首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 734 毫秒
1.
A method was developed for the extraction of seven N-nitrosamine compounds from water by solid-phase microextraction (SPME). The method developed requires a total analysis time of only 1.25 h for both extraction and detection (versus 3-20 h for other isolation techniques). Three gas chromatography (GC) detection systems were tested with the SPME method, nitrogen chemiluminesence detection (NCD), nitrogen-phosphorus detection (NPD) and chemical ionization mass spectrometry (CI-MS), with method detection limits (MDLs) found in the ng/L range. This method was used to analyze wastewater samples and showed excellent selectivity of extraction. The detection limits of this method for N-nitrosodimethylamine (NDMA) range from 30 to 890 ng/L as a function of detector type. The excellent selectivity of SPME in addition to the fast analysis time would make this method ideal for general surveys, wastewater analysis and laboratory studies (e.g. degradation kinetics or formation potential).  相似文献   

2.
A new calibration method for high-performance liquid chromatography was validated. The method was called single-injection calibration approach (SICA) because it allowed to obtain a complete calibration curve by means of a single injection of a standard solution containing several non-volatile and semi-volatile organic compounds at different concentration levels. The compounds studied included carboxylic acids, polyalcohols, carbohydrates and water-soluble vitamins. This method allowed a 1-7-fold reduction in the analysis time with regard to conventional calibration methods. The method was applied to three different chromatographic detection methods: refractive index (RI) detection, diode array detection (DAD) and inductively coupled plasma atomic emission detection (ICP-AED). Good linearity was achieved (r(2)>0.999) for the three detection methods but signal correction was required for RI detection and DAD. This fact demonstrated that ICP-AES was the most universal because the signal obtained for non-volatile and semi-volatile organic compounds was not a function of the chemical nature of the compound and only depended on the mass content of carbon. The method was validated by analyzing a reference non-fat milk powder sample as well as several real food samples (three fruit juices, four wines, three candies and a multivitamin complex).  相似文献   

3.
A study was conducted to compare the current conventional method and the impedance method for rapid detection of total counts of bacteria and fungi in bottled purified water. The results indicated that the corresponding detection rate for the 2 methods was 94.5 and 90.4%, respectively. The detection time was shortened from 48 h (bacteria) and 5 days (fungi) to 14.5 and 44 h, respectively. Moreover, for more serious contamination, less time was needed. The impedance method predicted a positive sample within 11.3 h (bacteria) and 27.1 h (fungi). Therefore, the impedance method was found to be a rapid, accurate method.  相似文献   

4.
基于智能手机定量测定蛋白质的方法研究   总被引:1,自引:0,他引:1  
利用智能手机完成了蛋白质浓度的检测,确定了用于图像比色的参数,方法适用于有颜色反应的分析物浓度检测。利用该法检测的相关系数大于0. 99,检出限为0. 21 g/L。考察了不同品牌手机的检测效果,结果表明,检测效果与手机硬件的配置无明显关联。考察了该方法的重复性,对单个样本检测时,3种质量浓度样本的相对标准偏差(RSD)分别为2. 0%、4. 6%、11. 9%;对4个样本进行同时检测,RSD分别为2. 2%、3. 8%、3. 5%、11. 5%。考察了亮度、色温、拍摄距离的影响,结果显示,亮度与色温对检测结果无影响,而拍摄距离有影响。手机APP与分光光度计对样本检测结果的相关系数(r2)为0. 969。该方法准确、重复性高、便携、操作方便,可实现多种分析物实时现场的快速检测。  相似文献   

5.
A simple and rapid detection method of oligosaccharides using high-performance liquid chromatography with a charged aerosol detection (HPLC-CAD) was studied. The direct detection of a sialylglycopeptide (SGP) derived from egg yolk was accomplished by HPLC-CAD using an amido-silica column, and its limit of detection was 0.40 pmol [signal-to-noise ratio (S/N) = 3]. The sensitivity of this method was lower than that of the fluorescence detection; however, the method showed approximately 5 times higher sensitivity than that using the conventional UV absorbance detection. Furthermore, this method was used for the analysis of the acid hydrolysis products of SGP. Monosialo- and asialo-oligosaccharides as well as free sialic acid were detected without using fluorescent derivatization. These results indicate that the present method is a new tool for the analysis of oligosaccharides.  相似文献   

6.
A polymerase chain reaction and capillary gel electrophoresis (PCR-CGE) method with ultraviolet (UV) or laser induced fluorescence detection (LIF) was established for the detection of chicken or turkey in heat-treated pork meat mixtures. Mitochondrial DNA samples extracted from heat treated meat were amplified with their corresponding specific primers yielding PCR products between 200 and 300 bp. LIF detection was superior than UV detection in terms of precision and sensitivity for the study of DNA fragments. The CGE-LIF method was highly reproducible and accurate for determining DNA fragment size. The PCR-CGE-LIF was sensitive since a significant fluorescent signal was obtained at the minimum admixture level employed of 1% in meat mixtures. Thus, the PCR-CGE-LIF method established was useful for the detection of chicken or turkey in heat treated meat mixtures and may prove to be useful for the detection of poultry meat in pork processed products.  相似文献   

7.
Celery was found to provoke human allergenic response in some countries. Labeling of celery ingredients was required by the European Union, and the threshold set at 10 mg/kg (0.001%). In our study, a celery mannitol transporter (Mat3) gene-based detection method was established by means of SYBR Green real-time PCR technique. No cross-reactivity was found between celery and the other food materials. Absolute detection limit (LODa), relative detection limit (LODr), and practical detection limit (LODp) of the method were determined through experiments on pure celery DNA, DNA mix, and spiked food samples. The method was able to detect 0.001% raw food sample and 0.01% heated food sample. The utility of the method was confirmed by the investigation of 13 commercial foods.  相似文献   

8.
A biocompatible in-tube solid-phase microextraction (SPME) device was used for the direct and on-line extraction of camptothecin and 10-hydroxycamptothecin in human plasma. Biocompatibility was achieved through the use of a poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column for extraction. Coupled to high performance liquid chromatography (HPLC) with UV detection, this on-line in-tube SPME method was successfully applied to the simultaneous determination of camptothecin and 10-hydroxycamptothecin in human plasma. The calculated detection limits for camptothecin and 10-hydroxycamptothecin were found to be 2.62 and 1.79 ng/mL, respectively. The method was linear over the range of 10–1000 ng/mL. Excellent method reproducibility was achieved, yielding RSDs of 2.49 and 1.59%, respectively. The detection limit (S/N=3) of camptothecin was found to reach 0.1 ng/mL using fluorescence detection. The proposed method was shown to cope robustly with the extraction and analysis of camptothecin and 10-hydroxycamptothecin in plasma samples.  相似文献   

9.
以紫脲酸铵(Murexide,MU)为还原剂及保护剂,采用水热合成法,合成了紫脲酸铵保护的荧光金纳米簇(MU-Au NCs),合成方法简单、快速.基于精胺对MU-Au NCs的荧光猝灭现象,建立了快速、超灵敏检测精胺的"Turn off"型荧光分析方法,在优化的条件下,本方法检测精胺的线性范围为0.003~300 μmol/L,检测限为1 nmol/L(S/N=3).本方法为构建精胺生物传感器及实际样品检测提供了理论基础和参考.  相似文献   

10.
制备了一种具有过氧化物酶活性的类普鲁士蓝/氧化石墨烯复合纳米材料(CoFe(Ⅲ)PBA/GO)。将具有过氧化物酶活性的CoFe(Ⅲ)PBA/GO和化学发光法相结合,构建了一种用于检测H2O2和抗坏血酸(AA)的化学发光分析法。CoFe(Ⅲ)PBA/GO催化H2O2产生的O2·-,·OH,1O2自由基氧化Luminol会产生很强的化学发光信号,通过检测化学发光强度可以实现对H2O2的检测。该方法检测H2O2的线性范围为0~0.8μmol/L,检测限为11 nmol/L。利用AA作为活性氧消除剂可以抑制化学发光反应的特点,实现了AA的检测。该方法测定AA的线性范围为0.02~0.8μmol/L,检测限为20 nmol/L。方法已应用于H2O2消毒水中H2O2和维生素C片中抗坏血酸的检测。  相似文献   

11.
CE methods have been developed for the determination of taurine in pharmaceutical formulation (microemulsion) and in biological media such as sweat. The CE system with end-column pulsed amperometric detection has been found to be an interesting method in comparison with UV and fluorescence detection for its simplicity and rapidity. A gold-disk electrode of 100 mm diameter was used as the working electrode. The effects of a field decoupler at the end of the capillary, separation voltage, injection and pressure times were investigated. A detection limit of 4 x 10(-5) mol/L was reached using integrated pulsed amperometric detection, a method successfully applied to taurine analysis of the biological samples such as sweat. For taurine analysis of oil-in-water microemulsion, fluorescence detector was the favored method, the detection limit of which was 4 x 10(-11) mol/L.  相似文献   

12.
Fuh MR  Hsieh CJ  Tai YL 《Talanta》1999,49(5):158-1075
This paper describes a newly developed high performance liquid chromatography/electrospray/mass spectrometry (HPLC/ES/MS) method for the determination of flunarizine (FZ) in artificial cerebrospinal fluid. The optimization for the detection of FZ in biological fluid by LC/ES/MS was investigated. The effects of solvent composition, the addition of modifier and flow rate on the detection of FZ by ES/MS were examined. The detection limit of this method (0.8 nM) proved to be much better than previously reported methods. Satisfactory accuracy (98.2–106.0%) of this newly developed method was obtained. The application of this method was demonstrated by analyzing FZ in rat microdialysis samples.  相似文献   

13.
A selective and sensitive electrospray ionization (ESI) mass spectrometry based method for detection of brassinosteroids (BS) in plant samples was developed. The limit of detection (LOD) was dramatically reduced over existing analytical methods using a microbore (1.00 mm) C18 column and chemical derivatization of free BS to dansyl-3-aminophenylboronates. The LOD in the selected-ion monitoring (SIM) mode for derivatized BS was 125 attomole (signal-to-noise ratio 3). The practical utility of the method is documented in Arabidopsis thaliana plant transformation of castasterone to brassinolide using a deuterium-labeled precursor. The method could be very useful for the detection of native BS in plant tissue and biosynthetic studies.  相似文献   

14.
A multiplex polymerase chain reaction (PCR) detection method for the simultaneous detection of animal-derived components from deer, cow, sheep, pig and horse in edible meat was established, and a multiplex PCR detection kit for the rapid detection of animal-derived components was developed. According to the mitochondrial cytochrome b (Cyt b) gene of bovine species, sheep species, pig species and horse species and the mitochondrial cytochrome c oxidase subunit I (COX 1) gene of sika deer and red deer as the target gene sequences of primers, the specific primers of five different species were designed, the PCR system was optimized, and the multiplex PCR identification method of five animal-derived components was established. The minimum detection amount was determined by sensitivity test. The results showed that five meat specific amplification bands could be found at the same time in the same reaction system, including 173 bp fragment for venison, 148 bp for beef, 261 bp for pork, 100 bp for mutton and 424 bp for horse, indicating that the method is specific and stable. The minimum detection limit by this method was 1 ng/μL, showing a high sensitivity. According to the different sites in different areas of animal mitochondrial genes, a multiplex PCR detection method was established and a detection kit was developed, and the rapid, sensitive, stable and high-throughput detection of five animal-derived components and adulterated animal components in edible meat can be realized by using the kit.  相似文献   

15.
孔昊  张强  张薇  刘伟文  曹成喜  樊柳荫 《色谱》2020,38(2):177-182
该文建立了一种可视化的、基于氧化还原反应界面移动距离定量检测辣根过氧化物酶(HRP)的方法。比较了隐色结晶紫显色体系和3,3',5,5'-四甲基联苯胺显色体系对HRP的显色效率,并构建了基于3,3',5,5'-四甲基联苯胺显色体系的氧化还原反应电泳滴定模型。同时,文中还设计了适用于该模型的小型化、便携式滴定检测芯片,并对滴定通道凝胶中组分进行了优化。结果表明,界面移动距离与HRP浓度存在对数线性关系,检测灵敏度可达0.002 mg/L,且可在10 min内完成HRP的裸眼检测。该方法不需要配备信号读取装置,用户只需要读取有色界面移动的距离即可实现对待测物的可视化定量检测,对于即时检测具有潜在的应用价值。  相似文献   

16.
The separation of fatty acids derivatised with Nile Blue (NB) by CE with detection using a red light-emitting diode (LED) was examined. NB was selected as the derivatisation agent due to its high molar absorption coefficient of 76,000 M(-1) cm(-1) at 633 nm, making it well suited for sensitive absorbance detection using a red 635 nm LED. NB-labelled fatty acids were separated by both MEKC using SDS micelles, i-PrOH and n-BuOH and by NACE in a number of solvents including MeOH, EtOH and ACN. The sensitivity of NACE was superior to MEKC, with detection limits of 5x10(-7)-7x10(-7) M obtained for each acid, approximately 20 times lower than the MEKC method. The NACE detection limits are approximately 100 times lower than previous reports on the separation of fatty acids by CE using indirect absorbance detection, ten times lower than using indirect fluorescence detection and are inferior only to those obtained using precapillary derivatisation and direct fluorescence detection. The efficiency of the NACE method was also superior to MEKC and allowed the separation of unsaturated fatty acids to be examined, although it was not possible to baseline-resolve linoleic (C18:2) and linolenic (C18:3) acids in a reasonable time. The method was used to analyse the fatty acid profile of two edible oils, namely sunflower and sesame oils, after alkali hydrolysis, where it was possible to identify both the saturated and unsaturated fatty acids in each sample.  相似文献   

17.
A relatively simple and cost-effective method utilizing HPLC with UV detection was developed to detect and quantify hydrazine in sludge samples. The method was developed primarily for sludge samples, but it can also be applicable to soil and other environmental samples. The hydrazines in the matrices were derivatized to hydrazones with benzaldehyde. The hydrazones were separated using HPLC with an RP C-18 column in an isocratic mode with methanol-water (95:5 v/v) and detected with UV detection at 313 nm. The detection limit (25 microL injection) for the method is 0.02 microg/mL of hydrazine.  相似文献   

18.
A simple, rapid continuous-flow solid-phase extraction method with gas chromatographic detection for the determination of organophosphorus pesticides is proposed. The continuous system consists of an adsorbent column where pesticides are preconcentrated and subsequently eluted with ethyl acetate. Various sorbent materials were assayed of which RP-C18 was found to provide the best results, with a sorption efficiency close to 100%. A comparative study of the determination of pesticides in aqueous samples was conducted using gas chromatography with nitrogen-phosphorus (NPD) and flame ionization (FID) detection. The detection limits of the method for 10 ml of sample were between 50-130 ng/l and 4.5-1 1.7 microg/l with NPD and FID detection, respectively. The method was used to determine organophosphorus pesticides in river, pond, well and tap waters, all with good precision (2.9-4.3%) and recoveries ranging from 93.8 to 104.5%.  相似文献   

19.
A novel method for the determination of vitamin B12 by high-performance liquid chromatography with fluorescence detection is reported. The method was simple and highly sensitive with good precision. Vitamin B12 was analyzed by HPLC on a muBondapak C18 column (300x3.9 mm, 10 microm) with methanol-water (30:70) as mobile phase and fluorescence detection at 305 nm (with excitation at 275 nm). The calibration graph was linear from 1.000 to 100.0 ng ml(-1) for vitamin B12 with a correlation coefficient of 0.998 (n=6). The detection limit was 0.1 ng ml(-1). The method was successfully applied to the determination of vitamin B12 in vitamin B12 tablets, multivitamin tablets and fermentation medium. The recovery was from 94 to 102% and the relative standard deviation was in the range of 1.8 to 4.1%.  相似文献   

20.
Hexavalent chromium detection in the presence of a high load of colourants without any false positive and in-procedure oxidation of Cr(III) is an important area of study. Colourants are a class of interfering substances in many spectroscopic analyses and chromatographic separations and detection. A purification method using an on-line dialysis technique for ion chromatography (IC) has been developed to remove water-soluble anionic dyes and particulate colourants and other substances to facilitate Cr(VI) quantification and the method is discussed. The dialysis was optimized with Cr(VI) standard solutions for quantification. The efficacy of the procedure for the removal of anionic dyes and detection of Cr(VI) was checked with a Cr(VI) spiked synthetic preparation containing a water-soluble dye and trivalent chromium. Soluble Cr(VI) extracted with organic dyes from environmental samples was analyzed. The method has a detection limit of 5 microg/l, recovery rate of 100% and analysis time less than 20 min.  相似文献   