首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 656 毫秒
1.
A method for direct determination of cadmium, chromium, copper and lead in sediments and soil samples by electrothermal atomic absorption spectrometry using Zr, Ir, etylenediamine acetic acid (EDTA), Zr + EDTA, Ir + EDTA, Zr + Ir and Zr + Ir + EDTA as chemical modifiers in 0.5% (v/v) Triton X-100 plus 0.2% (v/v) nitric acid mixture used as diluent was developed. The effects of mass and mass ratio of modifiers on analytes in sample solutions were studied. The optimum masses and mass ratios of modifiers: 20 microg of Zr, 4 microg of Ir, 100 microg of EDTA and 20 microg of Zr + 4 microg of Ir + 100 microg of EDTA, were used to enhance the analyte signals. Pyrolysis and atomization temperatures, atomization and background absorption profiles, characteristic masses, and detection limits of analytes in samples were compared in the presence or absence of a modifier. The detection limits and characteristic masses of analytes in a 0.5% (m/v) dissolved sample (dilution factor of 200 ml g(-1)) obtained with Zr + Ir + EDTA are 8.0 ng g(-1) and 1.2 pg for Cd, 61 ng g(-1) and 4.3 pg for Cr, 32 ng g(-1) and 23 pg for Cu, and 3.4 ng g(-1) and 19 pg for Pb, respectively. The Zr + Ir + EDTA modifier mixture was found to be preferable for the determination of analytes in sediment and soil-certified and standard reference materials. Depending on the sample type, the percent recoveries of analytes were increased from 81 to 103% by using the proposed modifier mixture; the results obtained are in good agreement with the certified values.  相似文献   

2.
Analyses of ochratoxin A (OTA) and aflatoxins (AFs) in 94 imported beer samples from 31 producing countries and in 22 Japanese beer samples were performed by immunoaffinity column and reversed-phase liquid chromatography (LC) with fluorescence detection. Recoveries of OTA from beer samples spiked at 25 and 250 pg/mL were 86.1 and 88.2%, respectively. Recoveries of AFs were 98.4 and 98.9%, 95.4 and 95.5%, 101.2 and 97.8%, and 98.9 and 96.0%, respectively, from beer samples spiked at 4.1 and 41 pg AF B1, 4.45 and 44.5 pg AF B2, 4.7 and 47 pg AF G1, and 4.65 and 46.5 pg AF G2/mL. Detection limits were 1.0 pg/mL for OTA, 0.5 pg/mL for AFs B1 and B2, and 1.0 pg/mL for AFs G1 and G2. OTA was detected in 86 (91.5%) of 94 imported beer samples at a mean level of 10.1 pg/mL and in 21 (95.5%) of 22 Japanese beer samples at a mean level of 12.5 pg/mL. AF B1 was detected in 11 of 94 imported beer samples at a level of 0.5-83.1 pg/mL and in 2 of 22 Japanese beer samples at 0.5 and 0.8 pg/mL. Except for one beer sample from Peru, the samples contaminated with AFs were also contaminated with OTA. Although OTA was detected in most samples from various countries, AFs were detected in the beer samples from only a limited number of countries where AF contamination might be expected to occur because of their warm climate.  相似文献   

3.
A micellar electrokinetic capillary chromatographic (MEKC) procedure has been developed for the separation and determination of dioxouranium (VI), iron(III), copper(II), and nickel(II) using bis(salicylaldehyde)propylenediimine (H2SA2Pn) as chelating reagent with a total run time of <3 min. Sodium dodecyl sulphate (SDS) was used as micellar medium at pH 8.1 with sodium tetraborate buffer (0.1 M). Uncoated fused silica capillary with effective length 38.8 cmx75 microm id was used with an applied voltage of 30 kV and photo-diode array detection at 228 nm. Linear calibrations were established within 0.045-1000 microg/mL of each element with detection limit within 15-122 ng/mL. The method was applied to the analysis of spring water and rock samples. The presence of uranium in rock and spring water samples was established within 1.58-1739.3 microg/g and 0.047-0.712 microg/mL with relative standard deviation within 0.9-2.1% and 1.3-2.6% respectively. Uranium ore and water samples were also assayed by the standard addition technique. Recovery of uranium was >98% with RSD up to 2.7%. Copper, nickel, and iron in their combined matrix were concurrently determined within RSD 0.6-3.6% (n=5) and the results obtained were compared with those of flame AAS.  相似文献   

4.
A method for the simultaneous determination of 9 pesticides (dinitroanilines, organophosphorus, triazoles, and pyrimidines) in several products (malt, spent grains, wort, and beer) of the beer industry is reported. Solid samples (malt and spent grains) are extracted by homogenization with a water-hexane mixture, and the pesticides are partitioned with dichloromethane. Liquid samples (wort and beer) are extracted by sonication with a hexane-dichloromethane mixture. Determination of pesticide residues was made by capillary gas chromatography with an electron capture detector (ECD). Confirmation of the compounds was performed by gas chromatography/ion trap mass spectrometry in the selected ion monitoring mode. Detection limits for GC-ECD varied from 0.2 to 5.5 pg for trifluralin and malathion, respectively. Recoveries of the pesticides from spiked samples ranged from 81.2 to 113.7% with a relative standard deviation between 3.4-7.5%. The method presents good linearity over the studied range (0.005-2 microg/mL). The proposed method is rapid and reliable and can be useful for routine monitoring during brewing.  相似文献   

5.
Pb(II), Cd(II) and Cu(II) ions were separated and preconcentrated by solid-phase extraction on octadecyl-bonded silica membrane disks modified with a new S–N-containing Schiff base (bis-2-thiophenal propandiamine) (BTPD) followed by elution and atomic absorption spectrometric detection. The method was applied as a separation and detection method for lead(II), cadmium(II) and copper(II) in environmental and biological samples. Extraction efficiency and the influence of sample matrix, flow rate, pH, and type and minimum amount of stripping acid were investigated. The maximum capacity of the membrane disks modified by 4?mg of BTPD was found to be 668 ± 10, 480 ± 8 and 454 ± 7?µg of lead, cadmium and copper, respectively. The limit of detection of the proposed method is 0.25, 0.01 and 0.02?ng/mL for lead, cadmium and copper, respectively.  相似文献   

6.
A coprecipitation method with ytterbium hydroxide was studied for the determination of cadmium in water samples by graphite-furnace atomic absorption spectrometry. Up to 40 ng of cadmium in water samples was quantitatively coprecipitated with ytterbium hydroxide at pH 8.0-11.2. The concentration factor was 100 fold. The coprecipitated cadmium was sensitively determined without any influence of ytterbium and the calibration curve was linear from 0.1 to 4 ng/mL of cadmium. The detection limit (signal/noise = 2) was 2.9 pg/mL in 100 mL of the initial sample solution. Twenty-nine diverse ions tested did not interfere with the determination in at least a 10000-fold mass ratio to cadmium. The proposed method was successfully applied to the determination of cadmium in spring water.  相似文献   

7.
An RP-HPLC method for the separation and determination of aluminium(III), vanadium(V), iron(III), copper(II) and nickel(II) with CALKS (Chromazol KS) and PAR ([4-(2-pyridylazo)resorcinol]) chelating on a YWG-ODS column was developed. A mixture of methanol-tetrahydrofuran(THF)-water (60:5:35 v/v) containing 0.2 mol/L LiCl, 5 x 10(-5) mol/L CALKS, 5 x 10(-5) mol/L PAR and acetate buffer solution (pH 4.9) was selected as mobile phase. The method has high sensitivity, with the detection limits being 6 ng/mL for aluminium(III), 3.5 ng/mL for vanadium(V), 10.4 ng/mL for iron(III), 6.3 ng/mL for copper(II) and 8.7 ng/mL for nickel(II). It also has good selectivity, so that most foreign metal ions do not interfere under the optimum conditions. The method can be applied to the simultaneous determination of trace amounts of aluminium, vanadium, iron, copper and nickel in rice and flour samples.  相似文献   

8.
An analytical procedure has been developed for the separation of dioxouranium(VI), iron(III), copper(II), nickel(II), cobalt(II), cobalt(III), palladium(II), and thorium(IV) by MEKC using N,N'-ethylene bis(salicylaldimine) (H(2)SA(2)en) as a complexing reagent with total runtime <4.5 min. SDS was used as micellar medium at pH 8 with sodium tetraborate buffer (0.1 M). An uncoated fused-silica capillary with an effective length of 50 cm x 75 microm id was used with an applied voltage of 30 kV with photodiode array detection at 231 nm. Linear calibrations were obtained within 0.111-1000 microg/mL of each element with LODs within 37-325 ng/mL. The developed method was tested for analysis of uranium ore samples indicating its presence within 103-1789 microg/g with RSD within 0.79-1.87%. Likewise copper, nickel, and iron in their combined matrix were also simultaneously determined with RSD 0.4-1.6% (n = 6).  相似文献   

9.
Non-dispersive atomic fluorescence spectrometry (NDAFS) coupled with vapor generation (VG) sample introduction was applied to the determination of the concentrations of hazardous heavy metals, such as arsenic, cadmium, lead and mercury, in seawater, soils and total airborne particulate matter (PM) collected around the Xiamen area in China. Almost 100% sample introduction efficiency was achieved by using thiourea and ascorbic acid for the pre-reduction of As(V) to As(III), K3Fe(CN)6 and tartaric acid for pre-oxidation of Pb(II) to Pb(IV), and masking the interferences arising from the co-existing transition metals to As, Cd, Hg and Pb during their vapor generation process. Moreover, a novel sample pretreatment device was developed to avoid the loss of mercury, lead, cadmium and arsenic during sample pretreatment. With such methods, the detection limit (DL) of arsenic, cadmium, lead and mercury was down to 0.08, 0.03, 0.05, 0.01 ng mL(-1) (3sigma), respectively. The relative standard deviations (RSD, n = 11) for arsenic, cadmium, lead and mercury at 10 ng mL(-1) were 0.9%, 1.6%, 1.3% and 2.0%, respectively. The concentrations of hazardous heavy metals in the environmental samples collected in Xiamen, China are in the range from 0.02 +/- 0.001 ng mL(-1) in seawater to 15.3 +/- 0.2 microg g(-1) in soils. Besides flame/GF-AAS and ICP-AES/MS, VG-NDAFS should be another choice for the determination of hazardous heavy metals in environmental samples.  相似文献   

10.
高纯铟样品经盐酸溶解、以阳离子交换树脂分离出痕量铜后,用石墨炉原子吸收光谱法测定铜。研究了溶样方法、离子交换分离和测定铜的条件:用8mL浓盐酸将1g样品溶解;以0.6mol/L盐酸作为淋洗液进行离子交换,可把绝大部分铟基体及样品中痕量的银、砷、镉、硅分离除去,随后用2.0mol/L盐酸把铜洗出并收集之。铝、铁、镁、镍、铅、锡、铊、锌与小于10μg的铟不能与铜分离,但对测定无影响。当称样量为1g,进样量为50μL时,方法线性范围为1~4ng/mL,检出限为0.1ng/mL,测定下限为0.001μg/g,比行业标准方法 YS/T 230.1—2011的0.1μg/g低两个数量级。方法用于实际样品分析,结果与电感耦合等离子体质谱法(ICP-MS)相符,相对标准偏差(RSD,n=8)为1.7%~18.5%,加标回收率为94.8%~115.0%。  相似文献   

11.
A differential pulse polarographic method is proposed for the trace determination of bismuth and copper from large volumes of aqueous samples after adsorption of their 1-(2-thiazolylazo)-2-naphthol complexes onto microcrystalline naphthalene in the pH ranges of 7.2-9.0 and 4.0-7.8, respectively. Bismuth and copper are desorbed from microcrystalline naphthalene with 9 mL 1M HCl. Well-defined peaks are obtained at Ep = -0.09 and -0.20 V versus a saturated calomel electrode, in an HCl-isoquinoline medium as the supporting electrolyte, for bismuth and copper, respectively. Bismuth is reduced reversibly with a 3-electron change, whereas copper is reduced irreversibly under these conditions. The detection limits are 55 ng/mL for bismuth and 91 ng/mL for copper. Linearity is maintained in the concentration ranges of 0.18-13.5 and 0.30-17.3 microg/mL for bismuth and copper, respectively, with corresponding correlation coefficients of 0.9996 and 0.9885. The relative standard deviations are 1.0% for bismuth at 2.0 microg/mL and 1.4% for copper at 5.0 microg/mL. Various parameters were optimized to develop conditions for the determination of these metal ions in various samples.  相似文献   

12.
微波等离子体炬(MPT)是一种具有类似ICP炬管结构的新型等离子体光源,该光源的基本性质已进行了详细的研究。本文采用自制的低功率MPT为激发光源,以氧为工作气体,用微型电热蒸发装置进样,测得铜、锌和镉的检出限分别为3.3、1.4和1.7ng/mL。考察了碱金属元素对铜、锌和镉发射信号的影响,该方法应用于钢样中铜的测定,结果较好。  相似文献   

13.
A systematic study of the efficiency of protons, Ni, Pd and Th as chemical modifiers for the determination of cadmium by electrothermal atomic absorption spectrometry (ETAAS) using fast temperature programs was made for platform atomization. A comparison was made in terms of the salt type, absorbance-time profiles and elimination of the sodium chloride interference. The results were adapted to develop a method for the ETAAS determination of cadmium in biological and environmental samples. The highest sensitivity to determine cadmium in biological and environmental samples was obtained using nickel (together with protons) as a chemical modifier. The accuracy of the method was tested by the determination of cadmium in different certified reference materials. The best detection limit and the characteristic mass of Cd were found to be 0.03 ng mL(-1) and 0.35 pg, respectively.  相似文献   

14.
This work relates the development of an analytical methodology to simultaneously determine three methylxanthines (caffeine, theobromine, and theophylline) in beverages and urine samples based on reversed-phase high-performance liquid chromatography. Separation is made with a Bondesil C18 column using methanol-water-acetic acid or ethanol-water-acetic acid (20:75:5, v/v/v) as the mobile phase at 0.7 mL/min. Identification is made by absorbance detection at 273 nm. Under optimized conditions, the detection limit of the HPLC method is 0.1 pg/mL for all three methylxanthines. This method is applied to urine and to 25 different beverage samples, which included coffee, tea, chocolate, and coconut water. The concentration ranges determined in the beverages and urine are: < 0.1 pg/mL to 350 microg/mL and 3.21 microg/mL to 71.2 microg/mL for caffeine; < 0.1 pg/mL to 32 microg mL and < 0.1 pg/mL to 13.2 microg/mL for theobromine; < 0.1 pg/mL to 47 microg/mL and < 0.1 pg/mL to 66.3 microg/mL for theophylline. The method proposed in this study is rapid and suitable for the simultaneous quantitation of methylxanthines in beverages and human urine samples and requires no extraction step or derivatization.  相似文献   

15.
This work assesses the use of modified natural natrolite zeolite as an adsorptive material for the separation and preconcentration of trace amounts of ions. In this work we investigated the potential of modified natural natrolite zeolite for the simultaneous separation and preconcentration of trace amounts of copper and zinc ions. We have developed a simple, rapid, selective, sensitive and economical method for the simultaneous separation and preconcentration of trace amounts of copper and zinc in an aqueous medium using 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) as an analytical reagent. The sorption was quantitative in the pH range 7.5 - 9.5, whereas quantitative desorption occurred instantaneously with 5.0 mL of 2 mol L(-1) nitric acid. Linearity was maintained between 0.05 - 6.0 microg mL(-1) for copper and 0.02 - 1.5 microg mL(-1) for zinc in the final solution. Ten replicate determinations of 1.0 microg mL(-1) copper and 0.5 microg mL(-1) zinc in a mixture gave mean absorbances of 0.1687 and 0.2788 with relative standard deviations of +/-1.2% and +/-1.3%, respectively. The detection limits were 0.03 ng mL(-1) for Cu(II) and 0.006 ng mL(-1) for Zn(II) in the original solution (3 sigma(bl)/m). Different parameters, such as the effect of the pH, flow rate, breakthrough volume and interference of a large number of anions and cations, were studied and the proposed method was used for the determination of these metal ions in water as well as standard samples (e.g. Nippon Keikinzoku Kogyo (NKK) CRM, No. 916 and No. 920 aluminum alloy, National Institute for Environment Studies (NIES) No. 1 pepperbush and NIES No. 2 pond sediment). The determination of these metal ions in standard samples showed that the proposed method has good accuracy (recovery > 97%).  相似文献   

16.
S M Wu  Y H Ho  H L Wu  S H Chen  H S Ko 《Electrophoresis》2001,22(13):2717-2722
In this study, low concentrations of histamine2-receptor (H2-)antagonists were effected across a water plug, with separation taking place in a binary buffer comprising ethylene glycol and NaH2PO4 (pH 5.0), and detection at 214 nm. Liquid-liquid extraction with ethyl acetate- isopropanol is shown to provide extracts that are sufficiently clean. The calibration curves were linear over a concentration range of 0.1-2.00 microg/mL cimetidine, 0.2-5.0 microg/mL ranitidine-HCl, 0.3-5.0 microg/mL nizatidine, and 0.1-3.0 microg/mL famotidine. Mean recoveries were > 82%, while the intra- and interday relative standard deviations (RSDs) and relative errors (REs) were all < 13%. The method is sensitive with a detection limit of 3 ng/mL cimetidine, 30 ng/mL ranitidine HCl, 50 ng/mL nizatidine and 10 ng/mL famotidine (S/N = 3, electric-driven injection 90 s). This newly developed capillary electrophoresis (CE) method was applied for the determination of analytes extracted from plasma taken from a volunteer dosing a cimetidine, ranitidine, and nizatidine tablet simultaneously. These three H2-antagonists can be detected in real samples by this method, excluding the low dosing of famotidine tablet.  相似文献   

17.
Clenbuterol (CBL) is a potent beta(2)-adrenoceptor agonist used for the management of respiratory disorders in the horse. The detection and quantification of CBL can pose a problem due to its potency, the relatively low dose administered to the horse, its slow clearance and low plasma concentrations. Thus, a sensitive method for the quantification and confirmation of CBL in racehorses is required to study its distribution and elimination. A sensitive and fast method was developed for quantification and confirmation of the presence of CBL in equine plasma, urine and tissue samples. The method involved liquid-liquid extraction (LLE), separation by liquid chromatography (LC) on a short cyano column, and pseudo multiple reaction monitoring (pseudo-MRM) by electrospray ionization quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS). At very low concentrations (picograms of CBL/mL), LLE produced better extraction efficiency and calibration curves than solid-phase extraction (SPE). The operating parameters for electrospray QTOF and yield of the product ion in MRM were optimized to enhance sensitivity for the detection and quantification of CBL. The quantification range of the method was 0.013-10 ng of CBL/mL plasma, 0.05-20 ng/0.1 mL of urine, and 0.025-10 ng/g tissue. The detection limit of the method was 13 pg/mL of plasma, 50 pg/0.1 mL of urine, and 25 pg/g of tissue. The method was successfully applied to the analysis of CBL in plasma, urine and various tissue samples, and in pharmacokinetic (PK) studies of CBL in the horse. CBL was quantified for 96 h in plasma and 288 h in urine post-administration of CLB (1.6 micro g/kg, 2 x daily x 7 days). This method is useful for the detection and quantification of very low concentrations of CBL in urine, plasma and tissue samples.  相似文献   

18.
Electrothermal atomic absorption spectrometry was used to determine aluminium and chromium in different types of baby foods. Samples without previous treatment were introduced into the atomizer as suspensions, which were prepared in a medium containing 0.1% (w/v) Triton X-100 (for chromium) or 10% (v/v) ethanol (for aluminium), 5% (v/v) concentrated hydrogen peroxide, and 0.5% (v/v) concentrated nitric acid. The slurries were homogenized with a potter and introduced directly into the furnace. The presence of nitric acid allowed a substantial amount of analyte to be extracted to the liquid phase. No matrix effect was observed and aqueous standard solutions were used for calibration. The detection limits were 4 and 50 pg for chromium and aluminium, respectively; characteristic masses were 3.8 pg for chromium and 18 pg for aluminium. Reliability of the procedures was checked by statistically comparing the results with those obtained with a previous microwave oven mineralization stage and by analyis of several certified reference materials. Values for the aluminium content ranged between 0.4 and 3.0 microg/g, and for chromium between 0.003 and 0.06 microg/g.  相似文献   

19.
A gas chromatography/mass spectrometry (GC/MS) method was developed to study the pharmacokinetics of ligustilide following oral administration to rats. The method was used for the analysis of samples taken from rats. Biological samples were prepared by liquid-liquid extraction (LLE) using an n-hexane-ether (2:1) solvent mixture for a sample clean-up step and analyzed by GC/MS with a quadrupole MS detector in selected ion monitoring mode (m/z 190). The calibration curves were linear over the concentration range 0.172-8.60 microg/mL (r > 0.99) for blood samples and a different range (r > 0.99) for different tissue samples. The limit of detection (LOD) was 1.0 ng/mL or 1.0 ng/g (three times the signal-noise ratio). Within- and between-day precision expressed as the relative standard deviation (RSD) for the method was 1.58-3.88 and 2.99-4.91%, respectively. The recovery for all samples was >80%, except for liver samples (>70%). The main pharmacokinetic parameters obtained were: T(max) = 0.65 +/- 0.07 h, C(max) = 1.5 +/- 0.2 microg/mL, AUC = 34 +/- 6 h microg/mL and K(a) = 3.5 +/- 0.6/h. The experimental results showed that ligustilide was easily absorbed, but its elimination was slow, from 3 to 12 h after oral administration. The concentrations of ligustilide in rat cerebellum, cerebrum, spleen and kidney were higher than those in other organs.  相似文献   

20.
An ultrasonic slurry sampling graphite furnace AAS method was developed for the determination of Al, Cu, Li and Mn in spruce seeds, NBS SRM 1575 pine needles and GBW CRM 07602 bush branches and leaves. The only sample preparation was grinding in a Mixer Mill before preparing a slurry by adding 0.14 mol/L nitric acid to a small sample aliquot. Cryogenic grinding was used for the spruce seeds to solve the problem of agglomerating during grinding at room temperature. A modified sample tray was applied allowing the use of both the commercial 1.5 mL vials and home-made 15 mL vials. With optimal conditions for ultrasonic agitation the homogeneity and particle size distributions in the slurries prepared in the two different vials were similar. Several aspects of the slurry sampling approach are discussed and data of important parameters are given, including the total number of particles injected into the graphite furnace, densities of the materials and percentage of analyte extracted into the liquid phase of the slurry. The density of the materials was determined by two methods; by using a Coulter particle analyser and by using a gravimetric method. The two methods gave similar accuracy and precision. The concentration ranges of the elements (in microg g(-1)) were: 80-2100 for Al, 3-15 for Cu, 0.06-2.5 for Li and 50-700 for Mn. External calibration with aqueous standards was employed. Chemical modifiers were not found to be necessary. The relative standard deviations were in the range 1.7-7%. Analyses of the two certified plant reference materials confirmed the accuracy of the method. In addition no significant difference was found for analyses of digested and slurried spruce seeds. The detection limit was 10 ng g(-1) for Li and 170 ng g(-1) for Cu. The characteristic mass (area measurements) was 4.4 pg for Li and 11 pg for Cu. For Al and Mn less sensitive wavelengths were used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号