首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The present work suggests an alternative experimental method in order to not only measure the signal of the deep traps in Al2O3:C without heating the sample to temperatures greater than 500 °C, but also use this signal for high dose level dosimetry purposes as well. This method consists of photo transfer OSL measurements performed at elevated temperatures using the blue LEDs (470 nm, FWHM 20 nm) housed at commercial Risø TL/OSL systems, after the sample was previously heated up to 500 °C in order to empty its main TL dosimetric trap. The influence of this procedure on specific features such as glow curve shape and sensitivity of the main TL glow peak was also studied.  相似文献   

2.
The LM–OSL signal of quartz, while measured at room temperature, is dominated by an intermediate, broad and intense OSL component, so that its contribution and general characteristics are derived very accurately. Through a series of dose–response, bleaching and thermal decay at room temperature experiments, in conjunction with curve fitting studies, a component resolved analysis is carried out studying the correlation between this specific component, termed as LM–OSL component C2 and the 110 °C TL glow peak in quartz. The dose–response of these two luminescence components behaves exactly similar being linear at low doses and saturating at almost 100 Gy. Both signals decay exponentially under illumination, providing identical optical detrapping cross-section values. Residual of both luminescence signals after thermal decay at room temperature follows an exponential law, yielding similar mean half-lives. All previous luminescence features provide strong evidence for the electron trap being the same for both the 110 °C TL trap and the LM–OSL component C2. The results of the present work are very promising and clearly support the possibility of extrapolating the TL pre-dose methodology to the OSL pre-dose effect using only the LM–OSL component C2.  相似文献   

3.
《Radiation measurements》2009,44(3):232-238
A flow-through Geiger-Müller pancake electron detector attachment has been fitted to a standard Risø TL/OSL reader enabling optically stimulated electrons (OSE) to be measured simultaneously with optically stimulated luminescence (OSL). Using this detector, OSE and OSL measurements from natural quartz samples are studied to examine the possible use of OSE as a chronometer. First the relative variability in OSE and OSL growth curve shapes and the effect of preheat on these are presented, and from these curves, conclusions are drawn concerning the charge movement in natural quartz. Secondly, a dose recovery test shows that OSE can successfully recover a laboratory dose of 300 Gy given before any laboratory thermal treatment, for preheating temperatures between 160 and 260 °C. Furthermore, for the first time natural OSE decay curves are detected and these signals are used to estimate a burial dose using the single-aliquot regenerative-dose (SAR) procedure. Finally, a comparative study of the equivalent doses estimated using both OSE and OSL from 10 quartz samples are presented, and it is shown that OSE has a significant potential in retrospective dosimetry.  相似文献   

4.
《Radiation measurements》2007,42(2):190-197
An optically stimulated luminescence (OSL) age obtained from a Japanese tephra using quartz phenocrysts severely underestimated the known age. The characteristics of the OSL signals were investigated in order to understand the cause of the underestimation; the main OSL component of volcanic quartz has a thermodynamic lifetime of about 1700 years at room temperature, and it also seems to fade anomalously (i.e. athermally). Measurement of conventional red thermoluminescence (RTL) using a Ga–As photomultiplier tube was difficult due to the presence of a strong thermal background, although RTL gave an age consistent with the independent age. Furthermore, red isothermal TL (RITL) at 380 °C allowed the RTL signal to be separated from to the thermal background, and RITL ages of three volcanic quartz samples show good agreement with independent ages.  相似文献   

5.
International recommendations establish that 90Sr + 90Y clinical applicators have to be calibrated in order to determine the absorbed dose rates in the case of the sources that do not have original calibration certificates, or to update the absorbed dose rates presented in the source certificates. Following these recommendations, a postal dosimetric system was developed to calibrate clinical applicators using two luminescent techniques: thermoluminescence (TL) and optically stimulated luminescence (OSL). In this work, Al2O3:C commercial detectors were characterized and their TL and OSL responses were analyzed. The results showed the efficiency and the optimal behavior of this material in beta radiation beams. After characterization, the system was sent to the Federal University of Sergipe (UFS), Brazil, for calibration of five 90Sr + 90Y clinical applicators, where the detectors were irradiated and returned to IPEN, for their evaluation and determination of the absorbed dose rates. A comparison between these absorbed dose rates and those adopted by the UFS as original was made; the differences obtained were within those of other studies, and they demonstrated the usefulness of the system.  相似文献   

6.
The possibility of using different materials for thermoluminescent dosimetry agglutinating their powder with Teflon® (a polymer) has been studied in recent years. In this paper the thermoluminescent properties of spodumene-Teflon® composites were studied exposing them to different doses of a 60Co radiation source, in comparison to the thermoluminescent properties of crystalline powder and of Teflon. The thermoluminescent emission curve of pure Teflon® pellets showed two peaks at 200 and 250 °C at doses above 1 kGy, which may influence the dosimetry of high-doses that uses crystals agglutinated with this polymer. Preliminary results show that the Teflon® causes an increased sensitivity in the TL signal of the pellet compared to the crystalline powder without the polymer, and that even the pure Teflon® pellet is a material that can be exploited for high-doses dosimetry.  相似文献   

7.
Optically stimulated luminescence (OSL) measurements of quartz are widely used to measure equivalent dose (De). At radiation doses above ~100 Gy, saturation of traps results in a decrease in the rate of growth of the OSL signal, and this makes calculation of De increasingly difficult. A series of dose recovery experiments was undertaken using single grains of quartz from Kalambo Falls, Zambia to explore saturation of single grains. When the OSL signal from many grains is averaged, the characteristic dose (D0) is 47 Gy, typical of published values for quartz. However, D0 for individual grains varies from ~10 to 100 Gy. Doses up to two times the average D0 could be accurately recovered, but above this dose the De became increasingly underestimated. Overdispersion for this type of experiment should be zero, but was observed in all data sets; furthermore the value of overdispersion increased with De. An additional acceptance criterion, the Fast Ratio, is suggested for single grain OSL analysis. This criterion assesses the relative contribution of the fast component of the OSL signal. Including this as an additional acceptance criterion leads to an improved precision, with overdispersion reduced to zero, and improved accuracy in dose recovery at high doses.  相似文献   

8.
The fast, linearly modulated optically stimulated luminescence (LM-OSL) component in quartz is the main dosimetric signal used for the dating applications of this material. Since the blue light stimulation (470 nm, 40 mW cm ?2) time needed to obtain the fast LM-OSL component is less than 50 s the electron trapping levels responsible for it are still highly populated. In this way an active radiation history is created which could play an important role in the dosimetric characteristics of the fast OSL signal. In the present work the dose response behavior of the fast OSL signal is investigated in quartz samples with an annealed radiation history and quartz samples possessing an artificial radiation history. A computerized curve de-convolution analysis of the LM-OSL curves for 50 s stimulation time showed that it consists of three individual OSL components. The faster component C1 with peak maximum time around 5 s has a linear dose response in virgin samples, which turns to a slight superlinearity as a function of the artificial radiation history. On the other hand the component C2 with peak maximum time at 12 s is slightly superlinear which turns into strong superlinearity as a function of artificial radiation history. Finally, component C3 with peak maximum time at about 45 s is strongly superlinear for both virgin samples and as a function of artificial radiation history. The implications to practical application are discussed.  相似文献   

9.
Pulsed OSL is applied to nine fine-grained sediment samples from Sichuan province, China, using stimulating pulses of 10 μs on and 240 μs off, with an infrared exposure prior to each OSL measurement. Comparison of fading rates between pulsed and non-pulsed signals, the latter also obtained with a preceding IR exposure, shows that fading is significant for mainly the non-pulsed signals. Presence of a pulsed IRSL and the magnitudes of b-value to correct for lower alpha efficiency suggest that pulsing does not fully remove a significant feldspar signal, only a fading component. Comparison with ages of quartz extracts shows that pulsed OSL ages are consistent, while CW-OSL ages are slightly older and CW-IRSL ages are much older. The older ages suggest a less well-bleached feldspar component.  相似文献   

10.
Topaz shows thermoluminescence (TL) on heating after exposure to ionising radiation. A study was carried out to explore the possibility to design and develop a TLD (thermoluminescence dosimeter) from locally occurring topaz. Topaz was collected from a mine in Yono Shigar valley in northern Pakistan. The samples were identified as topaz by neutron irradiation, X-ray diffraction and X-ray fluorescence. The crystals of topaz were cut into chips of dimensions compatible to the commercial TLD readers. The chips were exposed to 60Co and/or 137Cs gamma irradiators. The investigation features included glow curve, dose and energy responses, sensitivity, fading, reproducibility and mechanical stability. The TL glow curves revealed a stable peak at about 250 °C, whose height rose linearly with increase of irradiation dose. The TL response versus dose (calibration curve) showed the linear behaviour between 10?2 and 102 Gy. The dose response was independent of gamma energies of 60Co and 137Cs. The response of topaz chips remained constant within 10% deviation from the initial value after 30 cycles of reuse. The rate of fading of topaz was very fast just after irradiation and slowed after a few days. Mechanical stability of the chips remained constant during handling in all investigation experiments. The topaz from Yono Shigar mine may be recommended as a TLD for gamma dose within 10?2–102 Gy.  相似文献   

11.
The following varieties of natural quartz, as the blue, the green, the red, the pink, the black, the sulphurous and the milky quartz, have been investigated concerning their thermoluminescence properties. For comparison sake natural colorless alpha quartz has been include. Since X-rays diffraction analysis has shown that all of them have the same crystal structure as the alpha quartz, it is expected that no great change in the TL property should be found, however, that was not the case. The TL peaks at 110, 175, 220, 325 and 375 °C observed in the alpha quartz are not found in all the varieties of quartz, for instance, the sulphurous quartz presented only 110° and 245° peaks, the pink one presented just 110, 220 and 375 °C peaks and so on. In respect to TL response as function of gamma ray dose a quite varied behavior has been observed and discussed.  相似文献   

12.
《Radiation measurements》2009,44(2):149-157
In this study, we applied optically stimulated luminescence (OSL) dating to two fine grain sediment samples collected at Jeongokri, Korea. A single aliquot regenerative dose (SAR) procedure was applied to both polymineral grains and to chemically isolated (H2SiF6) quartz grains of 4–11 μm diameter. For polymineral fine grains, the OSL IR depletion ratio and the equivalent dose (De) plateau test appear to be equally sensitive indicators of appropriate IR stimulation time for use in the ‘double SAR’ protocol. Additionally, the OSL IR depletion ratio test gives an indication of the relative mineral composition of the samples, hence providing an assessment of the likelihood of obtaining a quartz-dominated [post-IR] OSL signal. Use of higher preheat temperatures would assist in thermally eroding the non-quartz component of the [post-IR] OSL signal from polyminerals. For the quartz fine grains, data from both natural De determinations and laboratory dose recovery tests are required to identify the appropriate preheat temperatures for dating, due to problems of thermal transfer. This phenomenon is particularly exaggerated for these samples due to the large De values (≥350 Gy) and hence low slope of the dose–response curve. The double SAR method cannot be applied ubiquitously, even after careful and rigorous study of one sample from a section. Quartz OSL dating using a range of preheat temperatures is suggested to be the most suitable method for OSL dating of fine grain sediments.  相似文献   

13.
14.
The feasibility of utilizing the pre-dosed OSL signal in the estimation of the equivalent dose has been investigated. The results based on (i) the behavior of growth curve, (ii) dose recovery tests and (iii) non-bleachability of reservoir centres, R-centres, suggests that (i) the pre-dosed OSL does not seem to work satisfactorily in dose estimation unlike the pre-dosed 110 °C TL emission and (ii) it may not be applicable in case of bleached specimen.  相似文献   

15.
Laboratory storage and preheating experiments were carried out to study anomalous fading of infrared stimulated luminescence (IRSL) signals derived from polymineral grains extracted from Chinese loess. Results of laboratory storage at 150 °C and higher temperature preheating experiments showed that such thermal treatments could lessen the effect of fading and indicated the presence of both thermal and non-thermal fading. In addition, the behavior of natural fading over the past 9–170 ka was investigated. By comparing with independent ages (obtained from fine-grain quartz using the optically stimulated luminescence (OSL) signal for the past 130 ka and the thermally transferred OSL (TT-OSL) signal in the age range of 130–170 ka) for the same samples, equivalent doses obtained from the IRSL signals were found to be underestimated by different amounts since the penultimate glacial; there was a linear dependence when the age underestimation was plotted against geological time.  相似文献   

16.
The aim of this paper is to evaluate the thermoluminescent (TL) response of a larimar, a variety of pectolite (NaCa2Si3O8[OH]). It is a blue pectolite only found on the terrestrial crust of the province of Barahona, in the south-western region of the Dominican Republic. The larimar rock used in this study, presented a light-blue color with brown areas. X-ray powder diffractometry (XRD), showed that the light-blue portion of the rock is composed essentially by pectolite and the brown portion is composed by a mixture of minerals. Aliquots of 5 mg of light-blue portions were irradiated with gamma rays with doses from 10 to 104 Gy and the TL glow curves were obtained from 50 to 400 °C. The glow curve showed a broad peak around 150 °C and a peak near 280 °C. Different pre-heat condition were used to remove the broad peak. The TL emission of the main peak appeared in the region of 580 nm. The TL response of the main peak showed a linear behavior up to 2500 Gy and a sub-linear behavior above this dose value. Studies of the 30 day fading effects in TL signal using a pre-heating temperature around 180 °C during 15 min were carried out and fading near 25% was observed.  相似文献   

17.
《Radiation measurements》2007,42(2):144-155
The structure of the linearly modulated optically stimulated luminescence (LM-OSL) signal was studied for four sedimentary quartz samples, collected from different sites around Istanbul, Turkey. Applying a computerized deconvolution analysis to the LM-OSL curves, at least six individual components of first-order kinetics were identified and photoionization cross-section of each component was evaluated. The OSL dose–response curve of each component for each quartz sample was obtained, showing a remarkable differentiation from component to component. The behavior of a highly dosed sample to successive LM-OSL measurements was also studied showing a stable recuperation signal in the position of the “slow” and “medium” components and high resistance to OSL bleaching of the “slow” component. The individual sensitivity of each component as a function of the activation temperature was obtained. The sensitivity of each component was normalized over the respective sensitivity of the glow-peak at 110 °C of quartz in order to investigate the ability of the 110 °C glow-peak to act as a correction factor for all components of the LM-OSL curves examined.  相似文献   

18.
Optically Stimulated Luminescence (OSL) signals of BeO ceramics were investigated using continuous wave (CW) OSL and Linearly Modulated (LM) OSL. It was found that both curves can be approximated using a linear combination of two first-order components. Experiments on the measurement temperature dependence have shown that these two components have nearly the same thermal quenching energies around 0.57 eV. Dependences of the OSL signal on preheat temperature and radiation dose were also examined. Thermal annealing experiments have shown that OSL signals originate from traps which are unstable near 340 °C, thus proving the suitability of the signals for dosimetric purposes. Dose response was found to be linear and a minimum detectable dose of ~10 μGy was found.  相似文献   

19.
Thermoluminescence (TL) measurements were carried out on undoped and Mn2+ doped (0.1 mol%) yttrium aluminate (YAlO3) nanopowders using gamma irradiation in the dose range 1–5 kGy. These phosphors have been prepared at furnace temperatures as low as 400 °C by using the combustion route. Powder X-ray diffraction confirms the orthorhombic phase. SEM micrographs show that the powders are spherical in shape, porous with fused state and the size of the particles appeared to be in the range 50–150 nm. Electron Paramagnetic Resonance (EPR) studies reveal that Mn ions occupy the yttrium site and the valency of manganese remains as Mn2+. The photoluminescence spectrum shows a typical orange-to-red emission at 595 nm and suggests that Mn2+ ions are in strong crystalline environment. It is observed that TL intensity increases with gamma dose in both undoped and Mn doped samples. Four shouldered TL peaks at 126, 240, 288 and 350 °C along with relatively resolved glow peak at 180 °C were observed in undoped sample. However, the Mn doped samples show a shouldered peak at 115 °C along with two well defined peaks at ~215 and 275 °C. It is observed that TL glow peaks were shifted in Mn doped samples. The kinetic parameters namely activation energy (E), order of kinetics (b), frequency factor (s) of undoped, and Mn doped samples were determined at different gamma doses using the Chens glow peak shape method and the results are discussed in detail.  相似文献   

20.
The effect of fast neutron fluencies and γ-rays on the DC conductivity, ln(σ), for pure gelatin and that doped with 5, 10, and 15 wt% of CoCl2 · 6H2O, and 5 wt% of NiCl2 · 6H2O, MnCl2 · 2H2O and AgNO3 has been respectively investigated at different temperatures. Fast neutron fluencies and γ-rays doses are set from 7.60 × 105 to 0.50 × 109 N/cm2, and 0.25 up to 1.50 Gy, respectively. The calculated values of activation energies (Ea) are found to be dependent on the radiation doses. The conductivity of gelatin samples shows an interesting behavior, which depends on the dopant Co concentration and the exposure dose. DC conductivity of the investigated samples reveals that the ionic conduction has been established at higher temperatures and fast neutron fluencies and γ-rays doses, while the electronic one plays an important role at lower temperatures. This has been related to the crosslinking formations as a result of the interaction between the exposure dose and gelatin sample. The attained results suggest strongly the applicability of these materials in dosimetry.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号