首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 21 毫秒
1.
Ilaprazole is a new proton pump inhibitor designed for the treatment of gastric ulcers, and limited data is available on the metabolism of the drug. In this article, the structural elucidation of urinary metabolites of ilaprazole in human was described by HPLC‐ESI‐MS/MS and stopped‐flow HPLC‐NMR experiments. Urinary samples were precipitated by sodium carbonate solution, and then extracted by liquid–liquid extraction after adding ammonium acetate buffer solution. The enriched sample was separated using a C18 reversed‐phase column with the mobile phase composed of acetonitrile and 0.05 mol/L ammonium acetate buffer solution in a gradient solution, and then directly coupled to ESI‐MS/MS detection in an on‐line mode or 1H‐NMR (500 MHz) spectroscopic detection in a stopped‐flow mode. As a result, four sulfide metabolites, ilaprazole sulfide (M1), 12‐hydroxy‐ilaprazole sulfide (M2), 11,12‐dihydroxy‐ilaprazole sulfide (M3) and ilaprazole sulfide A (M4), were identified by comparing their MS/MS and NMR data with those of the parent drug and available standard compounds. The main biotransformation reactions of ilaprazole were reduction and the aromatic hydroxylation of the parent drug and its relative metabolites. The result testified that HPLC‐ESI‐MS/MS and HPLC‐NMR could be widely applied in detection and identification of novel metabolites. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
The employment of chemical weapons by rogue states and/or terrorist organizations is an ongoing concern in the United States. The quantitative analysis of nerve agents must be rapid and reliable for use in the private and public sectors. Current methods describe a tedious and time‐consuming derivatization for gas chromatography–mass spectrometry and liquid chromatography in tandem with mass spectrometry. Two solid‐phase extraction (SPE) techniques for the analysis of glyphosate and methylphosphonic acid are described with the utilization of isotopically enriched analytes for quantitation via atmospheric pressure chemical ionization–quadrupole time‐of‐flight mass spectrometry (APCI‐Q‐TOF‐MS) that does not require derivatization. Solid‐phase extraction‐isotope dilution mass spectrometry (SPE‐IDMS) involves pre‐equilibration of a naturally occurring sample with an isotopically enriched standard. The second extraction method, i‐Spike, involves loading an isotopically enriched standard onto the SPE column before the naturally occurring sample. The sample and the spike are then co‐eluted from the column enabling precise and accurate quantitation via IDMS. The SPE methods in conjunction with IDMS eliminate concerns of incomplete elution, matrix and sorbent effects, and MS drift. For accurate quantitation with IDMS, the isotopic contribution of all atoms in the target molecule must be statistically taken into account. This paper describes two newly developed sample preparation techniques for the analysis of nerve agent surrogates in drinking water as well as statistical probability analysis for proper molecular IDMS. The methods described in this paper demonstrate accurate molecular IDMS using APCI‐Q‐TOF‐MS with limits of quantitation as low as 0.400 mg/kg for glyphosate and 0.031 mg/kg for methylphosphonic acid. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
In order to have overall chemical material information of Kai‐Xin‐San (KXS), the reliable ultra‐high‐performance liquid chromatography quadrupole time‐of‐flight mass spectrometer (UHPLC–Q‐TOF‐MS) and ultra‐fast liquid chromatography mass spectrometer (UFLC‐MS/MS) methods were developed for the identification and determination of the major constituents in KXS. Moreover, the UHPLC–Q‐TOF‐MS method was also applied to screen for multiple absorbed components in rat plasma after oral administration of KXS. The UHPLC–Q‐TOF‐MS method was achieved on Agilent 6520 Q‐TOF mass and operated in the negative ion mode. Good separation was performed on a ZORBAX Eclipse Plus C18 column with a gradient elution at a flow rate of 0.2 ml/min. A total of 92 compounds in KXS were identified or tentatively characterized based on their exact molecular weights, fragmentation patterns, and literature data. A total of 26 compounds including 23 prototype components and three metabolites were identified in rat plasma after oral administration of KXS. Then, 16 major bioactive constituents were chosen as the benchmark substances to evaluate the quality of KXS. Their quantitative analyses were performed by a triple quadrupole tandem mass spectrometer (MS/MS) operating in multiple‐reaction monitoring mode(MRM). The analysis was completed with a gradient elution at a flow rate of 0.4 ml/min within 35 min. The simple and fast method was validated and showed good linearity, precision, and recovery. Furthermore, the method was successful applied for the determination of 16 compounds in KXS. All results would provide essential data for identification and quality control of active chemical constituents in KXS. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

4.
Capillary zone electrophoresis (CZE)–tandem mass spectrometry (MS/MS) has recently attracted attention as a tool for shotgun proteomics. However, its performance for this analysis has so far fallen far below that of reversed‐phase liquid chromatography (RPLC)–MS/MS. The use of a CZE method with a wide separation window (up to 90 min) and high peak capacity (ca. 300) is reported. This method was coupled to an Orbitrap Fusion mass spectrometer through an electrokinetically pumped sheath‐flow interface for the analysis of complex proteome digests. Single‐shot CZE–MS/MS lead to the identification of over 10 000 peptides and 2100 proteins from a HeLa cell proteome digest in approximately 100 min. This performance is nearly an order of magnitude better than earlier CZE studies and is within a factor of two to four of the state‐of‐the‐art nano ultrahigh‐pressure LC system.  相似文献   

5.
张素艳  耿昱  郭寅龙  王浩  吕龙 《中国化学》2005,23(7):870-874
High performance liquid chromatography (HPLC) and electrospray ionization mass spectrometry (ESI-MS) have been utilized to analyze the synthesized 2-(2-arylaminomethylphenoxy)pyrimidine derivatives, which are a new kind of environmentally benign herbicides and have passed the temporary pesticide registration. The identification of main product and impurities has been achieved according to the UV and mass spectra. Moreover, one impurity, introduced by the raw material in the last step of the synthetic route, was identified by GC-MS analysis. It can be concluded that the combination of chromatography and mass spectrometry, including LC-MS and GC-MS, provided a vital tool of the pesticide science.  相似文献   

6.
The use of chemical warfare agents has become an issue of emerging concern. One of the challenges in analytical monitoring of the extremely toxic ‘V’‐type chemical weapons [O‐alkyl S‐(2‐dialkylamino)ethyl alkylphosphonothiolates] is to distinguish and identify compounds of similar structure. MS analysis of these compounds reveals mostly fragment/product ions representing the amine‐containing residue. Hence, isomers or derivatives with the same amine residue exhibit similar mass spectral patterns in both classical EI/MS and electrospray ionization‐MS, leading to unavoidable ambiguity in the identification of the phosphonate moiety. A set of five ‘V’‐type agents, including O‐ethyl S‐(2‐diisopropylamino)ethyl methylphosphonothiolate (VX), O‐isobutyl S‐(2‐diethylamino)ethyl methylphosphonothiolate (RVX) and O‐ethyl S‐(2‐diethylamino)ethyl methylphosphonothiolate (VM) were studied by liquid chromatography/electrospray ionization/MS, utilizing a QTRAP mass detector. MS/MS enhanced product ion scans and multistage MS3 experiments were carried out. Based on the results, possible fragmentation pathways were proposed, and a method for the differentiation and identification of structural isomers and derivatives of ‘V’‐type chemical warfare agents was obtained. MS/MS enhanced product ion scans at various collision energies provided information‐rich spectra, although many of the product ions obtained were at low abundance. Employing MS3 experiments enhanced the selectivity for those low abundance product ions and provided spectra indicative of the different phosphonate groups. Study of the fragmentation pathways, revealing some less expected structures, was carried out and allowed the formulation of mechanistic rules and the determination of sets of ions typical of specific groups, for example, methylphosphonothiolates versus ethylphosphonothiolates. The new group‐specific ions elucidated in this work are also useful for screening unknown ‘V’‐type agents and related compounds, utilizing precursor ion scan experiments. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
A robust ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method for the determination of morphine‐6‐d ‐glucuronide (M6G), morphine‐3‐d ‐glucuronide (M3G) and morphine (MOR) in human plasma and urine has been developed and validated. The analytes of interest were extracted from plasma by protein precipitation. The urine sample was prepared by dilution. Both plasma and urine samples were chromatographed on an Acquity UPLC HSS T3 column using gradient elution. Detection was performed on a Xevo TQ‐S tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. Matrix interferences were not observed at the retention time of the analytes and internal standard, naloxone‐D5. The lower limits of quantitation of plasma and urine were 2/0.5/0.5 and 20/4/2 ng/mL for M6G/M3G/MOR, respectively. Calibration curves were linear over the concentration ranges of 2–2000/0.5–500/0.5–500 and 20–20,000/4–4000/2–2000 ng/mL for M6G/M3G/MOR in plasma and urine samples, respectively. The precision was <7.14% and the accuracy was within 85–115%. Furthermore, stability of the analytes at various conditions, dilution integrity, extraction recovery and matrix effect were assessed. Finally, this quantitative method was successfully applied to the pharmacokinetic study of M6G injection in Chinese noncancer pain patients.  相似文献   

8.
A thalidomide analog, (4‐(1,3‐dioxo‐1,3‐dihydro‐2H‐isoindol‐2‐yl)‐N ′‐[(4‐ethoxyphenyl) methylidene] benzohydrazide), has been identified as a promising broad‐spectrum anti‐inflammatory agent in previous study. In this study, a sensitive and selective UPLC‐MS/MS assay was developed and validated for its determination in rat plasma samples. The chromatographic separation was performed on an Aquity BEH C18 column using mobile phase comprising of acetonitrile and 10 mm ammonium acetate in the ratio of 85: 15, at flow rate of 0.3 mL/min. The detection and quantification were performed in positive multiple reaction monitoring mode by parent to daughter ion transition of 414.06 ˃ 148.05 for analyte and 411.18 ˃ 191.07 for internal standard (risperidone), respectively using electrospray ionization source. The sample extraction process consisted of liquid–liquid extraction method using diethyl ether as the extracting solvent. The assay was validated by following FDA guidelines and all parameters were found to be within acceptable limits. The linearity was between 10.1 and 2500 ng/mL and the lower limit of quantification was 10.1 ng/mL. The reported results indicate that the assay could meet the requirement for analysis of this compound in amounts expected to the present in actual samples. Further, in vitro metabolic stability study was performed in rat liver microsomes by using the validated assay.  相似文献   

9.
A new method based on pressurized liquid extraction followed by LC‐MS/MS analysis has been developed for the identification and quantification of three capsaicinoids (capsaicin, dihydrocapsaicin, and nordihydrocapsaicin) in extracts of Capsicum annuum. For the recovery of three capsaicinoids, the efficiency levels of ultrasonic‐assisted extraction, microwave‐assisted extraction, Soxhlet extraction, and pressurized liquid extraction were compared under different conditions. Pressurized liquid extraction resulted in higher yields. Pressurized liquid extractions were performed using methanol; temperature was set at 100°C and pressure at 1500 psi. LC analysis was performed on a Waters XBridge? C18 column (150 × 2.1 mm, id 3.5 μm) eluted by a mobile phase of 0.1% formic acid and ACN. Data acquisition was carried out in multiple reaction monitoring transitions mode, monitoring two‐reaction monitoring transitions to ensure an accurate identification of target compounds in the samples. The proposed method is rapid, simple, and could be utilized for the routine analysis of three capsaicinoids in C. annuum samples.  相似文献   

10.
A two‐dimensional (2D) hydrophilic interaction liquid chromatography (HILIC) and reverse‐phase (RP) liquid chromatography (LC) system coupled with triple‐quadrupole mass spectrometry (MS) was developed to comprehensively profile ceramides and phosphatidylcholine in extracted biological samples. Briefly, the 2D HILIC‐RPLC system used a silica HILIC column operated in the first dimension to distinguish the lipid classes and a BEH C18 column operated in the second dimension to separate the lipid species of the same class. The regression linearity of each lipid was satisfactory in both systems; however, the absolute matrix effect factor was reduced in 2D LC‐MS/MS system. Limits of detection of 2D LC‐MS/MS system were 2‐ to 3‐fold lower compared with one‐dimensional RPLC‐MS/MS. The recovery from the sample ranged from 84.5 to 110%. To summarize, the developed method was proven to be accurate and producible, as relative standard deviations remained <20% at three spiked levels. The efficiency of this newly developed system was applied to measure changes of lipids in the liver of mice after naphthalene treatment. Orthogonal projection to latent structures‐discriminant analysis discriminated the lipids from control and the treatment group. We concluded that 2D LC‐MS/MS is a promising method to assist lipidomic studies of complex biological samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
Isopropyl 3‐(3,4‐dihydroxyphenyl)‐2‐hydroxypropanoate (IDHP) is an investigational new drug having the capacity for treating ailments in the cardiovascular and cerebrovascular system. In this work, a rapid and sensitive method using high‐performance liquid chromatography coupled with electrospray ionization quadrupole time‐of‐flight tandem mass spectrometry (HPLC‐ESI‐Q‐TOF‐MS) was developed to reveal the metabolic profile of IDHP in rats after oral administration. The method involved pretreatment of the samples by formic acid–methanol solution (v/v, 5:95), chromatographic separation by an Agilent Eclipse XDB‐C18 column (150 × 4.6 mm i.dx., 5 μm) and online identification of the metabolites by Q‐TOF‐MS equipped with electrospray ionizer. A total of 16 metabolites from IDHP, including four phase I metabolites and 12 phase II metabolites, were detected and tentatively identified from rat plasma, urine and feces. Among these metabolites, Danshensu (DSS), a hydrolysis product of IDHP, could be further transformed to 11 metabolites. These results indicated that DSS was the main metabolite of IDHP in rats and the major metabolic pathways of IDHP in vivo were hydrolysis, O‐methylation, sulfation, glucuronidation and reduction. The results also demonstrated that renal route was the main pathway of IDHP clearance in rat. The present study provided valuable information for better understanding the efficacy and safety of IDHP. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
High‐performance liquid chromatography coupled with time‐of‐flight mass spectrometry (HPLC‐TOF/MS) and high‐performance liquid chromatography–triple quadrupole mass spectrometry (HPLC‐QQQ/MS/MS) were utilized to clarify the chemical constituents of Mahuang‐Fuzi‐Xixin Decoction. There are 52 compounds, including alkaloids, amino acids and organic acids were identified or tentatively characterized by their characteristic high resolution mass data by HPLC‐QQQ/MS/MS. In the subsequent quantitative analysis, 10 constituents, including methyl ephedrine, aconine, songrine, fuziline, neoline, talatisamine, chasmanine, benzoylmesaconine, benzoylaconine and benzoylhypaconine were simultaneously determined by HPLC‐QQQ/MS/MS with multiple reaction monitoring mode. Satisfactory linearity was achieved with wide linear range and fine determination coefficient (r > 0.9992). The relative standard deviations (RSD) of inter‐ and intra‐day precisions were <3%. This method was also validated by repeatability, stability and recovery with RSD <3% respectively. A highly sensitive and efficient method was established for chemical constituents studying, including identification and quantification of Mahuang‐Fuzi‐Xixin decoction.  相似文献   

13.
Structural modification of a polypeptide hormone, glucagon, by a hydroxyl radical in vitro was investigated by reversed‐phase high‐performance liquid chromatography (RP‐HPLC), and the oxidized site of glucagon was detected by electrospray ionization tandem mass spectrometry (ESI‐MS/MS). It was shown that 27methionine (Met) was oxidized to 27Met sulfoxide by hydroxyl radical, and the production rate of 27Met sulfoxide was faster than that by hydrogen peroxide. In addition, production of 27Met sulfoxide enantiomer was confirmed by RP‐HPLC analysis. cAMP production in a HepG2 cell induced by 27Met sulfoxide glucagon was reduced to approximately 75% as compared with that induced by the native form of glucagon. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Benzofurazan derivatization reagents, 4‐[2‐(N,N‐dimethylamino)ethylaminosulfonyl]‐7‐(2‐aminopentylamino)‐2,1,3‐benzoxadiazole (DAABD‐AP) and 4‐[2‐(N,N‐dimethylamino) ethylaminosulfonyl]‐7‐(2‐aminobutylamino)‐2,1,3‐benzoxadiazole (DAABD‐AB), for short‐chain carboxylic acids in liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) were synthesized. These reagents reacted with short chain carboxylic acids in the presence of the condensation reagents at 60°C for 60 min. The generated derivatives were separated on the reversed‐phase column and detected by ESI‐MS/MS with the detection limits of 0.1–0.12 pmol on column. Upon collision‐induced dissociation, a single and intense product ion at m/z 151 was observed. These results indicated that DAABD‐AP and DAABD‐AB are suitable as the derivatization reagents in LC/ESI‐MS/MS analysis. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

15.
A highly sensitive and selective on‐line two‐dimensional reversed‐phase liquid chromatography/electrospray ionization–tandem mass spectrometry (2D‐LC‐ESI/MS/MS) method was developed and validated to determine rifaximin in rat serum by direct injection. The 2D‐LC‐ESI/MS/MS system consisted of a restricted access media column for trapping proteins as the first dimension and a Waters C18 column as second dimension using 0.1% aqueous acetic acid:acetonitrile as mobile phase in a gradient elution mode. Rifampacin was used as an internal standard. The linear dynamic range was 0.5–10 ng/mL (r2 > 0.998). Acceptable precision and accuracy were obtained over the calibration range. The assay was successfully used in analysis of rat serum to support pharmacokinetic studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
A qualitative and quantitative analytical method was developed for the simultaneous determination of Δ9‐tetrahydrocannabinol (THC), 11‐hydroxy‐Δ9‐tetrahydrocannabinol (11‐OH‐THC) and l1‐nor‐9‐carboxy‐Δ9‐tetrahydrocannabinol (THC‐COOH) in whole blood. The samples were prepared by solid‐phase extraction followed by ultra‐performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) analysis using positive ion electrospray ionization and multiple reaction monitoring. The chromatographic separation was performed with an Acquity UPLC® HSS T3 (50 × 2.1 mm i.d., 1.8 µm) reversed‐phase column using a methanol/2 mM ammonium formate (formic acid 0.1%) gradient in a total run time of 9.5 min. MS/MS detection was achieved with two precursor‐product ion transitions per substance. The method was fully validated, including selectivity and capacity of identification, according to the identification criteria (two transitions per substance, signal‐to‐noise ratio, relative retention time and ion ratio) without the presence of interferences, limit of detection (0.2 µg/L for THC and 0.5 µg/L for 11‐OH‐THC and THC‐COOH), limit of quantitation (0.5 µg/L for all cannabinoids), recovery (53–115%), carryover, matrix effect (34‐43%), linearity (0.5‐100 µg/L), intra‐assay precision (CV < 10% for the relative peak area ratios and <0.1% for the relative retention time), inter‐assay accuracy (mean relative error <10%) and precision (CV <11%). The method has already been successfully used in proficiency tests and subsequently applied to authentic samples in routine forensic analysis. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
Pharmaceuticals require careful and precise determination of their impurities that might harm the user upon consumption. Although today, the most common technique for impurities identification is liquid chromatography‐mass spectrometry (LC‐MS/MS), it has several downsides due to the nature of the ionization method. Also, the analyses in many cases are targeted thus despite being present, some of the compounds will not be revealed. In this paper, we propose and show a new method for untargeted analysis and identification of impurities in active pharmaceutical ingredients (APIs). The instrument used for these analyses is a novel electron ionization (EI) LC‐MS with supersonic molecular beams (SMB). The EI‐LC‐MS‐SMB was implemented for analyses of several drug samples spiked with an impurity. The instrument provides EI mass spectra with enhanced molecular ions, named Cold EI, which increases the identification probabilities when the compound is identified with the aid of an EI library like National Institute of Standards and Technology (NIST). We analyzed ibuprofen and its impurities, and both the API and the expected impurity were identified with names and structures by the NIST library. Moreover, other unexpected impurities were found and identified proving the ability of the EI‐LC‐MS‐SMB system for truly untargeted analysis. The results show a broad dynamic range of four orders of magnitude at the same run with a signal‐to‐noise ratio of over 10 000 for the API and almost uniform response.  相似文献   

18.
An LC‐MS/MS method for the simultaneous quantitation of niacin (NA) and its metabolites, i.e. nicotinamide (NAM), nicotinuric acid (NUA) and N‐methyl‐2‐pyridone‐5‐carboxamide (2‐Pyr), in human plasma (1 mL) was developed and validated using nevirapine as an internal standard (IS). Extraction of the NA and its metabolites along with the IS from human plasma was accomplished using a simple liquid–liquid extraction. The chromatographic separation of NA, NAM, NUA, 2‐Pyr and IS was achieved on a Hypersil‐BDS column (150 ¥ 4.6 mm, 5 mm) column using a mobile phase consisting of 0.1% formic acid : acetonitrile (20:80 v/v) at a flow rate of 1 mL/min. The total run time of analysis was 2 min and elution of NA, NAM, NUA, 2‐Pyr and IS occurred at 1.37, 1.46, 1.40, 1.06 and 1.27 min, respectively. A detailed validation of the method was performed as per the FDA guidelines and the standard curves were found to be linear in the range of 100–20000 ng/mL for NA; 10–1600 ng/mL for NUA and NAM and 50–5000 ng/mL for 2‐Pyr with mean correlation coefficient of ≥0.99 for each analyte. The method was sensitive, specific, precise, accurate and suitable for bioequivalence and pharmacokinetic studies. The developed assay method was successfully applied to a pharmacokinetic study in humans. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
Atenolol, nadolol, metoprolol, bisoprolol and betaxolol were simultaneously determined in groundwater samples by large‐volume injection coupled‐column reversed‐phase liquid chromatography with fluorescence detection (LVI‐LC‐LC‐FD) and liquid chromatography‐time‐of‐flight mass spectrometry (LC‐TOF‐MS). The LVI‐LC‐LC‐FD method combines analyte isolation, preconcentration and determination into a single step. Significant reductions in costs for sample pre‐treatment (solvent and solid phases for clean up) and method development times are also achieved. Using LC‐TOF‐MS, accurate mass measurements within 3 ppm error were obtained for all of the β‐blockers studied. Empirical formula information can be obtained by this method, allowing the unequivocal identification of the target compounds in the samples. To increase the sensitivity, a solid‐phase extraction step with Oasis MCX cartridge was carried out yielding recoveries of 79–114% (n=5) with RSD 2–7% for the LC‐TOF‐MS method. SPE gives a high purification of β‐blockers compared with the existing methods. A 100% methanol wash was allowed for these compounds with no loss of analytes. Limit of quantification was 1–7 ng/L for LVI‐LC‐LC‐FD and 0.25–5 ng/L for LC‐TOF‐MS. As a result of selective extraction and effective removal of coextractives, no matrix effect was observed in LVI‐LC‐LC‐FD and LC‐TOF‐MS analyses. The methods were applied to detect and quantify β‐blockers in groundwater samples of Almería (Spain).  相似文献   

20.
A liquid chromatography–triple quadrupole mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of 5‐nitro‐5′‐hydroxy‐indirubin‐3′‐oxime (AGM‐130) in human plasma to support a microdose clinical trial. The method consisted of a liquid–liquid extraction for sample preparation and LC‐MS/MS analysis in the positive ion mode using TurboIonSprayTM for analysis. d3‐AGM‐130 was used as the internal standard. A linear regression (weighted 1/concentration) was used to fit calibration curves over the concentration range of 10–2000 pg/mL for AGM‐130. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 96.6% with a precision (coefficient of variation, CV) of 4.4%. For quality control samples at 30, 160 and 1600 pg/mL, the between run CV was ≤5.0 %. Between‐run accuracy ranged from 98.1 to 101.0%. AGM‐130 was stable in 50% acetonitrile for 168 h at 4°C and 6 h at room temperature. AGM‐130 was also stable in human plasma at room temperature for 6 h and through three freeze–thaw cycles. The variability of selected samples for the incurred sample reanalysis was ≤12.7% when compared with the original sample concentrations. This validated LC‐MS/MS method for determination of AGM‐130 was used to support a phase 0 microdose clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号