相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
采用门控进样,在简单的十字通道微流控玻璃芯片上实现了假随机多次进样,研究了利用哈达玛变换提高微流控毛细管电泳分析系统信噪比的方法.在实验中,以7阶127步假随机二进制序列作为进样模板,将缓冲液和Cy5衍生后的氨基酸试样交替注入到分离通道中,检测到的电泳信号经过哈达玛反变换还原使信噪比提高5倍(理论上5.6倍)的电泳谱,各组分的出峰时间、峰高和峰形均完全还原,毛细管电泳分离的采样频率不受影响.  相似文献   

2.
A concentration detection limit of 100 fM was achieved for the fluorescein ion by improving the experimental setup used for Hadamard transform capillary electrophoresis. Two argon-ion lasers, a gating laser for sample injection and a probe laser for the excitation of analyte molecules, were employed for the efficient photodegradation of analyte molecules in laser-induced fluorescence detection using an optically gated sample-injection method. In addition, a dichroic mirror, located in the pathway of the probe laser was used to exclude the other lines of the argon-ion laser. Using a Hadamard matrix on the order of 2046, the concentration limit of detection for fluorescein ion was determined to be 100 fM at S/N = 3, in which the average number of molecules in a single injection volume was calculated to be 27. The influences of the output power in both the gating and probe lasers on the sensitivity are also discussed.  相似文献   

3.
Gao L  Patterson EE  Shippy SA 《The Analyst》2006,131(2):222-228
A simple automated nanoliter scale injection device which allows for reproducible 5 nL sample injections from samples with a volume of <1 microL is successfully used for conventional capillary electrophoresis (CE) and Hadamard transform (HT) CE detection. Two standard fused silica capillaries are assembled axially through the device to function as an injection and a separation capillary. Sample solution is supplied to the injection capillary using pressure controlled with a solenoid valve. Buffer solution flows gravimetrically by the junction of the injection and separation capillaries and is also gated with a solenoid valve. Plugs of sample are pushed into the space between the injection and separation capillaries for electrokinectic injection. To evaluate the performance of the injection device, several optimizations are performed including the influence of flow rates, the injected sample volume and the control of the buffer transverse flow on the overall sensitivity. The system was then applied to HT-CE-UV detection for the signal-to-noise ratio (S/N) improvement of the nitric oxide (NO) metabolites, nitrite and nitrate. In addition, signal averaging was performed to explore the possibility of greater sensitivity enhancements compared to single injections.  相似文献   

4.
Hadamard transform capillary electrophoresis (HTCE) based on electrokinetic injection allows laser-induced fluorescence detection using a small laser, namely the laser-diode-pumped YAG laser, as an excitation source. A small hole is fabricated at the center of a capillary by laser ablation; this hole functions as an inlet port for a sample solution. Therefore, the sample solution can be introduced electrophoretically into the capillary through the small hole. Multiple sample injection is accomplished by introducing a buffer solution from the end of the capillary and the sample solution through the hole. Both solutions are injected using two sets of high-voltage power supplies and migrate toward the opposite end of the capillary. A fluorescent analyte, rhodamine B, is successfully detected in the case of both single and multiple injection according to the Hadamard sequence code. By transforming the data encoded by the Hadamard matrix, the decoded data showed an increase in the signal-to-noise (S/N) ratio by a factor of 9.8. In the case of the sample containing two amino acids labeled with rhodamine B isothiocyanate (RBITC), although the concentration of every component including free RBITC is lower than the concentration limit of detection obtained by single injection, a substantial improvement in the sensitivity is achieved and all components are identified by the Hadamard transform technique.  相似文献   

5.
A selective and sensitive method was developed for separation and simultaneous determination of catecholamines and amino acids by MEKC with LIF. Interestingly enough, such work has been firstly performed on catecholamines derivatized with 4-chloro-7-nitro-2,1,3-benzoxadiazole and the detailed derivatization mechanism was discussed. After derivatization at 60 degrees C for 20 min, NBD-labeled catecholamines and amino acids were separated in a buffer system containing 10 mM sodium tetraborate-Na2HPO4, 20 mM SDS, and 10% v/v ACN at pH 9.75. SDS micelles were employed to improve the fluorescence intensity of catecholamine derivatives efficiently. Under optimum conditions, two catecholamines and 11 amino acids were separated in a short 13 min analysis time and the RSDs for migration time and peak area were less than 0.60 and 6.50%, respectively. The method was successfully applied for the quantification of catecholamines and amino acids in Portulaca oleracea L., human urine sample, and mixed injection sample.  相似文献   

6.
Advantageous features (enhanced sensitivity and low baseline noise) of the multiplex measuring procedure, the Hadamard transform capillary electrophoresis (HT-CE), are experimentally demonstrated and critically discussed. To perform a perfect multiplex experiment in CE, sample species need to be dissolved in the background electrolyte medium and have very low concentration. The mismatch of electric conductivity resulting from a sample dissolved in water or in a separation buffer diluted with water will lead to sample stacking and corrupting the anticipated outcome. The multiplex measurements were carried out with benzyltriethylammonium bromide, resorcinol and 3,5-dihydroxybenzoic acid in the phosphate buffer, 511 sample/buffer injections were performed into the capillary according to the pseudorandom binary sequence. The averaged electropherogram of the single injection was calculated from the detection signal with the aid of the Fourier transform. The results illustrate the detrimental effect of sample matrix dilution with water and the effect of increased initial sample concentration on the multiplex measurement in CE. Multiplex advantage, in theory possible in the HT-CE, can be obtained at low concentration levels feasible with laser induced fluorescence and optically gated sampling. To achieve successful multiplex measurements with the UV detector, the single injection signal should be approximately at the baseline noise level.  相似文献   

7.
A high‐speed separation method of capillary MEKC with LIF detection had been developed for separation and determination of amino acids in laver. The CE system comprised a manual slotted‐vial array (SVA) for sample introduction that could improve the separation efficiency by reducing injection volume. Using a capillary with 80 mm effective separation length, the separation conditions for amino acids were optimized. Applied with the separation electric field strength of 300 V/cm, the ten amino acids could be completely separated within 2.5 min with 10 mol/L Na2HPO4–NaOH buffer (pH = 11.5) including 30 mmol/L SDS. Theoretical plates for amino acids ranged from 72 000 to 40 000 (corresponding to 1.1–2.0 μm plate heights) and the detection limits were between 25 and 80 nmol/L. Finally, this method was applied to analyze the composition of amino acids in laver and eight known amino acids could be found in the sample. The contents of five amino acids, tyrosine, glutamic acid, glycine, lysine, and aspartic acid that could be completely separated in real sample were determined. The recoveries ranged from 82.3% to 123% that indicated the good reliability for this method in laver sample analysis.  相似文献   

8.
Capillary zone electrophoresis with end-column amperometric detection at a copper microdisk electrode (100 μm in diameter) was successfully applied for simultaneous determination of carbohydrates and amino acids. Under the separation voltage of 27 kV and the separation electrolyte of 80 mM NaOH in a 75 cm fused silica capillary (10 μm i.d. × 375 μmU o.d.), complete separation of a standard mixture containing 9 carbohydrates and 12 amino acids was achieved in less than 25 min. With the electrokinetical injection of 5.4 s at 27 kV and the detection potential of 0.62 V vs. Ag/AgCl, the detection limits (S/N = 3) were 0.22–0.65 ppm (1.2–1.9 μM) for carbohydrates and 0.31–6.5 ppm (2.3–39 μM) for amino acids, respectively. The calculated numbers of theoretical plates were between 41,000 and 190,000. The use of this method for analysis of carbohydrates and amino acids in a urine sample was demonstrated.  相似文献   

9.
A novel, easy and accurate capillary electrophoresis (CE) coupled with flow injection (FI) method for the separation and determination of aspartic acid (Asp) enantiomers by on-line derivatization had been developed, and it had been applied to the real sample for the first time. The derivatization reagents were o-phthalaldehyde (OPA) and mercaptoethanol (ME), which were obtained easily, the chiral selector was beta-cyclodextrin (beta-CD), the micellar chemical was sodium dodecyl sulfate (SDS), and the modifier was methanol. By on-line derivatization, aspartic acid enantiomers were automatically and reproducibly converted to the ultraviolet (UV)-absorbing diastereoisomer derivates, which were separated by micellar electrokinetic chromatography (MEKC). According to the factors affecting the separation and sensitivity of aspartic acid enantiomer and other amino acids in the real sample, the pH value and concentration of the buffer, the concentration of beta-CD and SDS, the volume percentage of the methanol (v/v) in the buffer, the applied voltage and the conversion time were selected as the investigating variates. Under the investigated separation conditions, D-aspartic acid (D-Asp), L-aspartic acid (L-Asp) and other four amino acids achieved the baseline separation in not only the standard mixture of amino acids but also the real sample (Compound Amino Acid Injection (6AA)). The repeatability (defined as relative standard deviation (RSD), n = 5) was 4.0% and 4.0% with peak area evaluation, and 4.2% and 3.7% with peak height evaluation for D-Asp and L-Asp in the real sample. Recovery at added standard levels of 1.0, 3.0 and 6.0 mM was 92%, 104% and 109%, respectively.  相似文献   

10.
With the release of the human genome sequence, there has been increasing attention given to other genetic analyses, including the detection of genetic variations and fast sequencing of multiple samples for pharmacogenomics studies. Rapid injections of samples in multiplexed separation channels by optically gated sample introduction are shown here for DNA separation. Serial separations of four amino acids are shown in less than four seconds on a microchip with four multiplexed channels. Five short oligonucleotides have also been rapidly separated in 2% LPA with four channels using this technique. In addition, multiple unique samples have been simultaneously separated and five-base resolution has been demonstrated.  相似文献   

11.
A Hadamard transform-capillary electrophoresis-UV (HT-CE-UV) detection technique is described for the analysis of biological samples. Pseudorandom injections of sample and buffer according to a simplex matrix obtained from the corresponding Hadamard matrix is performed with conventional capillaries. Alternating injections are achieved with a novel capillary "T" connector created by drilling conventional capillary dimensions through a 1-cm diameter polycarbonate disc. This connector design coupled with a switching system allows for rapid, electrokinetic injections of solution into alternating sample and buffer capillary arms for UV detection. The standard mixtures of nitric oxide (NO) metabolites, nitrite and nitrate, dissolved in physiological saline solution are injected into the separation capillary according to an 83-element injection sequence to obtain a signal-to-noise ratio (S/N) enhancement of ca. 4.5 over a single injection. Nitrite, being the less concentrated metabolite in NO detection and thereby more difficult to detect, was calibrated with the HT-CE-UV method and a limit of detection (LOD) of 0.56 microM was obtained. Rat blood plasma was analyzed with this detection system and demonstrated to be comparable with NO metabolite concentrations of previously published results. This HT-CE-UV method is described where a unique reservoir tube design that contains 8-microL standard nitrite sample volumes is placed over the end of the capillary arm to explore low volume limits for biological samples.  相似文献   

12.
It was demonstrated that a separation of 20 amino acids constituting a protein and three phosphoamino acids that mostly frequently occur in eukaryotes was achieved within 15 min by capillary electrophoresis coupled with lamp-induced fluorescence detection. Fluorescein isothiocyanate was employed as the fluorescence label to facilitate the fluorescence detection of the 23 amino acid species. The fluorescent derivatization conditions and separation parameters including concentration of electrolyte, surfactant in buffer, applied voltage and sample injection were investigated in detail and optimized. The influence of buffer additives such as methanol, acetone and polyvinylpyrrolidone on separation selectivity and sensitivity were discussed. We showed that addition of 2% polyvinylpyrrolidone into the running buffer could dramatically enhance the separation selectivity of amino acids at the expense of a decrease of sensitivity of phosphoamino acids. Under the optimized conditions, the detection limits (S/N=2) ranged from 1.90 x 10(-8) M to 5.66 x 10(-8) M with an average efficiency of 620,000/m. The method was applied to characterization of the phosphorylation of a novel protein kinase RCaMBP (calcium/calmodulin-binding protein kinase) encoded by a cDNA newly isolated and cloned from rice. We verified that RCaMBP belonged to a type of Ser/Thr kinase, providing insight into its function in signal transduction.  相似文献   

13.
采用场增强样品堆积-毛细管电泳法建立了在线富集氨基酸的分析方法,用于中药山楂中水解氨基酸的检测,并进行了回收率实验. 采用富集电压为-20 kV,进样压力为3 psi,进样时间为50 s,紫外检测波长为214 nm,运行缓冲溶液为270 mmol/L乙酸-270 mmol/L乙酸钠(pH=4.15)-6%(V/V)乙腈溶液,分离电压为17 kV,组氨酸、精氨酸、色氨酸、酪氨酸、缬氨酸、苯丙氨酸、亮氨酸、苏氨酸、丙氨酸、甘氨酸、谷氨酸和门冬氨酸等12种氨基酸在50 min内达到分离,检出限在0.000 3~0.08 μg/mL之间.  相似文献   

14.
An MEKC method was developed for the separation and characterization of phenyl-isothiocyanate (PITC)-labeled amino acids derived from Gonometa rufobrunnae silkworm after microdialysis sample cleanup. The influence of the buffer and SDS concentration on the resolution of the amino acids was investigated. A buffer system consisting of 25 mM phosphate, 10 mM borate buffer at pH 9.00, and 70 mM SDS showed the best results, with 13 PITC-amino acid derivatives being resolved out of 15 possible amino acids that were under study. Microdialysis sampling demonstrated its efficiency as a sample cleanup technique. Sericin protein from G. rufobrunnae was found to be characterized by at least 11 positively identified amino acids. These included His, Tyr, Ser, Ala, Phe, Lys, Gly, Arg, Cys, Glu, and Asp. Leu/Met and Val/Thr were coeluting pairs and hence could not be positively confirmed.  相似文献   

15.
The separation of 21 free amino acids as their isobutyl N(O,S)-pentafluorobenzoyl derivatives by capillary gas chromatography with electron-capture detection is described. This method has been successfully applied to routine analysis of most of these amino acids in brain tissue and urine. The amino acids are converted to their isobutyl N(O,S)-pentafluorobenzoyl derivatives by acid-catalysed esterification followed by aqueous extractive pentafluorobenzoylation. The 21 amino acids can be separated on a single capillary column in 21 min. The high sensitivity permits analysis in minute quantities of sample and the high stability permits the use of an automatic sample injector at ambient temperatures. Thus, over 50 samples can be readily analyzed in a single day.  相似文献   

16.
胶束在线扫集毛细管电泳法测定三聚氰胺   总被引:1,自引:0,他引:1  
研究胶束在线扫集毛细管电泳法测定三聚氰胺的可行性,结果表明,与区带毛细管电泳相比,胶束在线扫集毛细管电泳法富集倍数提高约60倍。缓冲体系为140 mmol/L SDS+20 mmol/L NaH2PO4(pH 2.20)+10%(体积分数)甲醇,分离电压-18 kV,进样时间30 s,测量波长214 nm。考察了SDS浓度、pH、进样时间、运行电压等因素对分离测定的影响情况。在优化条件下,三聚氰胺在9 min时出峰,峰面积RSD≤3.7%。方法检出限、线性范围、相关系数分别为:0.13μg/mL、0.50~32.0μg/mL、0.9997。方法可用于奶粉中三聚氰胺的分离测定。  相似文献   

17.
A high‐speed CE system for multiple samples was developed based on a short capillary and an automated sample introduction device consisting of a commercial multi‐well plate and an x‐y‐z translation stage. The spontaneous injection method was used to achieve picoliter‐scale sample injection from different sample wells. Under the optimized conditions, a 40 μm‐long sample plug (corresponding to 78‐pL plug volume) was obtained in a 50 μm id capillary, which ensured both the high separation speed and high separation efficiency. The performance of the system was demonstrated in the separation of FITC‐labeled amino acids with LIF detection. Five FITC‐labeled amino acids including arginine, phenylalanine, glycine, glutamic acid, and asparagine were separated within 15 s with an effective separation length of 1.5 cm. The separation efficiency ranged from 7.96 × 105/m to 1.12 × 106 /m (corresponding to 1.26–0.89 μm plate heights). The repeatability of the peak heights calibrated with an inner standard for different sample wells was 2.4 and 2.7% (n = 20) for arginine and phenylalanine, respectively. The present system was also applied in consecutive separations of 20 different samples of FITC‐labeled amino acids with a whole separation time of less than 6 min.  相似文献   

18.
A novel Hadamard transform-gas chromatography/mass spectrometry (HT-GC/MS) system equipped with on-line sample collection systems is described. A Hadamard-injector was successfully designed and then coupled with an on-line adsorption/desorption system for detecting volatile organic compounds (VOCs) and a supercritical fluid extraction (SFE) system, respectively, by HT-GC/MS. Six VOCs and three pesticides were used as model compounds. In the former case, an activated-charcoal trap was used to trap VOCs from the indoor air. After 10 L of indoor air had passed through the trap, the condensed components were heated and simultaneously injected into the GC column through the Hadamard-injector, based on Hadamard codes. In a second experiment, a sample of rice was spiked with three types of pesticides and the sample then extracted using a commercially available supercritical fluid extractor. After extraction, the extracted components were transferred to a holding tank and simultaneously injected into the GC column also using the Hadamard-injector. The findings show that, in both cases, the combination of on-line sample collection methods and the use of the Hadamard transform resulted in improved sensitivity and detection. Compared to the single injection used in most GC/MS systems, the signal-to-noise (S/N) ratios were substantially improved after inverse Hadamard transformation of the encoded chromatogram.  相似文献   

19.
CZE with UV-absorption detection has been used for the separation and determination of enkephalin-related peptides. The experimental conditions, such as pH and concentration of running buffer, applied voltage, injection method, and time, were investigated in detail. Excellent separation efficiency could be obtained for ten enkephalin-related peptides with a 50 microm (ID) x 58 cm capillary using sodium dihydrogen phosphate as the running buffer (pH 3.11) when 20 kV of applied voltage was used. The concentration detection limits were found to be in the range of 0.31-1.94 microg/mL (defined as S/N = 3). The proposed method has been applied to analyze the spiked cerebrospinal fluid (CSF) sample, and the results showed that CZE is a powerful technique for separation and detection of the above biological peptides.  相似文献   

20.
Here, we report the first utilization of Hadamard transform CE (HTCE), a high-sensitivity, multiplexed CE technique, with photolytic optical gating sample injection of caged fluorescent labels for the detection of biologically important amines. Previous implementations of HTCE have relied upon photobleaching optical gating sample injection of fluorescent dyes. Photolysis of caged fluorescent labels reduces the fluorescence background, providing marked enhancements in sensitivity compared to photobleaching. Application of fast Hadamard transform CE (fHTCE) for fluorescein-based dyes yields a ten-fold higher sensitivity for photolytic injections compared to photobleaching injections, due primarily to the reduced fluorescent background provided by caged fluorescent dyes. Detection limits as low as 5 pM (ca. 18 molecules per injection event) were obtained with on-column LIF detection using fHTCE in less than 25 s, with the capacity for continuous, online separations. Detection limits for glutamate and aspartate below 150 pM (1-2 amol/injection event) were obtained using photolytic sample injection, with separation efficiencies exceeding 1 x 10(6) plates/m and total multiplexed separation times as low as 8 s. These results strongly support the feasibility of this approach for high-sensitivity dynamic chemical monitoring applications.  相似文献   