首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PURPOSE: Recent studies have proposed that magnetic resonance (MR) T1rho relaxation time is associated with loss of macromolecules. The depletion of macromolecules in the matrix of the intervertebral disc may be an initiating factor in degenerative disc disease. The purpose of this study was to test the feasibility of quantifying T1rho relaxation time in phantoms and intervertebral discs of healthy volunteers using in vivo MR imaging at 3 T. MATERIALS AND METHODS: A multislice T1rho spiral sequence was used to quantify T1rho relaxation time in phantoms with different agarose concentrations and in the intervertebral discs of 11 healthy volunteers (mean age=31.3 years; age range=23-60 years; gender: 5 females, 6 males). RESULTS: The phantom studies demonstrated the feasibility of using spiral imaging at 3 T. The in vivo results indicate that the median T1rho value of the nucleus (116.6+/-21.4 ms) is significantly greater (P<0.05) than that of the annulus (84.1+/-11.7 ms). The correlations between the age of the volunteers and T1rho relaxation time in the nucleus (r2=-0.82; P=0.0001) and the annulus (r2=-0.37; P=0.04) were significant. A trend of decreasing T1rho values from L3-4 to L4-5 to L5-S1 was evident. CONCLUSION: The results of this study suggest that in vivo T1rho quantification is feasible and may potentially be a clinical tool in identifying early degenerative changes in the intervertebral disc.  相似文献   

2.
The progression of OA in patients may be followed by measuring the volume of articular cartilage from MR images. We attempted to determine the reproducibility of volume measurements of articular cartilage made from magnetic resonance images of the knees and the dependence of the reproducibility on image resolution and contrast-to-noise. A fat-suppressed 3D technique was used to generate four image sets with different image resolution. Each patient was imaged twice to obtain image pairs at each resolution. To assess the dependence of reproducibility on noise we generated six image sets for each patient by adding noise to the original images and repeating the comparison. On each image set, the femoral, tibial, and patellar cartilage were outlined by a combination of computer and manual methods, and the images were used to calculate the volume of each cartilage plate. Comparing the coefficient of variance between the volume measurements made from the two visits, the volume measurements made from images with the highest resolution (0.275 x 0.275 x 1.0 mm) had the highest reproducibility. The high resolution images of the tibia and femur had the least partial-volume averaging and, as a result, better defined the boundaries between cartilage and adjacent tissues. A different trend was evident for the patella. For studies of osteoarthritis therapies, we recommend using MR images with the highest possible in-plane spatial resolution to provide the most reproducible volume measurements of knee cartilage.  相似文献   

3.
OBJECTIVE: The purpose of this study was to evaluate cartilage defect at medial femoral condyle on MRI in early osteoarthritis and to compare with early osteoarthritis with meniscal tear without clear cartilage defect. MATERIALS AND METHODS: Twelve patients with medial pain of the knee and cartilage defect without meniscal tear by MRI were studied for cartilage defect. There were two males and 10 females with cartilage defect, and they were between 42 and 61 years of age (average, 51.6). Fifteen patients with medial pain of the knee and meniscal tear and without clear cartilage defect had been studied as meniscal tear cases. There were five males and 10 females with meniscal tear, and they were between 45 and 61 years of age (average 54.5). In both groups, knee injuries by trauma and Kellgren radiographic grade III and IV osteoarthritis were excluded. We compared cartilage defect cases and meniscal tear cases by gender, age, medial meniscus displacement ratio from the edge of the tibial medial joint surface, femorotibial angle (FTA) and Mikulicz line. We measured medial meniscus displacement ratio by the proportion of medial meniscus lesion protruding from the edge of tibial medial joint surface to all the medial meniscus width on MRI. For the evaluation of Mikulicz line, we measured the score by the length from tibial medial joint surface to Mikulicz line to tibial plateau width. chi(2) Test was used for gender, and Mann-Whitney U test was used for age, medial meniscus displacement ratio, FTA and Mikulicz line. RESULTS: Statistically significant difference was not observed between cartilage defect cases and meniscal tear cases for age and gender. Medial meniscus displacement ratio was 13+/-12.3% in cartilage defect cases and 50.4+/-20.1% in meniscal tear cases. Medial meniscus displacement ratio in cartilage defect cases was significantly smaller than in meniscal tear cases (P=.0001). FTA was 174.9+/-2.2 degrees in cartilage defect cases and 178.3+/-4.8 degrees in meniscal tear cases. FTA in cartilage defect cases was significantly smaller than in meniscal tear cases (P=.00390). The score by the length from tibial medial joint surface to Mikulicz line to tibial plateau width was 35.8+/-11.8% in cartilage defect cases and 21.7+/-15.8% in meniscal tear cases. Mikulicz line in cartilage defect cases passes more laterally than in meniscal tear cases significantly (P=.0264). CONCLUSION: In this study, we reported cartilage defect cases at medial femoral condyle in the early osteoarthritis of the knee. We think that these cases were different from early osteoarthritis with meniscal tear in alignment of lower limb and onset mechanism. It is necessary to evaluate meniscus and cartilage in MRI when we diagnose middle-aged patients with medial pain of the knee and without remarkable changes of X-ray.  相似文献   

4.
PURPOSE: The purpose of this study was to evaluate the feasibility of using proton and sodium magnetic resonance imaging (MRI) to detect fluid accumulation produced by fludrocortisone and nifedipine - two drugs known to cause salt/water retention by different mechanisms. MATERIALS AND METHODS: Twelve young healthy male subjects were randomly assigned to one of two groups and treated with either fludrocortisone or nifedipine for 14 or 25 days, respectively. The change in sodium MRI, as well as in proton T(2) value and T(1)-weighted signal intensity in the calf following postural change [referred to here as 'postural delta signal'(PDS)], was evaluated before, during and after drug administration. The changes in MRI PDS were compared to conventional physiological parameters, including body weight, calf volume and pitting edema. RESULTS: When compared to the baseline pretreatment values, the subjects treated with fludrocortisone showed a 5.5% increase in sodium MRI PDS (P=.01), a 2-ms increase in proton T(2) PDS of the gastrocnemius muscle (P=.06) and a body weight gain of 2.3% (P=.001) within 1 week. In the nifedipine-treated subjects, the sodium MRI PDS increased by 6% versus baseline (P=.03), while the proton T(2) PDS of the gastrocnemius muscle increased by 3.7 ms (P=.01), associated with a 0.5% weight gain (P=.55), within 3 weeks. No significant changes were noted in the T(1)-weighed images following postural change. Measurements of calf circumference, volume and pitting edema did not show consistent changes associated with the drug administration. CONCLUSION: The postural change in sodium MRI and proton T(2) signals provides a sensitive method for detecting the fluid accumulation produced by fludrocortisone and nifedipine. The MRI results are consistent with treatment-induced increases in extracellular fluid volume and correlate well with the observed weight gain. These findings support the potential utility of MRI for the evaluation of medication-induced fluid retention.  相似文献   

5.

Objective

The objective of this study was to develop quantitative T-weighted magnetic resonance imaging methodology for the detection and characterization of cartilage degeneration in a rabbit anterior cruciate ligament (ACL) transection model.

Methods

The right knee ACLs of 18 adult female New Zealand white rabbits were transected. The left knee joint served as a sham control. The rabbits were euthanized at 3 (Group 1), 6 (Group 2) and 12 (Group 3) weeks postoperatively. High-resolution 3D fat-saturated spoiled gradient echo images and T-weighted images were obtained in both the sagittal and axial planes at 3 T using a quadrature wrist coil. Following MR analysis, histological slides from the lateral femoral condyle cartilage were graded using the Mankin grading system.

Results

For all three groups, the average overall T values were significantly higher in the ACL-transected knee compared to control knee, and the percentage differences in T values between ACL-transected and control increased with the duration of time after transection. The average Mankin score for ACL-transected knees was higher than that for control for each time point, but this difference was statistically significant only for all groups combined.

Conclusions

This study demonstrates the feasibility of using T-weighted imaging as a useful tool in the detection and quantification of cartilage damage in all knee compartments in an ACL-transected rabbit model of cartilage degeneration.  相似文献   

6.
In a single-voxel stimulated echo localization sequence in magnetic resonance spectroscopy, magnetic field gradients are inserted within the echo time (TE) to filter signals generated through coherence pathways other than that leading to the stimulated echo. There is a significant penalty for these gradients as they increase the minimum TE, thereby leading to significant signal loss from spin-spin relaxation and phase distortions in coupled spin systems. Here, an RF phase rotation technique is described for a stimulated echo localization sequence that allows removal of the gradients in the TE intervals and, subsequently, reduction of the minimum TE to only 6 ms. Experiments carried out on six healthy volunteers on a 1.5-T whole-body MR system show a significant signal increase in the metabolite concentrations when measured with a 6-ms TE (N-acetyl-aspartate, 12%, P=.002; creatine, 15%, P=.04; and glutamate+glutamine, 92%, P=.02) compared to concentrations measured with data collected at TEs of 15 and 20 ms.  相似文献   

7.
Magnetic resonance (MR) images and relaxation and diffusion maps of articular cartilage were obtained to explain discrepancies in its MR appearance. Porcine specimens were studied only by MR microscopy. For human specimens a combination of MR microscopy and large-scale MR imaging was used. Common features in the laminar structures of human and porcine samples are described. It was found that the decay of transverse magnetization was nonexponential with a rapidly decaying component which prevented construction of reliable proton-density maps. Dependence of T2 values on the orientation of specimens in the magnetic field as well as magnetization transfer experiments supported the previous suggestions about a significant role of dipolar interaction with protons of collagen in the laminar appearance of articular cartilage. The loss of the laminar structure induced by rotation of the human cartilage specimen around the axis normal to its surface demonstrated nonuniform angular distribution of the collagen fibers within the layer.  相似文献   

8.
Fast gradient systems enable the imaging of moving organs but also restrict imaging possibilities by stimulating the peripheral nerves. Several studies have determined the stimulation thresholds of the peripheral nerves. However, no study has explicitly examined whether stimulation thresholds are dependent on the position of the patient in the MR imager. In this study, combinations of one, two and three gradient axes were switched with sinusoidal wave forms (rise time 300 micros). Stimulation thresholds were determined for five patient positionings: gradient isocenter at the bridge of the nose, jugular fossa, 10 cm cranial of the umbilicus, umbilicus, and 10 cm caudal of the umbilicus. Experiments were performed in two volunteer groups, one for triple gradient switching (17 male, 14 female) and the other for single and double gradient switching (14 male, 11 female). The dependence of the stimulation threshold on the position of the volunteers in the MR imager was statistically significant for most of the gradient combinations, with the highest stimulation thresholds for positions umbilicus+10 and umbilicus at isocenter. Similar patterns of position dependence were obtained for gradient pairs whose axes were axially symmetric to the human body. Mean stimulation thresholds of male volunteers were lower than those of female volunteers. These findings indicate that stimulation thresholds should be defined according to the position of the patient in the MR scanner.  相似文献   

9.
Relaxation rates in the rotating frame (R1rho) and spin-spin relaxation rates (R2) were measured in articular cartilage at various orientations of cartilage layer to the static magnetic field (B0), at various spin locking field strengths and at two different static magnetic field strengths. It was found that R1rho in the deep radial zone depended on the orientation of specimens in the magnet and decreased with increasing the spin locking field strength. In contrast, R1rho values in the transitional zone were nearly independent of the specimen orientation and the spin locking field strength. Measurements of the same specimens at 2.95 and 7.05 T showed an increase of R1rho and most R2 values with increasing B0. The inverse B0 dependence of some R2 values was probably due to a multicomponent character of the transverse magnetization decay. The experiments revealed that the dominant T1rho and T2 relaxation mechanism at B0 < or = 3 T is a dipolar interaction due to slow anisotropic motion of water molecules in the collagen matrix. On average, the contribution of scalar relaxation due to rapid proton exchange in femoral head cartilage at 2.95 T is about 6% or less of the total R1rho at the spin locking field of 1000 Hz.  相似文献   

10.
We report the determination of intramyocellular lipids (IMCLs) of the soleus muscle of patients with type 2 diabetes mellitus (T2DM) using proton magnetic resonance spectroscopy. In addition, the various anthropometric and biochemical profiles of these patients were determined, including estimation of C-reactive protein (CRP), an inflammatory marker of coronary heart disease, and insulin resistance [Homeostasis Model Assessment (HOMA-IR)]. The estimated CRP level and the IMCL content in these patients were correlated with body mass index, percentage of body fat, other measures of abdominal obesity, serum lipoproteins, fasting and post-oral glucose load serum insulin levels and other surrogate markers of insulin resistance. The IMCL content (P=.04), CRP (P=.008) and insulin resistance (P=.0007) were significantly higher in T2DM patients compared to healthy controls. However, IMCL content did not correlate with values of fasting insulin, HOMA-IR or CRP in either group. These findings have strong implications of increased cardiovascular risk in Asian Indians with T2DM. The absence of relationship between CRP and IMCL needs to be explored further in a study using a large sample size.  相似文献   

11.
OBJECTIVE: This study aimed to prospectively compare measurement precision of calf intramyocellular lipid (IMCL) quantification at 3.0 and 1.5 T using (1)H magnetic resonance spectroscopy ((1)H-MRS). MATERIALS AND METHODS: We examined the soleus and tibialis anterior (TA) muscles of 15 male adults [21-48 years of age, body mass index (BMI)=21.9-38.0 kg/m(2)]. Each subject underwent 3.0- and 1.5-T single-voxel, short-echo-time, point-resolved (1)H-MRS both at baseline and at 31-day follow-up. The IMCL methylene peak (1.3 ppm) was scaled to unsuppressed water peak (4.7 ppm) using the LCModel routine. Full width at half maximum (FWHM) and signal-to-noise ratios (SNRs) of unsuppressed water peak were measured using jMRUI software. Measurement precision was tested by comparing interexamination coefficients of variation (CV) between different field strengths using Wilcoxon matched pairs signed rank test in all subjects. Overweight subjects (BMI>25 kg/m(2)) were analyzed separately to examine the benefits of 3.0-T acquisitions in subjects with increased adiposity. RESULTS: No significant difference between 3.0 and 1.5 T was noted in CVs for IMCL of soleus (P=.5). CVs of TA were significantly higher at 3.0 T (P=.02). SNR was significantly increased at 3.0 T for soleus (64%, P<.001) and TA (62%, P<.001) but was lower than the expected improvement of 100%. FWHM at 3.0 T was significantly increased for soleus (19%, P<.001) and TA (7%, P<.01). Separate analysis of overweight subjects showed no significant difference between 3.0- and 1.5-T CVs for IMCL of soleus (P=.8) and TA (P=.4). CONCLUSION: Using current technology, (1)H-MRS for IMCL at 3.0 T did not improve measurement precision, as compared with 1.5 T.  相似文献   

12.
The purpose of this study was to determine whether MR findings can correlate disease activity as measured by laboratory markers in ankylosing spondylitis. MR images in 19 patients with ankylosing spondylitis were retrospectively analyzed for cartilage abnormality, periarticular erosion, synovial enhancement, and bone marrow edema. Each MR finding was correlated with laboratory inflammatory markers (erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP)) and the sum of ESR + CRP. Synovial enhancement showed a significant correlation with ESR (r=0.58; p<0.01) and increased activity at bone scan (r=0.74; p<0.005), whereas there was no significant correlation with CRP. A significant correlation was found between ESR + CRP and synovial enhancement (r=0.54; p<0.05). Synovial enhancement was more common when ESR + CRP was greater than 30 (p<0.05). In conclusion, synovial enhancement at MR imaging could correlate disease activity as measured by laboratory inflammatory markers in ankylosing spondylitis.  相似文献   

13.
The scaling of the bond-bond correlation function P1(s) along linear polymer chains is investigated with respect to the curvilinear distance s along the flexible chain and the monomer density rho via Monte Carlo and molecular dynamics simulations. Surprisingly, the correlations in dense three-dimensional solutions are found to decay with a power law P1(s) approximately s(-omega) with omega=3/2 and the exponential behavior commonly assumed is clearly ruled out for long chains. In semidilute solutions, the density dependent scaling of P1(s) approximately g(-omega(0))(s/g)(-omega) with omega(0)=2-2nu=0.824 (nu=0.588 being Flory's exponent) is set by the number of monomers g(rho) in an excluded volume blob. Our computational findings compare well with simple scaling arguments and perturbation calculation. The power-law behavior is due to self-interactions of chains caused by the chain connectivity and the incompressibility of the melt.  相似文献   

14.
A total of 40 male and 40 female mice of equal body weight were used in the present study. Whole body gamma (60Co) irradiation was carried out at 400, 800 and 1200 rad. Life span and several parameters of body composition were measured. Cumulative mortality precentage was lower in irradiated females in comparison to males. Ionizing radiation induced reduction (P < 0.01) in body weight, total body water with its two compartments (extra-and intracellular), fat-free body with its component (body cell mass and extracellular tissue), fat-free dry solids with its constituent (body protein and body ash), body potassium and body fat. While all of the above mentioned body composition parameters decreased (P ≤ 0.01) following whole body irradiation, the rations between the body water to these parameters increased (P ≤ 0.01). Sex difference was noticed either for the parameters or for the ratios.  相似文献   

15.
INTRODUCTION: Image contrast between tissue types can be generated based on their T1/T2 ratio using spin-lock MRI techniques. An interesting application of such a concept would be to generate contrast in tissue with tissue relaxation times modified using exogenous contrast agents. An amplitude-modulated adiabatic waveform has been shown in the past to perform spin-lock MRI. However, implementation of this waveform may not prove to be efficient and practical in research or a clinical setup due to high radiofrequency power deposition. Recent advancement in software and hardware MR technology allows implementation of amplitude- and phase-modulated adiabatic waveforms on MR systems. The aim of this work was to explore role of adiabatic waveforms in performing rho imaging and demonstrate that amplitude- and phase-modulated waveforms [e.g., hyperbolic secant, B1 independent rotation-4 (BIR-4) waveforms] can be used to distinguish materials that differ in T1/T2 ratio. METHODS AND RESULTS: MR simulation was performed using computer routines implemented in MATLAB environment (Mathworks, Natick, MA). Modified Bloch equations with trapezoidal, hyperbolic secant and BIR-4 waveforms were used to perform MR simulation. Trapezoidal waveforms were only used for comparison to other waveforms. Gadolinium DTPA (Gad-DTPA) (T1/T2 approximately 1) and manganese chloride (MnCl(2)) (T1/T2 approximately 10) were used as examples of contrast agents due to their routine use in clinical and research setups and more importantly because they provide good examples of materials differing in T1/T2 ratios. Results of spin locking using trapezoidal waveform agree very well with the previously published results, thereby validating the computer routines used in this MR simulation. Plots of M(rho) (magnetization vector in rho domain) vs. offset frequency show distinct curves for these materials differing in T1/T2 for the three waveforms. BIR-4 waveform demonstrated a 40% difference in M(rho) ( approximately 150 Hz) for the materials. Rate of spin lock with hyperbolic secant waveform was rapid compared to other waveforms. DISCUSSION: MR simulation using contrast agents Gad-DTPA and MnCl(2) provided a useful way to demonstrate that amplitude- and phase-modulated adiabatic waveforms can be used to perform spin-lock imaging. Future work involves implementation of these waveforms on MR scanners and performing in vivo imaging to generate tissue contrast based on relaxation times ratio.  相似文献   

16.
The purpose of this study was to show the T(1rho) dispersion profile in various rat tissues (liver, brain, spleen, kidney, heart and skeletal muscle) at low (0.1 T) B(0) field at very low locking field B1, starting from 10 microT. The T(1rho) dispersion profile showed a quite similar pattern in all tissues. The highest R(1rho) relaxation rates were seen in the liver and muscle followed by the heart, whereas the values for spleen, kidney and brain were rather similar. The greatest difference between R2 relaxation rate and R(1rho) relaxation rate at B1=10 microT was seen in the liver and muscle. The steepest slope for a dispersion curve was seen in the muscle. The value of T(1rho) approximately approached the value of T2 when the locking field B1 approached 0. Except for the liver, the calculated apparent relaxation rate R2' was slightly larger than the calculated one. The potential value of T(1rho) imaging is to combine high R1 contrast of low-field imaging with the high signal-to-noise ratio (SNR) of high static field imaging. T(1rho) relaxation and dispersion data presented in the current study help to optimize the rotating-frame MR imaging.  相似文献   

17.

Purpose

To prospectively evaluate the feasibility of diffusion-weighted magnetic resonance imaging (DWI) for monitoring early treatment response to chemoradiotherapy (CRT) of nasopharyngeal carcinoma (NPC).

Materials and methods

Thirty-one patients with stage III and IV NPC were enrolled in this study from February 2012 to November 2012.T2-weighted and DWI sequences with diffusion factor of 0 and 800mm²/s were performed using a 3.0 T Philips Achieva TX scanner at baseline and 3 days, 20 days (after the first cycle of chemotherapy), 50 days (6 days after radiotherapy initiation) after neoadjuvant chemotherapy (NAC) initiation. The diameter of each primary lesion and target metastatic lymph node before and after the first cycle of NAC was measured and classified into stable disease (SD), partial response (PR) or completed response (CR) based on RECIST 1.1. The apparent diffusion coefficient (ADC) values and changes compared to baseline at each time point were compared between responders (CR and PR) and non-responders (SD). The rates of residual at the end of CRT were compared between these two groups.

Results

A significant increase in ADC was observed at each stage of therapy (P=.001) in lesions of primary and metastatic. The ADC values (ADC), ADC changes (ΔADC) and percentage ADC changes (Δ%ADC) of day 20 in responders were significantly higher than in non-responders for both primary lesions (p=.005, p=.006, p=.008, respectively) and metastatic lymph nodes (p=.002, p=.002, p=.003). Non-responders showed a higher rate of residual for both primary lesions (p=.008) and metastatic lymph nodes (p=.024) than responders.

Conclusions

DW MR imaging allows for detecting early treatment response of NPC. Patients with high ADC values and large ADC increase early after NAC initiation tended to respond better to CRT. Thus, accessing the curative effect of NAC in advanced NPC provides the opportunity to adjust following CRT regimen.  相似文献   

18.
The main purpose of this study was to determine and compare extra- and intramyocellular (IMCL) lipids content in the calf and thigh muscles of normal male and female volunteers using high-spatial-resolution magnetic resonance spectroscopic imaging (MRSI). The study groups consisted of 10 females and 10 males. The subjects were healthy and normal-weight. Fat (yellow bone marrow) was used as the internal concentration reference. Total fat and IMCL content were computed for all muscles in the slice and for three muscle compartments in the thigh, whereas three muscles and three muscle compartments were evaluated in the calf. To avoid the confounding effects of physical activity and diet, measurements were performed in the same session. A common feature for both genders was that thigh muscles had approximately 2.5 times greater total fat content as compared to muscles of the calf. The mean IMCL level was, however, more than 3 times higher in the calf muscles compared with the thigh. No significant differences in lipid concentrations of correspondent regions of interest were found between genders. The high-spatial-resolution MRSI technique enables a more detailed study of muscle lipid distribution and can therefore improve understanding of muscle lipid metabolism in healthy volunteers and in studies of patients with metabolic disorders.  相似文献   

19.
The E200K mutation on chromosome 20 can cause familial Creutzfeldt-Jakob disease (CJD). Patients with this mutation are clinically similar to those with sporadic CJD, but their imaging features are not well documented. We report here the quantitative and qualitative evaluation of the magnetic resonance (MR) imaging characteristics of this unique group of patients using three-dimensional spoiled gradient recalled (SPGR) echo images, diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) measurements, MR spectroscopy and a fluid-attenuated inversion recovery (FLAIR) sequence. The SPGR and ADC data were analyzed with SPM99. ANCOVA and regression models were used for a region-of-interest (ROI) analysis of ADC and metabolic ratios. CJD patients had a decreased fraction of gray matter and an increased fraction of cerebrospinal fluid (P=.001) in the cortex and cerebellum and increased ADC values in the cortex (P<.001). Focal decreases of ADC were found in the putamen via ROI analysis (548+/-83 vs. 709+/-9 microm(2)/s, P=.02). N-acetyl aspartate (NAA) was generally reduced, with the NAA/Cho ratio lowest in the cingulate gyrus. Qualitative assessment revealed hyperintensities on FLAIR, DWI or both in the putamen (three out of four patients), caudate (three out of four patients) and thalamus. These results provide a framework for future study of patients with genetically defined familial CJD.  相似文献   

20.
In vivo relaxation times and relative spin densities of gray matter (GM) and white matter (WM) of rat spinal cord were measured. Inductively coupled implanted RF coil was used to improve the signal-to-noise ratio required for making these measurements. The estimated relaxation times (in milliseconds) are: T1(GM) = 1021+/-93, T2(GM) = 64+/-3.4, T1(WM) = 1089+/-126, and T2(WM) = 79+/-6.9. The estimated relative spin densities are: rho(GM) = (60+/-2.3)% and rho(WM) = (40+/-2.1)%. The T1 values of GM and white matter are not statistically different. However, the differences in T2 values and spin densities of GM and WM are statistically significant. These in vivo measurements indicate that the observed contrast between GM and WM in spinal cord MR images mainly arises from the differences in the spin density.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号