Herein we report the development of solid‐phase microextraction (SPME) devices designed to perform fast extraction/enrichment of target analytes present in small volumes of complex matrices (i.e. V≤10 μL). Micro‐sampling was performed with the use of etched metal tips coated with a thin layer of biocompatible nano‐structured polypyrrole (PPy), or by using coated blade spray (CBS) devices. These devices can be coupled either to liquid chromatography (LC), or directly to mass spectrometry (MS) via dedicated interfaces. The reported results demonstrated that the whole analytical procedure can be carried out within a few minutes with high sensitivity and quantitation precision, and can be used to sample from various biological matrices such as blood, urine, or Allium cepa L single‐cells.  相似文献   

2.
3.
Asghar W  Wan Y  Ilyas A  Bachoo R  Kim YT  Iqbal SM 《Lab on a chip》2012,12(13):2345-2352
Solid-state micropores can provide direct information of ex vivo or in vitro cell populations. Micropores are used to detect and discriminate cancer cells based on the translocation behavior through micropores. The approach provides rapid detection of cell types based on their size and mechano-physical properties like elasticity, viscosity and stiffness. Use of a single micropore device enables detection of tumor cells from whole blood efficiently, at 70% CTC detection efficiency. The CTCs show characteristic electrical signals which easily distinguish these from other cell types. The approach provides a gentle and inexpensive instrument that can be used for specific blood analysis in a lab-on-a-chip setting. The device does not require any preprocessing of the blood sample, particles/beads attachment, surface functionalization or fluorescent tags and provides quantitative and objective detection of cancer cells.  相似文献   

4.
Microsample preparation by dielectrophoresis: isolation of malaria   总被引:1,自引:0,他引:1  
An important enabling factor for realising integrated micro fluidic analysis instruments for medical diagnostics purposes is front-end sample preparation. Dielectrophoresis is a method that offers great potential for cell discrimination and isolation for sample processing, and here we have applied it to the problem of isolating malaria-infected cells from blood. During development of the malarial pathogen, Plasmodium falciparum, increases occur in the ionic permeability of the plasma membrane of infected erythrocytes. When challenged by suspension in a low conductivity medium, infected cells lose internal ions while uninfected cells retain them. The resultant dielectric differences between infected and uninfected cells were exploited by dielectrophoretic manipulation in spatially inhomogeneous, travelling electrical fields produced by two types of microelectrode arrays. Parasitised cells of ring form or later stage from cultures and clinical specimens were isolated by steric dielectric field-flow-fractionation, focused at the centre of a spiral electrode array, and identified and counted. The dielectrophoretic methods require only a few micro litres of blood, and should be applicable to the production of small, low-cost automated devices for assessing parasite concentrations with potential applicability to drug sensitivity studies and the diagnosis of malaria. By simple adjustment of the electrical field parameters, other cell subpopulations that characterise disease, such as residual cancer cells in blood, can be similarly isolated and analysed.  相似文献   

5.
Bhagat AA  Hou HW  Li LD  Lim CT  Han J 《Lab on a chip》2011,11(11):1870-1878
Blood is a highly complex bio-fluid with cellular components making up >40% of the total volume, thus making its analysis challenging and time-consuming. In this work, we introduce a high-throughput size-based separation method for processing diluted blood using inertial microfluidics. The technique takes advantage of the preferential cell focusing in high aspect-ratio microchannels coupled with pinched flow dynamics for isolating low abundance cells from blood. As an application of the developed technique, we demonstrate the isolation of cancer cells (circulating tumor cells (CTCs)) spiked in blood by exploiting the difference in size between CTCs and hematologic cells. The microchannel dimensions and processing parameters were optimized to enable high throughput and high resolution separation, comparable to existing CTC isolation technologies. Results from experiments conducted with MCF-7 cells spiked into whole blood indicate >80% cell recovery with an impressive 3.25 × 10(5) fold enrichment over red blood cells (RBCs) and 1.2 × 10(4) fold enrichment over peripheral blood leukocytes (PBL). In spite of a 20× sample dilution, the fast operating flow rate allows the processing of ~10(8) cells min(-1) through a single microfluidic device. The device design can be easily customized for isolating other rare cells from blood including peripheral blood leukocytes and fetal nucleated red blood cells by simply varying the 'pinching' width. The advantage of simple label-free separation, combined with the ability to retrieve viable cells post enrichment and minimal sample pre-processing presents numerous applications for use in clinical diagnosis and conducting fundamental studies.  相似文献   

6.
Binding of monoclonal antibodies (mAbs) onto a cell surface triggers antibody‐mediated effector killing by innate immune cells through complement activation. As an alternative to mAbs, synthetic systems that can recruit endogenous antibodies from the blood stream to a cancer cell surface could be of great relevance. Herein, we explore antibody‐recruiting polymers (ARPs) as a novel class of immunotherapy. ARPs consist of a cell‐binding motif linked to a polymer that contains multiple small molecule antibody‐binding motifs along its backbone. As a proof of concept, we employ a lipid anchor that inserts into the phospholipid cell membrane and make use of a polymeric activated ester scaffold onto which we substitute dinitrophenol as an antibody‐binding motif. We demonstrate that ARPs allow for high avidity antibody binding and drive antibody recruitment to treated cells for several days. Furthermore, we show that ARP‐treated cancer cells are prone to antibody‐mediated killing through phagocytosis by macrophages.  相似文献   

7.
In biomedical research and clinical diagnostics, it is a major challenge to measure disease‐related degradative enzyme activity directly in whole blood. Present techniques for assaying degradative enzyme activity require sample preparation, which makes the assays time‐consuming and costly. This study now describes a simple and rapid electrophoretic method that allows detection of degradative enzyme activity directly in whole blood using charge‐changing fluorescent peptide substrates. Charge‐changing substrates eliminate the need for sample preparation by producing positively charged cleavage fragments that can be readily separated from the oppositely charged fluorescent substrate and blood components by electrophoresis. Two peptide substrates have been developed for pancreatic α‐chymotrypsin and trypsin. For the first substrate, a detection limit of 3 ng for both α‐chymotrypsin and trypsin was achieved in whole rat blood using a 4% agarose gel. This substrate had minimal cross‐reactivity with the trypsin‐like proteases thrombin, plasmin, and kallikrein. For the second substrate (trypsin‐specific), a detection limit of about 10–20 pg was achieved using thinner higher resolution 20 and 25% polyacrylamide gels. Thus, the new charge changing peptide substrates enable a simple electrophoretic assay format for the measurement of degradative enzyme activity, which is an important step toward the development of novel point‐of‐care diagnostics.  相似文献   

8.
Amphiphilic copolymers using hydrophilic N,N‐dimethylacrylamide (DMA), hydrophobic methyl methacrylate (MMA) and a crosslinkable monomer, 3‐methacryloyloxypropyl trimethoxysilane (MTSi), were synthesized and evaluated as coating materials for leukocyte removal filters for whole blood. When filters composed of non‐woven fabrics were coated with crosslinked synthesized copolymers, the elution ratios of the copolymers to water were adequately low because of the crosslinking with trimethoxysilane groups of MTSi units in the copolymers. Filters coated with crosslinked poly(DMA‐co‐MTSi) having a 0.96 mole fraction of DMA units showed a 0.35 ± 0.44% platelet permeation ratio and a logarithmic reduction of 4.0 ± 0.68 for leukocytes. On the other hand, an increase in the content of MMA units in the DMA‐containing copolymers improved the permeation ratio of the platelets dramatically. Filters coated with crosslinked poly(DMA‐co‐MMA‐co‐MTSi) containing a 0.39 mole fraction of MMA units and a 0.58 mole fraction of DMA units showed an 86 ± 3.0% platelet permeation ratio and a logarithmic reduction of 2.1 ± 1.2 for leukocytes. This indicates that an adequate content of hydrophobic monomer units, such as MMA units, is necessary for effective platelet permeation. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

9.
Circulating tumor cells are specifically referred as cells that detached from the primary tumor and are present in the bloodstream. They could be isolated from blood and used as representative biomarker for predicting cancer prognoses. Here, we developed a microfluidic chip with multiple curved channels, in which DNA fragments and antibody‐based enrichment are exploited to capture circulating tumor cells in blood sample. By introducing DNA fragments as long tentacles, the active antibody could be extended into the microchannel stereoscopically, which could greatly increase the chances of adhesion in a multidirectional way and improve the capture efficacy. Several pivotal factors for cell capturing were optimized to the best state. Compared to conventional chips for planar capturing, the capture efficiency of MCF‐7 cells was greatly increased from 37.17 to 85.10%. For the detection of MCF‐7‐containing artificial blood sample detection, the capture efficiency of tumor cells was about 74.19 ± 2.13%, which was obviously better than the result of flow cytometry (29.67 ± 4.02%). Captured cells were easily released from the surface of microfluidic chip with high cell viability, which could be investigated for the molecular analysis in the field of tumor diagnosis.  相似文献   

10.
Park S  Zhang Y  Wang TH  Yang S 《Lab on a chip》2011,11(17):2893-2900
Biological sample processing involves purifying target analytes from various sample matrices and concentrating them to a small volume from a large volume of crude sample. This complex process is the major obstacle for developing a microfluidic diagnostic platform. In this study, we present a microfluidic device that can continuously separate and concentrate pathogenic bacterial cells from complex sample matrices such as cerebrospinal fluid and whole blood. Having overcome critical limitations of dielectrophoretic (DEP) operation in physiological media of high conductivity, we utilized target specific DEP techniques to incorporate cell separation, medium exchange, and target concentration into an integrated platform. The proposed microfluidic device can uptake mL volumes of crude biological sample and selectively concentrate target cells into a submicrolitre volume, providing ~10(4) fold of concentration. We designed the device based on the electrokinetic theory and electric field simulation, and tested the device performance with different sample types. The separation efficiency of the device was as high as 97.0% for a bead mixture in TAE buffer and 94.3% and 87.2% for E. coli in human cerebrospinal fluid and blood, respectively. A capture efficiency of 100% was achieved in the concentration chamber. With a relatively simple configuration, the proposed device provides a robust method of continuous sample processing, which can be readily integrated into a fully automated microfluidic diagnostic platform for pathogen detection and quantification.  相似文献   

11.
A fabrication platform for realizing integrated microfluidic devices is discussed. The platform allows for creating specific microsystems for multistep assays in an ad hoc manner as the components that perform the assay steps can be created at any location inside the device via in situ fabrication. The platform was utilized to create a prototype microsystem for detecting botulinum neurotoxin directly from whole blood. Process steps such as sample preparation by filtration, mixing and incubation with reagents was carried out on the device. Various microfluidic components such as channel network, valves and porous filter were fabricated from prepolymer mixture consisting of monomer, cross-linker and a photoinitiator. For detection of the toxoid, biotinylated antibodies were immobilized on streptavidin-functionalized agarose gel beads. The gel beads were introduced into the device and were used as readouts. Enzymatic reaction between alkaline phosphatase (on secondary antibody) and substrate produced an insoluble, colored precipitate that coated the beads thus making the readout visible to the naked eye. Clinically relevant amounts of the toxin can be detected from whole blood using the portable enzyme-linked immunosorbent assay (ELISA) system. Multiple layers can be realized for effective space utilization and creating a three-dimensional (3-D) chaotic mixer. In addition, external materials such as membranes can be incorporated into the device as components. Individual components that were necessary to perform these steps were characterized, and their mutual compatibility is also discussed.  相似文献   

12.
《Electroanalysis》2005,17(13):1171-1180
In this paper, we describe a microchip‐based system for amperometrically monitoring the amount of catecholamines released from rat pheochromocytoma (PC 12) cells. Key to this system is a novel, yet simple method for the immobilization of PC 12 cells in poly(dimethylsiloxane) (PDMS)‐based microchannels. The procedure involves selectively coating microchannels with collagen followed by introduction of PC 12 cells over the PDMS structure, with the cells being immobilized only on the coated portion of the channels. The cell‐coated microchannels can then be reversibly sealed to a glass plate containing electrodes for amperometric detection, resulting in an immobilized cell reactor with integrated microelectrodes. Nafion‐coated microelectrodes made by micromolding of carbon inks were used to measure calcium‐induced catecholamine release from the cells. Varying concentrations of PC 12 cells immobilized in the microchannels led to a catecholamine release ranging from 20 to 160 μM when the cells were stimulated with a calcium solution. This microchip approach leads to a three‐dimensional culture that can be used with this or other cells lines to study the effect of external stimuli on neurotransmitter release.  相似文献   

13.
Recent evidence implicating leukocytes in angiogenesis raises the question of whether leukocytes and other cells circulating with the blood in microvascular networks can home to capillary sprouts intraluminally. This study describes an investigation of leukocyte trafficking in sprouting capillaries fabricated using soft lithography. The leukocytes passing with whole blood through existing capillaries were able to enter microfabricated capillary sprouts of variable length and sprouting angle due to the mechanical interaction with red blood cells (RBCs) at the sprouting bifurcation, in spite of the complete absence of blood flow through the blind-ended sprouts or any chemoattractants. The RBCs formed "comet tails" (the densely packed cellular trains forming behind leukocytes as they move through narrow capillaries) and effectively pushed leukocytes into the microfabricated sprouts while bypassing them at the sprouting bifurcation. Individual sprouts filled with several leukocytes, as wells as RBCs and platelets, were observed. The results of this study suggest that (i) blood cells are likely present in capillary sprouts throughout their development, (ii) leukocytes and other circulating cells may use this mechanism to home to capillary sprouts intraluminally for direct engraftment, and (iii) tissues may use this phenomenon as another mechanism for local recruitment of leukocytes from the blood stream.  相似文献   

14.
A novel microfluidic device that can selectively and specifically isolate exceedingly small numbers of circulating tumor cells (CTCs) through a monoclonal antibody (mAB) mediated process by sampling large input volumes (>/=1 mL) of whole blood directly in short time periods (<37 min) was demonstrated. The CTCs were concentrated into small volumes (190 nL), and the number of cells captured was read without labeling using an integrated conductivity sensor following release from the capture surface. The microfluidic device contained a series (51) of high-aspect ratio microchannels (35 mum width x 150 mum depth) that were replicated in poly(methyl methacrylate), PMMA, from a metal mold master. The microchannel walls were covalently decorated with mABs directed against breast cancer cells overexpressing the epithelial cell adhesion molecule (EpCAM). This microfluidic device could accept inputs of whole blood, and its CTC capture efficiency was made highly quantitative (>97%) by designing capture channels with the appropriate widths and heights. The isolated CTCs were readily released from the mAB capturing surface using trypsin. The released CTCs were then enumerated on-device using a novel, label-free solution conductivity route capable of detecting single tumor cells traveling through the detection electrodes. The conductivity readout provided near 100% detection efficiency and exquisite specificity for CTCs due to scaling factors and the nonoptimal electrical properties of potential interferences (erythrocytes or leukocytes). The simplicity in manufacturing the device and its ease of operation make it attractive for clinical applications requiring one-time use operation.  相似文献   

15.
《Electroanalysis》2018,30(8):1584-1603
In cancer, screening and early detection are critical for the success of the patient's treatment and to increase the survival rate. The development of analytical tools for non‐invasive detection, through the analysis of cancer biomarkers, is imperative for disease diagnosis, treatment and follow‐up. Tumour biomarkers refer to substances or processes that, in clinical settings, are indicative of the presence of cancer in the body. These biomarkers can be detected using biosensors, that, because of their fast, accurate and point of care applicability, are prominent alternatives to the traditional methods. Moreover, the constant innovations in the biosensing field improve the determination of normal and/or elevated levels of tumour biomarkers in patients’ biological fluids (such as serum, plasma, whole blood, urine, etc.). Although several biomarkers (DNA, RNA, proteins, cells) are known, the detection of proteins and circulating tumour cells (CTCs) are the most commonly reported due to their approval as tumour biomarkers by the specialized entities and commonly accepted for diagnosis by medical and clinical teams. Therefore, electrochemical immunosensors and cytosensors are vastly described in this review, because of their fast, simple and accurate detection, the low sample volumes required, and the excellent limits of detection obtained. The biosensing strategies reported for the six most commonly diagnosed cancers (lung, breast, colorectal, prostate, liver and stomach) are summarized and the distinct phases of the sensors’ constructions (surface modification, antibody immobilization, immunochemical interactions, detection approach) and applications are discussed.  相似文献   

16.
TF Wu  Z Mei  YH Lo 《Lab on a chip》2012,12(19):3791-3797
We demonstrated a unique optofluidic lab-on-a-chip device that can measure optically encoded forward scattering signals. From the design of the spatial pattern, we can measure the position and velocity of each cell in the flow and generate a 2-D cell distribution plot over the cross section of the channel. Moreover, we have demonstrated that the cell distribution is highly sensitive to its size and stiffness. The latter is an important biomarker for cell classification and our method offers a simple and unequivocal method to classify cells by their size and stiffness. We have proved the concept using live and fixed HeLa cells. Due to the stiffness and size difference of neutrophils compared to other types of white blood cells, we have demonstrated detection of neutrophils from other blood cells. Finally, we have performed the test using 5 μL of human blood. In a greatly simplified blood preparation process, skipping the usual steps of anticoagulation, centrifuge, antibody labelling or staining, filtering, etc., we have demonstrated that our device and detection principle can count neutrophils in whole human blood. Our system is compact, inexpensive and simple to fabricate and operate, having a commodity laser diode and a Si PIN photoreceiver as the main pieces of hardware. Although the results are still preliminary, the studies indicate that this optofluidic device holds promise to be a point-of-care and home care device to measure neutrophil concentration, which is the key indicator of the immune functions for cancer patients undergoing chemotherapy.  相似文献   

17.
Protein-A or goat anti-mouse-Ig (GAMIg) covalently bound to agarose-polyacrolein microsphere beads (APAMB) were employed for the removal of T cells from human peripheral blood leukocytes (PBL) and bone marrow (BM). The cell suspensions were treated with a monoclonal anti-T cell antibody (Leu-1) or monoclonal antilymphocyte antibody (CAMPATH-1) and passed through the conjugated APAMB columns. Cell separation efficacy was determined by assaying the number and function of T cells in the final cell preparation in comparison with a sample of unseparated cells. The number of cells that form rosettes (E-RFC) with sheep red blood cells (SRBC) in a sample of PBL treated with anti-Leu-1 antibodies and subsequently passed once through GAMIg-conjugated APAMB dropped from a range of 41.5–86.0% to a range of 1.6–13.3%. The in vitro response to concanavalin-A (Con-A) dropped to a range of 0.7–27.2% (GAMIg) and a range of 1.2–21.8% (protein-A column) of the response of untreated PBL. Treatment with CAMPATH-1 antibody and passage through a protein-A-conjugated APAMB reduced E-RFC from a range of 55.6–57.4% to a range of 3.2–3.9% and abolished the Con-A induced proliferative responsiveness to background levels. Treatment of BM cells with CAMPATH-1 and passage of the cells through either GAMIg or protein-A conjugated APAMB columns resulted in reduction of E-RFC from a range of 12.4–17.7% to a range of 0–1% and from a range of 17.7–19% to a range of 1.6–3.2%, respectively. Viability of BM precursors, determined by the CFU-GM assay in semisolid medium, was not affected by these cell separation procedures. The data suggest that protein-A or GAMIg-conjugated APAMB columns may be a useful tool for separation of BM cell suspensions into specific cell subsets that can be defined by monoclonal antibodies.  相似文献   

18.
Park JY  Kim HO  Kim KD  Kim SK  Lee SK  Jung H 《The Analyst》2011,136(13):2831-2836
Leukocyte adhesion to the endothelium through surface molecules such as E-selectin and intercellular adhesion molecule-1 (ICAM-1) is a critical cellular event reflecting the physiological status of both cell types. Here we present a microfluidic system that can not only easily monitor the interaction between leukocytes and endothelial cells under physiological conditions, but also screen drug candidates for potential modulation of this interaction. Shear stress, which is an important factor for the binding of activated T cells to tumor necrosis factor-alpha (TNF-α)-treated human umbilical vein endothelial cells (HUVECs), was easily controlled by adjusting the flow rate in the microfluidic system. Whole blood of patients with systemic lupus erythematosus (SLE) who have auto-reactive T cells were infused into the activated HUVECs which subsequently showed a higher level of binding compared to a control blood sample from a person without SLE. When these autoreactive T cells were treated with immunosuppressors tacrolimus and cyclosporin A, the binding of the T cells to HUVECs was dramatically decreased. Therefore, this microfluidic system is capable of differentiating the physiological status of T cells or endothelial cells representing different disease conditions, as well as being useful for the identification of novel reagents that modulate the functions of leukocytes or endothelial cells.  相似文献   

19.
Microfluidic adhesion-based cell separation systems are of interest in clinical and biological applications where small sample volumes must be processed efficiently and rapidly. While the ability to capture rare cells from complex suspensions such as blood using microfluidic systems has been demonstrated, few methods exist for rapid and nondestructive release of the bound cells. Such detachment is critical for applications in tissue engineering and cell-based therapeutics in contrast with diagnostics wherein immunohistochemical, proteomic, and genomic analyses can be carried out by simply lysing captured cells. This paper demonstrates how the incorporation of four-arm amine-terminated poly(ethylene glycol) (PEG) molecules along with antibodies within alginate hydrogels can enhance the ability of the hydrogels to capture endothelial progenitor cells (EPCs) from whole human blood. The hydrogel coatings are applied conformally onto pillar structures within microfluidic channels and their dissolution with a chelator allows for effective recovery of EPCs following capture.  相似文献   

20.
A novel microfluidic method of continually detecting and counting beads‐labeled cells from a cell mixture without fluorescence labeling was presented in this paper. The detection system is composed of a microfluidic chip (with a permanent magnet inserted along the channel), a signal amplification circuit, and a LabView® based data acquisition device. The microfluidic chip can be functionally divided into separation zone and detection zone. By flowing the pre‐labeled sample solution, the target cells will be sequentially separated at the separation zone by the permanent magnet and detected and counted at the detection zone by a microfluidic resistive pulse sensor. Experiments of positive separation and detection of T‐lymphocytes and negative separation and detection of cancer cells from the whole blood samples were carried out to demonstrate the effectiveness of this method. The methodology of utilizing size difference between magnetic beads and cell‐magnetic beads complex for beads‐labeled cell detection is simple, automatic, and particularly suitable for beads‐based immunoassay without using fluorescence labeling.  相似文献   