首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and rapid method based on multi-throughput dynamic microwave-assisted extraction coupled online with salting-out-assisted liquid–liquid extraction was developed for the analysis of chlorpyrifos in soil. First, the chlorpyrifos was extracted with acetonitrile aqueous (50%, v/v) under the action of microwave energy. Then the obtained extract was separated clearly and easily into an acetonitrile phase and an aqueous phase with the assistance of ammonium acetate. The acetonitrile phase containing chlorpyrifos was concentrated and determined by liquid chromatography–tandem mass spectrometry. The effects of parameters on extraction efficiency including microwave power, extraction solvent, volumes and flow rate of extraction solvent, sample pH, types and amount of salt were studied and optimised. To eliminate the matrix effect, validation of the method was carried out using the matrix-based calibration curve. The limits of detection and quantification for chlorpyrifos were 0.17 and 0.5 ng g?1, respectively. The proposed method was applied to analyse chlorpyrifos in five soil samples and verified by the recovery test. The recoveries of chlorpyrifos at three spiked levels (5, 50, 200 ng g?1) were in the range of 90.0–100.5%, with relative standard deviations varying from 1.3% to 5.7%. Compared with the methods reported previously, the proposed method can simplify the operation procedure and reduce solvent consumption in sample pretreatment.  相似文献   

2.
Heterocyclic amines (HAs) were analysed in meat extract samples using a new method based on pressurised liquid extraction (PLE) and liquid chromatography-tandem mass spectrometry. This method combines the use of a pressurised fluid with a triple quadrupole MS/MS system, resulting in benefits from both systems: high extraction efficiency and sensitivity. The effects of solvent type and PLE operational parameters, such as temperature and extraction time, were studied to obtain maximum recovery of the analytes with minimum contamination. HA extraction was best achieved using dichloromethane/acetone (50/50, v/v) at 80 degrees C for 10 min. Recoveries ranged from 45% to 79% with good quality parameters: limit of detection values between 0.02 and 1 ng g(-1), linearity (r(2)>0.997), and run-to-run and day-to-day precisions with relative standard deviations lower than 13% achieved at both low (0.20 microg g(-1)) and medium (1.0 microg g(-1)) concentrations. This method reduces sample manipulation and total extraction time by nearly four-fold compared to conventional solid phase extraction. The optimised method was validated using laboratory reference material based on a meat extract, and was successfully applied to HA analysis in several cooked beef samples.  相似文献   

3.
A novel, simple and rapid method, termed dispersive liquid–liquid microextraction with solidification of floating organic drop coupled to high performance liquid chromatography, was developed for analysis of three phenolic oestrogens including diethylstilbestrol, dienestrol and hexestrol in human urine and water samples. The parameters of dispersive liquid–liquid microextraction with solidification of floating organic drop procedure including sample pH, type and volume of disperser solvent, and type and volume of extraction solvent were optimised. High performance liquid chromatography was applied for the phenolic oestrogens’ analysis. Under the optimum extraction and detection conditions, excellent analytical performances were attained. Good linear relationships (r ≥ 0.998) between peak area and concentration for diethylstilbestrol and dienestrol were optimised from 0.1 to 20 µg/mL, for hexestrol from 2 to 50 µg/mL. Method detection limits of 28.6–666.7 ng/mL were achieved. Satisfactory relative recoveries ranging from 72% to 122% were determined for urine, lake and tap water samples, with relative standard deviations (RSDs, n = 6) of 1.5–9.8%. The developed dispersive liquid–liquid microextraction with solidification of floating organic drop-high performance liquid chromatography method has a great potential in routine residual analysis of trace phenolic oestrogens in biological and water samples.  相似文献   

4.
A new method for the simultaneous determination of three fluoroquinolones (FQs) enrofloxacin (ENRO) ciprofloxacin (CIPRO) and sarafloxacin (SARA) in table eggs has been developed, applying pressurized liquid extraction (PLE) and liquid chromatography (LC) with fluorescence detection (LC-FLD). The influence of several extraction parameters (e.g. solvent mixture, temperature and extraction time) on FQs extraction efficiency and coextracted matrix interferents was evaluated using fortified control eggs and matrix matched standard curves. The results showed that FQs extraction efficiency depends mainly on solvent composition and the optimum extraction mixture was found to be phosphate 50mM, pH 3.0/acetonitrile (50:50, v/v). The optimized procedure employed 50% flush volume, 5min of static time and three extraction cycles at 70 degrees C and 1500psi. Method validation was performed according to the guidelines of the Directive 96/23/EC, using control egg samples, fortified with the target FQs in the range 50-1000ngg(-1) and applying the optimized extraction conditions on three different days, providing recoveries between 67-90% with RSDs lower than 11% in all cases. The decision limit (CCalpha) and detection capability (CCbeta) of the analytical method were found to be within the range 17-24ngg(-1) and 30-41ngg(-1), respectively. The method was successfully applied to the determination of ENRO and its metabolite CIPRO in incurred egg samples from ENRO-treated hens and LC-MS has been used and for confirmatory purposes.  相似文献   

5.
A liquid–liquid extraction method using diethyl ether as organic solvent was optimized simultaneously for five 1,4-dihydropyridines (amlodipine, nitrendipine, felodipine, lacidipine and lercanidipine) belonging to the group of calcium channel blockers. Some experimental tools such as a full factorial design, a central composite design and the Multisimplex program were used to optimise the concentration of NaOH, volume of organic solvent and shaking time as main factors that influence the liquid–liquid extraction procedure. Following the extraction, the quantitation of the 1,4-dihydropyridines concentrations were performed by high-performance liquid chromatography with diode-array detector. Therefore, the studied compounds were separated quantitatively on a Supelcosil ABZ+Plus, 25 cm × 4.6 mm i.d., 5 μm column which was set at 30 °C, using as mobile phase, a mixture of acetonitrile–water (70:30, v/v) containing 10 mM acetate buffer (pH 5) and setting the detector at a wavelength value of 360 nm. It was concluded that the main factors that influence in the extraction process were the volume of organic solvent and the shaking time. The Multisimplex program suggested as optimal conditions an average of 6 ml of organic solvent and 23 min of shaking time. For these values, the optimised liquid–liquid extraction method showed good values of recoveries (80% for amlodipine and higher than 90% for the rest of the compounds) and low values of R.S.D. (<10%) in the reproducibility of the extraction what makes it reliable for the quantification of all the studied compounds in human plasma.  相似文献   

6.
A molecularly imprinted polymer prepared using 1-allylpiperazine (1-ALPP) as the functional monomer, trimethyltrimethacrylate (TRIM) as the crosslinker and the zearalenone (ZON)-mimicking template cyclododecanyl-2,4-dihydroxybenzoate (CDHB) has been applied to the clean-up and preconcentration of this mycotoxin (zearalenone) and a related metabolite, alpha-zearalenol (alpha-ZOL), from cereal and swine feed sample extracts. The extraction of ZON and alpha-ZOL from the food samples was accomplished using pressurized liquid extraction (PLE) with MeOH/ACN (50:50, v/v) as the extraction solvent, at 50 degrees C and 1500 psi. The extracted samples were cleaned up and preconcentrated through the MIP cartridge and analyzed using HPLC with fluorescence detection (lambda (exc)=271/ lambda (em)=452 nm). The stationary phase was a polar endcapped C18 column, and ACN/MeOH/water 10/55/35 (v/v/v, 15 mM ammonium acetate) at a flow rate of 1.0 mL min(-1) was used as the mobile phase. The method was applied to the analysis of ZON and alpha-ZOL in wheat, corn, barley, rye, rice and swine feed samples fortified with 50, 100 and 400 ng g(-1) of both mycotoxins, and it gave recoveries of between 85 and 97% (RSD 2.1-6.7%, n=3) and 87-97% (RSD 2.3-5.6%, n=3) for alpha-ZOL and ZON, respectively. The method was validated using a corn reference material for ZON.  相似文献   

7.
A rapid, simple, and sensitive method was developed for lead preconcentration and separation in various real samples by dispersive liquid–liquid microextraction based on the freezing of floating organic drop. In this method, a suitable extraction solvent dissolved in a dispersive solvent was quickly syringed into the water sample so that the solution became turbid. Then, two phases were separated by centrifugation. The floating extractant droplet can be easily solidified on an ice bath and taken out of the water sample. Then, it can be liquefied instantly at room temperature, and analyte can be determined in it. In the creation of a hydrophobic complex with lead, 1-(2-pyridylazo)-2-naphthole (PAN) was used as the chelating agent. 1-Undecanol and acetone were used as extraction and disperser solvent. To achieve the highest recovery, some factors (type and volume of dispersive and extraction solvent, pH, PAN concentration, and salt concentration) were optimised. Under optimised conditions (pH = 9, 1.0 × 10–3 mol L?1 PAN, 15% w/v NaCl, 100 µL 1-undecanol, and 0.3 mL acetone), the lead calibration graph was linear from 1.5 to 80 μg L?1. The detection limit and preconcentration factor were 0.5 μg L?1 and 50, respectively. Lead was successfully determined in water and food (spinach, rice, potato, carrot, and black tea bag) samples by this method.  相似文献   

8.
A method termed dispersive liquid–liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detection (HPLC-VWD) was developed. DLLME-HPLC-VWD is a method for determination of bisphenol A (BPA) in water samples. In this microextraction method, several parameters such as extraction solvent volume, sample volume, disperser solvent, ionic strength, pH, and disperser volume were optimised with the aid of interactive orthogonal array and a mixed level experiment design. First, an orthogonal array design was used to screen the significant variables for the optimisation. Second, the significant factors were optimised by using a mixed level experiment. Under the optimised extraction conditions (extraction solvent: ionic liquid [C6MIM][PF6], 60 µL; dispersive solvent: methanol, 0.4 mL; and pH = 4.0), the performance of the established method was evaluated. The response linearity of the method was observed in a range of 0.002–1.0 mg L?1 (three orders of magnitude) with correlation coefficient (R 2) of 0.9999. The repeatability of this method was 4.2–5.3% for three different BPA levels and the enrichment factors were above 180. The extraction recovery was about 50% for the three different concentrations with 3.4–6.4% of RSD. Limit of detection of the method was 0.40 µg L?1 at a signal-to-noise ratio of 3. In addition, the relative recovery of sample of Songhua River, tap water and barrel-drain water at different spiked concentration levels was ranged 95.8–103.0%, 92.6–98.6% and 87.2–95.3%, respectively. Compared with other extraction technologies, there have been the following advantages of quick, easy operation, and time-saving for the present method.  相似文献   

9.
A new simple and rapid pretreatment method for simultaneous determination of 19 sulfonamides in pork samples was developed through combining the QuEChERS method with dispersive liquid–liquid microextraction followed by ultra‐high performance liquid chromatography with tandem mass spectrometry. The sample preparation involves extraction/partitioning with QuEChERS method followed by dispersive liquid–liquid microextraction using tetrachloroethane as extractive solvent and the acetonitrile extract as dispersive solvent that obtained by QuEChERS. The enriched tetrachloroethane organic phase by dispersive liquid–liquid microextraction was evaporated, reconstituted with 100 μL acetonitrile/water (1:9 v/v) and injected into an ultra‐high performance liquid chromatography with a mobile phase composed of acetonitrile and 0.1% v/v formic acid under gradient elution and separated using a BHE C18 column. Various parameters affecting the extraction efficiency were investigated. Matrix‐matched calibration curves were established. Good linear relationships were obtained for all analytes in a range of 2.0–100 μg/kg and the limits of detection were 0.04–0.49 μg/kg. Average recoveries at three spiking levels were in the range of 78.3–106.1% with relative standard deviations less than 12.7% (n = 6). The developed method was successfully applied to determine sulfonamide residues in pork samples.  相似文献   

10.
A selective extraction technique based on the combination of liquid membrane (microporous membrane liquid–liquid extraction) and molecularly imprinted polymers (MIP) was applied to triazines herbicides in food samples. Simazine, atrazine and propazine were extracted from aqueous food samples through the hydrophobic porous membrane that was impregnated with toluene, which also formed part of the acceptor phase. In the acceptor phase, the compounds were re-extracted onto MIP particles. The extraction technique was optimised for the amount of molecularly imprinted polymers particles in the organic acceptor phase, extraction time, and type of organic acceptor solvent and desorption solvent. An extraction time of 90 min and 50 mg of MIP were found to be optimum parameters. Toluene as the acceptor phase was found to give higher triazines binding onto MIP particles compared to hexane and combinations of diethyl ether and hexane. 90% methanol in water was found to be the best desorption solvent compared to acetonitrile, methanol and water. The selectivity of the technique was demonstrated by extracting spiked lettuce and apple extracts where clean chromatograms were obtained compared to liquid membrane extraction alone or to the microporous membrane liquid–liquid extraction – non-imprinted polymer combination. The MIP showed a certain degree of group specificity and the extraction efficiency in lettuce extract was 79% (0.72) for simazine, 98% (1.55) for atrazine and 86% (3.08) for propazine.  相似文献   

11.
Detailed below is a simple reversed-phase liquid chromatography (RP-LC) method for the simultaneous separation of up to 21 acidic, basic, and neutral pharmaceuticals using Merck Chromolith Performance RP-C18e monolithic columns with direct ultraviolet (UV) absorption detection. By simultaneously applying a solvent elution gradient program with a mobile phase flow gradient, both a decrease in the overall analysis time and a general increase in peak efficiencies were observed. Mobile phase pH and buffer concentration were optimised using the overall resolution product under applied gradient conditions. Under optimised conditions peak area reproducibility (n?=?6) ranged between 0.4 and 9.3%, determined at the method LOQ level. For real sample analysis pharmaceutical residues were extracted using an optimised solid phase extraction (SPE) procedure, utilising Strata-X extraction cartridges, which overall provided the highest relative recovery data in comparison with four other commercially available SPE sorbents (17 out of 20 residues investigated had recoveries over 70%). Complete method precision, including all sample pre-treatment and LC analysis for six spiked river water samples at the 1 and 2?µg?L?1 level was between 10 and 29%. Using 1?L volumes of 1?µg?L?1 spiked estuarine water samples, the majority of detection limits were found to be in the 10–50?ng?L?1 range.  相似文献   

12.
In the present study, an environment-friendly sample preparation method termed ionic liquid-based dispersive liquid–liquid microextraction combined with flame atomic absorption spectrometry has been developed for the determination of Pb(II) ion in water samples prior to flame atomic absorption spectrometry determination. In this method, ionic liquid was used as an extraction solvent instead of the organic solvent used in the conventional dispersive liquid–liquid microextraction (DLLME) assay, and there is no need for a chelating agent. Several variables that may affect extraction efficiencies, including pH, the volume of ionic liquid, the type and volume of disperser solvent, salt addition, and the time for centrifugation and extraction were studied and optimised. Under the optimised conditions, the calibration curve exhibited linearity over the range of 20.0–1000.0 μg L?1. The enrichment factor and the limit of detection based on 3Sb/m were 35.0 and 5.9 μg L?1, respectively. Seven replicate determination of a solution containing of 100.0 μg L?1 Pb(II) ions gave a relative standard deviation of ±2.1%. Finally, the feasibility of the proposed method for Pb(II) determination was assessed by the analysis of certi?ed reference material and various water samples and the satisfactory results were obtained.  相似文献   

13.
A novel water-compatible molecularly imprinted polymer (MIP), prepared with enrofloxacin (ENR) as the template, has been optimised for the selective extraction of fluoroquinolone antibiotics in aqueous media. The results of a morphological characterisation and selectivity tests of the polymer material for ENR and related derivatives are reported. High affinity for the piperazine-based fluoroquinolones marbofloxacin, ciprofloxacin, norfloxacin and ofloxacin was observed, whereas no retention was found for nonrelated antibiotics. Various parameters affecting the extraction efficiency of the polymer have been optimised to achieve selective extraction of the antibiotics from real samples and to reduce nonspecific interactions. These findings resulted in a MISPE/HPLC-FLD method allowing direct extraction of the analytes from aqueous samples with a selective wash using just 50% (v/v) organic solvent. The method showed excellent recoveries and precision when buffered urine samples fortified at five concentration levels (25–250 ng mL−1 each) of marbofloxacin, ciprofloxacin, norfloxacin, enrofloxacin and sarafloxacin were tested (53–88%, RSD 1–10%, n = 3). Moreover, the biological matrix of the aqueous samples did not influence the preconcentration efficiency of the fluoroquinolones on the MIP cartridges; no significant differences were observed between the recovery rates of the antibiotics in buffer and urine samples. The detection limits of the whole process range between 1.9 and 34 ng mL–1 when 5-mL urine samples are processed. The developed method has been successfully applied to preconcentration of norfloxacin in urine samples of a medicated patient, demonstrating the ability of the novel MIP for selective extraction of fluoroquinolones in urine samples.  相似文献   

14.
A method based on dispersive liquid–liquid microextraction coupled with GC/MS was developed for quantitative analysis of the major organic pollutants listed in the United States Environmental Protection Agency method 8270 and the 15 European‐priority polycyclic aromatic hydrocarbons in coking wastewater. The major parameters such as extraction solvent, dispersive solvent, solution pH, and extraction time were systematically optimized. The optimum extraction conditions were found to be: 15 μL mixture of 2:1 v/v carbon tetrachloride and chlorobenzene as the extraction solvent, 0.75 mL ACN as the dispersive solvent, solution pH of 8, and extraction time of 2 min. For the major pollutants listed in the United States Environmental Protection Agency 8270, the linear ranges were 0.1 to 100 mg/L, the enrichment factors ranged from 452 to 685, and the relative recoveries ranged from 67.5 to 103.5% with RSDs of 4.0–9.1% (n = 5) at the concentrations of 10 mg/L under the optimum extraction conditions. For the 15 polycyclic aromatic hydrocarbons, the linear ranges were 0.1 to 100 μg/L, the enrichment factors ranged from 645 to 723, and the relative recoveries ranged from 94.5 to 107.6% with RSDs of 4.6–9.0% (n = 5) at the concentrations of 10 μg/L. The usefulness of the developed method was demonstrated by applying it in the analysis of real‐world coking wastewater samples.  相似文献   

15.
A new sample treatment for liquid chromatographic analysis of ochratoxin A (OTA) in beer is proposed. Degassed beer is mixed with lead hydroxyacetate, which precipitates some bulk components but does not remove OTA. The precipitate is separated and the acidified liquid is extracted with chloroform. The solvent is evaporated and the residue is dissolved in mobile phase (acetonitrile-water, 40:60, v/v; acidified at pH 3.0 with phosphoric acid) and separated by liquid chromatography using fluorescence detection. The limit of detection was 0.005 ng/ml. The average recovery rate and the average RSD of recovery in the spiking level range 0.01-0.5 ng/ml were 95.5% and about 5%, respectively. The method is cheaper that other alternative ones using immunoaffinity columns or other solid-phase extraction cleanup:The separation was optimised with regard to composition and flow of the mobile phase and no interference from the matrix was found. The method was applied to 88 samples of beer (domestic and imported) marketed in Spain. OTA was detected in 82.9% of them. The range for positive samples was 0.007-0.204 ng of OTA/ml.  相似文献   

16.
A semi-automated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the determination of glimepiride in human plasma. The plasma samples were treated by liquid-liquid extraction (LLE) in 1.2 mL 96-well format micro-tubes. Glimepiride and the internal standard (IS) glibenclamide were extracted from human plasma by LLE, using a mixture of ethyl acetate/diethyl ether 50:50 (v/v) as the organic solvent. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated. The analyte and IS were dissolved in a small volume of a reconstitution solution, an aliquot of which was analyzed by reversed-phase LC/MS/MS with positive ion electrospray ionization, using multiple reaction monitoring. The method proved to be sensitive and specific for both drugs, and statistical evaluation revealed excellent linearity for the range of concentrations 2.0-500.0 ng/mL with very good accuracy and inter- and intra-day precisions. The proposed method enabled the rapid and reliable determination of glimepiride in pharmacokinetic or bioequivalence studies after per os administration of a 3 or 4 mg tablet of glimepiride.  相似文献   

17.
A simple and rapid HPLC method for determination of chlorogenic acid (5-O-caffeoylquinic acid) in mate tea extracts was developed and validated. The chromatography used isocratic elution with a mobile phase of aqueous 1.5% acetic acid-methanol (85:15, v/v). The flow rate was 0.8 mL/min and detection by UV at 325 nm. The method showed good selectivity, accuracy, repeatability and robustness, with detection limit of 0.26 mg/L and recovery of 97.76%. The developed method was applied for the determination of chlorogenic acid in mate tea extracts obtained by ethanol extraction and liquid carbon dioxide extraction with ethanol as co-solvent. Different ethanol concentrations were used (40, 50 and 60%, v/v) and liquid CO? extraction was performed at different pressures (50 and 100 bar) and constant temperature (27 ± 1 °C). Significant influence of extraction methods, conditions and solvent polarity on chlorogenic acid content, antioxidant activity and total phenolic and flavonoid content of mate tea extracts was established. The most efficient extraction solvent was liquid CO? with aqueous ethanol (40%) as co-solvent using an extraction pressure of 100 bar.  相似文献   

18.
This study investigated the feasibility of applying liquid-phase microextraction combined with gas chromatography-mass spectrometry (GC-MS) to determine polychlorinated biphenyls (PCBs) in blood plasma. An efficient and simple extraction technique has been developed for the enrichment of PCBs from human blood plasma samples using single-step liquid-phase microextraction (LPME) in conjunction with a hollow fibre membrane (HFM). An eight PCB congener mixture was spiked into 2.5 ml of blood plasma, and the solution was then adjusted to pH 10.5 with a salinity of 20% (w/v) prior to making the total volume to 5 ml with ultrapure water. The porous HFM, filled with 3 microl of organic solvent, was then immersed into the solution, which was continuously agitated at 700 rpm for 30 min. Extract (1 microl) containing the pre-concentrated analytes was then injected into a GC-MS without further pre-treatment. Using an optimised extraction procedure, a large enrichment factor of the analytes, i.e. up to 241-fold was achieved in 30 min. The procedure resulted in a relative standard deviation of < 11% (n = 6), and a linear calibration range from 2.5 to 150 microg/l (r > 0.999), and detection limits between 0.07 and 0.94 microg/l, respectively. To demonstrate the feasibility of the procedure, PCB concentrations were determined in actual blood samples collected from the local population in Singapore using the optimised LPME technique.  相似文献   

19.
The pressurized liquid extraction (PLE) followed by dispersive liquid–liquid micro‐extraction (DLLME) has been developed for extraction of volatile components in tobacco. 35 volatile components were detected by gas chromatography mass spectrometry (GC‐MS). Methanol–methyl tert‐butyl ether (MTBE) (8:2, v/v) was selected as PLE extraction solvent. The optimized DLLME procedure, 3 mL of pure water and 1.0 mL tobacco extract solution, 40 μL of chloroform as extraction solvent, 0.5 mL of acetonitrile as disperser solvent, was validated. Under the optimum conditions, the enrichment factors were in the range of 96‐159. The limits of detection were between 0.14 and 0.33 μg/kg. The repeatability of the proposed method, expressed as relative standard deviation, varied between 4.3 and 7.5% (n = 6). The recoveries of the analytes evaluated by fortification of tobacco samples were in the range of 84.7‐96.4%. Compared with the conventional sample preparation method for determination of volatile components in tobacco, the proposed method was quick and easy to operate, and had high‐enrichment factors and low consumption of organic solvent.  相似文献   

20.
A liquid chromatographic method with inductively coupled plasma mass spectrometry is proposed for the speciation of butyl- (monobutyltin, dibutyltin, tributyltin) and phenyl- (monophenyltin, diphenyltin, triphenyltin) tin compounds in sediments. After evaluation of different additives in the mobile phase, the use of 0.075% (w/v) of tropolone and 0.1% (v/v) of triethylamine in a mobile phase of methanol-acetic acid-water (72.5:6:21.5) allowed the best chromatographic separation of the six compounds. Pressurized liquid extraction (PLE) with a methanolic mixture of 0.5 M acetic acid and 0.2% (w/v) of tropolone was suitable for the quantitative extraction of butyl- and phenyltin compounds with recovery values ranging from 72 to 102%. This analytical approach was compared to conventional solvent extraction methods making use of acids and/or organic solvent of medium polarity. The main advantages of PLE over conventional solvent extraction are: (i) the possibility to extract quantitatively DPhT and MPhT from sediments, which could not be done by a solvent extraction approach; (ii) to preserve the structural integrity of the organotin compounds; (iii) to reduce the extraction time from several hours in case of solvent extraction techniques to just 30 min. For spiked sediments, limits of detection ranged from 0.7 to 2 ng/g of tin according to the compound. The relative standard deviations were found to be between 8 and 15%. The developed analytical procedure was validated using a reference material and was applied to various environmental samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号