首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ao X  Stenken JA 《The Analyst》2003,128(9):1143-1149
Microdialysis relative recovery (RR) enhancement using different water-soluble, epichlorohydrin-based cyclodextrin polymers (CD-EPS) was studied in vitro for different analytes, amitryptiline, carbamazepine, hydroquinone, ibuprofen, and 4-nitrophenol. When compared to the native CDs (alpha, beta, and gamma) on a per mole basis, the CD-EPS enhanced microdialysis RR was either statistically greater or the same. beta-CD-EPS was more highly retained than native beta-CD by a 20 000 Da molecular weight cutoff (MWCO) polycarbonate membrane, but showed no statistical difference for loss across a 100 000 Da MWCO polyethersulfone membrane (PES). When the same weight percent of beta-CD or beta-CD-EPS was included in the microdialysis perfusion fluid, the beta-CD-EPS produced a higher microdialysis RR than native beta-CD for all analytes across the PES membrane. However, enhancements for the PC membrane were statistically insignificant when beta-CD and beta-CD-EPS were compared on a per mole basis. These results suggest that CD-EPS may be used as effective enhancement agents during microdialysis sampling and for some membranes provide the additional advantage of being retained more than native CDs.  相似文献   

2.
Cyclodextrin-modified electrokinetic chromatography (CD-EKC) was investigated for the separation of 12 monomethylbenz[a]anthracene (MBA) isomers. Combined use of a polymeric surfactant, poly(sodium 10-undecenyl sulfate) (poly-SUS), with various types of neutral cyclodextrins (CDs) [beta-CD, gamma-CD, dimethyl-beta-CD (DM-beta-CD), trimethyl-beta-CD (TM-beta-CD) and hydroxypropyl-beta-CD (HP-beta-CD)] were successful in CD-EKC separation of the MBA isomers. Baseline resolution of 10 of the 12 isomers, except for 9-MBA and 2-MBA, was achieved with gamma-CD at pH 9.75. The beta-CD, gamma-CD, and beta-CD derivatives (DM-beta-CD, TM-beta-CD, HP-beta-CD) were found to have different resolution and selectivity. Additionally, the tR/t0 values of isomers were found to be dependent on the type and concentration of the CD additives. In general, tR/t0 values of MBA isomers decrease with an increase in the concentration of beta-CD derivatives, whereas the reversed was true when the concentrations of native beta-CD and gamma-CD were varied. The combination of 5 mM gamma-CD, 0.5% (w/v) poly-SUS, 35% (v/v) acetonitrile at a pH of 9.75 provided the best selectivity and resolution of the MBA isomers with a separation time of 110 min. However, the use of 30 mM DM-beta-CD under similar EKC conditions resulted in much faster separation (ca. 16 min) of 10 MBA isomers.  相似文献   

3.
Cyclodextrins (CDs) are widely used in the pharmaceutical industry for their capability of improving bioavailability, solubility, or stability of drugs via the formation of soluble inclusion complexes. CDs have also been widely used in various chemical analysis methods. In this work, liquid chromatography/electrospray mass spectrometry (LC/ESI-MS) analysis for four different drugs (imipramine, desipramine, propranolol, and naproxen) that form inclusion complexes with CDs was performed in the presence and absence of beta-CD. These drugs are subject to nonspecific adsorption when brought into contact with plastics, such as HPLC tubing, sample collection and preparation apparatus, etc. Inclusion of the CD in the samples reduces this nonspecific adsorption due to competitive complex formation between the CD and the analyte. ESI-MS ion intensities increased when beta-CD was included in the sample with concentrations up to 1% (w:v), with a diverter valve installed post LC column. The degree of increased ion signal correlated with the beta-cyclodextrin:analyte binding constant. beta-CD appeared to elute within the void volume time and was observed in a full spectrum scan among the different analyte samples with up to 0.01% beta-CD injected directly to the LC/MS system with the diverter valve switched inline with the mass spectrometer. The use of the diverter valve allowed for direct injection of samples containing up to 1% beta-CD to the LC/MS without any deterioration of analyte ion signal.  相似文献   

4.
郭娜  高新星  徐国防  郭兴杰 《色谱》2008,26(2):259-261
采用C18固定相,以羟丙基-β-环糊精为手性流动相添加剂,建立了奥昔布宁对映体的高效液相色谱拆分方法。考察了手性添加剂、有机极性调节剂、缓冲盐的种类和浓度以及流动相的pH值和流速及柱温等因素对对映体分离的影响。在最佳分离条件下,奥昔布宁对映体的分离度为1.54,检测限为1.0 ng。该方法简便,重复性好,比手性固定相法更加经济。  相似文献   

5.
A new method for the CE separation of nine tricyclic antidepressants (TCAs), viz. amitriptyline, clomipramine, desipramine, doxepin, fluphenazine, imipramine, nortriptyline, promazine, and thioridazine, is described. The capillary was statically coated with a layer of poly(N,N-dimethylacrylamide) (PDMA) to suppress the EOF, and beta-CD was used as an additive in the BGE solution. The optimal resolution of nine TCAs was obtained by using a 1% v/v PDMA-coated capillary and a BGE solution of 50 mM sodium phosphate buffer (pH 3.0) containing 0.5 mM beta-CD. Efficiencies were typically >10(5 )plates/m. Complete separation of nine TCAs could be achieved in about 28 min; the two diastereomers of doxepin and the two enantiomers of thioridazine could also be separated. The RSD values of migration time and peak area of the TCAs were in the ranges 0.5-0.8 and 3.3-4.9% (n = 10), respectively. In combination with a suitable sample clean-up technique, such as hollow fiber-based liquid phase microextraction (HF-LPME), the polymer-coated capillary can be employed for the CE-UV analysis of TCAs in human plasma.  相似文献   

6.
 采用 5种环糊精衍生物对碱性药物硫喷妥钠、盐酸氟桂利嗪、山梗菜碱进行了毛细管区带电泳的手性拆分。结果表明 ,采用含 2 % (质量分数 ,其余相同 )聚合 β 环糊精 (P β CD)或 0 5%羧甲基聚合 β 环糊精 (CM P β CD) 30mmol/L的Tris H3PO4缓冲液可使这 3种药物达到基线分离 ;使用CM P β CD时 ,分离度高达 4~35。  相似文献   

7.
A strategy to enhance the microdialysis relative recovery for sampling of Cu and Ni ions is presented. Enhanced recovery was achieved by incorporating humic acid, a binding agent, in the microdialysis perfusion liquid during sampling from a Cu and Ni standard solution mixture. All microdialysis sampling experiments were carried out at room temperature under quiescent conditions using a concentric type of microdialysis probe with an adjustable effective dialysis length. For all metal determinations electrothermal atomic absorption spectrometry was employed. Metal recoveries were shown to be dependent on the membrane molecular weight cut-off, perfusion rate, sample solution pH, perfusion liquid composition as well as perfusion liquid pH. Complete recoveries (100%) of Cu and Ni were obtained by microdialysis sampling using a 10 kDa molecular weight cut-off polysulfone membrane at a flow-rate of 2 μl/min employing a 0.05% (w/v) optimal composition of humic acid incorporated in the perfusion liquid. The optimal sampling pH of humic acid was determined to be 6 where most oxygen containing functional groups are dissociated and available for metal binding. These data have important ramifications for sampling and determination of metal ions in small sample solutions (∼10 ml) at very low concentrations in the ppb range.  相似文献   

8.
The interaction of rutin and venoruton (troxerutin), with alpha-, beta- and gamma-cyclodextrin (CD), hydroxypropyl-beta-cyclodextrin (HP-beta-CD) and methyl-beta-cyclodextrin (M-beta-CD) was investigated by reversed-phase thin layer chromatography on polyamide plates. A mobile phase consisted of NH(4)OH; NH(4)Cl buffer solution containing various CD concentrations (pH = 9.7, 20 degrees C) was used as mobile phase. The equilibrium constants (K(f)) and the retention factor (R(f)) were determined and used to study the inclusion process. The in fluence of CDs on the solubility of rutin and venoruton was characterized by R(M) values and the increasing hydrophilicity of drugs. The results show that the inclusion capacity of cyclodextrins follows the order HP-beta-CD > M-beta-CD > beta-CD > gamma-CD, and rutin is more easily included by the studied cyclodextrins than venoruton. In addition, the thermodynamic parameters (Delta H, Delta S) for the formation of complexes were obtained from the van't Hoff equation, displaying the enthalpy-entropy compensation effect.  相似文献   

9.
The interaction between doxepin, a member of the tricyclic antidepressant (TCA) class of drugs, with beta-cyclodextrin (beta-CD) was investigated using NMR. Several TCAs have been reported to form a complex with beta-CD having 1:1 stoichiometry. Previous results from UV-visible spectroscopy, fluorescence measurements, and molecular modeling indicated that for imipramine, desipramine, and amitriptyline, the TCA aliphatic tail is included in the cyclodextrin cavity with apparently no interaction of the tricyclic ring. An alternative view of the doxepin-beta-CD complex is presented in this work using analysis of complexation-induced chemical shifts (CICSs), the method of continuous variation (Job's analysis), and analysis of ROESY spectra. The Job's plot derived from the NMR spectral data confirms that the complex formed has 1:1 stoichiometry. The largest changes in the CICS data were observed for the aromatic protons of one of the doxepin rings, with much smaller chemical shift changes observed for the protons of the other aromatic ring and the doxepin tail. Perhaps the most significant evidence for inclusion of the doxepin tricyclic ring is the strong ROESY cross peaks between the doxepin aromatic resonances and the protons located inside the beta-CD cavity. Changes in the doxepin (1)H NMR spectrum and the behavior of ROESY exchange cross peaks suggest that inclusion complex formation decreases the rate of internal motions of doxepin.  相似文献   

10.
Abstract

A reversed phase HPLC procedure is described for measuring the plasma concentration of four commonly used tricyclic anti-depressants (TCA): amitriptyline, desipramine, imipramine and nortriptyline in the range of 25 to 800ng per ml. The procedure involves rapid extraction, and HPLC analysis using a μBondapak C-18 column at 50°C, and a 254nm detector. Coefficients of variation are less than 5% for within run, and 7% for day-to-day experiments. Detection limits are: desipramine -0.5ng, nortriptyline or imipramine -0.6ng, and amitriptyline -0.7ng. Propoxyphene interferes with amitriptyline while chlorpromazine interferes with clomipramine. The procedure is easily adapted for clinical drug monitoring of TCA.  相似文献   

11.
Ao X  Stenken JA 《The Analyst》2006,131(1):62-67
The temporal response to concentration changes external to a microdialysis probe containing trapping agents in the perfusion fluid was studied. Native beta-cyclodextrin and a water-soluble beta-cyclodextrin polymer were used as trapping agents in the microdialysis perfusion fluid to study the temporal concentration response to carbamazepine, a hydrophobic analyte. The temporal response of microdialysis probes containing antibody-immobilized microspheres against five different cytokines (tumor necrosis factor-alpha (TNF-alpha), interferon-gamma (IFN-gamma), interleukin-2 (IL-2), IL-4, and IL-5) to concentration changes outside of the probe was also determined. In both cases, no delayed temporal response of enhanced microdialysis was observed for either carbamazepine or the cytokines as compared to standard microdialysis sampling procedures.  相似文献   

12.
Lin CE  Liao WS  Cheng HT  Kuo CM  Liu YC 《Electrophoresis》2005,26(20):3869-3877
In this study, enantioseparations of five phenothiazines, including promethazine, ethopropazine, trimeprazine, methotrimeprazine, and thioridazine, in CD-modified CZE using dual CD systems consisting of randomly sulfate-substituted CD (MI-S-beta-CD) and a neutral CD as chiral selectors in a citrate buffer (100 mM) at pH 3.0 were investigated. The results indicate that MI-S-beta-CD is an excellent chiral selector for enantioseparation of ethopropazine. The enantiomers of promethazine can also be baseline-resolved with MI-S-beta-CD at concentrations in the range of 0.5-1.0% w/v. On the other hand, thioridazine and trimeprazine interact strongly with neutral CDs. As a result, the enantioselectivity of these two phenothiazines is remarkably and synergistically enhanced with increasing the concentration of neutral CDs in the presence of MI-S-beta-CD and simultaneous enantioseparations of these phenothiazines, except for methotrimeprazine, could favorably be achieved with the use of dual CD systems. Moreover, by varying the concentration of beta-CD or gamma-CD at a fixed concentration of MI-S-beta-CD (0.75% w/v) reversal of the enantiomer migration order of promethazine occurred. This may be attributable to the opposite effects of charged and neutral CDs on the mobility of the enantiomers of promethazine.  相似文献   

13.
Solid-phase microextraction (SPME)-liquid chromatography (LC) is used to analyze tricyclic antidepressant drugs desipramine, imipramine, nortriptyline, amitriptyline, and clomipramine (internal standard) in plasma samples. Extraction conditions are optimized using a 2(3) factorial design plus a central point to evaluate the influence of the time, temperature, and matrix pH. A Polydimethylsiloxane-divinylbenzene (60-mum film thickness) fiber is selected after the assessment of different types of coating. The chromatographic separation is realized using a C(18) column (150 x 4.6 mm, 5-microm particles), ammonium acetate buffer (0.05 mol/L, pH 5.50)-acetonitrile (55:45 v/v) with 0.1% of triethylamine as mobile phase and UV-vis detection at 214 nm. Among the factorial design conditions evaluated, the best results are obtained at a pH 11.0, temperature of 30 degrees C, and extraction time of 45 min. The proposed method, using a lab-made SPME-LC interface, allowed the determination of tricyclic antidepressants in in plasma at therapeutic concentration levels.  相似文献   

14.
A simple, rapid and sensitive hollow-fiber with drop-to-drop solvent microextraction (HF-DDSME) combined with gas chromatography?Cmass spectrometry (GC?CMS) has been successfully developed for extraction and determination of antidepressants drugs (AD) in blood sample. The parameters that affect the separation and preconcentration of AD from sample solution were investigated. Calibration curve obtained for three AD were in the range of 100?C1,000; 150?C1,200; and 80?C1,200 ng mL?1 for amitriptyline, imipramine, and promethazine, respectively, with correlation coefficient (R 2 ) between 0.990 and 0.997. The limit of detection (LOD) obtained for amitriptyline, imipramine and promethazine was 25, 30 and 18 ng mL?1, respectively. The developed method has been successfully applied for the determination of AD concentration in blood sample, and the recoveries for the spiked samples were in the range of 92.3?C97.6%. The sample preparation procedure is very simple, effective and virtually solvent-free, and indicated to be a good alternative for the traditional liquid?Cliquid extraction. Finally, the proposed method was successfully applied for the determination of drug concentration of AD in human blood sample.  相似文献   

15.
In the present study, a supramolecular solvent was formed from reverse micelle aggregates of octanol. The proposed supramolecular solvent was used for rapid extraction of some antidepressants drugs including amitriptyline, imipramine, desipramine, maprotiline, sertraline, and doxepin from biological samples. Alkanol‐based supramolecular solvents have a unique array of physicochemical properties, making them a very attractive alternative to replace organic solvents in analytical extractions. The parameters affecting the extraction of target analytes (i.e., the volume of tetrahydrofuran and octanol as the major components comprising the supramolecular solvent, chain length of alkanols, sample solution pH, salt addition, and ultrasonic time) were investigated and optimized by factor by factor optimization method. Under the optimum conditions, preconcentration factors of 470, 490, 460, 385, 370, and 430 were obtained for amitriptyline, doxepin, imipramine, desipramine, maprotiline, and sertraline, respectively. The linear ranges and coefficients of determination (R2) were obtained in the range of 0.01–100 μg/L and 0.9974–0.9991, respectively. Also the limits of detection (S/N = 3) of 0.003–0.03 μg/L, and precisions (n = 5) of 4.9–8.9% were calculated. Finally, the method was successfully applied for the extraction of antidepressant drugs in biological samples, and relative recoveries in the range of 91–102% were obtained.  相似文献   

16.
A solid-phase extraction (SPE) method for sample clean-up followed by a reversed-phase high-performance liquid chromatography (HPLC) procedure for the assay of five antidepressant drugs (trazodone, doxepin, desipramine, maprotiline and imipramine) is reported. The drugs were recovered from plasma buffered at a suitable pH using C18 Bond-Elut cartridges and mixtures of methanol-aqueous buffer as washing and elution solvents. The recoveries of the drugs using other sorbent materials (C8, C2, cyclohexyl, cyanopropyl and phenyl Bond Elut and copolymer HLB waters cartridges) were also examined. The selectivity of SPE was examined by using spiked plasma samples and the CH cartridge gave rise to the cleanest extracts. Cyclohexyl cartridges were conditioned successively with 2 ml of methanol and 1 ml of acetic acid-sodium acetate buffer (0.1 M, pH 4.0). Plasma sample was buffered at pH 4.0 and then applied to the sorbent. The washing step was performed subsequently with 1.5 ml of acetate buffer (0.1 M, pH 4.0), 100 microl of acetonitrile and 1 ml of methanol-acetate buffer (30:70, v/v). Finally, the analytes were eluted with 0.5 ml of methanol-acetate buffer (70:30, v/v). The extract was evaporated to dryness, reconstituted in mobile phase, and chromatographed on a reversed-phase C18 column with ultraviolet detection at 215 nm. The recoveries of trazodone, doxepin, desipramine, maprotiline and imipramine from spiked plasma samples using the CH cartridge were 58 2, 84 3, 83 3, 83 3 and 82 2%, respectively. The within-day and between-day repeatabilities were lower than 6% and 9%, respectively. The linearity of calibrations for the five antidepressants was between 0.005 and 2 microg/ml. The limits of detection were 1 ng/ml for trazodone, doxepin and desipramine and 2 ng/ml for maprotiline and imipramine.  相似文献   

17.
Greenway GM  Dolman SJ 《The Analyst》1999,124(5):759-762
A novel method has been investigated for the selective and sensitive determination of a range of tricyclic antidepressants including amitriptyline, doxepin, nortriptyline, promazine, chlorpromazine, imipramine, clomipramine, desipramine, protriptyline and trimipramine using electrogenerated chemiluminescence (ECL). The ECL mechanism is based on the reaction between tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)3(2+)] and the tertiary amino groups on the antidepressants. After selecting the best operating parameters calibration curves were obtained over three orders of magnitude for amitriptyline, doxepin, nortriptyline, promazine and chlorpromazine. Linear calibrations were used to obtain limits of detection in the range 0.09-0.24 microgram ml-1 with relative standard deviations below 4% for five replicate samples. Rapid depression in the signal was observed with repeat analysis of imipramine, clomipramine, protriptyline, desipramine and trimipramine due to electrode fouling by the oxidation product of the reaction. Use of a lower concentration of the compound was found to alleviate the problem. Finally the concentration of doxepin was determined in a pharmaceutical preparation.  相似文献   

18.
Cyclodextrins and antibodies have been used as affinity agents to improve relative recovery during microdialysis sampling. Two neuropeptides, methionine-enkephalin (ME) and leucine-enkephalin (LE), were chosen to compare the use of cyclodextrins and antibodies as possible affinity agents for improving their relative recovery across polycarbonate and polyethersulfone membranes during in vitro sampling. Cyclodextrins (CD) including β-CD, 2-hydroxypropyl-β-cyclodextrin (2HPβ-CD), and γ-CD gave improvements of relative recovery for both peptides of less than 2-fold as compared to controls. Comparisons of relative recovery between tyrosine–glycine–glycine, tyrosine, and phenylalanine using different cyclodextrins in the perfusion fluid were also obtained. Inclusion of an antibody against met-enkephalin in the microdialysis perfusion fluid resulted in relative recovery increases of up to 2.5-fold. These results show that using antibodies as affinity agents during microdialysis sampling may be more effective agents to improve the relative recovery of these opioid neuropeptides.  相似文献   

19.
A novel methylcellulose-immobilized restricted access media column with strong cation-exchange groups on an internal surface (MC-SCX) was evaluated for the direct injection analysis of basic polar drugs in plasma by column-switching liquid chromatography/mass spectrometry (LC/MS). Analytical conditions, including an automated pretreatment step and MS detection, were optimized for a series of basic drugs (doxepin, desipramine, imipramine, nortriptyline, amitriptyline, clomipramine). On-line pretreatment with the MC-SCX column followed by fast gradient analysis using a C18 column resulted in a total analysis cycle time of 7 min for each spiked plasma sample. More than 150 plasma samples spiked with target compounds were measured without compromising MS detection (relative standard deviations less than 11% for all compounds, and regression coefficients greater than 0.99).  相似文献   

20.
Solid-phase microextraction coupled to liquid chromatography and mass spectrometry (SPME-LC-MS) was used to analyze tricyclic antidepressant drugs desipramine, imipramine, nortriptyline, amitriptyline, and clomipramine (internal standard) in plasma samples. SPME was performed by direct extraction on a PDMS/DVB (60 microm) coated fiber, employing a stirring rate of 1200 rpm for 30 min, pH 11.0, and temperature of 30 degrees C. Drug desorption was carried out by exposing the fiber to the liquid chromatography mobile phase for 20 min, using a labmade SPME-LC interface at 50 degrees C. The main variables experimentally influencing LC-MS response were evaluated and mathematically modeled. A rational optimization with fewer experiments was achieved using a factorial design approach. The constructed empirical models were adjusted with 96-98% of explained deviation allowing an adequate data set comprehension. The chromatographic separation was realized using an RP-18 column (150 mm x 2.1 mm, 5 microm particles) and ammonium acetate buffer (0.01 mol/l, pH 5.50) : acetonitrile (50 : 50 v/v) as mobile phase. Low detection levels were achieved with electrospray interface (0.1 ng/ml). The developed method showed specificity, linearity, precision, and limit of quantification adequate to assay tricyclic antidepressant drugs in plasma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号