS). A precipitation procedure was used for the extraction of LIX and vildagliptin from mouse plasma. Chromatographic separation of LIX was achieved using a C18 analytical column (50 × 2.1 mm, 1.8 μm) at 25°C. The mobile phase comprised acetonitrile and ammonium formate (10 mm , pH 3.1; 40:60, v /v) pumped at a flow rate of 0.3 mL min−1. A tandem mass spectrometer with an electrospray ionization source was used to perform the assay. Quantification of LIX at m/z 290 → 137 and IS at 154 → 97 was attained through multiple reaction monitoring. The investigated method was authenticated following the bio‐analytical method of validation guidelines of the US Food and Drug Administration. The developed method showed a good linearity over the concentration range from 5 to 500 ng mL−1, and the calibration curve was linear (r = 0.9998). The mean recovery of LIX from mouse plasma was 99.2 ± 0.68%. All validation parameters for LIX were within the levels required for acceptance. The proposed method was effectively used for a pharmacokinetic study of LIX in mouse plasma.  相似文献   

8.
A method using high‐performance liquid chromatography coupled with tandem mass spectrometry was developed for the simultaneous determination of organic acids in microalgae. o‐Benzylhydroxylamine was used to derivatize the analytes, and stable isotope‐labeled compounds were used as internal standards for precise quantification. The proposed method was evaluated in terms of linearity, recovery, matrix effect, sensitivity, and precision. Linear calibration curves with correlation coefficients >0.99 were obtained over the concentration range of 0.4–40 ng/mL for glycolic acid, 0.1–10 ng/mL for malic acid and oxaloacetic acid, 0.02–2 ng/mL for succinic acid and glyoxylic acid, 4–400 ng/mL for fumaric acid, 20–2000 ng/mL for isocitric acid, 2–200 ng mL−1 for citric acid, 100–10000 ng mL−1 for cis‐aconitic acid, and 1–100 ng mL−1 for α‐ketoglutaric acid. Analyte recoveries were between 80.2 and 115.1%, and the matrix effect was minimal. Low limits of detection (0.003–1 ng/mL) and limits of quantification (0.01–5 ng/mL) were obtained except cis‐aconitic acid. Variations in reproducibility for standard solution at three different concentrations levels were <9%. This is the first report of the simultaneous analysis of ten organic acids in microalgae, which promotes better understanding of their growth state and provides reference value for high‐yield microalgae cultures.  相似文献   

9.
A method for the simultaneous determination of aluminum (Al), cadmium (Cd) and lead (Pb) in whole blood has been developed by using simultaneous atomic absorption spectrometry (SIMAAS) with oxygen charring. The optimized conditions for the simultaneous determination of Al, Cd and Pb were obtained in the presence of palladium (Pd) as the chemical modifier, using 600 °C and 2400 °C as the pyrolysis and the atomization temperature, respectively. The whole blood samples were diluted 1+5 (v/v) directly with 0.1% (v/v) Triton X‐100. Oxygen was employed to eliminate the interference of carbonaceous residues in the charring step before pyrolysis. The calibration curves were carried out with aqueous standard solutions and the linear ranges were 0–40 ng mL−1, 0–4 ng mL−1 and 0–40 ng mL−1 for Al, Cd and Pb, respectively. The detection limits were 0.96 ng mL−1 (19.2 pg) for Al, 0.03 ng mL−1 (0.6 pg) for Cd and 0.60 ng mL−1 (12.0 pg) for Pb. The spiked recoveries of Al, Cd and Pb in whole blood were 98.0%, 100.0% and 101.7%, respectively. The accuracy of the proposed method was evaluated with the analysis of a whole blood certified reference material (Seronorm, level 2). The found concentrations were in agreement with the recommended values. The proposed method has been successfully applied to the simultaneous determination of Al, Cd and Pb in whole blood of healthy volunteers before and after eating barbecued foods.  相似文献   

10.
A simple and specific bioanalytical method based on reversed‐phase high‐performance liquid chromatography (RP‐HPLC) coupled with ultraviolet detection was developed and validated for the determination of a novel valproic acid arylamide, N‐(2‐hydroxyphenyl)‐2‐propylpentanamide (HO‐AAVPA) in rat hepatic microsomes (a subcellular fraction containing phase I enzymes, especially cytochrome P450). The chromatographic separation was achieved using a reversed‐phase Zorbax SB‐C18 column and a mobile phase of acetic acid in water (0.2% v/v) and acetonitrile (40:60 v/v) with a flow rate of 0.5 mL/min. The calibration curve was linear over the range of 882–7060 ng/mL (r2 = 0.9987), and the lower limit of quantification and the lower limit of determination were found to be 882 and 127.99 ng/mL, respectively. The method was validated with excellent sensitivity, and intra‐day accuracy and precision varied from 93.79 to 93.12%, and from 2.12 to 4.36%, respectively. The inter‐day accuracy and precision ranged from 93.29 to 97.30% and from 0.68 to 3.60%, respectively. The recovery of HO‐AAVPA was measured between 91.36 and 97.98%. The assay was successfully applied to the analysis of kinetic metabolism and pharmacokinetic parameters in vitro by a substrate depletion approach. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
Senkyunolide I is one of the major bioactive components in the herbal medicine Ligusticum chuanxiong. The aim of this study was to develop and validate a fast, simple and sensitive LC‐MS/MS method for the determination of senkyunolide I in dog plasma. The plasma samples were processed with acetonitrile and separated on a Waters Acquity UPLC BEH C18 column (50 × 2.1 mm, 1.7 μm). The mobile phase consisted of 0.1% formic acid aqueous and acetonitrile was delivered at a flow rate of 0.3 mL min−1. The detection was achieved in the positive selected reaction monitoring mode with precursor‐to‐product transitions at m/z 225.1 → 161.1 for senkyunolide I and at m/z 349.1 → 305.1 for an internal standard. The assay was linear over the tested concentration range, from 0.5 ng mL−1 to 1000 ng mL−1, with a correlation coefficient >0.9992. The mean extraction recovery from dog plasma was within the range of 85.78–93.25%, while the matrix effect of the analyte was within the range of 98.23–108.89%. The intra‐ and inter‐day precisions (RSD) were <12.12% and the accuracy (RR) ranged from 98.89% to 104.24%. The validated assay was successfully applied to pharmacokinetic and bioavailability studies of senkyunolide I in dogs. The results demonstrated that (a) senkyunolide I showed short elimination half‐life (<1 h) in dog, (b) its oral bioavailability was >40% and (c) senkyunolide I showed dose‐independent pharmacokinetic profiles in dog plasma over the dose range of 1–50 mg kg−1.  相似文献   

12.
A porous carbon designated as MOF‐5‐C was prepared by directly carbonizing a metal–organic framework (MOF‐5). The morphology and microstructure of MOF‐5‐C were characterized by scanning electron microscopy, N2 adsorption, and powder X‐ray diffraction. The MOF‐5‐C retained the original porous structures of MOF‐5, and showed a high Brunauer–Emmett–Teller surface area (1808 m2 g?1) and large pore volume (3.05 cm3 g?1). To evaluate its adsorption performance, the MOF‐5‐C was used as an adsorbent for the solid‐phase extraction of four phthalate esters from bottled water, peach juice, and soft drink samples followed by high‐performance liquid chromatographic analysis. Several parameters that could affect the extraction efficiencies were investigated. Under the optimum conditions, a good linearity was achieved in the concentration range of 0.1–50.0 ng mL?1 for bottled water sample and 0.2–50.0 ng mL?1 for peach juice and soft drink samples. The limits of detection of the method (S/N = 3) were 0.02 ng mL?1 for bottled water sample, and 0.04–0.05 ng mL?1 for peach juice and soft drink samples. The results indicated that the MOF‐5‐C exhibited an excellent adsorption capability for trace levels of phthalate esters, and it could be a promising adsorbent for the preconcentration of other organic compounds.  相似文献   

13.
A novel generic reverse phase high performance liquid chromatography (RP‐HPLC) method is developed and validated for simultaneous determination of seven pharmaceutically active ingredients, namely, acetaminophen, dextromethorphan, doxylamine, phenylephrine, guaifenesin, caffeine and aspirin. All seven ingredients were quantified in soft gel, syrup and tablet formulations of the over‐the‐counter US‐marketed products, as per the guidelines of the International Conference on Harmonization. The separation was achieved in a 16 min run time on an Agilent Zorbax Phenyl column using a gradient method with two mobile phases. Mobile phase A was 0.15% trifluoro acetic acid in purified water and while mobile phase B was a mixture of acetonitrile and methanol (750:250 v/v) with 0.02% trifluoro acetic acid. The flow rate was 1.0 mL min?1 and injection volume was 10 μL. Detection was performed at 280 nm using a photodiode array detector. As part of the method validation, specificity, linearity, precision and recovery parameters were verified. The concentration and area relationships were linear (R2 > 0.999), over the concentration ranges 20–120 μg mL?1 for acetaminophen, 75–450 μg mL?1 for dextromethorphan, 31.25–187.5 μg mL?1 for doxylamine, 25–150 μg mL?1 for phenylephrine, 25–150 μg mL?1 for aspirin, 6.5–39 μg mL?1 for caffeine and 12–72 μg mL?1 for guaifenesin. The relative standard deviations for precision and intermediate precision were <1.5%. The proposed RP‐HPLC generic method is applicable for routine analysis of cold and cough over‐the‐counter products.  相似文献   

14.
Qiaozhen Guo  Zhenxia Du 《中国化学》2011,29(9):1922-1926
A simultaneous method was successfully established and validated for the separation and determination of buprenorphine (BP), its primary metabolite, nor‐buprenorphine (NBP) and a proposed co‐formulate, naloxone (NLX) in human plasma. The method used buprenorphine‐d4 (BP‐D4), nor‐buprenorphine‐d3 (NBP‐D3), naltrexone (NTX) as internal standards (ISs). 100 μL of plasma sample fortified with the ISs was cleaned up by solid‐phase extraction (SPE), and was then separated on a Waters AcquityTM BEH C18 column with gradient elution using methanol and water (containing 0.2% formic) at a flow rate of 0.25 mL·min−1. The mass spectrometer was used for detection and was operated in the positive electrospray ionization with multiple reaction monitoring (MRM) mode. The three compounds were effectively separated in 5 min. The linear ranges of the compounds were 0.1–25, 0.25–25 and 0.05–25 ng·mL−1 for BP, NBP and NLX, respectively, with r≧0.9935. The method had high sensitivity (the limits of detection were 0.02, 0.1 and 0.01 ng·mL−1 for BP, NBP and NLX, respectively) and high recoveries (≧97.6%). The result was shown to be linear and satisfactorily met current acceptance criteria for validation of bioanalytical method: intra and inter assay precisions within the required limits of ≦25% RSD. The LOQs fulfilled the LOQ requirements: precision≦25% RSD, and was fully validated according to the State Food and Drug Administration (SFDA) regulations. The results demonstrated that ultra‐high performance liquid chromatography‐tandem mass spectrometer (UPLC‐MS/MS) with SPE was a powerful detection tool and contributed to pharmaceutical analysis in biological matrices.  相似文献   

15.
A fast, selective and sensitive ultraperformance liquid chromatography–tandem mass spectrometry method was developed for determination and pharmacokinetic study of anastrozole in human plasma. Plasma sample pretreatment involved a one‐step extraction with diethyl ether of 500 µL plasma. The chromatographic separation was carried out on an Acquity UPLCTM BEH C18 column with a mobile phase consisting of methanol–10 mmol/L ammonium acetate (75:25, v/v) at a flow rate of 0.30 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring via electrospray ionization source with positive mode. A high throughput was achieved with a run time of 1.5 min per sample. The standard curve for anastrozole was linear (r2 ≥ 0.99) over the concentration range of 0.0550–27.5 ng/mL with a lower limit of quantification of 0.0550 ng/mL. The intra‐ and inter‐day precision (relative standard deviation) values were not higher than 14% and the accuracy (relative error) was within ±3.2% at three quality control levels. This simple, fast and highly sensitive method was fully validated and successfully applied to a clinical pharmacokinetic study of anastrozole in healthy volunteers after oral administration. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
A new, simple, accurate and precise high‐performance thin‐layer chromatographic method has been developed and validated for simultaneous determination of an anthelmintic drug, albendazole, and its active metabolite albendazole, sulfoxide. Planar chromatographic separation was performed on aluminum‐backed layer of silica gel 60G F254 using a mixture of toluene–acetonitrile–glacial acetic acid (7.0:2.9:0.1, v /v/v) as the mobile phase. For quantitation, the separated spots were scanned densitometrically at 225 nm. The retention factors (R f) obtained under the established conditions were 0.76 ± 0.01 and 0.50 ± 0.01 and the regression plots were linear (r 2 ≥ 0.9997) in the concentration ranges 50–350 and 100–700 ng/band for albendazole and albendazole sulfoxide, respectively. The method was validated for linearity, specificity, accuracy (recovery) and precision, repeatability, stability and robustness. The limit of detection and limit of quantitation found were 9.84 and 29.81 ng/band for albendazole and 21.60 and 65.45 ng/band for albendazole sulfoxide, respectively. For plasma samples, solid‐phase extraction of analytes yielded mean extraction recoveries of 87.59 and 87.13% for albendazole and albendazole sulfoxide, respectively. The method was successfully applied for the analysis of albendazole in pharmaceutical formulations with accuracy ≥99.32%.  相似文献   

17.
A simple and high sensitive ultra‐high‐performance liquid chromatography tandem mass spectrometry method for the determination of fludrocortisone in human plasma was developed and validated as per guidelines. The analyte and internal standard (IS), fludrocortisone‐d5, were extracted from human plasma via liquid–liquid extraction using tert‐butyl methyl ether. The chromatographic separation was achieved on a Chromolith RP18e column using a mixture of acetonitrile and 2 mm ammonium formate (70:30, v/v) as the mobile phase at a flow rate of 0.7 mL/min. Quantitation was performed on a triple quadrupole mass spectrometer employing electrospray ionization technique, operating in multiple reaction monitoring and positive ion mode. The precursors to product ion transitions monitored for fludrocortisone and IS were m/z 381.2 → 343.2 and 386.2 → 348.4, respectively. The assay was validated with linear range of 40–3000 pg/mL. The intra‐ and inter‐day precisions (relative standard deviation) were within 0.49–7.13 and 0.83–5.87%, respectively. The proposed method was successfully applied to pharmacokinetic studies in humans. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

18.
&#;nal  A.  Olcay Sa&#;irli  A.  M&#;ge &#;etin  S.  Toker  S. 《Chromatographia》2007,66(1):103-107

A rapid, simple, accurate, sensitive and reproducible high performance liquid chromatographic method for the quantitation of reboxetine (REB) in human plasma using fluvoxamine as an internal standard (IS) has been developed and validated. The method is based on derivatization with 7-chloro-4-nitrobenzofurazan (NBD-Cl). The NBD-derivatives in plasma were extracted by liquid–liquid extraction and chromatographed on a reversed phase C18 column with isocratic elution using acetonitrile and aqueous nitric acid (pH 3) solution. Calibration curve was linear over the range 2.0–200.0 ng mL−1 with inter- and intra-assay precision (RSD%) of less than 4%. The mean recovery was about 94% for REB. The applicability of the method to the plasma was also studied.

  相似文献   

19.
A simple and highly sensitive ultra‐high‐performance liquid chromatographic–diode array (UHPLC‐DAD) detection method was developed and validated for the simultaneous estimation of levetiracetam (LEV) and lacosamide (LAC). It was clinically proven that the combination of LEV and LAC exhibits a synergistic effect against refractory seizures in mice, which was the motivation for the analysis of this binary mixture both in bulk and in human urine samples. The binary mixture was resolved on a Hypersil BDS C18 analytical column, utilizing a mobile phase of 0.050 mol L?1 phosphate buffer (pH 5.60), methanol and acetonitrile in the ratio (80:10:10 v/v/v) using catechol as an internal standard. The mobile phase was pumped at a flow rate of 1.2 mL min?1 with diode array detection at 205 nm for both drugs and 270 nm for IS. Calibration curves were linear with correlation coefficient >0.9990 over the studied concentration range of 0.1–70.0 μg mL?1 for both drugs. The developed method was reproducible with low relative standard deviation values for intra‐ and inter‐day precision (<2.0%). Both drugs were determined in bulk, pharmaceutical formulations and human urine samples without any interference from complex matrices.  相似文献   

20.
《Analytical letters》2012,45(1):68-83
Abstract

A simple and reliable high-performance liquid chromatographic (HPLC) method was developed for the determination of belotecan in the plasma, urine, and bile samples of rats. Belotecan was analyzed with HPLC using a C18 column with fluorescence detector. A mixture of acetonitrile–0.1 M potassium phosphate buffer at pH 2.4 (25:75, v/v) and 0.2% trifluoroacetic acid was used as the mobile phase. The lower limits of quantitation (LOQ) were 5 ng mL?1 for the plasma and 5 µg mL?1 for the urine and bile samples. The method has been readily applied for the routine pharmacokinetic study of belotecan in small laboratory animals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号