首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We explored chromatographic conditions to obtain high resolution in protein separations by ion-exchange chromatography (IEC) on a nonporous anion-exchange resin of 2.5 microm in particle diameter. We studied the effects of gradient time (steepness of salt concentration gradient), flow-rate and column length on resolution in much wider ranges than had been studied before. It was found that two distinct conditions exist that provide high resolution. The first is a condition which has widely been employed in current high-performance IEC, namely, a combination of short gradient time, high flow-rate and comparatively short column. Separation times are usually 5-30 min, and even more rapid (1-2 min) separations are possible. The second is the condition which has rarely been employed in high-performance IEC. It is a combination of long gradient time, low flow-rate and long column. Although it takes several hours for one separation, very high resolution is attainable.  相似文献   

2.
In this study, the performance of monolithic columns was evaluated for ultrafast liquid chromatography/mass spectrometry (LC/MS) analyses and for high-resolution separations of several azaspiracid biotoxin analogs. Because of their high permeability, monolithic columns offer a number of advantages over conventional packed columns; viz., very low backpressures and relatively flat van Deemter curves at high flow rates. That is, very high flow rates can be used for ultrafast analyses or, by using longer than normal columns, high-resolution separations are possible. In a series of experiments, we varied the mobile phase flow rates between 1 and 8 mL/min, and studied their impact on chromatographic parameters such as retention time, resolution, number of plates and pressure. The chromatographic run times could be reduced to ca. 30 s without a significant change in the separation efficiency. A signal intensity comparison revealed interesting differences between atmospheric-pressure chemical ionization (APCI) and electrospray ionization (ESI) in their flow-rate dependency. An explanation with respect to the behavior as of a mass-flow or a concentration-dependent device is given in the paper. Additionally, the column length was varied between 10 and 70 cm. As a result, the number of theoretical plates increased substantially. In the example shown in the report, an increase from 13 000 plates for a 10-cm column to 80 000 for a 70-cm column is demonstrated. In addition, the potential of the monolithic columns for high-resolution LC/MS separations is shown for a complex biotoxin mixture, which was separated on a 40-cm-long column.  相似文献   

3.
Fekete S  Fekete J 《Talanta》2011,84(2):416-423
The performance of 5 cm long narrow-bore columns packed with 2.6-2.7 μm core-shell particles and a column packed with 1.7 μm totally porous particles was compared in very fast gradient separations of polar neutral active pharmaceutical compounds. Peak capacities as a function of flow-rate and gradient time were measured. Peak capacities around 160-170 could be achieved within 25 min with these 5 cm long columns. The highest peak capacity was obtained with the Kinetex column however it was found that as the flow-rate increases, the peak capacity of the new Poroshell-120 column is getting closer to that obtained with the Kinetex column. Considering the column permeability, peak capacity per unit time and per unit pressure was also calculated. In this comparison the advantage of sub-3 μm core-shell particles is more significant compared to sub-2 μm totally porous particles. Moreover it was found that the very similar sized (dp = 2.7 μm) and structured (ρ = 0.63) new Poroshell-120 and the earlier introduced Ascentis Express particles showed different efficiency. Results obtained showed that the 5 cm long narrow bore columns packed with sub-3 μm core-shell particles offer the chance of very fast and efficient gradient separations, thus these columns can be applied for fast screening measurements of routine pharmaceutical analysis such as cleaning validation.  相似文献   

4.
Although linear salt gradient elution ion-exchange chromatography (IEC) of proteins is commonly carried out with relatively short columns, it is still not clear how the column length affects the separation performance and the economics of the process. The separation performance can be adjusted by changing a combination of the column length, the gradient slope and the flow velocity. The same resolution can be obtained with a given column length with different combinations of the gradient slope and the flow velocity. This results in different separation time and elution volume at the same resolution. Based on our previous model, a method for determining the separation time and the elution volume relationship for the same resolution (iso-resolution curve) was developed. The effect of the column length and the mass transfer rate on the iso-resolution curve was examined. A long column and/or high mass transfer rate results in lesser elution volume. The resolution data with porous bead packed columns and monolithic columns were in good agreement with the calculated iso-resolution curves. Although the elution volume can be reduced with increasing column length, the pressure drop limits govern the optimum conditions.  相似文献   

5.
An optimised packing procedure for the production of high efficiency, short, particle-packed ion-exchange columns is reported. Slurry-packing techniques were applied to a series of interconnected short columns, with the columns situated intermediate between the inlet and outlet ends of the series being used for separations. The fast separation and determination of inorganic anions was achieved using short (4mm ID, 30mm long) columns packed with Dionex AS20 high-capacity anion-exchange stationary phase. Seven inorganic anions (bromate, chloride, chlorate, nitrate, sulfate, chromate and perchlorate) are separated in 2.6min using a hydroxide gradient and a flow-rate of 1.8mL/min (total analysis time including re-equilibration was 3.5min). Under isocratic conditions, the home-packed columns exhibited efficiency values of 43,000N/m for chloride at a flow-rate of 0.3mL/min, compared to 54,000N/m for a commercial 250mm AS20 column at the same flow-rate. However, the short columns gave approximately a threefold higher sample throughput. The short, home-packed columns could be produced reproducibly and gave consistent performance over extended periods of usage.  相似文献   

6.
Reversed phase gradient elution is the method of choice for pharmaceuticals analysis since it allows reducing the analysis time while improving both the quality of the separation and the detection limits. The current trends are towards faster separations which can be achieved thanks to equipments withstanding ultra-high pressures and/or high temperatures. Under such conditions, gradient separations can be carried out within a few minutes or even a few tens of seconds. A long equilibration time in addition to the gradient time can be therefore very detrimental. In this work, we investigated the extent to which the gradient equilibration time can be reduced and which parameters mainly affect the retention variability of ionizable compounds when using volatile buffers. We first found out an excellent repeatability between run-to-run experiments whatever the equilibration time and the operating conditions. We then pointed out the key operating parameters which allow achieving reproducible runs when varying the equilibration time between runs. With a view of reducing the equilibration time, the effects of various conditions were examined. The latter include the type of additive for mobile phase pH adjustment, the initial eluent composition, the type of stationary phase, the temperature and the flow-rate. Although much remains to be understood about the equilibration process, our study allows making progress in the knowledge of this phenomenon. Based on the present results, a beneficial effect of both temperature and flow-rate was highlighted and operating conditions leading to faster column equilibration are suggested.  相似文献   

7.
In this work, monolithic silica columns with the C4, C8, and C18 chemistry and having various macropore diameters and two different mesopore diameters are studied to access the differences in the column efficiency under isocratic elution conditions and the resolution of selected peptide pairs under reversed-phase gradient elution conditions for the separation of peptides and proteins. The columns with the pore structural characteristics that provided the most efficient separations are then employed to optimize the conditions of a gradient separation of a model mixture of peptides and proteins based on surface chemistry, gradient time, volumetric flow rate, and acetonitrile concentration. Both the mesopore and macropore diameters of the monolithic column are decisive for the column efficiency. As the diameter of the through-pores decreases, the column efficiency increases. The large set of mesopores studied with a nominal diameter of approximately 25 nm provided the most efficient column performance. The efficiency of the monolithic silica columns increase with decreasing n-alkyl chain length in the sequence of C18相似文献   

8.
The rapid separation of inorganic anions on short monolithic columns permanently coated with a long chained zwitterionic carboxybetaine-type surfactant is shown. The surfactant, N-dodecyl-N,N-(dimethylammonio)undecanoate (DDMAU), was used to coat 2.5, 5.0 and 10 cm long reversed-phase silica monoliths, resulting in a permanent zwitterionic exchange surface when used with aqueous based eluents. The unique structure of the surfactant results in a charge double layer structure on the surface of the stationary phase, with strong internal anionic and weak external cationic exchange groups. The dissociation of the weak external carboxylic acid group acts to shield the inner anionic exchange site, resulting in substantial effective capacity changes with eluent pH. Utilising this effect with the application of an eluent pH gradient, simultaneously combined with eluent flow-rate gradients, very rapid simultaneous separations of both weakly retained anions and strongly retained polarisable anions was possible, with up to 10-fold decreases in overall run times. Coating stability and retention times under isocratic and isofluentic eluent conditions were shown to be reproducible over >450 repeat injections, with peak efficiency values averaging 29,000 N/m for the 2.5 cm column and 42,000 N/m for the 10 cm monolithic column, again under isocratic elution conditions.  相似文献   

9.
The potential of high-speed analyses by rapid resolution liquid chromatography (RRLC) and RRLC/MS on 1.8-microm porous particles packed into short columns operated at high flow-rate was investigated and compared with the performance of 5-microm porous particles packed into conventional columns. Using similar chemistries, the ease of conversion from conventional HPLC to an RRLC method was demonstrated. In order to display the practicality of RRLC separations, the analysis of pesticides in crops and catechins in Japanese green tea was selected. Using the Japanese Food Hygiene Law method, which employs a conventional 5-microm RP column (250 mm x 4.6 mm) for quantification of pesticides in crops, the analysis time was 25 min under isocratic conditions. Using the RRLC method on the short (50 mm x 4.6 mm) column packed with 1.8-microm porous particles, the same separation could be performed in 0.8 min with the RRLC/MS method without a loss in resolution. At the highest flow rate, compared to the conventional method, the time could be reduced by a factor of 31. In gradient elution, the fastest separation of catechins in Japanese green tea was achieved by RRLC on 50-mm x 4.6-mm id or 50-mm x 2.1-mm id RRLC columns packed with 1.8-microm particles. The analysis time at 5 mL/min was less than 1 min. Compared to the conventional HPLC method on a 150-mm column packed with 5-microm particles, time was reduced by a factor of 15. The effect of other experimental parameters such as the column temperature, acquisition rate of the detector and the influence of cell volume on chromatographic performance was also investigated. After the optimization, the analysis precision under the fastest RRLC conditions was examined. RSDs of retention time and peak area were 0.2% and 0.47%, respectively.  相似文献   

10.
Maximization of peak capacity is a very important step in developing one-dimensional separations of complex samples. In recent work, it was shown that the use of small particles in combination with the new technique of ultrahigh pressure liquid chromatography (UHPLC) was able to generate very high peak capacities. Here we show the ability of conventional HPLC instrumentation to give comparable peak capacities to those obtained in UHPLC for the important case of complex mixtures of peptides but at much lower pressures by using a 60 cm long set of columns packed with 5 microm pellicular (superficially porous) particles. We first show, in complete agreement with the well known results of the theory of isocratic separations that, when time is not limiting, the best peak capacities in gradient elution chromatography are obtained by using large particles and the longest column that can be operated at the pump's pressure limit. Two different types of 5 microm particles (superficially porous and totally porous) were compared for their efficiency in gradient chromatography of peptides. We find that the pellicular material gave about 50% higher peak capacity compared to the analogous porous material. A 60 cm column set packed with pellicular particles was made by connecting short columns in series; a peak capacity of about 460 was obtained in 4 h at room temperature. Increasing the column temperature to 70 degrees C reduced the analysis time to 2 h and further increased the peak capacity to more than 500. The number of peaks observed in the separation of bovine serum albumin tryptic peptides was greatly increased and the separation quality was significantly improved.  相似文献   

11.
Protein mapping by two-dimensional high performance liquid chromatography   总被引:11,自引:0,他引:11  
Current developments in drug discovery in the pharmaceutical industry require highly efficient analytical systems for protein mapping providing high resolution, robustness, sensitivity, reproducibility and a high throughput of samples. The potential of two-dimensional (2D) HPLC as a complementary method to 2D-gel electrophoresis is investigated, especially in view of speed and repeatability. The method will be applied for proteins of a molecular mass <20 000 which are not well resolved in 2D-gel electrophoresis. The 2D-HPLC system described in this work consisted of anion- or cation-exchange chromatography in the first dimension and reversed-phase chromatography in the second dimension. We used a comprehensive two-dimensional approach based on different separation speeds. In the first dimension 2.5 microm polymeric beads bonded with diethylaminoethyl and sulfonic acid groups, respectively, were applied as ion exchangers and operated at a flow-rate of 1 ml/min. To achieve very high-speed and high-resolution separations in the second dimension, short columns of 14 x 4.6 mm I.D. with 1.5 microm n-octadecyl bonded, non-porous silica packings were chosen and operated at a flow-rate of 2.5 ml/min. Two reversed-phase columns were used in parallel in the second dimension. The analyte fractions from the ion-exchange column were transferred alternatively to one of the two reversed-phase columns using a 10-port switching valve. The analytes were deposited in an on-column focusing mode on top of one column while the analytes on the second column were eluted. Proteins, which were not completely resolved in the first dimension can, in most cases, be baseline-separated in the second dimension. The total value of peak capacity was calculated to 600. Fully unattended overnight runs for repeatability studies proved the applicability of the system. The values for the relative standard deviation (RSD) of the retention times of proteins were less than 1% (n = 15), while the RSDs of the peak areas were less than 15% (n = 15) on average. The limit of detection was 300 ng of protein on average and decreased to 50 ng for ovalbumin. The 2D-HPLC system offered high-resolution protein separations with a total analysis time of less than 20 min, equivalent to the run time of the first dimension.  相似文献   

12.
A novel graphical method for assessing the compromise between conditional peak capacity and separation speed for packed bed columns under gradient conditions has been developed and applied to the separation of peptides. This approach is analogous to and complements the conventional "Poppe plot" used to study plate count in isocratic separations. The use of the new plot can assist the design of appropriate column formats (e.g. particle size and column length) for both dimensions in gradient elution two-dimensional liquid chromatography (2DLC). Particularly for the second dimension of 2DLC, we find that smaller particles provide faster separations even though fast separations based on particles smaller than 2 microm are practically limited by the required miniscule column length. We also find that high temperatures strongly enhance the kinetics of peak capacity production whereas higher pressures help achieve larger absolute peak capacities albeit at the cost of longer analysis time.  相似文献   

13.
The effect of combining sub-2 microm porous particles with elevated operating temperatures on chromatographic performance has been investigated in terms of chromatographic efficiency, productivity, peak elution order, and observed operating pressure. The use of elevated temperature in LC does not increase the obtainable performance but allows the same performance to be obtained in less time. Increasing the column temperature did allow the use of longer columns, generating column efficiencies in excess of 100,000 plates and gradient peak capacities approaching 1000. Raising the temperature increased the optimal mobile phase linear velocity, negating somewhat the pressure benefits observed by reducing the solvent viscosity. When operating at higher temperature the analyte retention is not only reduced, but the order of elution will also often change. High temperature separations allowed exotic organic modifiers such as isopropanol to be exploited for alternative selectivity and faster analysis. Finally, care must be taken when using high temperature separations to ensure that the narrow peak widths produced do not compromise the quality of data obtained from detectors such as high resolution mass spectrometers.  相似文献   

14.
Abstract

Separations on short columns, (3 and 5 cm, packed with 3 μ ODS spherical materials) and somewhat larger ones (10 cm and 20 cm columns having 2.1 mm and 4.6 mm diameters packed with 5 μ ODS spherical materials) were compared using Aroclor 1254. With simple mixtures, the results showed that short columns can give separations comparable with those on longer columns when the percentage of the organic modifier in the mobile phase is adjusted. This was not so with more complex mixture. The results also showed that columns which have a comparable volume do not produce comparable separation. The longer column, 200 mm × 2.1 mm gave better resolution than the shorter 50 mm × 4 mm column. Also a shorter column, (100 mm × 4.6 mm), which had double the volume of a longer column. (200 mm × 2.1 mm), gave better resolution of the Aroclor 1254 test solution.  相似文献   

15.
在蛋白质组学研究中,多肽混合物的有效分离对蛋白质鉴定和蛋白质之间相互作用的研究起着决定性的影响。基于此,用反相液相色谱研究了在两个不同长度的色谱柱上分离多肽混合物时色谱柱长度与峰容量的关系,同时考察了梯度洗脱时间对峰容量和峰宽的影响。实验结果表明,色谱柱长度对峰容量有显著的影响,而延长梯度洗脱时间不仅可以增加峰容量,而且可以增加峰宽。这说明用毛细管液相色谱 串联质谱联用方法对多肽混合物进行分离鉴定时,采用较长的色谱柱和较长的梯度洗脱时间有利于对更多的多肽进行分析鉴定。  相似文献   

16.
The gain in separation efficiency for protein digests using long monolithic columns has been evaluated for a LC‐MS system with capillary monolithic columns of different lengths (150 and 750 mm). A mixture of BSA, α‐casein and β‐casein tryptic digests was used as a test sample. Peak capacity and productivity (peak capacity per unit time) were determined from base peak chromatograms and MS/MS data were used for protein identification by MASCOT database searching. Peak capacity and protein identification scores were higher for the long column. Analyses with similar gradient slope for the two columns produced ratios of the peak capacities that were slightly higher than the expected value of the square root of the column length ratio. Peak capacity ratios varied from 2.7 to 4.0 for four different gradient slopes, while protein identification scores were 2–4 times higher for the long column. Similar values were obtained for the productivity of both columns and the highest productivity was obtained at gradient times of 45 and 75 min for the short and long column, respectively. The use of long monolithic columns improves peptide separation and increases reliability of protein identification for complex digests, especially if longer gradients are chosen.  相似文献   

17.
In this study, high-efficiency LC–MS/MS separations of complex proteolytic digests are demonstrated using 50 mm, 250 mm, and 1 m long poly(styrene-co-divinylbenzene) monolithic capillary columns. The chromatographic performance of the 50 and 250 mm monoliths was compared at the same gradient steepness for gradient durations between 5 and 150 min. The maximum peak capacity of 400 obtained with a 50 mm column, increased to 485 when using the 250 mm long column and scaling the gradient duration according column length. With a 5-fold increase in column length only a 20% increase in peak capacity was observed, which could be explained by the larger macropore size of the 250 mm long monolith. When taking into account the total analysis time, including the dwell time, gradient time and column equilibration time, the 50 mm long monolith yielded better peptide separations than the 250 mm long monolithic column for gradient times below 80 min (nc = 370). For more demanding separation the 250 mm long monolith provided the highest peak production rate and consequently higher sequence coverage. For the analysis of a proteolytic digest of Escherichia coli proteins a monolithic capillary column of 1 m in length was used, yielding a peak capacity of 1038 when applying a 600 min gradient.  相似文献   

18.
The performance of 5 and 15 cm long columns packed with shell particles (Halo, AMT) is compared in gradient elution separations of the tryptic digests of myoglobin and bovine serum albumin. The influences of the temperature and the mobile phase flow rate on the column efficiency for two peptides are discussed. The influences of this flow rate, of the temperature, and of the gradient slopes on the peak capacities are also considered. Peak capacities in excess of 400 were achieved in 6h with the longer column. Peak capacities of 200 could be achieved in 30 min with the shorter column.  相似文献   

19.
Ultra-fast chromatographic separations has enabled fast chromatographic method development and rapid analysis for sample quantification. Decreasing over-all analytical time has become a factor of major importance for all aspects of drug discovery. However, merely decreasing chromatographic analysis time by decreasing k' can lead to inconsistent quantitative or qualitative results due to ineffective separations in complex matrices. We have found that by changing column length and gradient slope we can maintain chromatographic integrity of chemically diverse analytes and achieve the analytical speed required for bioanalytical drug discovery quantitative analysis. We have optimized method development strategy by performing separations on 2x20 mm HPLC columns at flow-rates of 1.5 ml/min to 2 ml/min with full linear gradients achieved in 1 min for the quantification of pharmaceuticals and their metabolites from biological matrices. This method development strategy can be readily adapted to other matrices. This paper will discuss the effects of column length and gradient time in ultra-fast chromatographic resolution.  相似文献   

20.
A HPLC column devised for high separation speed combined with highly practical operating features has been found useful for separating antibiotics. Important characteristics involve compromises in packing particle size, column configuration and support-stationary phase combinations. We determined that these columns are useful for rapid, high-resolution separations with unmodified state-of-the-art HPLC equipment without the extra-column band-broadening effects typical of so-called “fast” HPLC columns. The proposed columns feature efficient sterically-protected monofunctional silane stationary phases that provide good separation reproducibility and high column stability. The combination of these unique bonded silanes and a highly purified, less-acidic silica support give superior peak shapes for antibiotic compounds. The proposed column configuration can halve separation times and double peak heights without loss in resolution, compared to widely used analytical columns. Increased mobile phase flow-rates permit even faster separations of antibiotics with only modest loss in resolution and peak heights for trace analyses in biological systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号