首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 921 毫秒
1.
Rapid ion chromatographic separations of small inorganic anions are performed on columns packed with high-pH resistant Zorbax Extend-C18 1.8 microm silica particles. Seven anions (iodate, chloride, nitrite, bromide, nitrate, phosphate, sulphate) are separated with 1.3 and 2 cm long x 0.46 cm I.D. C18 columns coated with the surfactant didodecyldimethylammonium bromide (DDAB). A 40 s separation is achieved at 2 mL/min with a 2.5 mM 4-hydroxybenzoic acid eluent at pH 10. Finally, the DDAB removal procedure is improved to eliminate the pressure build-up caused by precipitation of the surfactant in the column upon uncoating.  相似文献   

2.
The rapid separation of inorganic anions on short monolithic columns permanently coated with a long chained zwitterionic carboxybetaine-type surfactant is shown. The surfactant, N-dodecyl-N,N-(dimethylammonio)undecanoate (DDMAU), was used to coat 2.5, 5.0 and 10 cm long reversed-phase silica monoliths, resulting in a permanent zwitterionic exchange surface when used with aqueous based eluents. The unique structure of the surfactant results in a charge double layer structure on the surface of the stationary phase, with strong internal anionic and weak external cationic exchange groups. The dissociation of the weak external carboxylic acid group acts to shield the inner anionic exchange site, resulting in substantial effective capacity changes with eluent pH. Utilising this effect with the application of an eluent pH gradient, simultaneously combined with eluent flow-rate gradients, very rapid simultaneous separations of both weakly retained anions and strongly retained polarisable anions was possible, with up to 10-fold decreases in overall run times. Coating stability and retention times under isocratic and isofluentic eluent conditions were shown to be reproducible over >450 repeat injections, with peak efficiency values averaging 29,000 N/m for the 2.5 cm column and 42,000 N/m for the 10 cm monolithic column, again under isocratic elution conditions.  相似文献   

3.
Inorganic anions and cations in environmental waters were determined by ion chromatography. Stationary and mobile phases were examined for the simultaneous separation of both anions and cations. Cations detection by UV detection requires a mobile phase with a UV absorbing additive, which indirectly visualizes cations as negative peaks. Simultaneous separation of anions and cations were achieved when using an eluent that consists of inorganic acid with weak basic amino acid as additives. It was convenient to separate both anions and cations by coupling anion-exchange and cation-exchange columns in tandem. The order of the separation columns connected affected the elution profiles. When the eluent comprises of multiple anions and a single cation, the anion-exchange column should be connected in the upper stream, whereas when the eluent comprises multiple cations and a single anion, the cation-exchange column should be connected in the upper stream. Use of switching valves also allowed simultaneous separation of anions and cations in a single chromatographic run. In the present work, operating conditions were optimized for the simultaneous separation of anions and cations.  相似文献   

4.
Both particle packed (25 cm x 0.46 cm I.D. SUPELCOSIL 5 microm C18) and monolithic type (10 cm x 0.46 cm I.D. Merck Chromolith Performance C18) reversed-phase substrates were dynamically coated with a carboxybetaine type zwitterionic surfactant ((dodecyldimethyl-amino) acetic acid) and investigated as stationary phases for use in zwitterionic ion chromatography (ZIC). Investigations into eluent concentration and pH were carried out using KCl eluents containing 0.2 mM of the carboxybetaine surfactant to stabilise the column coatings. It was found that eluent concentration decreased anion retention whilst simultaneously increasing peak efficiencies, which may be due to the dissociation of intra- and inter-molecular salts of the carboxybetaine surfactant under higher ionic strength conditions. The Effect of eluent pH was an increase in anion retention with decreased eluent pH due to the increased protonation of the weak acid terminal group of the carboxybetaine, causing both a relative increase in the positive charge of the stationary phase and less repulsion of the anions by the dissociated weak acid group. The carboxybetaine-coated monolithic phase was applied to rapid anion separations using elevated flow rates and flow rate gradients.  相似文献   

5.
The retention and separation selectivity of inorganic anions and on-column derivatised negatively charged citrate or oxalate metal complexes on reversed-phase stationary phases dynamically coated with N-(dodecyl-N,N-dimethylammonio)undecanoate (DDMAU) has been investigated. The retention mechanism for the metal-citrate complexes was predominantly anion exchange, although the amphoteric/zwitterionic nature of the stationary phase coating undoubtedly also contributed to the unusual separation selectivity shown. A mixture of 10 inorganic anions and metal cations was achieved using a 20 cm monolithic DDMAU modified column and a 1 mM citrate eluent, pH 4.0, flow rate equal to 0.8 mL/min. Selectivity was found to be strongly pH dependent, allowing additional scope for manipulation of solute retention, and thus application to complex samples. This is illustrated with the analysis of an acidic mine drainage sample with a range of inorganic anions and transition metal cations, varying significantly in their concentrations levels.  相似文献   

6.
Yokoyama Y  Sawaguchi N  Sato H 《The Analyst》2001,126(7):989-994
A successive non-suppressed ion chromatography (IC) system for the determination of common cations (Na+, K+, Mg2+, Ca2+) and anions (Cl-, Br-, NO3-, SO4(2-)) was developed, using two separation columns and a single eluent. 5-Sulfoisophthalic acid eluent was very suitable for such separations with a commercially available cation-exchange column for the mono- and di-valent cations and with an ODS column coated with cetyltrimethylammonium for the anions. Both cations and anions were detected with conductimetrically high sensitivity without any suppressor. After injecting an aliquot of sample solution, the solvent front from the cation-exchange column, including most of the anionic species, was firstly accumulated into the additional 2 ml accumulation loop for 60 s, while the cation IC was performed. Subsequently, the accumulated fraction was introduced into the anion-exchange column and chromatographed. Relative standard deviations (RSDs) of retention times and conductimetric area responses for common cations were within 6% and within 4%, respectively. The linear relationships between molar concentration and detector response ranged from 0.01 to 1.00 mM with r2 of 0.9994 for Na+, 0.9992 for K+, 0.9993 for Mg2+, and 0.9988 for Ca2+. The successive anion IC through the accumulating process was also quantitative, with 95% recovery or over for each analyte. The linear ranges were between 0.01 and 1.00 mM with r2 of 0.9996 for Cl-, 0.9997 for Br-, 0.9993 for NO3-, and 0.9984 for SO4(2-). The method was applied to the determination of common cations and anions in several mineral waters and a hot spring water.  相似文献   

7.
The preparation and evaluation of zirconium-adsorbing silica gel (Zr-Silica) as an ion-exchange stationary phase in ion chromatography for inorganic anions and cations was carried out. The Zr-Silica was prepared by the reaction of silanol groups on the surface of the silica gel with zirconium butoxide (Zr(OCH2CH2CH2CH3)4) in ethanol. The ion-exchange characteristics of the Zr-Silica were evaluated using 10 mM tartaric acid at pH 2.5 as eluent. The Zr-Silica was found to act as a cation-exchanger under the eluent conditions. The retention behavior of alkali and alkaline earth metal cations was then investigated. The Zr-Silica column was proved to be suitable for the simultaneous separation of alkali metal cations and ammonium ion. Excellent separation of the cations on a 15 cm Zr-Silica column was achieved in 25 min using 10 mM tartaric acid as eluent.  相似文献   

8.
Influence of acidic eluent on retention behaviors of common anions and cations by ion-exclusion/cation-exchange chromatography (ion-exclusion/CEC) were investigated on a weakly acidic cation-exchange resin in the H(+)-form with conductivity. Sensitivities of analyte ions, especially weak acid anions (F(-) and HCOO(-)), were affected with degree of background conductivity level with pK(a1) (first dissociation constant) of acid in eluent. The retention behaviors of anions and cations were related to that of elution dip induced after eluting acid to separation column and injecting analyte sample. These results were largely dependent on the natures of acid as eluent. Through this study, succinic acid as the eluent was suitable for simultaneous separation of strong acid anions (SO(4)(2-), Cl(-), NO(3)(-) and I(-)), weak acid anions (F(-), HCOO(-) and CH(3)COO(-)), and cations (Na(+), K(+), NH(4)(+), Mg(2+) and Ca(2+)). The separation was achieved in 20 min under the optimum eluent condition, 20 mM succinic acid/2 mM 18-crown-6. Detection limits at S/N=3 ranged from 0.10 to 0.51 microM for strong acid anions, 0.20 to 5.04 microM for weak acid anions and 0.75 to 1.72 microM for cations. The relative standard deviations of peak areas in the repeated chromatographic runs (n=10) were in the range of 1.1-2.9% for anions and 1.8-4.5% for cations. This method was successfully applied to hot spring water containing strong acid anions, weak acid anions and cations, with satisfactory results.  相似文献   

9.
Separations of common inorganic anions were carried out on ODS columns coated with two long-chain alkylimidazolium ionic liquids ([C(12)MIm]Br and [C(14)MIm]Br) as new cationic surfactants for ion chromatography. With phthalate buffer solution as the mobile phases and non-suppressed conductivity detection, high column efficiencies and excellent selectivity were obtained in the separation of inorganic anions. Chromatographic parameters are calculated and the results show that the coated column possesses significant potential for the analysis of some inorganic anions such as CH(3)COO(-), IO(3)(-), Cl(-), BrO(3)(-), NO(2)(-), Br(-), NO(3)(-), SO(4)(2-), I(-), BF(4)(-), and SCN(-). The effect of eluent pH values on the separation of anions has been studied on the column coated with [C(12)MIm]Br. The stability of the coated columns was also examined.  相似文献   

10.
Muhammad Amin 《Talanta》2007,71(4):1470-1475
A convenient ion chromatography method has been proposed for the routine and simple determination of anions (Cl, SO42− and NO3) and/or cations (Na+, NH4+, K+, Mg2+ and Ca2+) using a single pump, a single eluent and a single detector. The present system used cation-exchange and anion-exchange columns connected in series via two 6-port switching valves or a single 10-port valve. The connection order of the ion-exchange columns could be varied by switching the valve(s). The present system therefore allowed the separation of either cations or anions in a single chromatographic run. While one ion-exchange column is being operated, the other ion-exchange column is being conditioned, i.e., the columns are always ready for analysis at any time. When 2.4 mM 5-sulfosalicylic acid was used as the eluent, the three anions and the five cations could be separated on the anion-exchange column and cation-exchange column, respectively. In order to obtain the separations of the target ions, the injection valve was placed between the two columns. Complete separations of the above anions or cations were demonstrated within 10 min each. The detection limits at S/N = 3 were 19-50 ppb (μg/l) for cations and 10-14 ppb for anions. The relative standard deviations of the analyte ions were less than 1.1, 2.9 and 2.8% for retention time, peak area and peak height, respectively. This proposed technique was applied to the determination of common anions and cations in river water samples.  相似文献   

11.
An ion chromatography method is described for the simultaneous determination of anions (Cl, NO3, and SO42–) and cations (Na+, NH4+, K+, Mg2+, and Ca2+) using a single pump, a single eluent and a single detector. An anion-exchange column modified with chondroitin sulfate C facilitated the elution of the above three anions using 5 mM tartaric acid as the eluent in isocratic mode, whereas the same eluent facilitated the separation of the above five cations on a commercially-available cation-exchange column. The separation columns were connected in series via two six-port switching valves, so the required cation-exchange or anion-exchange separation could be carried out by selecting the appropriate positions for the switching valves. The separations were completed in 30 min.  相似文献   

12.
A silica monolith column (Merck Chromolith, 100 mm x 4.6 mm) has been coated with Dionex AS9-SC latex nanoparticles to convert the column into an anion-exchange stationary phase. For comparison purposes, a reversed-phase silica monolith was also converted into an anion-exchange column by coating with the cationic surfactant didodecyldimethylammonium bromide (DDAB). Separations of common inorganic anions were carried out using 7.5 or 5.0 mM 4-hydroxybenzoic acid at pH 7.0 along with suppressed conductivity detection. Direct comparisons were then made between the two columns in terms of selectivity, efficiency and stability. The latex-coated column was on average 50% more efficient than the DDAB-coated column. A 10% decrease in retention times was observed on the DDAB column over 11 h of continuous eluent flow, while the latex coating exhibited <1% change in retention even after 2.5 months of periodic use.  相似文献   

13.
Fast ion-exchange chromatography has been developed and applied to the separation of common inorganic anions. Using a didodecyldimethylammonium bromide (DDAB) coated short (30 mm x 4.6 mm) ODS analytical column (3-microm particle size) and a 5 mM phthalate eluent (pH 7.5) the isocratic separation of nine common anions in 160 s was possible, with the first seven anions, including phosphate, chloride and sulphate, separated within 65 s. Detection was achieved using indirect UV at 279 nm. The high capacity, highly hydrophobic ion-exchange coating demonstrated excellent stability over time, even at elevated temperatures (45 degrees C) and exhibited unusual selectivity for common anions (retention order=fluoride, carbonate, phosphate, chloride, bromate, nitrite, sulphate, bromide and nitrate). The developed chromatography was successfully applied to the rapid analysis of river water and seawater samples.  相似文献   

14.
A method for the separation of acetate and formate anions by ion chromatography has been optimized under various measurement conditions (e.g. the composition of the mobile phase, and the flow rate of the eluent). For this purpose, two different analytical columns were examined: the IonPac AS14 (250 mm x 4 mm i.d.; designed mostly for the separation of inorganic anions) and the Allsep A-2 (150 mm x 4.6 mm i.d.; designed for the separation of low-molecular mass organic acids). However, nearly baseline separation of acetate and formate has been found on each column using the following conditions: (i) IonPac AS14 column and 2.0 mM Na2B4O7 solution as an eluent with a flow rate of 1.0 ml/min, or (ii) Allsep A-2 column and an eluent containing a mixture of 1.2 mM Na2CO3 plus 1.5 mM NaHCO3 with a flow rate of 1.3 ml/min. Additionally, the separation of fluoride from acetate and formate on both columns was studied. On the IonPac AS14 column it was possible to separate all three investigated anions. However, on the Allsep A-2 column, when the concentration of fluoride was comparable to, or higher than acetate, it was impossible to achieve good separation of these two anions, even using the optimized elution procedure. Therefore, the measurements of real samples were carried out with the use of IonPac AS14 column. The concentrations of acetate and formate have been determined in the air samples of the Cathedral of Cologne (Germany), after sampling the corresponding acids by passive diffusion tubes. Average concentrations of 122 and 9 microg/m(3) for acetic and formic acids were found, respectively, inside the Cathedral and in a depot with medieval stained glass panels.  相似文献   

15.
An ion chromatography (IC) method has been proposed for the determination of seven common inorganic anions (F(-), H(2)PO(4)(-), NO(2)(-), Cl(-), Br(-), NO(3)(-), and SO(4)(2-)) and/or five common inorganic cations (Na(+), NH(4)(+), K(+), Mg(2+), and Ca(2+)) using a single pump, a single eluent and a single detector. The present system used cation-exchange and anion-exchange columns connected in series via a single 10-port switching valve. The 10-port valve was switched for the separation of either cations or anions in a single chromatographic run. When 1.0mM trimellitic acid (pH 2.94) was used as the eluent, the seven anions and the five cations could be separated on the anion-exchange column and the cation-exchange column, respectively. The elution order was found to be F(-)相似文献   

16.
Novel CE methods have been developed on portable instrumentation adapted to accommodate a capacitively coupled contactless conductivity detector for the separation and sensitive detection of inorganic anions and cations in post‐blast explosive residues from homemade inorganic explosive devices. The methods presented combine sensitivity and speed of analysis for the wide range of inorganic ions used in this study. Separate methods were employed for the separation of anions and cations. The anion separation method utilised a low conductivity 70 mM Tris/70 mM CHES aqueous electrolyte (pH 8.6) with a 90 cm capillary coated with hexadimethrine bromide to reverse the EOF. Fifteen anions could be baseline separated in 7 min with detection limits in the range 27–240 μg/L. A selection of ten anions deemed most important in this application could be separated in 45 s on a shorter capillary (30.6 cm) using the same electrolyte. The cation separation method was performed on a 73 cm length of fused‐silica capillary using an electrolyte system composed of 10 mM histidine and 50 mM acetic acid, at pH 4.2. The addition of the complexants, 1 mM hydroxyisobutyric acid and 0.7 mM 18‐crown‐6 ether, enhanced selectivity and allowed the separation of eleven inorganic cations in under 7 min with detection limits in the range 31–240 μg/L. The developed methods were successfully field tested on post‐blast residues obtained from the controlled detonation of homemade explosive devices. Results were verified using ion chromatographic analyses of the same samples.  相似文献   

17.
Basic operation principles of a lightweight, low power, low cost, portable ion chromatograph utilizing open tubular ion chromatography in capillary columns coated with multi-layer polymeric stationary phases are demonstrated. A minimalistic configuration of a portable IC instrument was developed that does not require any chromatographic eluent delivery system, nor sample injection device as it uses gravity-based eluent flow and hydrodynamic sample injection adopted from capillary electrophoresis. As a detection device, an inexpensive commercially available capacitance sensor is used that has been shown to be a suitable substitute for contactless conductivity detection in capillary separation systems. The built-in temperature sensor allows for baseline drift correction typically encountered in conductivity/capacitance measurements without thermostating device. The whole instrument does not require any power supply for its operation, except the detection and data acquisition part that is provided by a USB port of a Netbook computer. It is extremely lightweight, its total weight including the Netbook computer is less than 2.5 kg and it can be continuously operated for more than 8 h. Several parameters of the instrument, such as detection cell design, eluent delivery systems and data treatment were optimized as well as the composition of eluent for non-suppressed ion chromatographic analysis of common inorganic cations (Na+, NH4+, K+, Cs+, Ca2+, Mg2+, transition metals). Low conductivity eluents based on weakly complexing organic acids such as tartaric, oxalic or pyridine-2,6-dicarboxylic acids were used with contactless capacitance detection for simultaneous separation of mono- and divalent cations. Separation of Na+ and NH4+ cations was optimized by addition of 18-crown-6 to the eluent. The best separation of 6 metal cations commonly present in various environmental samples was accomplished in less than 30 min using a 1.75 mM pyridine-2,6-dicarboxylic acid and 3 mM 18-crown-6 eluent with excellent repeatability (below 2%) and detection limits in the low micromolar range. The analysis of field samples is demonstrated; the concentrations of common inorganic cations in river water, mineral water and snow samples were determined.  相似文献   

18.
The unique ability of macrocyclic ligands, such as the crown ethers and cryptands, to selectively complex alkali metal cations can be used as the basis for chromatographic separations of anions. Specifically, macrocycles which are adsorbed onto a reversed-phase column, form positively charged anion-exchange sites when they combine with eluent cations. Previously we have demonstrated gradient anion separations based on changing the column capacity during the course of the separation by altering the eluent cation, temperature, or organic modifier content using cryptand-based columns. Herein we report that excellent separations can also be achieved using 18-crown-6 based columns. In this column, anion retention increases with increasing eluent strength and organic modifier content. This observation is in keeping with the relatively moderate affinity of crown ethers for alkali metals when compared to cryptands. The separation of anions achieved by optimizing mobile phase variables shows that isocratic separations of anions on the crown-based column are almost as good as separations achieved only under gradient conditions on cryptand-based columns. Cation gradients provide additional improvements on the separations using the crown-based column.  相似文献   

19.
Short reversed-phase columns (50 mm x 4.6 mm Gemini C(18)) were dynamically coated with carboxybetaines of the general structure, C(12)H(25)N(+)(CH(3))(2)(CH(2))(n)COOH, namely (N-dodecyl-N,N-dimethylammonio)undecanoate, DDMAU (n=10) and (N-dodecyl-N,N-dimethylammonio)butyrate, DDMAB (n=3), and investigated for the separation of inorganic anions in ion chromatography. The role of the ionic strength of coating surfactant solutions on their adsorption and resultant column capacity was studied. The retention of inorganic anions was investigated with different eluents at various concentrations and pH. Interestingly, no retention for anions was found with pure water as the eluent, but the addition of small amounts of electrolytes, up to 0.1 mM, caused a sharp increase in the retention of analytes. The effect of increasing anion retention with an increase in eluent cation charge was also observed. Based on this effect a new cation charge gradient concept was proposed and applied to the separation of a standard mixture of anions.  相似文献   

20.
建立了高氯、高钠油田回注水中痕量无机阴、阳离子和有机酸的离子色谱分析方法。对高钠基质中痕量阳离子的测定,选用IonPac CS12A分析柱、H2SO4溶液梯度淋洗、电导检测器检测;对高氯基质中阴离子及有机酸的测定,选用对OH-具有高选择性的高容量的IonPac AS11-HC柱、KOH梯度淋洗、电导检测器检测。在优化的梯度淋洗条件下,高氯或高钠的存在不影响痕量阴离子或阳离子的测定。该方法具有良好的线性(r=0.9926~0.9990)和精密度(测定组分峰面积的相对标准偏差(n=7)在8.0%以下),回收率  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号