1.
2.
The solvation parameter model is used to characterize the retention properties of four application-specific open-tubular columns (Rtx-CLPesticides, Rtx-OPPesticides, Rtx-Dioxin and Rtx-Dioxin2) at five equally spaced temperatures over the range 60-140 degrees C. Cluster analysis is used to compare the system constants to a database of forty open-tubular columns characterized according to the same method. System constants differences and retention factor correlation plots are then used to determine selectivity differences between the application-specific columns and their nearest neighbors identified by cluster analysis. The Rtx-CLPesticides and Rtx-OPPesticides columns are shown to belong to the selectivity group containing poly(dimethylmethyltrifluoroprpylsiloxane) stationary phases with Rtx-OPPesticides having a similar selectivity to a poly(dimethylmethyltrifluoropropylsiloxane) stationary phase containing 20% methyltrifluoropropylsiloxane monomer (DB-200) and Rtx-CLPesticides separation properties for a stationary phase containing less than 20% methyltrifluoropropylsiloxane monomer. The Rtx-Dioxin and Rtx-Dioxin2 columns are located in the selectivity group dominated by the poly(dimethyldiphenylsiloxane) stationary phases containing less than 20% diphenylsiloxane monomer. The Rtx-Dioxin and Rtx-Dioxin2 columns are shown to be selectivity equivalent to a (5% phenyl) carborane-siloxane copolymer stationary phase (Stx-500) and a second generation silarylene-siloxane copolymer stationary phase containing dimethylsiloxane and diphenylsiloxane monomers (DB-XLB), respectively.  相似文献   

3.
The solvation parameter model is used to characterize the selectivity of DB-608 and DB-624 open-tubular columns at five equally spaced temperatures over the range 60 to 140 degrees C. The system constants for the DB-608 and DB-624 columns were used as selectivity parameters to search a database of open-tubular columns to identify columns with similar selectivity. The search was refined using the absolute deviation of the system constants and retention factor regression models for varied compounds. For method development it is shown that the selectivity of the poly(cyanopropylphenyldimethylsiloxane) stationary phase containing 6% cyanopropylphenylsiloxane monomer (DB-1301) is equivalent to DB-624 and the poly(dimethyldiphenylsiloxane) stationary phases containing either 50 or 65% diphenylsiloxane monomer (Rtx-50 and Rtx-65) are suitable choices for DB-608.  相似文献   

4.
The solvation parameter model is used to characterize the separation characteristics of two application-specific open-tubular columns (Rtx-Volatiles and Rtx-VGC) and a general purpose column for the separation of volatile organic compounds (DB-WAXetr) at five equally spaced temperatures over the range 60-140 degrees C. System constant differences and retention factor correlation plots are then used to determine selectivity differences between the above columns and their closest neighbors in a large database of system constants and retention factors for forty-four open-tubular columns. The Rtx-Volatiles column is shown to have separation characteristics predicted for a poly(dimethyldiphenylsiloxane) stationary phase containing about 16% diphenylsiloxane monomer. The Rtx-VGC column has separation properties similar to the poly(cyanopropylphenyldimethylsiloxane) stationary phase containing 14% cyanopropylphenylsiloxane monomer DB-1701 for non-polar and dipolar/polarizable compounds but significantly different characteristics for the separation of hydrogen-bond acids. For all practical purposes the DB-WAXetr column is shown to be selectivity equivalent to poly(ethylene glycol) columns prepared using different chemistries for bonding and immobilizing the stationary phase. Principal component analysis and cluster analysis are then used to classify the system constants for the above columns and a sub-database of eleven open-tubular columns (DB-1, HP-5, DB-VRX, Rtx-20, DB-35, Rtx-50, Rtx-65, DB-1301, DB-1701, DB-200, and DB-624) commonly used for the separation of volatile organic compounds. A rationale basis for column selection based on differences in intermolecular interactions is presented as an aid to method development for the separation of volatile organic compounds.  相似文献   

5.
The solvation parameter model is used to study the influence of temperature and composition on the selectivity of nine poly(siloxane) and two poly(ethylene glycol) stationary phase chemistries for open-tubular column gas chromatography. A database of system constants for the temperature range 60-140 degrees C was constructed from literature values with additional results determined for HP-50+, DB-210, DB-1701, DB-225 and SP-2340 columns. The general contribution of monomer composition (methyl, phenyl, cyanopropyl, and trifluoropropyl substituents) on the capacity of poly(siloxane) stationary phases for dispersion, electron lone pair, dipole-type and hydrogen-bond interactions is described. The selectivity coverage of the open-tubular column stationary phases is compared with a larger database for packed column stationary phases at a reference temperature of 120 degrees C. The open-tubular column stationary phases provide reasonable coverage of the range of dipole-type and hydrogen-bond base interactions for non-ionic packed column stationary phases. Deficiencies are noted in the coverage of electron lone pair interactions. None of the open-tubular column stationary phases are hydrogen-bond acids. The system constants are shown to change approximately linearly with temperature over the range 60-140 degrees C. The intercepts and slopes of these plots are used to discuss the influence of temperature on stationary phase selectivity.  相似文献   

6.
The solvation parameter model is used to characterize the retention properties of a poly(methylphenylsiloxane) column Rxi-50 over the temperature range 60-240 degrees C. The smooth variation of the system constants with temperature affords a general picture of how the relative importance of the different intermolecular interactions change with temperature. The system constants and retention factors for varied compounds are compared with those for Rtx-50 prepared with a similar stationary phase but using a different surface deactivation technique. The two columns are shown to be nearly selectivity equivalent. The Rtx-50 column is slightly more cohesive, dipolar/polarizable and hydrogen-bond basic than Rxi-50, while Rxi-50 is slightly more electron lone pair attractive and hydrogen-bond acidic. Only the difference in hydrogen-bond acidity can be identified with some certainty as related to the difference in deactivation processes. For compounds with a separation greater than 0.2 retention factor units on Rtx-50, it should be relatively straightforward to achieve an acceptable separation for the same compounds on Rxi-50.  相似文献   

7.
The suitability of various materials for messenger RNA isolation and possible fractionation was examined by comparing the chromatographic behaviour of synthetic poly(riboadenylic acid) [poly(A)] and ribosomal RNA on each suport. The ratios of poly(A) to ribosomal RNA capacities of the various materials under different chromatographic conditions were used to estimate the potential selectivity of the columns for messenger RNA isolation. Using this criterion, benzoylated cellulose and oligo(deoxythymidylate)-cellulose should be the most selective materials of those studied. The elution conditions (temperature or salt gradient) used to obtain bound poly(A) were investigated to determine the optimum conditions for possible messenger RNA fractionation. It is concluded that oligo(deoxythymidylate)-cellulose appears to be the most suitable support of those investigated for messenger RNA isolation and possible fractionation.  相似文献   

8.
A database of system constants for 32 open-tubular columns at 100 degrees C is used to identify stationary phases for obtaining a wide selectivity space in comprehensive GC. Three parameters based on the Euclidean distance (D-parameter) or vectors (d-parameter and costheta) in hyperspace are used to establish the chemical similarity and retention correlation as an inverse scale of selectivity differences. It is shown that the poly(methyloctylsiloxane) stationary phase is the best candidate for a low-selectivity stationary phase and affords a wider selectivity space when combined with a selective polar stationary phase than poly(dimethylsiloxanes). The most suitable polar stationary phases are poly(ethylene glycols) or bis(cyanopropylsiloxane-co-silarylenes and to a lesser extent poly(methyltrifluoropropylsiloxanes). No systems are truly orthogonal but angles between individual stationary phase vectors of about 75 degrees are possible by choosing the correct combination of stationary phases.  相似文献   

9.
Malik A 《Electrophoresis》2002,23(22-23):3973-3992
The development of sol-gel open-tubular column technology in capillary electrochromatography (CEC) is reviewed. Sol-gel column technology offers a versatile means of creating organic-inorganic hybrid stationary phases. Sol-gel column technology provides a general approach to column fabrication for microseparation techniques including CEC, and is amenable to both open-tubular and monolithic columns. Direct chemical bonding of the stationary phase to the capillary inner walls provides enhanced thermal and solvent stability to sol-gel columns. Sol-gel stationary phases inherently possess higher surface area, and thus provide an effective one-step alternative to conventional open-tubular column technology. Sol-gel column technology is applicable to both silica-based and transition metal oxide-based hybrid stationary phases, and thus, provides a great opportunity to utilize advanced material properties of a wide range of nontraditional stationary phases to achieve enhanced selectivity in analytical microseparations. A wide variety of stationary phase ligands can be chemically immobilized on the capillary inner surface using a single-step sol-gel procedure. Sol-gel chemistry can be applied to design stationary phases with desired chromatographic characteristics, including the possibility of creating columns with either a positive or a negative charge on the stationary phase surface. This provides a new tool to control electroosmotic flow (EOF) in the column. Column efficiencies on the order of half a million theoretical plates per meter have been reported for sol-gel open-tubular CEC columns. The selectivity of sol-gel stationary phases can be easily fine-tuned by adjusting the composition of the coating sol solution. Open-tubular columns have significant advantages over their packed counterparts because of the simplicity in column making and hassle-free fritless operation. Open-tubular CEC columns possess low sample capacity and low detection sensitivity. Full utilization of the analytical potential of sol-gel open-tubular columns will require a concomitant development in the area of high-sensitivity detection technology.  相似文献   

10.
Summary Two new kinds of crown ethers: 3,5-dibutyl-unsymmetrydibenzo-14-crown-4-dihydroxy (cis-, and trans-) with the OH-terminal silicone oil in different proportion were coated on glass capillary columns, and immobilized by condensation using a coupling agent of alkyltrimethoxysilane. Chromatographic characteristics, including column efficiency, polarity, selectivity, phase transition temperature and thermal stability were studied. The columns were compared with PEG-20M in terms of polarity and selectivity. The immobilization and retention mechanisms are also discussed.  相似文献   

11.
Amphiphilic and hydrophilic oligomers were synthesized and coated on fused silica capillaries using a sol-gel technique. Sol-gel-coated capillaries were evaluated for the solid-phase microextraction and preconcentration of a wide variety of non-polar and polar analytes. Both types of coatings were stable under high temperature (up to 280 degrees C). The extraction efficiency of the sol-gel coatings was evaluated for the extraction of both non-polar and polar analytes, including organochlorine pesticides, triazine herbicides, estrogens and alkylphenols (APs) and bisphenol-A (BPA). Compared with commercially available solid-phase microextraction (SPME) adsorbents such as poly(dimethylsiloxane)divenylbenzene and polyacrylate, the new materials showed comparable selectivity and sensitivity towards both non-polar and polar analytes. The new coatings gave good linearity and detection limits. For example with triazines, a detection limit of <0.005 microl l(-1), precision from 5.0 to 11.0% (n = 6) and linearity of the calibration plots (0.5 to 50 microl l(-1)) were obtained. The sol-gel coated SPME capillaries were used for the determination of triazine herbicides in reservoir water samples collected in Singapore.  相似文献   

12.
The solvation parameter model is used to study differences in selectivity for poly(ethylene glycol) stationary phases for packed column (Carbowax 20M) and fused-silica, open-tubular column (HP-20M, AT-Wax, HP-INNOWax and DB-FFAP) gas chromatography. All phases are dipolar, strongly hydrogen-bond basic with no hydrogen-bond acidity and of moderate cohesion. No two phases are exactly alike, however, and selectivity differences identified with cavity formation and dispersion interactions, n- and pi-electron pair interactions, dipole-type interactions and hydrogen-bond interactions are quantified by differences in the system constants at a fixed temperature where retention occurs solely by gas-liquid partitioning. The system constants vary linearly with temperature over the range 60-140 degrees C (except for n- and pi-electron pair interactions which are temperature invariant) facilitating a general comparison of the importance of temperature on selectivity differences for compared phases. From a mechanistic point of view it is demonstrated that selectivity differences can result from chemical differences between the poly(ethylene glycol) stationary phases and from differences in the relative contribution of interfacial adsorption to the retention mechanism. The latter depends on both system properties and solute characteristics.  相似文献   

13.
Wang Y  Zeng Z  Guan N  Cheng J 《Electrophoresis》2001,22(11):2167-2172
A novel open-tubular capillary electrochromatography (OT-CEC) column coated with 2,6-dibutyl-beta-cyclodextrin (DB-beta-CD) was prepared using sol-gel technique. In the sol-gel approach, owing to the three-dimensional network of sol-gel and the strong chemical bond between the stationary phase and the surface of capillary columns, good chromatographic characteristics and unique selectivity in separating isomers were shown. We achieved high efficiencies of 5-14 x 10(4) plates/m for the isomeric nitrophenols using the sol-gel-derived DB-beta-CD columns. The migration time reproducibility of the separation of the isomeric nitrophenols was better than 2.2% over five runs and 4.5% from column to column. These sol-gel-coated DB-beta-CD columns have shown improved separations of isomeric aminophenols, isomeric dihydroxybenzenes and isomeric nitrophenols, in comparison with the sol-gel matrix capillary column. The influences of buffer pH and methanol solvent on separation were investigated. The chiral resolution of enantiomers such as ibuprofen and binaphthol was explored primarily.  相似文献   

14.
Our group recently reported on the application of protein-doped monolithic silica columns for immobilized enzyme reactor chromatography, which allowed screening of enzyme inhibitors present in mixtures using mass spectrometry for detection. The enzyme was immobilized by entrapment within a bimodal meso/macroporous silica material prepared by a biocompatible sol-gel processing route. While such columns proved to be useful for applications such as screening of protein-ligand interactions, significant amounts of entrapped proteins leached from the columns owing to the high proportion of macropores within the materials. Herein, we describe a detailed study of factors affecting the morphology of protein-doped bioaffinity columns and demonstrate that specific pH values and concentrations of poly(ethylene glycol) can be used to prepare essentially mesoporous columns that retain over 80% of initially loaded enzyme in an active and accessible form and yet still retain sufficient porosity to allow pressure-driven flow in the low μL/min range. Using the enzyme γ-glutamyl transpeptidase (γ-GT), we further evaluated the catalytic constants of the enzyme entrapped in capillary columns with different silica morphologies as a function of flowrate and backpressure using the enzyme reactor assay mode. It was found that the apparent activity of the enzyme was highest in mesoporous columns that retained high levels of enzyme. In such columns, enzyme activity increased by ∼2-fold with increases in both flowrate (from 250 to 1000 nL/min) and backpressure generated (from 500 to 2100 psi) during the chromatographic activity assay owing to increases in kcat and decreases in KM, switching from diffusion controlled to reaction controlled conditions at ca. 2000 psi. These results suggest that columns with minimal macropore volumes (<5%) are advantageous for the entrapment of soluble proteins for bioaffinity and bioreactor chromatography.  相似文献   

15.
Nivens DA  Schiza MV  Angel SM 《Talanta》2002,58(3):543-550
Organo-silica sol-gel membranes have been prepared and demonstrated in a single layer format for pH measurement and multiple-layer format for both carbon dioxide and ammonia. The sensors are simple and versatile since the same chemistry and membranes are used for each sensor. The sensors use hydroxypyrenetrisulfonic acid (HPTS) as the indicator immobilized in a base-catalyzed sol-gel containing poly(dimethyl)siloxane, aminopropyltriethoxysilane (APTES) and tetraethylorthosilicate (TEOS). This indicator gel is over coated with a hydrophobic sol-gel to reduce cross reactivity to pH when either CO(2) or NH(3) are examined. The gels are very stable and the sensors retain response up to a 12-month period. Sensors can be stored in buffer or dry without loss of function and have response times to that are comparable to literature values.  相似文献   

16.
Yang W  Sun X  Pan T  Woolley AT 《Electrophoresis》2008,29(16):3429-3435
Developments in biology are increasing demands for rapid, inexpensive, and sensitive biomolecular analysis. In this study, polymer microdevices with monolithic columns and electrophoretic channels were used for biological separations. Glycidyl methacrylate-co-ethylene dimethacrylate monolithic columns were formed within poly(methyl methacrylate) microchannels by in situ photopolymerization. Flow experiments in these columns demonstrated retention and then elution of amino acids under conditions optimized for sample preconcentration. To enhance analyte selectivity, antibodies were immobilized on monoliths, and subsequent lysozyme treatment blocked nonspecific adsorption. The enrichment capability and selectivity of these affinity monoliths were evaluated by purifying fluorescently tagged amino acids from a mixture containing green fluorescent protein (GFP). Twenty-fold enrichment and 91% recovery were achieved for the labeled amino acids, with a >25 000-fold reduction in GFP concentration, as indicated by microchip electrophoresis analysis. These devices should provide a simple, inexpensive, and effective platform for trace analysis in complex biological samples.  相似文献   

17.
溶胶-凝胶法制备高热稳定性的毛细管气相色谱柱   总被引:1,自引:0,他引:1  
毛细管气相色谱柱的传统制备工艺都较为复杂,周期较长,同时固定相和石英毛细管内壁间通常并无化学键生成,在较高温度下使用时固定相的流失严重,导致这类色谱柱的最高允许使用温度不很高.溶胶-凝胶法是一种快速有效的制备色谱柱的新技术,近年来经常应用于高效液相色谱、毛细管电色谱和固定相微萃取等分析化学的许多领域.在气相色谱方面,溶胶-凝胶端羟基聚硅氧烷柱、溶胶-凝胶聚乙二醇柱和溶胶-凝胶开链冠醚柱已相继制备出来,在用溶胶-凝胶  相似文献   

18.
The polarity of carbon layer open tubular (CLOT) columns coated with a layer of non-porous graphitized carbon black (Carbopack B) modified with an appropriate amount of polar polyglycol liquid phase has been evaluated and compared with that of standard polar (Supelcowax-10) and non-polar (SPB-1) bonded phase open tubular columns. The efficiency and selectivity were measured at various temperatures and the polarity of the columns was evaluated by use of McReynolds' constants and the difference in apparent carbon number, ΔC of linear alkanes and alcohols. The polarity of the CLOT column was found to depend on temperature, and changing the analytical conditions therefore enabled the separation of compounds of different polarity whose reciprocal position and resolution were affected by temperature. The application of calculation methods which enable programmed temperature retention times to be predicted from isothermal data was also found to be possible when the polarity of the CLOT column changes with temperature.  相似文献   

19.
The paper describes the development of a very simple method to prepare samples of canned food (beverages, fruits and vegetables) for the determination of bisphenol A by isocratic HPLC with fluorescence detection. The new sample preparation method makes use of the selectivity of bisphenol A antibodies immobilized in a silica matrix by an inexpensive and simple sol-gel technique. In spite of applying highly complex food matrices, immunoaffinity columns could be used for clean-up of at least 15 real samples. Limits of detection (S/N=3) ranged from 0.1 ng/ml for beverages to 4.3 ng/g for vegetables.  相似文献   

20.
Structure-switching, fluorescence-signaling DNA and RNA aptamers have been reported as highly versatile molecular recognition elements for biosensor development. While structure-switching DNA aptamers have been utilized for solid-phase sensing, equivalent RNA aptamers have yet to be successfully utilized in solid-phase sensors due to their lack of chemical stability and susceptibility to nuclease attack. In this study, we examined entrapment into sol-gel derived organic-inorganic composite materials as a platform for immobilization of structure-switching fluorescence-signaling RNA aptamer reporters, using both the synthetic theophylline- and naturally occurring thiamine pyrophosphate-binding RNA aptamers as test cases. Structure-switching versions of both aptamers were entrapped into a series of sol-gel derived composites, ranging from highly polar silica to hydrophobic methylsilsesquioxane-based materials, and the target-binding and signaling capabilities of these immobilized aptamers were assessed relative to solution. Both immobilized aptamers demonstrated sensitivity and selectivity similar to that of free aptamers when entrapped in a composite material derived from 40% (v/v) methyltrimethoxysilane/tetramethoxysilane. Importantly, this material also conferred protection from nuclease degradation and imparted long-term chemical stability to the RNA reporter systems. Given the versatility of sol-gel entrapment for development of biosensors, microarrays, bioaffinity columns, and other devices, this entrapment method should provide a useful platform for numerous solid-phase RNA aptamer-based devices.  相似文献   