首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We present a near-field optical technique for second-harmonic imaging by use of tapered optical fiber tips externally illuminated with femtosecond laser pulses. Enhancement of the electric field at the tip of the fiber results in enhanced second-harmonic (SH) generation from the sample region near the tip. This SH emission is collected by the same tapered fiber. The spatial distribution and polarization properties of SH generation from thin ferroelectric films and a poled single crystal of BaTiO(3) have been studied. A spatial resolution of the order of 80 nm was achieved. Symmetry properties of the near-field SH signal allow us to recover the local poling direction of individual ferroelectric domains in the film. Thus the technique provides a novel tool for nanometer-scale crystal analysis of polycrystalline samples.  相似文献   

2.
Ying J  Liu F  Ho PP  Alfano RR 《Optics letters》2000,25(16):1189-1191
A second-harmonic optical scanning imaging method for nondestructive evaluation of corrosion of painted metals is demonstrated. Two-dimensional images of the sectional structure from a sample of painted metal with corrosion were obtained by detection of second-harmonic generation (SHG). The second-harmonic signals generated from paint, corrosion, and metal can be spatially imaged in ~10-mum sliced subsurface layers. Corroded metal layers covered with paint are found to have more intensity variation than normal polished metal. The spatial mapping of the second-harmonic signals shows depth differentiation of paint, corrosion, and metal surfaces. The depth of corrosion beneath the paint can be measured from the SHG images.  相似文献   

3.
太赫兹时域光谱技术(THz-TDS)广泛应用于材料、生物医学、化学、药学、安检等诸多领域。传统扫描式THz-TDS技术需要通过改变探测光延时逐点扫描并重构时域信号,仅适合于具有较高重复频率且稳定的太赫兹辐射源情形下的样品探测。在低重复频率或涨落较大的太赫兹辐射源情形下和不可逆过程中样品的探测,扫描式THz-TDS不再适用,需要使用单发THz-TDS技术,单发THz-TDS技术原则上仅需要一个激光脉冲就可以获取一个完整的太赫兹时域脉冲波形。介绍几种主要的单发THz-TDS探测技术,这些技术都利用了电光晶体的泡克尔斯效应,通过测量探测光的某个物理量的变化来提取太赫兹信号。根据探测方法不同可分为光谱编码、空间编码和互相关等技术。在光谱编码技术中,探测光不同频率成分在时间上发生分离,不同时间成分分别被太赫兹脉冲不同时刻电场调制,通过测量探测光各个频率被太赫兹脉冲调制前后的光谱的变化提取太赫兹脉冲波形。该方法光路简单,测量结果直观,有较高的信噪比,但其时间分辨率较低,且被测太赫兹信号容易产生失真。为提高被测信号的时间分辨率,有人提出了空间编码技术,即不同位置探测光分别被太赫兹脉冲不同时刻电场调制,通过测量探测光各个位置太赫兹脉冲调制前后的光强变化提取太赫兹脉冲波形。根据不同空间展开方法可分为一维空间编码技术和二维空间编码技术。空间编码技术中虽然有较高的时间分辨率,但由于探测光在空间展开能量分散使得其信噪比相对较低。此外,还有一种较高时间分辨率的技术即互相关技术,可分为共线互相关和非共线互相关技术。在非共线互相关技术中,被太赫兹脉冲调制的激光啁啾脉冲与短脉冲互相关作用产生二次谐波,通过太赫兹脉冲调制前后二次谐波空间分布变化来提取太赫兹信号;在共线互相关技术中被太赫兹脉冲调制的啁啾脉冲与短脉冲共线入射到光谱仪,通过干涉条纹提取太赫兹信号,该技术提高了时间分辨率和信噪比,但光路布置复杂,不能进行实时监测。回顾了这几种单发THz-TDS探测技术的发展历程,综述探测技术的原理、实验方案和测量结果,并讨论了这些探测技术的优势和不足。  相似文献   

4.
Apertureless scanning near field optical microscopy techniques have become a common way of studying surface samples. By using a nano-probe that scatters the electromagnetic non-propagative waves emerging from a given sample, this microscopy provides optical images with a resolution beyond the diffraction limit. Despite a great diversity of works covering a wide variety of physical domains, the formation of the images obtained is not yet fully understood. The purpose of this letter is to assess the influence of the tip position and imposed oscillation of the tip in apertureless SNOM when a background field is added to the scattered near field. We propose a simple analytical model which enables us to account for the experimental results and explains how, depending on the experimental conditions, the near field signal can totally disappear or, on the contrary, be greatly enhanced.  相似文献   

5.
吴才章  叶梅  叶虎年 《光子学报》2005,34(10):1546-1549
为了研究扫描近场光学显微镜中探针和粗糙样品表面的耦合相互作用,提出了一种光耦合偶极子模型.在该模型中,探针和样品突起都由光极化偶极子表示,在准静态电磁场近似的情况下样品表面的诱导极化效应由影像偶极子表示,应用偶极子辐射理论可以得到系统的自洽场方程.此模型提供了一种直观分析扫描近场光学显微镜中探针和样品相互作用机理的方法.在此基础上,进一步讨论了金属样品的近场成像特点和其特有的局域光学共振现象.数值结果表明:不同于一般的介质样品,金属样品的近场图像与入射光频率直接相关,改变入射光的频率,获得的样品近场图像的形状和对比度都会发生变化.特别是当入射光频率处于样品极化共振范围内时,金属纳米粒子的极化率会出现光极化共振,这样就可以获得样品粒子的最大有效尺寸,为提高系统的分辨率提供了一条重要途径.  相似文献   

6.
剪切力模式近场扫描光学显微镜的恒幅反馈控制方法研究   总被引:1,自引:1,他引:0  
范晓明  王克逸 《光子学报》2008,37(8):1585-1588
剪切力模式近场扫描光学显微镜(Near-field Scanning Optical Microscopy,NSOM) 的音叉探针间距控制系统中,用相位反馈控制和检测剪切力,同时采用比例+积分(PI)技术实现对音叉探针振幅的反馈控制,使探针振幅在扫描过程中保持为恒定值.用相位信号作为探针与样品间距控制信号,分别在无振幅反馈和有振幅反馈两种情况下,以不同速率扫描得到标准CD_RW光盘光栅的两组图像,并进行了比较分析.实验表明,恒振幅反馈电路的引入有助于提高探针系统的响应速度和灵敏度,改善所得图像的质量及分辨率.  相似文献   

7.
We have used a home-made apertureless near-field scanning optical microscope (ANSOM) for mapping nanometric steps between SiC and gold regions under visible (λ=655 nm) and infrared (λ=10.6 μm) illumination. The images, obtained with a signal demodulation at the tip oscillation frequency and at higher harmonics, clearly show optical contrasts with a subwavelength resolution of about 30 nm. Other images recorded in the visible on a YBa2Cu3O7 crystal indicate that the tip used in our experiments is able to reveal polarization effects. We also present a near-field thermal optical microscope (NTOM) which operates without any external illumination. In this new kind of microscope, the laser source which is usually used to excite the evanescent waves, is replaced by a simple heating of the sample. The electromagnetic radiation locally scattered by the tip comes from the thermal radiation. Our results with this new technique prove a 200 nm lateral resolution.  相似文献   

8.
FABRICATION AND APPLICATION OF NEAR-FIELD OPTICAL FIBRE PROBE   总被引:1,自引:0,他引:1       下载免费PDF全文
In this paper, the fabrication of a large cone angle near-field optical fibre probe, using the two-step chemical etching method and bent probe, is introduced, and the controlling parameters of the coated Cr-Al film at the probe tip are presented. The scanning electron microscopy images display that the tip diameter of the uncoated large cone angle fibre probe obtained is less than 50nm, the cone angle over 90°, and the diameter of light aperture at the coated probe tip is less than 100nm. The measured results of the optical transmission efficiency for various probe tips show that the uncoated straight optical fibre probe, film-coated straight probe and film-coated bent probe are 3×10-1, 2×10-3, and 1×10-4 times that of the flat fibre probe, respectively. In addition, the force images and near-field optical images of a standard sample are acquired using a large cone angle and film-coated bent probe.  相似文献   

9.
外调制光纤CATV中SBS与MPI的激光器高频微扰抑制理论分析   总被引:1,自引:0,他引:1  
受激布里渊散射(SBS)与多径干涉噪音(MPI)是光纤AM-CATV外调制传输系统中主要的非线性现象,本文分析了激光器高频扰动抑制SBS与MPI的原理,导出了扰动对系统SBS阈值提高量及MPI抑制程度的理论公式,通过对扰动引起的激光器频率啁啾及附加强度调制而导致的色散的理论分析与计算,得到了扰动信号频率及幅度的选取原则。  相似文献   

10.
Caizhang Wu  Mei Ye  Hunian Ye 《Optik》2005,116(6):277-280
A coupled-dipole approach is proposed in order to study the coupling between the probe tip and the rough sample in SNOM. In the present model both the optical probe tip and the sample protrusions are represented by polarizable dipole spheres. The induced polarization effects on the sample surface can be replaced by the image dipoles in the circumstance of quasi-static electromagnetic field approximation. Applying the radiation theory of the dipole, we have established a set of self-consistent equations to describe the field distribution at the sites of the probe tip and the sample protrusions. The results are completely the same as those obtained by means of the dyadic electromagnetic propagator formalism and also the derivation procedure is relatively simple. This method permits us to analyze the physical mechanisms of the interaction between the probe tip and the rough surface in SNOM intuitively. Based on this approach, we further discuss the influence of polarization of the incident light on the imaging quality. The calculating result shows that the shape and the contrast of the images of the sample are both sensitive to the field polarization, and the z-polarized mode is proved to give better resolution in SNOM.  相似文献   

11.
Quantification of intracellular nanoscale macromolecular density distribution is a fundamental aspect to understanding cellular processes. We report a near-field penetrating optical microscopy (NPOM) technique to directly probe the internal nanoscale macromolecular density of biological cells through quantification of intracellular refractive index (RI). NPOM inserts a tapered optical fiber probe to successive depths into an illuminated sample. A 50 nm diameter probe tip collects signal that exhibits a linear relationship with the sample RI at a spatial resolution of approximately 50 nm for biologically relevant measurements, one order of magnitude finer than the Abbe diffraction limit. Live and fixed cell data illustrate the mechanical ability of a 50 nm probe to penetrate biological samples.  相似文献   

12.
We report the self- and external-dressed Autler-Townes (A-T) splittings of the images of the generated four-wave mixing signal (FWM) and electromagnetically induced transparency (EIT) of probe images in cascade three-level atomic system. Such spatial properties of probe and FWM signals are induced by the enhanced cross-Kerr nonlinearity. We demonstrate the controlled electromagnetically induced spatial dispersion (EISD), splitting and focusing of probe and FWM signals images by adjusting self- and external-dressing fields. Studies on such controllable A-T spatial splitting and spatial EIT effect can be very useful in applications of spatial signal processing and optical communication.  相似文献   

13.
Experimental results are presented which analyze the phase conjugation properties of four-wave mixing signals generated due to the beating between probe pulses broadened by a length of fibre and narrow pump pulses. This results in four-wave mixing pulses significantly narrower than the injected probe pulses albeit with reduced phase conjugation properties, which are examined. The pulses are completely characterized using the second-harmonic generation frequency resolved optical gating technique. The probe pulse is initially broadened due to propagation through 40 m of dispersion compensating fibre. This causes the probe pulse to be much wider than the injected pump pulse, in contrast to previously reported results. The four-wave mixing signal is therefore both wavelength converted and compressed, due to the gating properties of four-wave mixing, with respect to the initial probe signal. The phase conjugation properties of the converted signal are discussed and this signal is then passed through a second length of dispersion compensating fibre in order to further compress the pulse and to examine in more detail the phase conjugation properties.  相似文献   

14.
Local probing of second-order susceptibilities with a near-field optical microscope is demonstrated for the first time. Using an uncoated fiber tip as a light source, near-field images of a surface of y-cut LiNbO3 crystal and of a multilayer Langmuir–Blodgett film of 2-docosylamino-5-nitropyridine are obtained at the fundamental pump and second harmonic wavelengths while simultaneously recording surface topography. It is shown that optical second-harmonic images for different polarizations of the pump light reflect the difference in magnitude of the corresponding components of the second-order susceptibility tensor. Various degrees of correlation in contrast of optical (fundamental and second harmonic) and topographical images are observed and discussed.  相似文献   

15.
钱梦騄  赵亚军  程茜 《声学学报》2010,35(3):289-297
根据扫描探针声显微镜(SPAM)轻敲工作模式中探针作周期振动的特点,以及在探针与试样相接触过程中激振力和悬臂探针自由振动的阻尼力很小的假设下,解析求解了探针与试样的碰撞运动方程,得到了最大压痕深度和碰撞时间与探针半径、等效杨氏模量以及界面吸附能等之间的关系式,较直观地说明了SPAM中轻敲模式的相位像反差机理:信号的相位与试样微区的性质、探针振幅、设置点以及试样形貌等有关。并定量预计了纳米金刚石像中的相位差值72.59°,与实验测量平均值73.2°±8.2°一致。同时,合理地解释了实验得到的光学薄膜试样相位像的反差。这些表明SPAM轻敲模式的相位成像是一种纳米分辨率测量材料表面物理性质的成像技术。   相似文献   

16.
This paper describes a size-dependent electroless plating method to fabricate a new type of probe with a locally decreasing thickness of metal and a tiny tip size for a combined high resolution shear-force and near-field optical microscope. In this method, the tip size and decreasing thickness profile, which affect the resolution capabilities of the microscopes, are controlled by adding a continuous ultrasonic wave with a frequency of 1 MHz to a nickel plating bath. The probe with a tip radius of curvature of 25 nm was successfully fabricated at an ultrasonic power density of 1.6 W cm−2, its metal thickness gradually decreased from 850 to 20 nm toward the distal tip.  相似文献   

17.
Optical second-harmonic generation upon nanosecond laser irradiation of nanofibers grown from nonsymmetrically functionalized para-quarter-phenylene molecules on mica surfaces is investigated in the spectral region around electronic resonances. Strong multiphoton excited luminescence appears together with the second-harmonic signal in the spectra. It is demonstrated how the two components can be separated by analyzing emission spectra recorded over a broad range of wavelengths around the second-harmonic energy. Spectra of the absolute values of the second-harmonic signals are obtained for three differently functionalized molecules. Together with supplementary measurements of the structure of the nanofiber films this forms the basis for estimation of the second-harmonic susceptibility of the fiber materials. Values of the nonlinear susceptibilities are obtained, which are comparable to those of well-known inorganic nonlinear optical crystals.  相似文献   

18.
The resolution of the cell fluorescence image captured by a digital laser scanning microscopy with a modified dual-lens BD-ROM optical pickup head is enhanced by image registration and double sample frequency. A dual objective lens of red (655 nm) and blue (405 or 488 nm) laser sources with numerical apertures of 0.6 and 0.85 is used for sample focusing and position tracking and cell fluorescence image capturing, respectively. The image registration and capturing frequency are based on the address-coded patterns of a sample slide. The address-coded patterns are designed as a string of binary code, which comprises a plurality of base-straight lands and grooves and data-straight grooves. The widths of the base-straight lands, base-straight grooves, and data-straight grooves are 0.38, 0.38, and 0.76 μm, respectively. The numbers of sample signals in the x-direction are measured at every intersection point by intersecting the base intensity of the push–pull signal of the address-coded patterns, which has a minimum spacing of 0.38 μm. After taking a double sample frequency, the resolution of the measured cell fluorescence image is enhanced from 0.38 μm to the diffraction limit of the objective lens.  相似文献   

19.
Numerical simulations have been carried out in the framework of waveguide theory to model collection mode scanning near-field optical microscopy (SNOM). The theoretical model includes the optical fiber end and describes the metal coated aperture on the probe tip. The developed formalism goes beyond the existing Bethe-Bouwkamp theories for electromagnetic transmission of subwavelength apertures. The finite coating and optical fiber end are now taken into account. The new features enable us to simulate the near-field probes that are widely used in the collection mode SNOM. The emphases of the numerical analyses have been mainly on the resolution mechanism of the microscopy. Influence on the resolution from important parameters of the probe tips, such as the size of the apertures and the probe-sample distance, is extensively studied. The resolution dependence has been analyzed in the light of the near-field coupling efficiency of the probe tip. An optimum tip size has been found which is balanced between the significant signal transmission and the resolution of the device.  相似文献   

20.
扫描近场光学显微镜(ScanningNear-fieldOpticalMicroscope:SNOM)自80年代中期以来获得了迅速的发展并得到了具有纳米(亚纳米)尺度分辨率的光学图像。作为SNOM的关键技术之一,样品与探针间距的控制尤为重要,而实现起来比较困难。人们提出了多种方法,其中基于剪切力原理的控制方法最常用而且实验证明是可靠的。本文综述了扫描近场光学显微镜发展以来所出现的基于剪切力原理进行样品/探针间距的探测的一些主要的非光学方法。包括利用PMT直接探测样品辐射,利用音叉、电容、阻抗以及压电效应的探没方法等,并对各种方法的优缺点进行了分析比较。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号