首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This paper describes a new voltammetric procedure for the inorganic speciation of As(III) and As(V) in water samples. The procedure is based on the chemical reduction of arsenate [As(V)] to arsenite [As(III)] followed by the voltammetric determination of total arsenic as As(III) at the hanging mercury drop electrode (HMDE) by adsorptive cathodic stripping voltammetry (AdCSV) in the presence of sodium diethyl dithiocarbamate (SDDC). The reduction step involved the reaction with a mixture of Na2S2O5 and Na2S2O3 in the concentrations 2.5 and 0.5 mg mL?1, respectively, and the sample heating at 80 °C for 45 min. The linear range for the determination of total arsenic as As(III) in the presence of SDDC was between 5 and 150 μg L?1 for a deposition time of 60 s (r=0.992). A detection limit of 1.05 μg L?1 for total As was calculated for the method in water samples using a deposition time of 60 s. The detection limits of 4.2 μg L?1 and 15.0 μg L?1 for total As in seawater and dialysis concentrates, respectively, were calculated using a deposition time of 60 s. The relative standard deviations calculated were 2.5 and 4.0% for five measurements of 20 μg L?1 As(V) as As(III) in water and dialysis concentrates, respectively, after chemical reduction under optimized conditions. The method was applied for the determination of As(III) and total As in samples of dialysis water, mineral water, seawater and dialysis concentrates. Recovery values between 86.0 and 104.0% for As(III) and As(V) added to the samples prove the satisfactory accuracy and applicability of the procedure for the arsenic monitoring.  相似文献   

2.
A new method for the determination of inorganic arsenic species (As(III) and As(V)) was developed by dispersive liquid-liquid microextraction (DLLME) separation and graphite furnace atomic absorption spectrometry (GFAAS) detection. In the pH range of 3–5, As(III) complexes with ammonium pyrrolidinedithiocarbamate (APDC) and then can be extracted into carbon tetrachloride droplets formed by injecting the binary solution of carbon tetrachloride (extraction solvent) and methanol (dispersive solvent) into the sample solution. As(V) is not extracted at the same pH conditions and remained in the aqueous phase. After extraction and phase separation by centrifugation, the enriched As(III) in the sedimented phase was determined by GFAAS. Total inorganic arsenic was determined after reduction of As(V) to As(III) with sodium thiosulfate and potassium iodide, and As(V) was calculated by difference. Under optimized conditions, the detection limits of this method for As(III) were 36 ng L?1 with an enrichment factor of 45, and the relative standard deviation (R.S.D.%) was 3.1% (n?=?11, c?=?1.0 ng mL?1). The method has been applied to the speciation of As(III) and As(V) in natural water samples with satisfactory results.  相似文献   

3.

We describe a simple and efficient method for solid phase extraction and speciation of trace quantities of arsenic. It is based on the use of functionalized aluminum oxide nanoparticles and does not require any oxidation or reduction steps. The experimental parameters affecting extraction and quantitation were optimized using fractional factorial design methods. Adsorbed arsenic was eluted from the sorbent with 1 M hydrochloric acid and determined by graphite furnace atomic absorption spectrometry. Preconcentration factors up to 750 were achieved depending on the sample volume. Studies on potential interferences by various anions and cations showed the method to be highly selective. Under optimum conditions, the calibration plots are linear in the 5.0 to 280 ng L−1 and 8.0 to 260 ng L−1 concentration ranges for As(III) and total arsenic, respectively. The detection limits (calculated for S/N ratios of 3) are 1.81 and 1.97 ng L−1 for As(III) and total arsenic, respectively. The method was successfully applied to the determination and speciation of arsenic in (spiked) environmental, food and biological samples and gave good recoveries. The method was validated using a certified geological reference material.

Novel functionalized Al2O3 nanoparticles were synthesized and used for speciation and determination of arsenic in different samples. The experimental variables were optimized using fractional factorial design that can save time and operational costs.

  相似文献   

4.
A novel arsine generator glass assembly is constructed and reported for the spectrophotometric determination and speciation of arsenic in real samples. In an arsine generator, sodium borohydride is added dropwise to the acidic sample solution and arsine thus formed is reacted with silver diethyldithiocarbamate (Ag‐DDTC) ‐ Tritron‐X (TX‐100) solution in pyridine to form a red coloured complex. The complex showed the absorption maximum at λmax 540 nm. The molar absorptivity of the method was found to be (1.55) × 104 L mole?1 cm?1 at this wavelength. The presence of non‐ionic surfactant, i.e. TX‐100 in the Ag‐DDTC solution, makes the method ≈ 3 times more sensitive than the conventional Ag‐DDTC method. Beer's law is obeyed in the concentration range of 0.05–2.80 mg L?1 of arsenic. The detection limit of the method was calculated to be 20 μg L?1 As. Speciation of arsenite from other forms of arsenic in sample solutions was carried out by extraction of arsenite with Pb‐DDTC in chloroform, followed by spectrophotometric determination. After arsenite separation the sample is used for the arsenate determination. Total arsenic was determined by acid decomposition of the same sample. The speciation data were found to be comparable (±2%) with ICP‐MS, with better precision (< 1%). The method has been successfully applied for the speciation of arsenic in drinking water and dust samples of arsenic affecting the Rajnandgaon district of Chhattisgarh, India, and urine and blood samples of patients with arsenical diseases. Concentration of total arsenic in tube‐well water of this area was 3–6 times more than the permissible limit. Dust samples contained less amounts of arsenic than the ground water.  相似文献   

5.
The determination of total arsenic through As(V) anodic stripping voltammetry (ASV) is, in some cases, preferable over As(III) ASV. The As(V) ASV procedure has no chemical reduction step from As(V) into As(III), which results in decreased analysis time and no contamination from reducting reagents. A simple and reliable procedure of As(V) determination is proposed. Anodic stripping determination of trace As(V) at gold microelectrode ensembles in diluted HCl solution in the presence of dissolved oxygen is shown. The electrode is based on a carbon black (30%)–polyethylene composite. The sensor was prepared by gold electrodeposition on the surface of the composite electrode. The given sensor is cheap, reliable and stable, especially when electrochemical activation is employed. The experimental parameters for the electrochemical determination were optimized, namely 0.005?M HCl as the background electrolyte, the deposition potential ?2.2?V (versus Ag/AgCl in 1?M KCl) and 180?mV?s?1 linear scan rate. Calibration curves were obtained and were linear in [As(V)] over the 1.5–45?µg?L?1 range, with a LOD of 0.5?µg?L?1. The effect of common interfering species is studied. The electrochemical behaviour of As(III) form is studied in the same experimental conditions. It was found that As(III) is deposited at lower potentials (starting at ?0.6?V) and the sensitivity of As(III) detection is higher, but dependant on the presence of dissolved oxygen. The speciation of inorganic forms of arsenic is discussed.  相似文献   

6.
A sensitive, reliable, simple and rapid analytical method was developed for the determination of arsenite [As(III)], arsenate [As(V)] and arsenobetaine (AsB) species using ion chromatography combined with inductively coupled plasma-mass spectrometry (IC-ICP-MS). Inorganic and organic arsenic species were separated with an anion exchange column (Dionex AS9) and a 50 mM sodium bicarbonate mobile phase (pH 10) at a flow rate of 1.0 mL min?1. %RSD values were found to be lower than 5.1% for all arsenic species. The limits of detection (LOD) obtained for As(III), As(V) and AsB were 16.5 ng L?1, 14.1 ng L?1 and 6.2 ng L?1, respectively. The developed analytical method was tested using AsB certified reference material (NMIJ CRM 7901-a), and spring water certified reference material (UME CRM 1201) for accuracy check. This method was applied for the quantitative determination of arsenic species in different water samples and chicken samples as a solid matrix.  相似文献   

7.
《Analytical letters》2012,45(13):2207-2216
Abstract

A simple and selective spectrophotometric method has been developed for the determination of trace amounts of arsenic using azure B as a chromogenic reagent. The proposed method is based on the reaction of arsenic(III) with potassium iodate in acid medium to liberate iodine. The liberated iodine bleaches the violet color of azure B and is measured at 644 nm. This decrease in absorbance is directly proportional to the As(III) concentration, and Beer's law is obeyed in the range 0.2–10 µg ml?1 of As(III). The molar absorptivity, Sandell's sensitivity, detection limit, and quantitation limit of the method were found to be 1.12×104 l mol?1cm?1, 6.71×10?3 µg cm?2, 0.02 µg ml?1 and 0.08 µg ml?1, respectively. The optimum reaction conditions and other analytical parameters were evaluated. The proposed method has been successfully applied for the determination of arsenic in various environmental and biological samples.  相似文献   

8.
A new method was developed for the speciation of inorganic arsenic in environmental water by using selective magnetic solid-phase extraction followed by inductively coupled plasma mass spectrometry. It is found that As(V) selectively adsorbed on amino-modified silica-coated magnetic nanoparticles (MNPs) in the pH range from 3 to 8, while As(III) is not be retained. The As(V)-loaded MNPs can be separated easily from the aqueous sample solution by simply applying an external magnetic field. The adsorbed As(V) was quantitatively recovered from the MNPs using using 1 M nitric acid. Total inorganic As was extracted after the permanganate oxidation of As(III) to As(V). Parameters affecting the separation were investigated systematically, and the optimal separation conditions were established. Under the optimal conditions, the limit of detection is 0.21 ng L?1, and the precision is 6.8% (at 10 ng L?1, for n?=?7). The method was applied to the speciation of inorganic arsenic in environmental water of tobacco growing area.
Figure
A new kind of silica-coated magnetic nanoparticles (SCMNPs) modified with AAPTS was synthesized and employed as magnetic solid phase extraction adsorbent for ICP-MS speciation of inorganicAs in environmental water  相似文献   

9.
《Analytical letters》2012,45(17):2493-2507
In this work, an improved hydride-generation atomic fluorescence spectrometry (HG-AFS) method for the determination of total arsenic (As) in wastewater and sewage sludge samples was applied. The samples were digested completely with mixtures of HNO3 and HClO4. Analytical conditions were studied and optimized through uniform experimental design U*10(108) combined with a single factor test. A mathematical model was established, and a quadratic polynomial stepwise regression analysis by using the DPS software was employed to obtain the factors that impact the fluorescence intensity. This technique is then combined with a single factor test. The optimized experimental conditions were obtained as follows: PMT voltage was 305 V, lamp current was 70 mA, KBH4 concentration was 2.0% (m/v), carrier liquid (HCl) concentration was 5% (v/v), carrier gas (Ar) flow rate was 300 mL min?1, and reaction acidity was 10% (v/v) HCl. The pre-reduction of all forms of As to As(III) was performed by using a mixed solution of 1% thiourea and 1% ascorbic acid. The content of total As was determined under the optimized experimental conditions. The detection limits for total As in wastewater and sewage sludge were 0.09 µg L?1 and 0.01 mg kg?1, respectively. The linear ranges were 0.24–100 µg L?1, and the recovery was 91.0–102.0%. The relative standard deviation (RSD, n = 5) for eleven replicate measurements of the certified reference materials containing 60.6 ± 4.2 µg L?1 As (certified sample of water) and 10.7 ± 0.8 mg kg?1 As (certified sample of soil) were 3.1% and 1.6%, respectively. The proposed method was validated by the analysis of certified reference materials and was successfully applied to the determination of total As in real samples of wastewater and sewage sludge with satisfactory results.  相似文献   

10.
Orthogonal array design was used to optimize arsenic speciation in drinking water in contact with materials by dispersive liquid–liquid microextraction followed by graphite furnace atomic absorption spectrometry. Arsenic speciation was achieved by the formation of an arsenic(III) hydrophobic complex with a new chelating agent, 1,2,6-hexanetriol trithioglycolate, at neutral pH. The complex was extracted into the organic phase, while arsenic(V) remained in aqueous solution. The concentration of As(V) was determined by subtracting As(III) from the total arsenic following the reduction of As(V) to As(III) by L-cysteine. Orthogonal array design with OA16 (44) and OA9 (33) matrices was used to optimize the efficiency of dispersive liquid–liquid microextraction and the reduction of As(V) to As(III), respectively. Under the optimal conditions, the detection limit was 0.03?µg?L?1 for As(III) and the relative standard deviation was 5.9% with an enhancement factor of 87. The calibration curve was linear from 0.19 to 3.0?µg?L?1 with a correlation coefficient of 0.9996. The developed method was used for arsenic speciation in solutions of drinking water that contacted materials. The recoveries of fortified samples were in an acceptable range from 92.0 to 113.3%.  相似文献   

11.
A method was developed for the determination of arsenite [As(III)] and arsenate [As(V)] in water samples using flow injection online sorption coupled with hydride generation atomic fluorescence spectrometry (HG-AFS) using a cigarette filter as the sorbent. Selective determination of As(III) was achieved through online formation and retention of the pyrrolidine dithiocarbamate arsenic complex on the cigarette filter, but As(V) which did not form complexes was discarded. After reducing As(V) to As(III) using L-cysteine, total arsenic was determined by HG-AFS. The concentration of As(V) was calculated by the difference between As(III) and total arsenic. The analytes were eluted from the sorbent using 1.68 mol L?1 HCl. With consumption of 22 mL of the sample solution, the enrichment factor of As(III) was 25.6. The detection limits (3σ/k) and the relative standard deviation for 11 replicate determinations of 1.0 ng mL?1 As(III) were found to be 7.4 pg mL?1 and 2.6%, respectively.  相似文献   

12.
A simple, fast, and sensitive method for speciation and determination of As (III, V) and Hg (II, R) in human blood samples based on ionic liquid-dispersive liquid-liquid microextraction (IL-DLLME) and flow injection hydride generation/cold vapor atomic absorption spectrometry (FI-HG/CV-AAS) has been developed. Tetraethylthiuram disulfide, mixed ionic liquids (hydrophobic and hydrophilic ILs) and acetone were used in the DLLME step as the chelating agent, extraction and dispersive solvents, respectively. Using a microwave assisted-UV system, organic mercury (R-Hg) was converted to Hg(II) and total mercury amount was measured in blood samples by the presented method. Total arsenic content was determined by reducing As(V) to As(III) with potassium iodide and ascorbic acid in a hydrochloric acid solution. Finally, As(V) and R-Hg were determined by mathematically subtracting the As(III) and Hg(II) content from the total arsenic and mercury, respectively. Under optimum conditions, linear range and detection limit (3σ) of 0.1–5.0 µg L?1 and 0.02 µg L?1 for As(III) and 0.15–8.50 µg L?1 and 0.03 µg L?1 for Hg(II) were achieved, respectively, at low RSD values of < 4% (N = 10). The developed method was successfully applied to determine the ultra-trace amounts of arsenic and mercury species in blood samples; the validation of the method was performed using standard reference materials.  相似文献   

13.
Microcolumn packed single-walled carbon nanotubes (SWCNTs) were used as solid phase extraction adsorbent for chromium speciation coupled to inductively coupled plasma mass spectrometry for detection. The effects of the experimental parameters, including pH of the solution, sample flow rate, volume and concentration of eluent, sample volume and interfering ions, on separation and determination of Cr(III) and Cr(VI) were investigated in detail. It was found that Cr(III) was selectively sorbed on the microcolumn packed with SWCNTs in the pH range from 2.0 to 4.0, while Cr(VI) remained in solution. The retained Cr(III) was subsequently eluted with 2.0 mL of 1.2 mol L?1 nitric acid. Under the optimum conditions, the detection limits based on 3σ criterion were 0.01 ng mL?1 and 0.024 ng mL?1 for Cr(III) and Cr(VI), respectively. The relative standard deviations were less than 5.0% (n?=?9, c?=?1.0 ng mL?1). The method was successfully applied to the speciation of chromium in real samples including natural and waste water. The recoveries of spiked samples were higher than 92.5%.  相似文献   

14.
《Analytical letters》2012,45(16):2593-2605
A method was developed for the determination of vitamin B12 based on the enhancement of cobalt (II) on the chemiluminescence (CL) reaction between luminol and percarbonate (powerful source of hydrogen peroxide). The release of cobalt (II) from the vitamin B12 was reached by a simple and fast microwave digestion (20 s microwave digestion time and a mix of nitric acid and hydrogen peroxide). A charge coupled device (CCD) photodetector, directly connected to the cell, coupled with a simple continuous flow system was used to obtain the full spectral characteristics of cobalt (II) catalyzed luminol-percarbonate reaction.

The optima experimental conditions were established: 8.0 m mol L?1 luminol in a 0.075 mol L?1 carbonate buffer (pH 10.0) and 0.15 mol L?1 sodium percarbonate, in addition to others experimental parameters as 0.33 mL s?1 flow rate and 2 s integration time, were the experimental conditions which proportionate the optimum CL emission intensity. The emission data were best fitted with a second-order calibration graph over the cobalt (II) concentration range from 4.00 to 300 µ g L?1 (r2 = 0.9990), with a detection limit of 0.42 µ g L?1. The proposed method was successfully applied to the determination of vitamin B12 in pharmaceuticals.  相似文献   

15.
In the present study, multiwalled carbon nanotubes (MWCNTs) as solid phase extraction sorbent were developed for preconcentration of arsenic(V) species prior to graphite furnace atomic absorption spectrometry (GFAAS) determination. Arsenic(V) was selectively sorbed on the packed column with MWCNTs within a pH 9.5 in the presence of 2-(5-bromo-2-pyridylazo)-5-diethyl amino phenol (5-Br-PADAP). The adsorbed species was then desorbed with 1 mL of 2.0 M HNO3. Experimental parameters including pH, sample volume and flow rate, type, volume and concentration of eluent that influence the recovery of the arsenic(V) species were optimised. Under the optimised conditions, the calibration curve was linear in the range of 0.2–10.0 µg L?1 with detection limit of 0.016 µg L?1. The relative standard deviations (RSD) for seven replicate determinations at 1.0 µg L?1 level of arsenic was 6.69%. The proposed method was successfully applied to the determination of arsenic in water samples and certified reference material (NIST RSM 1643e).  相似文献   

16.
《Analytical letters》2012,45(13):2312-2320
The purpose of this paper is to present a procedure for the simultaneous determination of metalloids: arsenic, antimony, and selenium. Hydride generation was provided in a reaction vessel connected with the atomic absorption spectrometer (AAS) in a fast sequential mode. Two different types of water samples were used while developing the application: seawater and groundwater. The methodology of liquid samples analysis was developed with detection limits of 0.05, 0.03, and 0.06 ng · mL?1 for arsenic, antimony, and selenium, respectively, in 10 mL samples. This methodology was used to determine arsenic, antimony, and selenium in natural water samples.  相似文献   

17.
An inductively coupled plasma atomic emission spectrometric (ICP-AES) method was developed for speciation and simultaneous determination of Cr and As, since these two analytes are commonly determined in various water samples in order to assess their toxicity. The objective of this research was to study the speciation of Cr(III), Cr(VI) in the presence of As(III) and/or As(V) using solid phase extraction (SPE) and ICP-AES. For these measurements, four spectral lines were used for each analyte with the purpose of selecting the most appropriate for each element. Finally with the use for first time of a cation-exchange column filled with benzosulfonic acid and elution with HCl, the speciation in solutions which contained [Cr(III)?+?Cr(VI)?+?As(V)] and [Cr(III)?+?Cr(VI)?+?As(III)] was examined. It was demonstrated that the separation of the two chromium species is almost quantitative and the simultaneous determination of chromium species and total arsenic analytes is possible, with very good performance characteristics. The estimated limits of detection for Cr(III), Cr(VI), As(III) and/or As(V) were 0.9?µg?L?1, 1.1 µg?L?1, 4.7 µg?L?1 and 4.5 µg?L?1 respectively, the calculated relative standard deviations (RSDs) were 3.8%, 4.1%, 5.2% and 5.1% respectively, and finally the accuracy of the methods was estimated using a certified aqueous reference material and found to be 5.6% and 4.8% for Cr(III) and Cr(VI) respectively. The method was applied to the routine analysis of various water samples.  相似文献   

18.
A solid phase extraction (SPE) procedure based on Amberlite IRA 900 resin was developed for speciation and separation of inorganic arsenic species (III, V) and total As in water samples. The As species and total As in eluent solutions were determined by electrothermal atomic absorption spectrometry (ETAAS) using Ni chemical modifier with 1200°C pyrolysis temperature. Experimental parameters such as pH value, sample volume, flow rate, volume and concentration of eluent solution for As(V) were optimised and 98.0 ± 1.9% recovery was found at pH 4.0. Experimental adsorption capacity of the resin for As(V) was investigated and 229.9 mg g1 was found. Under optimised experimental conditions, instrumental parameters such as limit of detection (LOD) and limit of quantification (LOQ) found were 0.126 and 0.420 µg L1, respectively. Interference effects of coexisting ions in the sample matrix on the recovery of As(V) were investigated. Concentration of As(III) was obtained by subtracting As(V) concentration found at pH 4.0 from total As(III + V) found at pH 8.0. The accuracy of the method proposed by using the resin was tested for analysing As species in a waste water standard reference material (SRM, CWW-TM-D) and spiked real water samples with recovery above 95%. The method proposed was also applied to the determinations of As species and total As in underground hot waters and tap water with relative error below 3%.  相似文献   

19.
A speciation procedure for As(III) and As(V) ions in environmental samples has been presented. As(V) was quantitatively recovered on aluminum hydroxide precipitate. After oxidation of As(III) by using dilute KMnO4, the developed coprecipitation was applied to determination of total arsenic. Arsenic(III) was calculated as the difference between the total arsenic content and As(V) content. The determination of arsenic levels was performed by hydride generation atomic absorption spectrometry (HG-AAS). The analytical conditions for the quantitative recoveries of As(V) including pH, amount of aluminum as carrier element and sample volume, etc. on the presented coprecipitation system were investigated. The effects of some alkaline, earth alkaline, metal ions and also some anions were also examined. Preconcentration factor was calculated as 25. The detection limits (LOD) based on three times sigma of the blank (N: 21) for As(V) was 0.012 μg L−1. The satisfactory results for the analysis of arsenic in NIST SRM 2711 Montana soil and LGC 6010 Hard drinking water certified reference materials for the validation of the method was obtained. The presented procedure was successfully applied to real samples including natural waters for arsenic speciation.  相似文献   

20.
《Analytical letters》2012,45(10):1842-1852
A dynamic ultrasound-assisted extraction method using Atomic Absorption and Atomic Fluorescence spectrometers as detectors was developed to analyze mercury, arsenic, and barium from herbarium mount paper originating from the herbarium collection of the National Museum of Wales. The variables influencing extraction were optimized by a multivariate approach. The optimal conditions were found to be 1% HNO3 extractant solution used at a flow rate of 1 mL min?1. The duty cycle and amplitude of the ultrasonic probe was found to be 50% in both cases with an ultrasound power of 400 W. The optimal distance between the probe and the top face of the extraction chamber was found to be 0 cm. Under these conditions the time required for complete extraction of the three analytes was 25 min. Cold vapor and hydride generation coupled to atomic fluorescence spectrometry was utilized to determine mercury and arsenic, respectively. The chemical and instrumental conditions were optimized to provide detection limits of 0.01 ng g?1 and 1.25 ng g?1 for mercury and arsenic, respectively. Barium was determined by graphite-furnace atomic absorption spectrometry, with a detection limit of 25 ng g?1. By using 0.5 g of sample, the concentrations of the target analytes varied for the different types of paper and ranged between 0.4–2.55 µg g?1 for Ba, 0.035–10.47 µg g?1 for As, and 0.0046–2.37 µg g?1 for Hg.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号