首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In glass/poly(dimethylsiloxane) (PDMS) hybrid microfluidic chips, two different fabrication approaches are used: photolithographic or solid ink molds, or cast-and-peel methods. In the latter, a thin slab of PDMS is laid down and fluid channels are cut manually or by machine. The cast-and-peel approach has been used successfully for low-shear culture devices, among other applications. The main drawback, not reported to date, of cast-and-peel methods is that removal of PDMS (exposing the glass substrate) results in nanoscopic domains of PDMS still attached to the surface. This residual PDMS is not observable by eye, but affects the hydrophobicity of the device. Using contact angle measurement, atomic force and fluorescence microscopy, the changes in glass surfaces from the cast-and-peel technique were elucidated. This study demonstrates the enhanced protein (NeutrAvidin) adsorption on PDMS treated glass surfaces, and the potential influence of altered glass properties on microfluidic applications has been discussed as well.  相似文献   

2.
Yuen PK  Su H  Goral VN  Fink KA 《Lab on a chip》2011,11(8):1541-1544
This technical note presents a fabrication method and applications of three-dimensional (3D) interconnected microporous poly(dimethylsiloxane) (PDMS) microfluidic devices. Based on soft lithography, the microporous PDMS microfluidic devices were fabricated by molding a mixture of PDMS pre-polymer and sugar particles in a microstructured mold. After curing and demolding, the sugar particles were dissolved and washed away from the microstructured PDMS replica revealing 3D interconnected microporous structures. Other than introducing microporous structures into the PDMS replica, different sizes of sugar particles can be used to alter the surface wettability of the microporous PDMS replica. Oxygen plasma assisted bonding was used to enclose the microstructured microporous PDMS replica using a non-porous PDMS with inlet and outlet holes. A gas absorption reaction using carbon dioxide (CO(2)) gas acidified water was used to demonstrate the advantages and potential applications of the microporous PDMS microfluidic devices. We demonstrated that the acidification rate in the microporous PDMS microfluidic device was approximately 10 times faster than the non-porous PDMS microfluidic device under similar experimental conditions. The microporous PDMS microfluidic devices can also be used in cell culture applications where gas perfusion can improve cell survival and functions.  相似文献   

3.
Plastics are increasingly being used for the fabrication of Lab-on-a-Chip devices due to the variety of beneficial material properties, affordable cost, and straightforward fabrication methods available from a range of different types of plastics. Rapid prototyping of polydimethylsiloxane (PDMS) devices has become a well-known process for the quick and easy fabrication of microfluidic devices in the research laboratory; however, PDMS is not always an appropriate material for every application. This paper describes the fabrication of thermoset polyester microfluidic devices and masters for hot embossing using replica molding techniques. Rapid prototyped PDMS molds are convienently used for the production of non-PDMS polymeric devices. The recessed features in the cast polyester can be bonded to a second polyester piece to form an enclosed microchannel. Thermoset polyester can withstand moderate amounts of pressure and elevated temperature; therefore, the cast polyester piece also can be used as a master for embossing polymethylmethacrylate (PMMA) microfluidic systems. Examples of enclosed polyester and PMMA microchannels are presented, and we discuss the electroosmotic properties of both types of channels, which are important for analytical applications such as capillary electrophoresis.  相似文献   

4.
Kim JY  deMello AJ  Chang SI  Hong J  O'Hare D 《Lab on a chip》2011,11(23):4108-4112
The vast majority of droplet-based microfluidic devices are made from polydimethylsiloxane (PDMS). Unfortunately PDMS is not suitable for high frequency droplet generation at high operating pressure due to its low shear modulus. In this paper, we report the fabrication and testing of microfluidic devices using thermoset polyester (TPE). The optical characteristics of the fabricated devices were assessed and substrate resistance to pressure also investigated. TPE devices bonded using an O(2) plasma treated PET substrate at 76 °C were shown to function efficiently at pressures up to 18 MPa. TPE material retains many of the attractive features of PDMS such as ease of fabrication but significantly, has superior mechanical properties. The improved resistance of TPE to high pressures enabled investigation of high frequency droplet generation as a function of a wide range of flow-rates with three different oils as continuous phase.  相似文献   

5.
A current problem in microfluidics is that poly(dimethylsiloxane) (PDMS), used to fabricate many microfluidic devices, is not compatible with most organic solvents. Fluorinated compounds are more chemically robust than PDMS but, historically, it has been nearly impossible to construct valves out of them by multilayer soft lithography (MSL) due to the difficulty of bonding layers made of "non-stick" fluoropolymers necessary to create traditional microfluidic valves. With our new three-dimensional (3D) valve design we can fabricate microfluidic devices from fluorinated compounds in a single monolithic layer that is resistant to most organic solvents with minimal swelling. This paper describes the design and development of 3D microfluidic valves by molding of a perfluoropolyether, termed Sifel, onto printed wax molds. The fabrication of Sifel-based microfluidic devices using this technique has great potential in chemical synthesis and analysis.  相似文献   

6.
Nock V  Blaikie RJ  David T 《Lab on a chip》2008,8(8):1300-1307
This paper describes a process for the layer-by-layer fabrication and integration of luminescent dye-based optical oxygen sensors into microfluidic devices. Application of oxygen-sensitive platinum(ii) octaethylporphyrin ketone fluorescent dye dissolved in polystyrene onto glass substrates by spin-coating was studied. Soft lithography with polydimethylsiloxane (PDMS) stamps and reactive ion etching in oxygen plasma were used to produce sensor patterns with a minimum feature size of 25 microm. Sensors patterns were integrated into a PDMS microfluidic device by plasma bonding. No degradation of the sensor response as a result of the lithography and pattern-transfer processes was detected. Gaseous and dissolved oxygen (DO) detection was characterised using fluorescence microscopy. The intensity signal ratio of the sensor films was found to increase almost two-fold from 3.6 to 6.8 by reducing film thickness from 1.3 microm to 0.6 microm. Calibration of DO measurement showed linear Stern-Volmer behaviour that was constant for flow rates from 0.5 to 2 mL min(-1). The calibrated sensors were subsequently used to demonstrate laterally resolved detection of oxygen inside a microfluidic channel. The fabrication process provides a novel, easy to use method for the repeatable integration of optical oxygen sensors into cell-culture and lab-on-a-chip devices.  相似文献   

7.
Li CW  Cheung CN  Yang J  Tzang CH  Yang M 《The Analyst》2003,128(9):1137-1142
We have developed a method for fabricating microfluidic devices with multi-height structures using single step photolithography. The whole fabrication process is executed by conventional printed circuit board (PCB) technology without the need of having access to clean room facilities. Specifically designed "windows" and "rims" architectures were printed on films that were used as photomasks. Different levels of protruding features on the PCB master were produced by exposing a photomask followed by chemical wet etching. Poly(dimethylsiloxane) (PDMS) was then moulded against the positive relief master to generate microfluidic structures. In this report, we described the fabrication of a microfluidic device featured with a multi-height "sandbag" structure for particle entrapment and peripheral microchannels. Controlled immobilization of biological cells and immunocytochemcial staining assays were performed to demonstrate the applicability of the microfluidic device for cellular analysis. The integrity of the microdevice remained stable under applied pressure, indicating the robustness of the elastic PDMS structures for analytical operation. The simple microfabrication process requires only low-cost materials and minimal specialized equipment and can reproducibly produce mask lines of about 20 microm in width, which is sufficient for most microfluidic applications.  相似文献   

8.
We report the fabrication of high quality monolithically integrated optical long-pass filters, for use in disposable diagnostic microchips. The filters were prepared by incorporating dye molecules directly into the microfluidic chip substrate, thereby providing a fully integrated solution that removes the usual need for discrete optical filters. In brief, lysochrome dyes were added to a poly(dimethylsiloxane) (PDMS) monomer prior to moulding of the microchip from a structured SU-8 master. Optimum results were obtained using 1 mm layers of PDMS doped with 1200 microg mL(-1) Sudan II, which resulted in less than 0.01% transmittance below 500 nm (OD 4), >80% above 570 nm, and negligible autofluorescence. These spectral characteristics compare favourably with commercially available Schott-glass long-pass filters, indicating that high quality optical filters can be straightforwardly integrated into the form of PDMS microfluidic chips. The filters were found to be robust in use, showing only slight degradation after extended illumination and negligible dye leaching after prolonged exposure to aqueous solutions. The provision of low cost high quality integrated filters represents a key step towards the development of high-sensitivity disposable microfluidic devices for point-of-care diagnostics.  相似文献   

9.
In this study, we applied photo-induced graft polymerization to micropatterned surface modification of polydimethylsiloxane (PDMS) with poly(ethylene glycol). Two types of monomers, polyethylene glycol monoacrylate (PEGMA) and polyethylene glycol diacrylate (PEGDA), were tested for surface modification of PDMS. Changes in the surface hydrophilicity and surface element composition were characterized by contact angle measurement and electron spectroscopy for chemical analysis. The PEGMA-grafted PDMS surfaces gradually lost their hydrophilicity within two weeks. In contrast, the PEGDA-grafted PDMS surface maintained stable hydrophilic characteristics for more than two months. Micropatterned protein adsorption and micropatterned cell adhesion were successfully demonstrated using PEGDA-micropatterned PDMS surfaces, which were prepared by photo-induced graft polymerization using photomasks. The PEGDA-grafted PDMS exhibited useful characteristics for microfluidic devices (e.g. hydrophilicity, low protein adsorption, and low cell attachment). The technique presented in this study will be useful for surface modification of various research tools and devices.  相似文献   

10.
Control of surface properties in microfluidic systems is an indispensable prerequisite for successful bioanalytical applications. Poly(dimethylsiloxane) (PDMS) microfluidic devices are hampered from unwanted adsorption of biomolecules and lack of methods to control electroosmotic flow (EOF). In this paper, we propose different strategies to coat PDMS surfaces with poly(oxyethylene) (POE) molecules of varying chain lengths. The native PDMS surface is pretreated by exposure to UV irradiation or to an oxygen plasma, and the covalent linkage of POE-silanes as well as physical adsorption of a triblock-copolymer (F108) are studied. Contact angle measurements and atomic force microscopy (AFM) imaging revealed homogeneous attachment of POE-silanes and F108 to the PDMS surfaces. In the case of F108, different adsorption mechanisms to hydrophilic and hydrophobic PDMS are discussed. Determination of the electroosmotic mobilities of these coatings in PDMS microchannels prove their use for electrokinetic applications in which EOF reduction is inevitable and protein adsorption has to be suppressed.  相似文献   

11.
Polyurethane (PU) was modified using isocyanate chemistry to graft polyethylene oxide (PEO) of various molecular weights (range 300-4600). An antithrombin-heparin (ATH) covalent complex was subsequently attached to the free PEO chain ends, which had been functionalized with N-hydroxysuccinimide (NHS) groups. Surfaces were characterized by water contact angle and X-ray photoelectron spectroscopy (XPS) to confirm the modifications. Adsorption of fibrinogen from buffer was found to decrease by ~80% for the PEO-modified surfaces compared to the unmodified PU. The surfaces with ATH attached to the distal chain end of the grafted PEO were equally protein resistant, and when the data were normalized to the ATH surface density, PEO in the lower MW range showed greater protein resistance. Western blots of proteins eluted from the surfaces after plasma contact confirmed these trends. The uptake of ATH on the PEO-modified surfaces was greatest for the PEO of lower MW (300 and 600), and antithrombin binding from plasma (an indicator of heparin anticoagulant activity) was highest for these same surfaces. The PEO-ATH- and PEO-modified surfaces also showed low platelet adhesion from flowing whole blood. It is concluded that for the PEO-ATH surfaces, PEO in the low MW range, specifically MW 600, may be optimal for achieving an appropriate balance between resistance to nonspecific protein adsorption and the ability to take up ATH and bind antithrombin in subsequent blood contact.  相似文献   

12.
We demonstrate a rapid fabrication procedure for solvent-resistant microfluidic devices based on the perfluoropolyether (PFPE) SIFEL. We carefully modified the poly-dimethylsiloxane (PDMS) micromolding procedure, such that it can still be executed using the standard facilities for PDMS devices. Most importantly, devices with a thin SIFEL layer for the patterned channels and a PDMS support layer on top offered the best of two worlds in terms of chemical and mechanical stability during fabrication and use. Tests revealed that these devices overcome two important drawbacks of PDMS devices: (i) incompatibility with almost all non-aqueous solvents, and (ii) leaching of oligomer into solution. The potential of our device is shown by performing a relevant organic synthesis reaction with aggressive reactants and solvents. PFPE-PDMS devices will greatly expand the application window of micromolded devices.  相似文献   

13.
Surface modifications of microfluidic devices are of essential importance for successful bioanalytical applications. Here, we investigate three different coatings for quartz and poly(dimethylsiloxane) (PDMS) surfaces. We employed a triblock copolymer with trade name F108, poly(l-lysine)-g-poly(ethylene glycol) (PLL-PEG), as well as the hybrid coating n-dodecyl-β-d-maltoside and methyl cellulose (DDM/MC). The impact of these coatings was characterized by measuring the electroosmotic flow (EOF), contact angle, and prevention of protein adsorption. Furthermore, we investigated the influence of static coatings, i.e., the incubation with the coating agent prior to measurements, and dynamic coatings, where the coating agent was present during the measurement. We found that all coatings on PDMS as well as quartz reduced EOF, increased reproducibility of EOF, reduced protein adsorption, and improved the wettability of the surfaces. Among the coating strategies tested, the dynamic coatings with DDM/MC and F108 demonstrated maximal reduction of EOF and protein adsorption and simultaneously best long-term stability concerning EOF. For PLL-PEG, a reversal in the EOF direction was observed. Interestingly, the static surface coating strategy with F108 proved to be as effective to prevent protein adsorption as dynamic coating with this block copolymer. These findings will allow optimized parameter choices for coating strategies on PDMS and quartz microfluidic devices in which control of EOF and reduced biofouling are indispensable.  相似文献   

14.
Components for integrated poly(dimethylsiloxane) microfluidic systems   总被引:11,自引:0,他引:11  
This review describes the design and fabrication of microfluidic systems in poly(dimethylsiloxane) (PDMS). PDMS is a soft polymer with attractive physical and chemical properties: elasticity, optical transparency, flexible surface chemistry, low permeability to water, and low electrical conductivity. Soft lithography makes fabrication of microfluidic systems in PDMS particularly easy. Integration of components, and interfacing of devices with the user, is also convenient and simpler in PDMS than in systems made in hard materials. Fabrication of both single and multilayer microfluidic systems is straightforward in PDMS. Several components are described in detail: a passive chaotic mixer, pneumatically actuated switches and valves, a magnetic filter, functional membranes, and optical components.  相似文献   

15.
A plastic microfluidic system, containing porous poly(vinylidene fluoride) (PVDF) membranes adsorbed with bovine serum albumin (BSA), is demonstrated for high resolution chiral separation of racemic tryptophan and thiopental mixtures. Microfluidic networks on poly(dimethylsiloxane) (PDMS) substrates are fabricated by capillary molding technique. This miniaturized chiral separation system consists of two layers of PVDF membranes which are sandwiched between two PDMS slabs containing microchannels facing the membranes. On-line adsorption of BSA onto the membranes is employed for the preparation of chiral stationary phase and the evaluation of solution conditions in an effort to achieve maximum protein adsorption. Variations in the mobile phase conditions, including solution pH and ammonium sulfate concentration, are studied for their effects on chiral separation. Based on the large surface area to volume ratio of porous membrane media, adsorbed BSA onto the PVDF membranes enables high resolution separation of racemic mixtures with sample consumption of sub-nanogram or less in the integrated microfluidic networks. In addition, the membrane pore diameter in the submicron range eliminates the constraints of diffusional mass-transfer resistance during protein adsorption and chiral chromatographic processes.  相似文献   

16.
Polydimethylsiloxane (PDMS) based microfluidic devices have found increasing utility for electrophoretic and electrokinetic assays because of their ease of fabrication using replica molding. However, the fabrication of high-resolution molds for replica molding still requires the resource-intensive and time-consuming photolithography process, which precludes quick design iterations and device optimization. We here demonstrate a low-cost, rapid microfabrication process, based on electrohydrodynamic jet printing (EJP), for fabricating non-sacrificial master molds for replica molding of PDMS microfluidic devices. The method is based on the precise deposition of an electrically stretched polymeric solution of polycaprolactone in acetic acid on a silicon wafer placed on a computer-controlled motion stage. This process offers the high-resolution (order 10  μ $\umu$ m) capability of photolithography and rapid prototyping capability of inkjet printing to print high-resolution templates for elastomeric microfluidic devices within a few minutes. Through proper selection of the operating parameters such as solution flow rate, applied electric field, and stage speed, we demonstrate microfabrication of intricate master molds and corresponding PDMS microfluidic devices for electrokinetic applications. We demonstrate the utility of the fabricated PDMS microchips for nonlinear electrokinetic processes such as electrokinetic instability and controlled sample splitting in ITP. The ability to rapid prototype customized reusable master molds with order 10  μ $\umu$ m resolution within a few minutes can help in designing and optimizing microfluidic devices for various electrokinetic applications.  相似文献   

17.
PDMS is one of the most common materials used for the flow delivery in the microfluidics chips, since it is clear, inert, nontoxic, and nonflammable. Its inexpensiveness, straightforward fabrication, and biological compatibility have made it a favorite material in the exploratory stages of the bio‐microfluidic devices. If small footprint assays want to be performed while keeping the throughput, high pressure‐rated channels should be used, but PDMS flexibility causes an important issue since it can generate a large variation of microchannel geometry. In this work, a novel fabrication technique based on the prevention of PDMS deformation is developed. A photo‐sensible thiolene resin (Norland Optical Adhesive 63, NOA 63) is used to create a rigid coating layer over the stiff PDMS micropillar array, which significantly reduces the pressure‐induced shape changes. This method uses the exact same soft lithography manufacturing equipment. The verification of the presented technique was investigated experimentally and numerically and the manufactured samples showed a deformation 70% lower than PDMS conventional samples.  相似文献   

18.
Multifunctional envelope-type gene delivery nanodevices (MENDs) are promising non-viral vectors for gene therapy. Though MENDs remain strong in prolonged exposure to blood circulation, have low immunogenic response, and are suitable for gene targeting, their fabrication requires labor-intensive processes. In this work, a novel approach has been developed for rapid fabrication of MENDs by a touch-and-go lipid wrapping technique in a polydimethylsiloxane (PDMS)/glass microfluidic device. The MEND was fabricated on a glass substrate by introduction of a condensed plasmid DNA core into microfluidic channels that have multiple lipid bilayer films. The principle of the MEND fabrication in the microfluidic channels is based on electrostatic interaction between the condensed plasmid DNA cores and the coated lipid bilayer films. The constructed MEND was collected off-chip and characterized by dynamic light scattering. The MEND was constructed within 5 min with a narrow size distribution centered around 200 nm diameter particles. The size of the MEND showed strong dependence on flow velocity of the condensed plasmid DNA core in the microfluidic channels, and thus, could be controlled to provide the optimal size for medical applications. This approach was also proved possible for fabrication of a MEND in multiple channels at the same time. This on-chip fabrication of the MEND was very simple, rapid, convenient, and cost-effective compared with conventional methods. Our results strongly indicated that MENDs fabricated with our microfluidic device have a good potential for medical use. Moreover, MENDs fabricated by this microfluidic device have a great potential for clinical use because the devices are autoclavable and all the fabrication steps can be completed inside closed microfluidic channels without any external contamination.  相似文献   

19.
Thermoset polyester (TPE) microfluidic devices were previously developed as an alternative to poly(dimethylsiloxane) (PDMS) devices, fabricated similarly by replica molding, yet offering stable surface properties and good chemical compatibility with some organics that are incompatible with PDMS. This paper describes a number of improvements in the fabrication of TPE chips. Specifically, we describe methods to form TPE devices with a thin bottom layer for use with high numerical aperture (NA) objectives for sensitive fluorescence detection and optical manipulation. We also describe plasma-bonding of TPE to glass to create hybrid TPE-glass devices. We further present a simple master-pretreatment method to replace our original technique that required the use of specialized equipment.  相似文献   

20.
Wu H  Zhai J  Tian Y  Lu H  Wang X  Jia W  Liu B  Yang P  Xu Y  Wang H 《Lab on a chip》2004,4(6):588-597
The design and characterization of two kinds of poly(dimethylsiloxane)(PDMS) microfluidic enzymatic-reactors along with their analytical utility coupled to MALDI TOF and ESI MS were reported. Microfluidic devices integrated with microchannel and stainless steel tubing (SST) was fabricated using a PDMS casting technique, and was used for the preparation of the enzymatic-reactor. The chemical modification was performed by introducing carboxyl groups to PDMS surface based on ultraviolet graft polymerization of acrylic acid. The covalent and physical immobilization of trypsin was carried out with the use of the activation reagents 1-ethyl-3-(3-dimethyl aminopropyl)carbodiimide(EDC)/N-hydroxysuccinimide (NHS) and a coupling reagent poly(diallyldimethylammonium chloride)(PDDA), respectively. The properties and success of processes of trypsin immobilization were investigated by measuring contact angle, infrared absorption by attenuated total reflection spectra, AFM imaging and electropherograms. An innovative feature of the microfluidic enzymatic-reactors is the feasibility of performing on-line protein analysis by embedded SST electrode and replaceable tip. The lab-made devices provide an excellent extent of digestion of several model proteins even at the fast flow rate of 3.5 microL min(-1) for the EDC/NHS-made device and 0.8 microL min(-1) for the PDDA-made device, which afford very short residence times of 5 s and 20 s, respectively. In addition, the lab-made devices are less susceptive to memory effect and can be used for at least 50 runs in one week without noticeable loss of activity. Moreover, the degraded PDDA-made device can be regenerated by simple treatment of a HCl solution. These features are the most required for microfluidic devices used for protein analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏