首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
Concentrations of polybrominated diphenyl ethers (PBDEs) in Baltic Sea herring Clupea harengus membras L. collected from Estonian coastal waters are reported. In the period 2006–2008 the total PBDE concentrations (ΣPBDE, sum of 15 congeners) in Baltic herring varied between 0.57 and 4.08 ng g−1 fresh weight. Highest ΣPBDE concentrations were in a 2007 sample from the mouth of the Gulf of Finland and in a 2007 sample from the Gulf of Riga. The former contained a high concentration of BDE 209 (16.3 ng g−1) and in the latter this congener was the second most abundant. It is not clear whether the BDE 209 concentration in the Gulf of Finland sample is not an artefact and this value was not included in the above range. The PBDE concentrations increased with the age of herring are similar to those reported in [1] in fish collected in the Bothnian Sea in 2002 and did not increase between 2002 and 2008. The majority of concentrations in herring from the Estonian coastal zone was <1.0 ng g−1 fresh weight. The PBDE congener profiles varied regionally as well as with age of the fish. The main congeners were mostly the BDEs 47, 99, and 100. Some of the variations probably caused by measurement artefacts.  相似文献   

2.
Gas chromatographic analysis of polybrominated diphenyl ethers (PBDEs) has been evaluated in an attempt to achieve better control of the separation process, especially for highly substituted congeners. Use of a narrow-bore capillary column enabled adequate determination of tetra, penta, hexa, hepta, octa, nona and decaBDE congeners in only one chromatographic run while maintaining resolution power similar to that of conventional columns. A micro electron-capture detector (GC–μECD) was used. Chromatographic conditions were optimized by multifactorial experimental design, with the objective of obtaining not only high sensitivity but also good precision. In this way two different approaches to maximizing response and minimizing variability were tested, and are fully discussed. These optimum chromatographic conditions were then used to determine PBDEs extracted from domestic dust samples by microwave-assisted solvent extraction (MASE). Quantitative recovery (90–108%) was achieved for all the PBDEs and method precision (RSD < 13%) was satisfactory. Accuracy was tested by use of the standard reference material SRM 2585, and sub-ng g−1 limits of detection were obtained for all compounds except BDE-209 (1.44 ng g−1). Finally, several samples of house dust were analysed by use of the proposed method and all the target PBDEs were detected in all the samples. BDE-209 was the predominant congener. Amounts varied from 58 to 1615 ng g−1 and the average contribution to the total PBDE burden of 52%. The main congeners of the octaBDE mixture (BDE-183, BDE-197, BDE-207 and BDE-196) also made an important contribution (29%) to the total. These are the first data about the presence of these compounds in European house-dust samples. Finally, the sum of the main congeners in the pentaBDE commercial mixture (BDE-47, BDE-99, and BDE-100) contributed 14% to the total. Figure Polybrominated diphenyl ethers in House Dust  相似文献   

3.
A headspace solid-phase microextraction gas chromatography coupled with tandem mass spectrometry (HSSPME-GC-MS-MS) methodology for determination of brominated flame retardants in sediment and soil samples is presented. To the best of our knowledge, this is the first time that SPME has been applied to analyze polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) in environmental solid samples. Analyses were performed using 0.5-g solid samples moisturized with 2 mL water, employing a polydimethylsiloxane (PDMS) fiber coating, exposed to the headspace at 100 °C for 60 min. Several types of environmental solid samples were included in this study and the extraction efficiency was related to the organic matter content of the sample. Calibration was performed using real samples, and the method showed good linearity over a wide concentration range, precision, and afforded quantitative recoveries. The obtained detection limits were in the sub-ng g−1 for all the target analytes in both samples. The proposed procedure was applied to several marine and river sediments and soils, some of which were found to contain PBDEs at concentrations in the ng g−1 level; BDE-47, BDE-100, and BDE-99 were the major congeners detected. The proposed method constitutes a rapid and low-cost alternative for the analysis of the target brominated flame retardants in environmental solid samples, since the clean-up steps, fractionation, and preconcentration of extracts inherent to the classical multi-step solvent extraction procedures are avoided.   相似文献   

4.
Stir-bar-sorptive extraction (SBSE) with liquid desorption (LD) and ultra-high-performance liquid chromatography–electrospray ionization triple-quadrupole tandem mass spectrometry (UHPLC–(ESI)MS–MS) were used for analysis of six personal care products in environmental water: four UV filters (2,2-dihydroxy-4-methoxybenzophenone, benzophenone-3, octocrylene, and octyldimethyl-p-aminobenzoic acid) and two antimicrobial agents (triclocarban and triclosan). Experimental conditions that affect SBSE-LD sorption efficiency (extraction time and temperature, sample pH, and ionic strength) and desorption efficiency (solvent, temperature, and time) were optimized. The method proved to be sensitive—a 50-mL sample was used to determine these compounds in environmental waters at trace levels. The detection limits of the analytical method were 2.5 ng L−1 for river water and 5–10 ng L−1 for effluent and influent sewage water. In river waters, benzophenone-3 was found at levels from 6 ng L−1 to 28 ng L−1 and triclosan at levels <LOQ. Benzophenone-3 was found between 75 and 127 ng L−1 in influent sewage, whereas concentrations of benzophenone-3 and triclosan were commonly below 25 ng L−1 in effluent sewage.  相似文献   

5.
A gas chromatography electron capture negative ionization mass spectrometry (GC(ECNI)MS) procedure for the determination of priority polybrominated diphenyl ethers (PBDEs; congeners 28, 47, 99, 100, 153 and 154) in water samples at regulatory EU levels has been developed. The method is based on the use of 81Br-labelled PBDEs for isotope dilution analysis and the measurement of 79Br/81Br isotope ratios in gas chromatography peaks with the electron capture negative ionization technique. The suitability of this ion source for the precise and accurate measurement of bromine isotope ratios has been demonstrated. The general ECNI-IDMS procedure was evaluated by the analysis of NIST SRM 1947 (Lake Michigan fish tissue) with satisfactory results. For the analysis of water samples, 500 mL of the samples were spiked with the labelled PBDEs and extracted with 10 mL isooctane for 30 min. The extract was evaporated down to ca. 100 μL and injected in the GC(ECNI)MS. Detection limits ranged from 0.014 −1 to 0.089 pg mL−1 depending on the congener. Recoveries from real water samples, spiked at a level of 0.5 pg mL−1, ranged from 77% to 102%.  相似文献   

6.
A novel and efficient analytical methodology is proposed for extracting and preconcentrating polybrominated diphenyl ethers (PBDEs) from samples of environmental interest prior gas chromatography–mass spectrometry (GC–MS) analysis. It is based on the induction of micellar organized medium by using a non-ionic surfactant (Triton X-114) to extract the target PBDEs. To enable coupling the efficient extracting technique with GC analysis, ultrasound-assisted back-extraction (UABE) into an organic solvent was required. Several factors, including surfactant type and concentration, equilibration temperature and time, ionic strength, pH and buffers nature and concentration were studied and optimized over the extraction efficiency of the proposed technique. Under optimal experimental conditions, the target analytes were quantitatively extracted achieving an enrichment factor of 250 when 10 mL aliquot of ultrapure water spiked with PBDE-standard mixture (10 pg mL−1 each PBDE) was extracted. Method detection limits (MDLs) calculated with aqueous PBDEs solutions as three times the signal-to-noise ratio (S/N), ranged from 1 to 2 pg mL−1 with RSDs values ≤8.5% (n = 5). The coefficients of estimation of the calibration curves obtained following the proposed methodology were ≥0.9987 and linear range of all PBDEs was 4–150 pg mL−1. The proposed methodology was validated by carrying out a recovery study by spiking the samples at two different concentration levels of PBDEs (10 and 50 pg mL−1 for waters samples). Recoveries values in the range of 96–106% for water samples were obtained showing satisfactory robustness of the method for analyzing PBDEs in water samples. The proposed methodology was applied for the analysis of PBDEs: 2,2′,4,4′-tetraBDE (BDE-47), 2,2′,4,4,5-pentaBDE (BDE-99), 2,2′,4,4,6-pentaBDE (BDE-100) and 2,2,4,4′,5,5′-hexaBDE (BDE-153) in water samples, including drinking, lake, river water and soil samples. Significant quantities of PBDEs were not found in the analyzed samples.  相似文献   

7.
A simple, efficient, innovative and environmentally friendly analytical technique was successfully applied for the first time for the extraction and preconcentration of polybrominated diphenyl ethers (PBDEs) from water samples. The PBDEs selected for this work were those most commonly found in the literature in natural water samples: 2,2′,4,4′-tetraBDE (BDE-47), 2,2′,4,4,5-pentaBDE (BDE-99), 2,2′,4,4,6-pentaBDE (BDE-100) and 2,2,4,4′,5,5′-hexaBDE (BDE-153). The extracted PBDEs were separated and determined by gas chromatography–mass spectrometry (GC–MS). The extraction/preconcentration technique is based on ultrasound-assisted emulsification-microextraction (USAEME) of a water-immiscible solvent in an aqueous medium. Several variables including, solvent type, extraction time, extraction temperature and matrix modifiers were studied and optimized over the relative response the target analytes. Chloroform was used as extraction solvent in the USAEME technique. Under optimum conditions, the target analytes were quantitatively extracted achieving enrichment factors (EF) higher than 319. The detection limits (LODs) of the analytes for the preconcentration of 10 mL sample volume were within the range 1–2 pg mL−1. The relative standard deviations (RSD) for five replicates at 10 pg mL−1 concentration level were <10.3%. The calibration graphs were linear within the concentration range of 5–5000 pg mL−1 for BDE-47 and BDE-100; and 5–10,000 pg mL−1 for BDE-99 and BDE-153, respectively. The coefficients of estimation were ≥0.9985. Validation of the methodology was performed by standard addition method at two concentration levels (10 and 50 pg mL−1). Recovery values were ≥96%, which showed a successful robustness of the analytical methodology for determination of picogram per milliliter of PBDEs in water samples. Significant quantities of PBDEs were not found in the analyzed samples.  相似文献   

8.
溴系阻燃剂在环境及人体中的存在和代谢转化   总被引:9,自引:0,他引:9  
溴系阻燃剂的广泛使用及其对环境和人体的危害,受到人们的广泛关注。本文简要介绍了在环境与生态系统及人体中存在的三种主要溴系阻燃剂:多溴联苯醚、六溴环十二烷和四溴双酚A,重点评述了它们在环境介质(污水、淤泥及沉积物)、生物体(微生物及动物)、人体中及光热作用下的代谢与转化,并详细介绍了其代谢途径及代谢产物。  相似文献   

9.
A new adsorbent is proposed for the solid-phase extraction of phenol and 1-naphthol from polluted water. The adsorbent (TX-SiO2) is an organosilica composite made from a bifunctional immobilized layer comprising a major fraction (91%) of hydrophilic diol groups and minor fraction (9%) of the amphiphilic long-chain nonionic surfactant Triton X-100 (polyoxyethylated isooctylphenol) (TX). Under static conditions phenol was quantitatively extracted onto TX-SiO2 in the form of a 4-nitrophenylazophenolate ion associate with cetyltrimethylammonium bromide. The capacity of TX-SiO2 for phenol is 2.4 mg g−1 with distribution coefficients up to 3.4 × 104 mL g−1; corresponding data for 1-naphthol are 1.5 mg g−1 and 3 × 103 mL g−1. The distribution coefficient does not change significantly for solution volumes of 0.025–0.5 L and adsorbent mass less than 0.03 g; 1–90 μg analyte can be easily eluted by 1–3 mL acetonitrile with an overall recovery of 98.2% and 78.3% for phenol and 1-naphthol, respectively. Linear correlation between acetonitrile solution absorbance (A 540) and phenol concentration (C) in water was found according to the equation A 540 = (6 ± 1) × 10−2 + (0.9 ± 0.1)C (μmol L−1) with a detection range from 1 × 10−8 mol L−1 (0.9 μL g−1) to 2 × 10−7 mol L−1 (19 μL g−1), a limit of quantification of 1 μL g−1 (preconcentration factor 125), correlation coefficient of 0.936, and relative standard deviation of 2.5%. A solid-phase colorimetric method was developed for quantitative determination of 1-naphthol on adsorbent phase using scanner technology and RGB numerical analysis. The detection limit of 1-naphthol with this method is 6 μL g−1 while the quantification limit is 20 μL g−1. A test system was developed for naked eye monitoring of 1-naphthol impurities in water. The proposed test kit allows one to observe changes in the adsorbent color when 1-naphthol concentration in water is 0.08–3.2 mL g−1.  相似文献   

10.
Steroid hormone concentrations are mostly determined by using different body fluids as matrices and applying immunoassay techniques. However, usability of these approaches may be restricted for several reasons, including ethical barriers to invasive sampling. Therefore, we developed an ultra-performance LC–MS–MS method for high-throughput determination of concentrations of cortisol, cortisone, dehydroepiandrosterone (DHEA), and DHEA sulfate (DHEAS) in small quantities of human nails. The method was validated for linearity, limits of detection and quantification, recovery, intra and interassay precision, accuracy, and matrix effect. Samples from 10 adult women were analyzed to provide proof-of-principle for the method’s applicability. Calibration curves were linear (r 2 > 0.999) in the ranges 10–5000 pg mg−1 for cortisol, cortisone, and DHEAS, and 50–5000 pg mg−1 for DHEA. Limits of quantification were 10 pg mg−1 for cortisol, cortisone, and DHEAS, and 50 pg mg−1 for DHEA. The sensitivity and specificity of the method were good, and there was no interference with the analytes. Mean recovery of cortisol, cortisone, DHEA, and DHEAS was 90.5%, 94.1%, 84.9%, and 95.9%, respectively, with good precision (coefficient of variation <14% for all analytes) and accuracy (relative error (%) −8.3% to 12.2% for all analytes). The median (pg mg−1, range) hormone concentrations were 69.5 (36–158), 65 (32–133), 212 (50–1077), and 246 (115–547) for cortisol, cortisone, DHEA, and DHEAS, respectively. This method enables measurement of cortisol, cortisone, DHEA, and DHEAS in small quantities of human nails, leading to the development of applications in endocrinology and beyond.  相似文献   

11.
Ultrasound-assisted leaching-dispersive solid-phase extraction followed by dispersive liquid-liquid microextraction (USAL-DSPE-DLLME) technique has been developed as a new analytical approach for extracting, cleaning up and preconcentrating polybrominated diphenyl ethers (PBDEs) from sediment samples prior gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. In the first place, PBDEs were leached from sediment samples by using acetone. This extract was cleaned-up by DSPE using activated silica gel as sorbent material. After clean-up, PBDEs were preconcentrated by using DLLME technique. Thus, 1 mL acetone extract (disperser solvent) and 60 μL carbon tetrachloride (extraction solvent) were added to 5 mL ultrapure water and a DLLME technique was applied. Several variables that govern the proposed technique were studied and optimized. Under optimum conditions, the method detection limits (MDLs) of PBDEs calculated as three times the signal-to-noise ratio (S/N) were within the range 0.02-0.06 ng g−1. The relative standard deviations (RSDs) for five replicates were <9.8%. The calibration graphs were linear within the concentration range of 0.07-1000 ng g−1 for BDE-47, 0.09-1000 ng g−1 for BDE-100, 0.10-1000 ng g−1 for BDE-99 and 0.19-1000 ng g−1 for BDE-153 and the coefficients of estimation were ≥0.9991. Validation of the methodology was carried out by standard addition method at two concentration levels (0.25 and 1 ng g−1) and by comparing with a reference Soxhlet technique. Recovery values were ≥80%, which showed a satisfactory robustness of the analytical methodology for determination of low PBDEs concentration in sediment samples.  相似文献   

12.
The World Health Organization states that envenomation is responsible for a high number of deaths per year, especially in equatorial areas. The only effective specific treatment is the use of hyperimmune serum (antivenom). In Brazil, Crioula breed horses are used for antivenom production, with great importance in the maintenance of public health programs. A strict biochemical and metabolic control is required to attain specificity in antiserum. Inorganic elements represent only a small fraction of whole blood. Nonetheless, they play important roles in mammalian metabolism, being responsible for controlling enzymatic reactions, respiratory and cardiac functions and ageing. In this work, whole blood samples from Crioula breed horses were analyzed by EDXRF technique. The reference interval values were determined for the elements Na (1955–2013 μg g−1), Mg (51–75 μg g−1), P (523–555 μg g−1), S (1628–1730 μg g−1), Cl (2388–2574 μg g−1), K (1649–1852 μg g−1), Ca (202–213 μg g−1), Cu (4.1–4.5 μg g−1) and Zn (2.4–2.8 μg g−1) and a comparative study with NAA results was outlined. The samples were obtained from Instituto Butantan. Both techniques showed to be appropriate for whole blood sample analyses and offer a new perspective in Veterinary Medicine.  相似文献   

13.
The effect of polymer–salt addition in the activated carbon electrode for electric double-layer capacitor (EDLC) has been investigated. A series of composite thin film electrode consisting of activated carbon, carbon black, polytetrafluoroethylene and polymer–salt complex (polyethyleneoxide–LiClO4) with an appropriate weight ratio were prepared and examined their performance for EDLCs using 1 mol L−1 LiClO4 in ethylene carbonate:diethylcarbonate electrolyte solution. The electrochemical capacitance performances of these electrodes with different compositions were characterized by cyclic voltammetry, galvanostatic charge–discharge cycling, and AC impedance measurements. By comparison, the best results were obtained with a composite electrode rich in polymer–salt additive (132 F g−1 at 100 mA g−1 of galvanostatic experiment). In general, the polymer–salt-containing electrode had shown improved performance over activated carbon electrodes without polymer–salt at high current density.  相似文献   

14.
A rapid method for the extraction and determination of 90Sr in natural water, plant and sediment samples was developed using extraction chromatography and dynamic reaction cell ICP–MS, with O2 as a reaction gas. While isobaric interference from the stable isotope 90Zr was efficiently removed by this method, interferences produced from in-cell reactions with Fe+ and Ni+ required suppression by tuneable bandpass, and in sediments, additional chromatographic separation. Method detection limits were 0.1 pg g−1 (0.5 Bq g−1), 0.04 pg g−1(0.2 Bq g−1), and 3 pg L−1 (5 Bq L−1) for sediments, plant and water samples, respectively, and 90Sr concentrations determined by ICP–MS were in good agreement with activities determined by Cerenkov counting and with certified reference values. While mass spectrometric determination does not rival detection limits achievable by radiometric counting, radiometric determination of 90Sr, a pure beta-emitter, is hindered by long analysis times (several weeks); the comparatively fast analysis achieved via ICP–MS enables same-day preparation and analysis of samples, making this an important technique for the environmental monitoring of areas contaminated by radioactivity.  相似文献   

15.
A sensitive method has been developed and validated for the determination of diverse groups of pharmaceuticals, steroid hormones, and hormone-like personal care products in sewage sludge. Samples were extracted by ultrasonic-assisted extraction followed by solid-phase extraction cleanup. For determination of estrogens and hormone-like phenolic compounds, sample extracts were further derivatized with dansyl chloride and purified with silica gel column chromatography to improve the analytical sensitivity. The chemicals were determined by ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) in multiple-reaction monitoring mode. Recoveries ranged mostly from 63% to 119% with relative standard deviations within 15%. Method quantification limits were 0.1–3 ng g−1 dry weight (dw) for sewage sludge. The method was applied to a preliminary investigation of pharmaceuticals and personal care products (PPCPs) in sewage sludge and sediment in the Pearl River Delta, South China. Triclosan, triclocarban, 2-phenylphenol, bisphenol A, and parabens were ubiquitously detected at 3.6–5088.2 ng g−1 dw in sludge and 0.29–113.1 ng g−1 dw in sediment samples, respectively. Estrone, carbamazepine, metoprolol, and propranolol were also frequently quantified in the sludge and sediment samples. The dewatering process caused no significant losses of these PPCPs in sewage sludge.  相似文献   

16.
A sensitive and simple analytical method has been developed for determination of Sb(III), Sb(V), Se(IV), Se(VI), Te(IV), Te(VI), and Bi(III) in garlic samples by using hydride-generation–atomic-fluorescence spectrometry (HG–AFS). The method is based on a single extraction of the inorganic species by sonication at room temperature with 1 mol L−1 H2SO4 and washing of the solid phase with 0.1% (w/v) EDTA, followed by measurement of the corresponding hydrides generated under two different experimental conditions directly and after a pre-reduction step. The limit of detection of the method was 0.7 ng g−1 for Sb(III), 1.0 ng g−1 for Sb(V), 1.3 ng g−1 for Se(IV), 1.0 ng g−1 for Se(VI), 1.1 ng g−1 for Te(IV), 0.5 ng g−1 for Te(VI), and 0.9 ng g−1 for Bi(III), in all cases expressed in terms of sample dry weight.  相似文献   

17.
For studying the adiabatic and nonadiabatic mechanisms of the ClO (X 2Π) + ClO (X 2Π) → ClOOCl → 2Cl (2 P u) + O2 (X 3Σ g ) reaction (1) and the ClO (X 2Π) + ClO (X 2Π) → ClOOCl → Cl2 (X 1Σ g +) + O2 (X 3Σ g ) reaction (2), we calculated, by partial geometry optimizations under the C2 constraint, the O–O and O–Cl dissociation potential energy curves (PECs) from the five low-lying states of ClOOCl at the CASPT2 level. The CASSCF minimum-energy crossing point (MECP) between the potential energy surfaces of the 1 1A ground state [correlating with the product of reaction (1)] and the 1 3B state [correlating with the product of reaction (2)] states was also determined. Based on the CAS calculation results (PECs, energies, and spin–orbit coupling at the MECP), we predict that reaction (1) occurs along pathway 1: ClO (X 2Π) + ClO (X 2Π) → ClOOCl (1 1A) → 2Cl (2 P u) + O2 (X 3Σ g ) and that reaction (2) occurs along pathway 2: ClO (X 2Π) + ClO (X 2Π) → ClOOCl (1 1A) → 1 1A/1 3B MECP (142.4 cm−1) → ClOOCl (1 3B) → Cl2 (X 1Σ g +) + O2 (X 3Σ g ). The needed energies (relative to the reactant) for pathways 1 and 2 are predicted to be 5.3 and 11.1 kcal/mol, respectively, which indicates that reaction (1) is more favorable than reaction (2). The present work supports the traditional photochemical model for ozone degradation: ClOOCl (1 1A), formed by two ClO (X 2Π), can directly produce O2 plus two Cl atoms.  相似文献   

18.
The α-C–H bond dissociation enthalpy (BDE) in tetralin (1,2,3,4-tetrahydronaphtalene) was determined using time-resolved photoacoustic calorimetry as 357.6 ± 5.4 kJ mol−1. This value is some 10 kJ mol−1 higher than the only previous experimental determination but in remarkably good agreement with the α-C–H BDEs in the structurally related compounds such as 1-butene, cyclohexene, and ethylbenzene.  相似文献   

19.
In the present study, a novel analytical approach for the simultaneous determination of 27 brominated flame retardants (BFRs), namely polybrominated diphenyl ethers (PBDEs), isomers of hexabromocyclododecane (HBCD), tetrabromobisphenol A (TBBPA) and several novel BFRs (NBFRs), together with 18 perfluoroalkyl substances (PFASs) in indoor dust was developed and validated. To achieve integrated isolation of analytes from the sample and their fractionation, a miniaturized method based on matrix solid phase dispersion (MSPD) was employed. Principally, after mixing the dust (<0.1 g) with the Florisil®, the mixture was applied on the top of a sorbent (Florisil®) placed in glass column and then analytes were eluted using solvents with different polarities. For the identification/quantification of target compounds largely differing in polarity, complementary techniques represented by gas and liquid chromatography coupled to tandem mass spectrometry (GC–MS/MS and LC–MS/MS) were used. The results of validation experiments, which were performed on the SRM 2585 material (for PBDEs, HBCDs and TBBPA), were in accordance with the certified/reference values. For other analytes (NBFRs and PFASs), the analysis of an artificially contaminated blank dust sample was realized. The method recoveries for all target compounds ranged from 81 to 122% with relative standard deviations lower than 21%. The quantification limits were in the range of 1–25 ng g−1 for BFRs and 0.25–1 ng g−1 for PFASs. Finally, 18 samples (6 households × 3 sampling sites) were analyzed. The high variability between concentrations of PFASs and BFRs in the dust samples from various households as well as collecting sites in a respective house was observed. The total amounts of PFASs and BFRs were in the range of 1.58–236 ng g−1 (median 10.6 ng g−1) and 39.2–2320 ng g−1 (median 325 ng g−1), respectively. It was clearly shown that dust from the indoor environment might be a significant source of human exposure to various organohalogen pollutants.  相似文献   

20.
A rapid, sensitive and environmentally friendly method for the analysis of 14 anilines in water samples by dispersive liquid–liquid microextraction based on solidification of floating organic drop (DLLME-SFO) prior to gas chromatography–mass spectrometry (GC-MS) was developed and optimized. In the proposed method, cyclohexane was used as the extraction solvent as its toxicity was much lower than that of the solvent usually used in dispersive liquid–liquid microextraction (DLLME). In the optimized conditions, the method exhibited good analytical performance. Based on a signal-to-noise ratio of 3, limits of detection for anilines were in the range of 0.07 to 0.29 μg L−1, and the linear range was 0.5–200 μg L−1 with regression coefficients (r 2) higher than 0.9977. It was efficient for qualitative and quantitative analysis of anilines in water samples. The relative standard deviations varied from 2.9 to 8.6 % depending on different compounds indicating good precision. Tap water and river water were selected for evaluating the application to real water samples. The relative recoveries of anilines for the two real samples spiked with 10 μg L−1 anilines were in the scope of 78.2–114.6 % and 77.3–115.6 %, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号