1.
The use of two modes for mass spectrometry (MS) detection with an ion trap instrument, selected ion storage (SIS) and tandem mass spectrometry (MS/MS), are compared for the solid-phase microextraction (SPME)–gas chromatography (GC) coupled to mass spectrometry (GC-MS) determination of 16 priority organochlorine pesticides (OCPs) in drinking water samples at the ultratrace levels (ng?L?1) required by official guidelines in the European legislation. Experimental parameters investigated for the SPME sample preparation were: the type of coating (100?µm polydimethylsiloxane, PDMS, and 65?µm poly(dimethylsiloxane)–divinylbenzene, PDMS/DVB), SPME modality, extraction and desorption times and desorption temperature and the methanol percentage in the SPME working solution. Under the calculated optimal conditions two methodologies were developed, one for SIS and the other for MS/MS modes. The detection limits, precision and accuracy were evaluated for both alternatives and were appropriate to the official guidelines requirements. The SPME–GC-MS(SIS) methodology offered LODs from 0.2–6.6?ng?L?1, precision below 13% and recoveries between 83 and 110%. The SPME–GC–MS/MS methodology provided limits of detection (LODs) ranging from 0.3 to 7.6 ng?L?1, % RSD were ≤14% and recoveries of 79–108% were achieved. After the results observed within an Interlaboratory Exercise, the latest MS methodology was selected for the pursued analysis in real drinking water samples. Also, the good results in this round-robin exercise validate the proposed SPME–GC–MS/MS methodology.  相似文献   

2.
Alkylthiols are very reactive and highly volatile compounds, and thus it is difficult to determine these in the water phase. In the present work, an in situ derivatization step prior to solid-phase microextraction (SPME) has been developed for their determination in water samples. The dinitrobenzylation reaction was selected because the high chemical stability of the corresponding thioethers formed provides a significant increase in the distribution coefficient between the SPME fibre and the aqueous phase, and a potential increase in the selectivity and sensitivity. Therefore, different derivatization reaction conditions (i.e. pH, temperature, reaction time and derivatizating reagent concentration) have been studied. Then, the main parameters affecting to the SPME process, that is coating selection, extraction time profile, extraction and desorption temperatures, have been optimized. Finally, a method based on a simple 2,4-dinitrophenylation reaction at pH 8–10, in 60?min at 75°C, coupled to direct SPME using PDMS-DVB fibres at 30°C for 45?min is proposed. The performance of the method provided a good linearity and precision data, and the detection limits were in the low ng?L?1 level.  相似文献   

3.
A headspace solid phase microextraction coupled to gas chromatography with electron capture detector (HS-SPME-GC-ECD) method was optimized for the determination of seven chlorophenols (CPs) with different levels of chlorination. This is the first time that HS-SPME-GC-ECD with acetylation of the analytes is used for the simultaneous determination of CPs in water samples. The influence of fibre type, derivatization conditions, salt addition, temperature and time of extraction and temperature of desorption was checked. Possible sources of contamination and analyte losses were considered. The best results were obtained with the polydimethylsiloxane/divinylbenzene fibre, derivatization by acetylation using 100 μL of acetic anhydride and 0.1 g of anhydrous sodium carbonate per 10 mL of sample, salt addition of 100 g L−1 sodium chloride, extraction at 70 °C for 60 min and desorption in the GC injector at 260 °C for 6 min. The limits of detection (LOD) for monochlorophenols were 12 and 122 ng L−1 for 2-chlorophenol and 4-chlorophenol, respectively. For polychlorinated CPs, the LODs were lower than 6 ng L−1, values similar to the existing methods that use SPME with derivatization for CPs determination in water samples. The method is suitable for the determination of CPs in most environmental aqueous samples. Repeatability and reproducibility were less than 16.8% and 11.7%, respectively. The optimized method was successfully applied for the analysis of waters with complex matrices such as river and estuarine water samples.  相似文献   

4.
A reliable and sensitive method for simultaneous determination of perchloroethylene (PCE), trichloroethylene (TCE), and trichloroacetic acid (TCA) in human urine by gas chromatography-mass spectrometry (GC/MS) is described after extraction and preconcentration by a new solid-phase microextraction (SPME) adsorbent. The potential of single-walled carbon nanotubes (SWCNTs) as SPME adsorbent for the pre-concentration of environmental pollutants has been investigated in recent years. This work was carried out to investigate the feasibility of SWCNTs as a headspace SPME adsorbent for the determination of chloroethylenes in human urine. SWCNTs were attached onto a stainless steel wire through an organic binder. Potential factors affecting the extraction efficiency, including extraction time, extraction temperature, desorption time, desorption temperature, and salinity were optimized. The developed method showed good performance. For PCE and TCE, calibration curves were linear (r 2 ?≥?0.994) over the concentration ranges from 15 to 8000?ng?L?1 and the limit of detection (LOD) at signal-to-noise (S/N) ratio of 3 was 5?ng?L?1. The analytical procedure also involves derivatization of TCA with dimethyl sulfate, before headspace sampling. For TCA the linear range and LOD were 45-8000 (r 2 ?≥?0.992) and 15?ng L?1, respectively. In addition, a comparative study between the SWCNT and a commercial carboxen/polydimethylsiloxane (CAR/PDMS) SPME fibre for the determination of chloroethylenes in human urine was carried out. SWCNT fibre showed higher extraction capacity, better thermal stability (over 350°C) and longer life span (over 200 times) than the commercial CAR/PDMS fibre. The developed method was successfully applied to determine chloroethylenes in human urine samples. As the results indicated, the mean concentrations of TCE, PCE and TCA in exposed workers (dry-cleaning industry workers) were significantly greater than that of control group.  相似文献   

5.
Ultrahigh performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) was utilized to develop a rapid, sensitive and reliable method without solid phase extraction (SPE) pre-concentration for trace analysis of 11 pharmaceuticals and personal care products (PPCPs) in in?uent and ef?uent from municipal wastewater treatment plants (WWTPs). This method not only shortened the analysis time but also reduced analysis cost significantly by omitting SPE process and avoiding the consumption of SPE cartridge. Detection parameters for UHPLC–MS/MS analysis were optimized, including sample pH, eluent, mobile phase (solvent and additive), column temperature, and ?ow rate. Under the optimal conditions, all analytes were well separated and detected within 8.0 min by UHPLC–MS/MS. The method quantification limits (MQLs) for the 11 PPCPs ranged from 0.040 to 88 ng L−1 and from 0.030 to 90 ng L−1 for influent and effluent, respectively. The matrix effect was systematically investigated and quantified for different types of samples. The analysis of in?uent and ef?uent samples of two WWTPs in Hong Kong revealed the presence of 11 PPCPs, including acyclovir, benzophenone-3, benzylparaben, carbamazepine, ethylparaben, fluconazole, fluoxetine, methylparaben, metronidazole, propylparaben, and ranitidine. Their concentrations ranged from 9.1 to 1810 ng L−1 in influent and from 6.5 to 823 ng L−1 in effluent samples collected from Hong Kong WWTPs.  相似文献   

6.
The dual nature of the quaternary ammonium compounds, having permanently charged hydrophilic quaternary ammonium heads and long-chain hydrophobic tails, makes the sample preparation step and analysis of these compounds challenging. A high-throughput method based on thin-film solid-phase microextraction (SPME) and liquid chromatography mass spectrometry was developed for simultaneous quantitative analysis of nine benzylic and aliphatic quaternary ammonium compounds. Chromatographic separation and detection of analytes were obtained in reverse-phase mode in 8 min using a triple quadrupole mass spectrometer. Hydrophilic lipophilic balance particle-coated blades were found to be the most suitable among the different coatings tested in terms of recoveries and carryover on the blades. For desorption solvents, 70/30, v/v (A/B) with 0.1 % formic acid (where A is 10 mM ammonium acetate in acetonitrile/water (95/5?, v/v) and B is 0.1 %? (v/v) formic acid in isopropyl alcohol) was shown to be the most efficient solvent for the desorption of the analytes from the SPME sorbent. The SPME method was optimised in terms of extraction, pH, and preconditioning, as well as extraction and desorption times. Optimum conditions were 45 min of extraction time and 15 min of desorption time, all with agitation. The extraction was found to be optimum in a range of pH 6.0 to 8.0, which is consistent with the natural pH of water samples. Wide linear dynamic ranges with the developed method were obtained for each compound, enabling the application of the method for a wide range of concentrations. The developed method was validated according to the Food and Drug Administration criteria. The proposed method is the first SPME-based approach describing the applicability of the high-throughput thin-film SPME in a 96-well system for analysis of such challenging compounds.  相似文献   

7.
This study evaluates solid-phase micro-extraction (SPME) coupled with gas chromatography–mass spectrometry (GC–MS) to determine trace levels of bis-phenol A in water and leached from plastic containers. In our study, we used very thin composite membranes prepared in the laboratory. The extraction using headspace post-derivatization with bis(trimethylsilyl) trifluoroacetamide (BSTFA), containing 1 % trimethylchlorosilane (TMCS) vapor, following SPME was compared with extraction without derivatization. The SPME experimental procedures to extract bis-phenol A in water were optimized with a relatively polar polyacrylate (PA)-coated fiber, an extraction time of 50 min, and desorption at 300 °C for 2 min. Headspace derivatization following SPME was performed using 7 μL of BSTFA with 1 % TMCS at 65 °C for 30 s. The precision was 5.2 % without derivatization and 9.0 % headspace derivatization. The detection limit was determined to be at the nanogram per liter level. When SPME was used following headspace derivatization, the detection limit was one order of magnitude better than that achieved without derivatization. The results of this study reveal the adequacy of the SPME–GC–MS method for analyzing bisphenol A leached from plastic containers. The concentrations of bisphenol A leached from plastic containers into water ranged from 0.7 to 78.5 μg L?1.  相似文献   

8.
In this study, a simple, rapid, and sensitive method was developed and validated for the quantification of valproic acid (VPA), an antiepileptic drug, in human plasma, which was based on water-phase derivatization followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS). In the proposed method, VPA in plasma was rapidly derivatized with a mixture of isobutyl chloroformate, ethanol and pyridine under mild conditions (room temperature, aqueous medium), and the VPA ethyl ester formed was headspace-extracted and simultaneously concentrated using the SPME technique. Finally, the analyte extracted on SPME fiber was analyzed by GC/MS. The experimental parameters and method validations were studied. The optimal conditions were obtained: PDMS fiber, stirring rate of 1100 rpm, sample temperature of 80 degrees C, extraction time of 20 min, NaCl concentration of 30%. The proposed method had a limit of quantification (0.3 microg/mL), good recovery (89-97%) and precision (RSD value less than 10%). Because the proposed method combined a rapid water-phase derivatization with a fast, simple and solvent-free sample extraction and concentration technique of SPME, the sample preparation time was less than 25 min. This much shortens the whole analysis time of VPA in plasma. The validated method has been successfully used to analyze VPA in human plasma samples for application in pharmacokinetic studies. All these results show that water-phase derivatization followed by HS-SPME and GC/MS is an alternative and powerful method for fast determination of VPA in biological fluids.  相似文献   

9.
The work aims at developing a simple and rapid method for the quantification of dopamine (DA), serotonin (5-HT) and norepinephrine (NE) in human urine. The urinary levels of these biogenic amines can be correlated with several pathological conditions concerning heart disease, stress, neurological disorders and cancerous tumors. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography–triple quadrupole mass spectrometry (GC–QqQ-MS) after a fast derivatization of both aliphatic amino and phenolic moieties by propyl chloroformate. The variables influencing the derivatization reaction were reliably optimized by the multivariate approach of “Experimental design”. The optimal conditions were obtained by performing derivatization with 100 μL of propyl chloroformate and 100 μL of pyridine. The extraction ability of five commercially available SPME fibers was evaluated in univariate mode and the best results were obtained using the polyacrylate fiber. The variables affecting the efficiency of SPME analysis were again optimized by the multivariate approach of “Experimental design” and, in particular, a central composite design (CCD) was applied. The optimal values were extraction in 45 min at room temperature, desorption temperature at 300 °C, no addition of NaCl. Assay of derivatized analytes was performed by using a gas chromatography–triple quadrupole mass spectrometry (GC–QqQ-MS) system in selected reaction monitoring (SRM) acquisition. An evaluation of all analytical parameters demonstrates that the developed method provides satisfactory results. Indeed, very good linearities were achieved in the tested calibration range with correlation coefficient values of 0.9995, 0.9999 and 0.9997 for DA, 5-HT and NE, respectively. Accuracies and RSDs calculated for between-run and tested at concentrations of 30, 200, and 800 μg L−1 were in the range from 92.8% to 103.0%, and from 0.67 to 4.5%, respectively. Finally, the LOD values obtained can be considered very good (0.587, 0.381 and 1.23 μg L−1 for DA, 5-HT and NE, respectively).  相似文献   

10.
A gas chromatography–mass spectrometry (GC–MS) method was investigated for the simultaneous analysis of two types of endocrine disrupting compounds (EDCs), i.e., alkylphenol ethoxylates and brominated flame retardants (BFRs), by extraction and derivatization followed by GC–MS. Different solid phase extraction (SPE) cartridges (Cleanert PestiCarb, C18, Cleanert-SAX and Florosil), solvents (toluene, tetrahydrofuran, acetone, acetonitrile and ethyl acetate) and bases (NaHCO3, triethylamine and pyridine) were tested and the best chromatographic analysis was achieved by extraction with Strata-X (33?μm, Reverse Phase) cartridge and derivatization with heptafluorobutyric anhydride at 55?°C under Na2CO3 base in hexane. It was observed that APE together with lower substituted PBBs (PBB1, PBB10, PBB18 and PBB49), HBCD and TBBPA can be determined simultaneously under the same GC conditions. This simple and reliable analytical method was applied to determining trace amounts of these compounds from wastewater treatment plant samples. The recoveries of the target compounds from simulated water were above 60?%. The limit of detection ranged from 0.01 to 0.15?μg L?1 and the limit of quantification ranged from 0.05 to 0.66?μg L?1. There were no appreciable differences between filtered and unfiltered wastewater samples from Leeuwkil treatment plant although concentration of target analytes in filtered influent was slightly lower than the concentration of target analytes in unfiltered influent water. The concentrations of the target compounds from the wastewater treatment were determined from LOQ upwards.  相似文献   

11.
A method based on solid-phase microextraction (SPME) followed by on-fiber derivatization and gas chromatography–mass spectrometry detection (GC–MS) for determination of phenol in air was developed. Three different types of SPME fibers, polar and non-polar poly(dimethylsiloxane) (PDMS) and polyethylene glycol (PEG) were synthesized using sol–gel technology and their feasibility to the sampling of phenol were investigated. Different derivatization reagents for post on-fiber derivatization of phenol were studied. Important parameters influencing the extraction and derivatization process such as type of fiber coating, type and volume of derivatizing reagent, derivatization time and temperature, extraction time, and desorption conditions were investigated and optimized. The developed method is rapid, simple, easy and inexpensive and offers high sensitivity and reproducibility. Under the optimized conditions, the detection limit of the method was 5 ng L−1 using selected ion monitoring (SIM) mode. The inter-day and intra-day precisions of the developed method under optimized conditions were below 10%, and the method shows linearity in the range of 20 ng L−1 to 500 μg L−1with the correlation coefficient of >0.99. The optimized method was applied to the sampling of phenol from some biologics production areas. The compared results obtained using current and standard methods were shown to be satisfactory.  相似文献   

12.
A rapid and simple large volume headspace (HS) sampling technique termed headspace solid-phase microcolumn extraction (HS-SPMCE) is described. HS gas above a liquid or solid sample is aspirated by attaching a gas-tight syringe onto a glass thermal desorption tube filled with Tenax sorbent. The trapped analytes are recovered by thermal desorption for gas chromatography–mass spectrometry (GC–MS) analysis. Benzene, toluene, ethylbenzene and the xylene isomers (BTEX) are used as model compounds to demonstrate the application of the extraction procedure for water samples. The results of the tests of the effect of agitation time and aspiration rate on recovery of the analytes show a good robustness of the method. BTEX are determined in the linear range from 0.5 to 50.0 μg L?1 with limits of detection (3 σ) ranging within 0.09–0.14 μg L?1 (MS was in scan mode). The method provides a good repeatability (RSD < 9%) and only a negligible carryover effect was observed ( ≤0.05%) when analysing BTEX at concentration 50.0 μg L?1.  相似文献   

13.
This study demonstrates the potential of bamboo charcoal as a novel and inexpensive solid-phase microextraction (SPME) coating material for enrichment and determination of organic pollutants in water samples. Bamboo charcoal was prepared and used as a SPME coating material. Eleven phthalate esters (PAEs) were used as model analytes, and gas chromatography–mass spectrometry was used for separation and detection. Important extraction conditions (ionic strength, stirring rate, and extraction time) and desorption conditions (desorption temperature and time) were systematically investigated and optimized. Linearity of 0.1–100 μg?L?1 and correlation coefficients of 0.9992–0.9998 were obtained under optimum conditions. Inter-day and intra-day repeatability were 2.15–9.93 % and 1.89–9.85 %, respectively, and fiber-to-fiber reproducibility was 5.42–9.66 %. On the basis of a chromatographic signal-to-baseline noise ratio of three, the limits of detection reached 0.004–0.023 μg?L?1. Satisfactory results were achieved when the bamboo coating was used for determination of 11 PAEs in real water samples. The experimental results indicate that bamboo charcoal has significant potential as a SPME coating material for rapid enrichment and sensitive determination of organic pollutants in environmental samples.  相似文献   

14.
A novel organic–inorganic composite-coated fiber was developed for selective solid-phase microextraction (SPME) by direct electrodeposition of zinc oxide microparticles on a pretreated stainless steel wire followed by self-assembly of hydroxyundecanethiol with zinc–sulfur bonds. The performance of the hydroxyundecyl-modified zinc oxide-coated steel fiber was then assessed for SPME of polar aromatic compounds coupled to high-performance liquid chromatography with ultraviolet detection. Excellent extraction and selectivity were obtained for polycyclic aromatic hydrocarbons. The extraction and desorption times, temperature, stirring rate, and ionic strength were optimized. The limits of detection were from 0.034 to 0.132?µg?L?1. The relative standard deviations were from 3.4 to 4.9% for a single fiber and from 5.1 to 6.4% for multiple fibers. The recovery of polycyclic aromatic hydrocarbons in environmental water fortified at 5.0 and 50?µg?L?1 was from 83.1 to 103% with relative standard deviations below 8.4%. This fiber was shown to withstand at least 200 extraction and desorption cycles. The method was used for the preconcentration and determination of polycyclic aromatic hydrocarbons in environmental water.  相似文献   

15.
A new method for the simultaneous determination of 12 volatile organic compounds (trans-1,2-dichloroethene, 1,1,1-trichloroethane, benzene, 1,2-dichloroethane, trichloroethene, toluene, 1,1,2-trichloroethane, tetrachloroethene, ethylbenzene, m-, p-, o-xylene) in water samples by headspace solid phase microextraction (HS–SPME)–gas chromatography mass spectrometry (GC–MS) was described, using a 100?µm PDMS (polydimethylsiloxane) coated fibre. The response surface methodology was used to optimise the effect of the extraction time and temperature, as well as the influence of the salt addition in the extraction process. Optimal conditions were extraction time and temperature of 30?min and ?20°C, respectively, and NaCl concentration of 4?mol?L?1. The detection limits were in the range of 1.1?×?10?3–2.3?µg?L?1 for the 12 volatile organic compounds (VOCs). Global uncertainties were in the range of 4–68%, when concentrations decrease from 250?µg?L?1 down to the limits of quantification. The method proved adequate to detect VOCs in six river samples.  相似文献   

16.
A novel sampling device based on the partition of target analytes to the extraction medium was developed for the determination of sesquiterpenes in air samples. The extraction medium was prepared by the chemical derivatization of a specially prepared macroporous silica, with a specific surface area of 2.0 m2/g. Taking advantage of the sample extraction, which was mainly based on the partition of sesquiterpenes between air and a C18‐bonded phase, the extracted analytes were rapidly and quantitatively desorbed just by passing a small amount of desorption solvent for subsequent analysis by gas chromatography with mass spectrometry. Several experimental conditions, such as the sampling volume and temperature, were systematically evaluated. Under optimized conditions, desorption of the extracted analytes was completed within 1 min with a desorption efficiency of more than 99.9%, achieved using 5 mL of acetone for all the evaluated sesquiterpenes. The applicability of the developed device was confirmed by the determination of several sesquiterpenes from coniferous trees. Although further improvements of the device are required for collecting large volumes or high‐temperature air samples, the potential of the developed sampling device was confirmed by determining traces of semivolatile organic compounds in air samples.  相似文献   

17.
Self-assembled monolayers (SAMs) of polyaminithiophenol (PATP) were used as a covalent bonded coating for solid-phase microextraction (SPME). Thiolated aniline-analog monomers (mixture of 2- and 3-aminothiophenols, 2/3-ATP) were anchored on the gold surface and then electropolymerized. Due to the strong S?CAu bond, thiol-terminated coating on the gold surface was very stable. The proposed covalent bonded coating showed higher mechanical (re-usability up to 100 times) and thermal stability (up to 320???C) than non-covalent bonded polyaniline coating (re-usability up to 20 times and thermal stability up to 250???C). The extraction capability of the proposed fiber for the extraction of five polycyclic aromatic hydrocarbons (PAHs), including phenanthrene, anthracene, pyrene, 9,10-dimethylanthracene and benzo[??]anthracene was examined. The effects of different parameters influencing the extraction efficiency of analytes including extraction temperature, extraction time, ionic strength, stirring rate and sample volume were examined and optimized. Linear ranges of 1?C250???g?L?1 for phenanthrene and anthracene, and 1?C100???g L?1 for the other compounds were obtained. Detection limits were in the range of 0.1?C0.32???g?L?1. Single fiber repeatability and fiber to fiber reproducibility were less than 8.9 and 15.8%, respectively. Seawater sample was analyzed as real sample and good recoveries (81?C108%) were obtained for target analytes.  相似文献   

18.
Quantification of trace concentrations of transformation products of rocket fuel unsymmetrical dimethylhydrazine (UDMH) in water requires complex analytical instrumentation and tedious sample preparation. The goal of this research was to develop a simple and automated method for sensitive quantification of UDMH transformation products in water using headspace (HS) solid-phase microextraction (SPME) in combination with GC-MS and GC-MS/MS. HS SPME is based on extraction of analytes from a gas phase above samples by a micro polymer coating followed by a thermal desorption of analytes in a GC inlet. Extraction by 85 µm Carboxen/polydimethylsiloxane fiber at 50 °C during 60 min provides the best combination of sensitivity and precision. Tandem mass spectrometric detection with positive chemical ionization improves method accuracy and selectivity. Detection limits of twelve analytes by GC-MS/MS with chemical ionization are about 10 ng L?1. GC-MS provides similar detection limits for five studied analytes; however, the list of analytes detected by this method can be further expanded. Accuracies determined by GC-MS were in the range of 75–125% for six analytes. Compared to other available methods based on non-SPME sample preparation approaches (e.g., liquid–liquid and solid-phase extraction), the developed method is simpler, automated and provides lower detection limits. It covers more UDMH transformation products than available SPME-based methods. The list of analytes could be further expanded if new standards become available. The developed method is recommended for assessing water quality in the territories affected by space activities and other related studies.  相似文献   

19.
A novel solid phase microextraction (SPME) fiber was fabricated by electrospinning method in which a polymeric solution was converted to nanofibers using high voltages. A thin stainless steel wire was coated by the network of polymeric nanofibers. The polymeric nanofiber coating on the wire was mechanically stable due to the fine and continuous nanofibers formation around the wire with a three dimensional structure. Polyamide (nylon 6), due to its suitable characteristics was used to prepare the unbreakable SPME nanofiber. The scanning electron microscopy (SEM) images of this new coating showed a diameter range of 100–200 nm for polyamide nanofibers with a homogeneous and porous surface structure. The extraction efficiency of new coating was investigated for headspace solid-phase microextraction (HS-SPME) of some environmentally important chlorophenols from aqueous samples followed by gas chromatography–mass spectrometry (GC–MS) analysis. Effect of different parameters influencing the extraction efficiency including extraction temperature, extraction time, ionic strength and polyamide amount were investigated and optimized. In order to improve the chromatographic behavior of phenolic compounds, all the analytes were derivatized prior to the extraction process using basic acetic anhydride. The detection limits of the method under optimized conditions were in the range of 2–10 ng L−1. The relative standard deviations (RSD) (n = 3) at the concentration level of 1.7–6.7 ng mL−1 were obtained between 1 and 7.4%. The calibration curves of chlorophenols showed linearity in the range of 27–1330 ng L−1 for phenol and monochlorophenols and 7–1000 ng L−1 for dichloro and trichlorophenols. Also, the proposed method was successfully applied to the extraction of phenol and chlorophenols from real water samples and relative recoveries were between 84 and 98% for all the selected analytes except for 2,4,6 tricholophenol which was between 72 and 74%.  相似文献   

20.
Solid‐phase microextraction (SPME) has been directly coupled to an ion‐trap mass spectrometer (MS) for the determination of the model compound lidocaine in urine, hereby applying MS/MS [fragmentation of [M + H]+ (m/z 235) to a fragment with m/z 86]. The throughput of samples has been increased using non‐equilibrium SPME with polydimethylsiloxane (PDMS) fibers. The effect of temperature on the sorption and the desorption was studied. Elevated temperatures during sorption (65°C) and desorption (55°C) had a considerable influence on the speed of the extraction. The desorption was carried out with a home‐made desorption chamber allowing thermostating. Only 1 min sorption and 1 min desorption were performed, after which MS detection took place, resulting in a total analysis time of 3 min. Detection limits below 1 ng/mL could be obtained despite yields of only 2.1 and 1.5% for a 100‐ and a 30‐μm PDMS‐coated fiber, respectively. Furthermore, the determination of lidocaine in urine had acceptable reproducibilities, i.e., relative standard deviations (RSDs) below 10%. A limit of quantitation (RSD < 15%) of about 1 ng/mL was obtained. No extra wash step of the extraction fiber was required after desorption if a 30‐μm coating was used, whereas not all the analyte was desorbed from the 100‐μm coating in a single desorption. Therefore, the SPME‐MS/MS system with a 30‐μm PDMS‐coated fiber for rapid non‐equilibrium SPME at elevated temperatures has interesting potential for high‐throughput analysis of biological samples.  相似文献   