相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
We present a pulse sequence that enables the accurate and spatially resolved measurements of the displacements of spins in a variety of (biological) systems. The pulse sequence combines pulsed field gradient (PFG) NMR with turbo spin-echo (TSE) imaging. It is shown here that by ensuring that the phase of the echoes within a normal spin-echo train is constant, displacement propagators can be generated on a pixel-by-pixel basis. These propagators accurately describe the distribution of displacements, while imaging time is decreased by using separate phase encoding for every echo in a TSE train. Measurements at 0.47 T on two phantoms and the stem of an intact tomato plant demonstrate the capability of the sequence to measure complete and accurate propagators, encoded with 16 PFG steps, for each pixel in a 128 x 128 image (resolution 117 x 117 x 3,000 microm) within 17 min. Dynamic displacement studies on a physiologically relevant time resolution for plants are now within reach.  相似文献   

2.
The technique of magnetic resonance imaging microscopy holds promise of bringing the full capabilities of NMR to arbitrarily specified positions within spatially inhomogeneous systems, including biological cells, yet the possibilities are limited by the need for adequate sensitivity and spatial resolution. We report proton magnetic resonance images obtained by combining advances in receiver coil sensitivity, gradient strength, and pulse/gradient sequence design. We achieve resolution of 3.7 +/- 0.4 microm by 3.3 +/- 0.3 microm by 3.3 +/- 0.3 microm for a volume resolution approximately 40 femtoliters (corresponding to approximately 3 x 10(12) proton spins).  相似文献   

3.
The magic asymmetric gradient stimulated echo (MAGSTE) sequence developed to compensate background-gradient cross-terms in the preparation and readout interval independently, assumes identical lengths for the two gradient pulses applied in each interval. However, this approach is rather inefficient if some extra delay time is present in one half of an interval, e.g. as required for special RF excitations or spatial encoding prior to the stimulated echo in MR imaging. Therefore, a generalized version of the sequence is presented that considers different gradient pulse lengths within an interval. It is shown theoretically that (i) for any pulse lengths a "magic" amplitude ratio exists which ensures the desired cross-term compensation in each interval and that (ii) prolonging one of the gradients can deliver a considerably higher diffusion weighting efficiency. These results are confirmed in MR imaging experiments on phantoms and in vivo in the human brain at 3T using an echo-planar trajectory. In the examples shown, typically 10 times higher b values can be achieved or an echo time reduction with a 40% signal gain in brain white matter. Thus, in case of asymmetric timing requirements, the generalized MAGSTE sequence with different gradient pulse lengths may help to overcome signal-to-noise limitations in diffusion weighted MR.  相似文献   

4.
Modifications of the pulse sequence for spectroscopic U-FLARE imaging are discussed to detect not only the predominant singlet signals of N-acetylaspartate, total creatine, and choline containing compounds or the doublet signal of lactate, but also the coupled resonances of glutamate, glutamine, taurine and myo-inositol. Effective homonuclear decoupling is achieved by use of constant time chemical shift encoding. A maximum signal-to-noise ratio (SNR) can be obtained for a certain coupled resonance of interest by optimizing the evolution period t(c) of the J modulated spin echo. Good reproducibility and a high SNR were achieved by combining several methods for water suppression and by using the displaced variant of U-FLARE. Measurements of a 3 mm slice of the rat brain were performed in vivo within 4 min, giving a nominal voxel size of 1.5 x 1.5 x 3.0 mm3 or 1.5 x 0.75 x 3.0 mm3. Thus, optimized spectroscopic U-FLARE is a powerful tool for proton spectroscopic imaging with high spectral, spatial and temporal resolution.  相似文献   

5.
Numerical simulations of NMR spectra can provide a rapid and convenient method for optimizing acquisition sequence parameters and generating prior spectral information required for parametric spectral analysis. For spatially resolved spectroscopy, spatially dependent variables affect the resultant spectral amplitudes and phases, which must therefore be taken into account in any spectral simulation model. In this study, methods for numerical simulation of spectra obtained using the PRESS localization pulse sequence are examined. A comparison is made between three different simulation models that include different levels of detail regarding the spatial distributions of the excitation functions, and spin evolution during application of the pulses. These methods were evaluated for measurement of spectra from J-coupled spin systems that are of interest for in vivo proton spectroscopy and results compared with experimental data. It is demonstrated that for optimized refocusing pulses it is sufficient to account for chemical shift effects only, although there is some advantage to implementing a more general numerical simulation approach that includes information on RF pulse excitation profiles, which provides sufficient accuracy while maintaining moderate computational requirements and flexibility to handle different spin systems.  相似文献   

6.
Dynamic nuclear polarization of metabolically active compounds labeled with (13)C has been introduced as a means for imaging metabolic processes in vivo. To differentiate between the injected compound and the various metabolic products, an imaging technique capable of separating the different chemical-shift species must be used. In this paper, the design and testing of a pulse sequence for rapid magnetic resonance spectroscopic imaging (MRSI) of hyperpolarized (13)C is presented. The pulse sequence consists of a small-tip excitation followed by a double spin echo using adiabatic refocusing pulses and a "flyback" echo-planar readout gradient. Key elements of the sequence are insensitivity to calibration of the transmit gain, the formation of a spin echo giving high-quality spectral information, and a small effective tip angle that preserves the magnetization for a sufficient duration. Experiments in vivo showed three-dimensional coverage with excellent spectral quality and SNR.  相似文献   

7.
γ-氨基丁酸(γ-aminobutyric acid,GABA)含量异常会引发一系列大脑疾病,因此在体检测人脑GABA含量成为一种十分必要的医疗技术.本文基于GABA检测常用的谱编辑方法MEGA-PRESS,引入性能更好的SLR脉冲代替常用的高斯脉冲,并使用单频带和双频带结合的方法激发特定频率的物质,在联影(United Imaging Healthcare,UIH)的uMR780磁共振系统上实现了一种优化的MEGA-PRESS序列.结果表明:SLR脉冲可以减少大分子(macromolecule,MM)信号对GABA信号的干扰;单频带和双频带结合可以更好地抑制残余水信号对GABA*信号的影响.水模实验和人体实验结果均证实优化的MEGA-PRESS序列可以更好地实现GABA*含量在体检测.  相似文献   

8.
Spectral editing using gradient selected double-quantum (DQ) coherence transfer is often used for the selective observation of metabolites in vivo. In attempting to optimize the detection sensitivity of a conventional DQ spectral editing sequence, the effects of using radiofrequency (RF) pulses that are not at the resonance frequency of the observed peaks were investigated both theoretically and experimentally. The results show that spectral editing using pulses at the frequency of the observed resonance does not necessarily give the optimal detection sensitivity. At 7 T, the detection sensitivity of lactate observed using a DQ editing method can be increased by up to 30% by setting the RF pulses off resonance at the proper frequency. The results also suggest that slice selective RF pulses used in DQ spectral editing combined with PRESS localization may have slice profiles different from those when the same pulses are used for standard PRESS spatial localization.  相似文献   

9.
实验验证了所建立的时间分辨光学层析成像测量系统的光学参量预测能力、多个测量通道的一致性,表明了本测量系统具有层析成像的潜力.研究了采用特征数据量(平均飞行时间、广义脉冲谱技术为基础的用数据类型R)及全时间分辨数据的图像重建算法在光学参量重建准确度、重建出的对象尺寸、空间分辨率等方面的各自优势.  相似文献   

10.
Rapid MR imaging techniques either deposit high amounts of radio frequency power or require powerful gradient systems with high slew rates, which might not be available on conventional scanners. QUEST provides a fast imaging method with scan times of the order of hundreds of milliseconds and avoids these problems at the cost of low signal-to-noise ratios (SNR). In this work, QUEST was optimized with regard to image quality and measuring time. With the use of a Hybrid QUEST technique, that refocuses the image echoes several times, a spatial resolution of 1.9 mm x 1.6 mm x 5 mm was achieved. By acquiring both the necessary correction data and the image information in a single echo train, the Hybrid QUEST technique was implemented as a true single-shot measurement with a total scan time of 190 ms. Optimization of the excitation flip angles and the amplitude and phase correction methods for image reconstruction resulted in an improved SNR of 53.7 in the white matter of the human head for a 10 mm slice thickness at 1.5 T. In contrast to echo planar imaging techniques, no image distortions were observed with Hybrid QUEST in anatomic regions with many tissue interfaces.  相似文献   

11.
Rapid surface-to-volume ratio and tortuosity measurement using Difftrain   总被引:2,自引:1,他引:1  
Analysis of diffusion measurements as a function of observation time (Delta), to calculate surface-to-volume ratios (S/V) and tortuosities (kappa), is a useful tool in the characterisation of porous media using NMR. However, using conventional pulsed field gradient (PFG) measurements, this requires long total experiment times (typically hours). Here, we show how the rapid diffusion measurement pulse sequence, Difftrain, can be used to provide the required experimental data much more rapidly (typically within minutes) with a consequential reduction in total experiment time of typically over an order of magnitude. Several novel modifications to the Difftrain pulse sequence are also presented to tailor it to this particular application; these include a variable delay between echoes (to ensure optimal echo position with respect to Delta) and a variable tip angle for the refocusing pulse (to ensure optimal use of available signal). Difftrain is applied to measure both S/V and kappa for a model glass bead pack; excellent agreement is found with both a conventional PFG measurement and with a bulk gravimetric measurement of S/V.  相似文献   

12.
13.
A gradient echo rapid velocity and acceleration imaging sequence (GERVAIS) has been developed and implemented to image liquid flow within a narrow packed bed. Two-dimensional velocity images have been acquired with an in-plane pixel size of 781 microm x 781 microm, with a data acquisition time of 20 ms for a single velocity component. Images of the x, y and z velocity vectors are reported. Data are reported for Reynolds numbers (based on particle diameter) of 200 and 300. In each case, GERVAIS images are compared with the results of a standard spin-echo phase-encoding velocity measurement. At Re = 200, steady-state flow is expected and the velocity images acquired using both techniques are consistent. At Re = 300, the GERVAIS sequence is able to image the unsteady-state flow field within this system. In contrast, the standard phase-encoding velocity measurement contains significant artefacts.  相似文献   

14.
A method is presented to use continuous wave electron paramagnetic resonance imaging for rapid measurement of oxygen partial pressure in three spatial dimensions. A particulate paramagnetic probe is employed to create a sparse distribution of spins in a volume of interest. Information encoding location and spectral linewidth is collected by varying the spatial orientation and strength of an applied magnetic gradient field. Data processing exploits the spatial sparseness of spins to detect voxels with nonzero spin and to estimate the spectral linewidth for those voxels. The parsimonious representation of spin locations and linewidths permits an order of magnitude reduction in data acquisition time, compared to four-dimensional tomographic reconstruction using traditional spectral-spatial imaging. The proposed oximetry method is experimentally demonstrated for a lithium octa-n-butoxy naphthalocyanine (LiNc–BuO) probe using an L-band EPR spectrometer.  相似文献   

15.
Spectrally resolved laser-induced fluorescence (LIF) with one-dimensional spatial imaging was investigated as a technique for detection of trace concentrations of nitric oxide (NO) in high-pressure flames. Experiments were performed in the burnt gases of premixed methane/argon/oxygen flames with seeded NO (15 to 50 ppm), pressures of 10 to 60 bar, and an equivalence ratio of 0.9. LIF signals were dispersed with a spectrometer and recorded on a 2-D intensified CCD array yielding both spectral resolution and 1-D spatial resolution. This method allows isolation of NO-LIF from interference signals due to alternative species (mainly hot O2 and CO2) while providing spatial resolution along the line of the excitation laser. A fast data analysis strategy was developed to enable pulse-by-pulse NO concentration measurements from these images. Statistical analyses as a function of laser energy of these single-shot data were used to determine the detection limits for NO concentration as well as the measurement precision. Extrapolating these results to pulse energies of ~?16 mJ/pulse yielded a predicted detection limit of ~?10 ppm for pressures up to 60 bar. Quantitative 1-D LIF measurements were performed in CH4/air flames to validate capability for detection of nascent NO in flames at 10–60 bar.  相似文献   

16.
The generalized magic asymmetric gradient stimulated echo (generalized MAGSTE) sequence compensates background gradient cross-terms and can be adjusted to asymmetric timing boundary conditions which for instance are present in echo-planar MR imaging. However, its efficiency is not optimal because one of the two diffusion-weighting gradients applied in each interval usually must have a reduced amplitude to ensure the desired cross-term compensation. In this work, a modification of generalized MAGSTE is investigated where this gradient pulse is replaced by two gradient pulses with full amplitude but opposite polarities. It is shown that with these bipolar gradients (i) the sequence retains the cross-term compensation capability for an appropriate choice of the gradient pulse durations and (ii) the diffusion-weighting efficiency is improved, i.e. higher k and b values can be achieved without prolonging the echo time. These results are confirmed in MR imaging experiments on phantoms and in vivo in the human brain at 3 T using spin-echo and echo-planar MR imaging. In the examples shown, the b value could be increased between about 30% and 200% when using the bipolar gradient pulses. Thus, bipolar gradients may help to improve the applicability of the generalized MAGSTE sequence.  相似文献   

17.
Methods developed for in vivo 1H-NMR spectroscopy are evaluated and applied using conscious rats. Good quality 1H-spectra of the brain are obtained using a surface coil and a spin echo pulse sequence with the binomial 1-1 and 2-2 water suppression pulses. However, comparing spectra from various rats with each other the water and lipid signals, which cause spectral overlap problems, may differ while the other spectral peaks agree well. Spatially one- and two-dimensional 1H spectroscopic imaging of the rat brain shows that the former signals stem from distinct spatial regions localized close to the rf coil. From a spectroscopic image, a spectrum over a limited spatial region is constructed in which the water signals are strongly reduced, the lipid signals are eliminated and lactic acid can be observed clearly simultaneously with other metabolites.  相似文献   

18.
A measure of the sharpness of vessel wall interfaces in carotid artery MRI may be useful for assessing the conspicuity of the wall's features. An edge detection technique was used to measure the signal intensity gradients in 2D time-of-flight (2D-TOF) and double-inversion recovery black-blood (DIR-BB) carotid artery images of normal subjects that were acquired at 1.5 T with 0.55 x 0.55 x 2.0-mm (0.6 mm3) acquisition voxels and zero filled to reduce the in-plane reconstructed voxel size by one half in each dimension as well as with 0.27 x 0.27 x 2.0-mm (0.15 mm3) acquisition voxels and at 3.0 T with 0.27 x 0.27 x 2.0-mm (0.15 mm3) acquisition voxels using surface coils. The gradient intensities of the lumen-to-background interface varied closely with the contrast-to-noise ratio of the 2D-TOF imaging. For the DIR-BB imaging, in which higher spatial frequency artery structures are visible, the gradient intensities at the interfaces were higher than theoretically predicted at both field strengths with smaller acquisition voxels. The use of acquisition voxels smaller than those previously used at 1.5 T can improve the visualization of carotid artery structures at 1.5 and 3.0 T with surface coil reception.  相似文献   

19.
应变梯度对布里渊光时域反射计测量精度的影响   总被引:4,自引:1,他引:3  
基于脉冲抽运的布里渊光时域反射计技术具有米数量级的空间分辩力。为了分析在其空间分辨力范围内的应变梯度增加对布里渊谱测量的影响,建立了后向布里渊散射谱与应变梯度的函数关系。数值分析结果表明应变梯度增大,不仅使布里渊频移随之线性增大,也会使后向布里渊散射谱峰值非线性降低,谱峰变得平坦。空间分辨力10m的100με/m应变梯度相对于零应变梯度,引起的布里渊频移测量误差增加2.04倍。传感光纤固定于悬臂梁上以模拟不同应变梯度,采用对频宽小于1MHz的激光脉冲调制和基于相干平衡检测的布里渊光时域反射计系统,实验测得了沿传感光纤的后向布里渊散射谱数据和应变分布。布里渊谱数据经最小二乘法拟合后,得到的不同应亦梯度的谱曲线变化与理论分析相吻合。  相似文献   

20.
A class of fast magnetic spectroscopic imaging methods using continuously oscillating gradients for four-dimensional (three spatial and one spectral) localization is introduced. Sampling may start immediately following the application of an RF excitation pulse, thus enabling measurement of spin density, chemical shift, and relaxation rates of short-T2species. For spatial localization, steady-state sinusoidal gradient waveforms are used to sample a ball inkspace. The two types of trajectories presented include: (1) continuously oscillating gradients with continuously rotating direction used for steady-state free-precession imaging and (2) continuously oscillating gradients followed by a spoiler directed along discrete projections. Design criteria are given and spatial–spectral and spatial–temporal reconstruction methods are developed. Theoretical point-spread functions and signal-to-noise ratios are derived while consideringT2*, off-resonance effects, and RF excitation options. Experimental phantom,in vivo,andin vitro1H and23Na images collected at 2.35 T are presented. The1H images were acquired with isotropic spatial resolution ranging from 0.03 to 0.27 cm3and gradient-oscillation frequencies ranging from 600 to 700 Hz, thus allowing for the separation of water and lipid signals within a voxel. The23Na images, acquired with 500 and 800 Hz gradient waveforms and 0.70 cm3isotropic resolution, were resolved in the time domain, yielding spatially localized FIDs.  相似文献   