首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Pulsed OSL is applied to nine fine-grained sediment samples from Sichuan province, China, using stimulating pulses of 10 μs on and 240 μs off, with an infrared exposure prior to each OSL measurement. Comparison of fading rates between pulsed and non-pulsed signals, the latter also obtained with a preceding IR exposure, shows that fading is significant for mainly the non-pulsed signals. Presence of a pulsed IRSL and the magnitudes of b-value to correct for lower alpha efficiency suggest that pulsing does not fully remove a significant feldspar signal, only a fading component. Comparison with ages of quartz extracts shows that pulsed OSL ages are consistent, while CW-OSL ages are slightly older and CW-IRSL ages are much older. The older ages suggest a less well-bleached feldspar component.  相似文献   

2.
In the past, time-resolved IR stimulated luminescence (TR-IRSL) curves from feldspar have mainly been measured over a few hundred μs with the purpose of estimating the lifetimes of the components. In this study, we present the decay form of time-resolved IRSL and IR stimulated phosphorescence (IRSP) from orthoclase feldspar covering over 8 orders of magnitude (50 ns to ~7 s). A detailed characterisation of the slowly decaying signals (ms to s time scales) from feldspar is undertaken to obtain further insight into the role of re-trapping in both the IR stimulated luminescence (IRSL) and the relatively more stable post-IR IRSL signals. The decay form of the different signals examined here shows a weak dependence on preheat temperature and a strong dependence on stimulation temperature. Interestingly, the IRSP curves show a conspicuous kink of which the position is linearly dependent on the on-time duration.The data on thermal dependence of these signals might suggest that the decay behaviour of the time-resolved IRSL and phosphorescence signals mainly reflect the occupancy of electrons in the band tail states with a significant contribution from the shallow traps. This interpretation is supported by thermoluminescence (TL) curves showing the photo-transfer effect during short IR and post-IR IR stimulations.  相似文献   

3.
《Radiation measurements》2009,44(3):232-238
A flow-through Geiger-Müller pancake electron detector attachment has been fitted to a standard Risø TL/OSL reader enabling optically stimulated electrons (OSE) to be measured simultaneously with optically stimulated luminescence (OSL). Using this detector, OSE and OSL measurements from natural quartz samples are studied to examine the possible use of OSE as a chronometer. First the relative variability in OSE and OSL growth curve shapes and the effect of preheat on these are presented, and from these curves, conclusions are drawn concerning the charge movement in natural quartz. Secondly, a dose recovery test shows that OSE can successfully recover a laboratory dose of 300 Gy given before any laboratory thermal treatment, for preheating temperatures between 160 and 260 °C. Furthermore, for the first time natural OSE decay curves are detected and these signals are used to estimate a burial dose using the single-aliquot regenerative-dose (SAR) procedure. Finally, a comparative study of the equivalent doses estimated using both OSE and OSL from 10 quartz samples are presented, and it is shown that OSE has a significant potential in retrospective dosimetry.  相似文献   

4.
Quartz extracted from heated bricks has been previously suggested for use in dose estimation in accident dosimetry, but this technique has never been applied before to Japanese quartz which often has unusual OSL characteristics. In this study the optically stimulated luminescence (OSL) characteristics of quartz extracted from a Japanese commercial red brick produced by Mishima – Renga – Seizoujyo Co. are studied. These companies are based in the Aichi Prefecture (capital Nagoya), which accounts for about half of the red brick production in Japan. A comparison of TL (thermoluminescence) and OSL signals has been carried out towards identification of common source traps. It is observed that OSL from Japanese brick quartz shows unusual luminescence characteristics; in particular, the initial fast decaying OSL signal contains a dominant (>90%) thermally unstable component related to the 85 °C TL peak, which necessitates a prior heat treatment. A single-aliquot regenerative-dose (SAR) protocol is developed and tested using thermal treatments intended to isolate a stable dosimetric signal. A minimum detection limit of ~65 mGy is then estimated using this protocol. Following irradiation using 60Co and 137Cs, dose–depth profiles were measured on two different commercial brick types (Mishima – Renga – Seizoujyo Co. and Hase – Renga Co.) with 5 Gy and 10 Gy surface doses. The profiles derived from the two sources were readily distinguishable. It is concluded that the OSL signals from the two types of Japanese brick quartz examined here can be used to derive precise estimates of accident dose, and, possibly to distinguish between sources of gamma radiation in a nuclear accident.To our knowledge, this is the first report on the existence of an unstable fast decaying OSL signal in quartz derived from bricks, and demonstrates a way forward with such samples in retrospective dosimetry.  相似文献   

5.
The post-IR IRSL protocol with single K-feldspar grains was applied to three samples taken from a fluvial sedimentary sequence at the archaeological site of the Dali Man, Shaanxi Province, China. K-feldspar coarse grains were extracted for measurement. Approximately 30–40% of the grains were sufficiently bright to measure, and after application of rejection criteria based on signal strength, recuperation, recycling ratio and saturation dose, ~10–15% of the grains were used for De calculation. The relationship of signal decay rate and form of De(t) with the recovery dose were investigated. The dose recovery ratios of the samples after initial bleaching with the four different light sources were within uncertainties of unity. No anomalous fading was observed. The over-dispersion of the recovered dose and De values were similar, suggesting neither incomplete resetting of the post-IR IRSL signals nor spatially heterogeneous dose rates significantly affected the natural dose estimates. The values of De obtained with the single K-feldspar grain post-IR IRSL protocol were in the range ~400–490 Gy. Combining all of the measured single-grain signals for each of the individual samples (into a ‘synthetic single aliquot’) increased the De estimates to the range ~700–900 Gy, suggesting that the grains screened-out by the rejection criteria may have the potential to cause palaeodose over-estimation, although this finding requires a more extensive investigation. Thermally transferred signals were found in the single K-feldspar grains post-IR IRSL protocol, and the proportion of thermally transferred signal to test-dose OSL signal (stimulation at 290 °C) from the natural dose was higher than from regenerative doses, and the proportion was grain- and dose-dependent. As such, TT-post-IR IRSL signals at 290 °C have the potential to cause dose underestimation, although this may be reduced by using larger test-dose irradiations. Our study demonstrates considerable potential in the post-IR IRSL method in providing chronological control in studies relevant to human evolution in the later-Pleistocene.  相似文献   

6.
Optically Stimulated Luminescence (OSL) signals of BeO ceramics were investigated using continuous wave (CW) OSL and Linearly Modulated (LM) OSL. It was found that both curves can be approximated using a linear combination of two first-order components. Experiments on the measurement temperature dependence have shown that these two components have nearly the same thermal quenching energies around 0.57 eV. Dependences of the OSL signal on preheat temperature and radiation dose were also examined. Thermal annealing experiments have shown that OSL signals originate from traps which are unstable near 340 °C, thus proving the suitability of the signals for dosimetric purposes. Dose response was found to be linear and a minimum detectable dose of ~10 μGy was found.  相似文献   

7.
The LM–OSL signal of quartz, while measured at room temperature, is dominated by an intermediate, broad and intense OSL component, so that its contribution and general characteristics are derived very accurately. Through a series of dose–response, bleaching and thermal decay at room temperature experiments, in conjunction with curve fitting studies, a component resolved analysis is carried out studying the correlation between this specific component, termed as LM–OSL component C2 and the 110 °C TL glow peak in quartz. The dose–response of these two luminescence components behaves exactly similar being linear at low doses and saturating at almost 100 Gy. Both signals decay exponentially under illumination, providing identical optical detrapping cross-section values. Residual of both luminescence signals after thermal decay at room temperature follows an exponential law, yielding similar mean half-lives. All previous luminescence features provide strong evidence for the electron trap being the same for both the 110 °C TL trap and the LM–OSL component C2. The results of the present work are very promising and clearly support the possibility of extrapolating the TL pre-dose methodology to the OSL pre-dose effect using only the LM–OSL component C2.  相似文献   

8.
《Radiation measurements》2007,42(2):190-197
An optically stimulated luminescence (OSL) age obtained from a Japanese tephra using quartz phenocrysts severely underestimated the known age. The characteristics of the OSL signals were investigated in order to understand the cause of the underestimation; the main OSL component of volcanic quartz has a thermodynamic lifetime of about 1700 years at room temperature, and it also seems to fade anomalously (i.e. athermally). Measurement of conventional red thermoluminescence (RTL) using a Ga–As photomultiplier tube was difficult due to the presence of a strong thermal background, although RTL gave an age consistent with the independent age. Furthermore, red isothermal TL (RITL) at 380 °C allowed the RTL signal to be separated from to the thermal background, and RITL ages of three volcanic quartz samples show good agreement with independent ages.  相似文献   

9.
The elevated temperature infrared stimulated luminescence (IRSL) and post-IR IRSL signals of potassium (K)-feldspars have recently garnered attention for their minimal rates of anomalous fading. The post-IR IRSL signal has been used to obtain age estimates for geological deposits, mostly in Europe. Studies on the behaviour of the IRSL and post-IR IRSL signals of K-feldspars from a wider range of geographic regions and depositional contexts are needed, particularly for regions where the OSL signal from quartz is poorly behaved. Discrepancies in the literature regarding the behaviours of the IRSL and TL signals of K-feldspars also highlight the need to characterise the behaviours of samples from a wide variety of contexts. This paper begins to address this problem by characterising and comparing the IRSL signals of a metamorphic and a volcanic K-feldspar sample from two sites in East Africa, a region in which the OSL signal from quartz has generally proven problematic for dating. We demonstrate that the metamorphic and volcanic K-feldspars have substantially different TL glow curves that respond differently to IR stimulation. The sample of metamorphic K-feldspar from Tanzania (MR9) has a peak at 430 °C that is associated with the IRSL signal and an optically less-sensitive peak at 350 °C, while the sample of volcanic K-feldspar from Ethiopia (MB3) exhibits a single broad TL region centred at ~230 °C that responds differently to IR stimulation. Differences in the change of IRSL decay curve shape with stimulation temperature suggest that the processes of IRSL production many vary between the two samples. Using dose recovery tests, we demonstrate that the IRSL (50 °C), IRSL (225 °C) and post-IR IRSL (50 °C, 225 °C) signals of sample MR9 are suitable for dose and age estimation using the single-aliquot regenerative-dose procedure, while those of sample MB3 are less suitable. The post-IR IRSL signal of the latter sample performs poorly in tests of SAR suitability and the three signals exhibit extremely high fading rates over laboratory timescales (g2days > 19%/decade).  相似文献   

10.
Various optically stimulated luminescence signals from K-feldspar have been used to determine the equivalent doses of sediment samples. Understanding the properties of these optical signals is critical to evaluate their applicability and limitations to optical dating. In this paper, some properties of IRSL, post-IR OSL and post-IR IRSL signals (detected in the UV region using U-340 filters) from a museum sample of K-feldspar were investigated by analyzing the relationships between optical and TL signals, and the effect of optical bleaching and heating on optical signals. The trap parameters of the different optical signals were calculated using the pulse annealing method. The results show that this sample exhibits two regenerated TL peaks at ~140 and ~330 °C. Corresponding to the low temperature TL peak, the OSL and post-IR OSL signals appear to be more associated with lower temperature TL than the IRSL signal measured at 50 °C. Corresponding to the high temperature TL peak, the post-IR IRSL signals mainly originate from the more thermally stable traps associated with the high temperature TL, compared with the IRSL and post-IR OSL signals. However, the post-IR IRSL225 °C signal is shown to be hard to be bleached by blue light and simulated sunlight, compared with the IRSL50 °C and low temperature post-IR IRSL signals. The implication for optical dating is that the elevated temperature post-IR IRSL signals can be preferentially applied over other signals from K-feldspar, but it is desirable that the effectiveness of the pre-depositional zeroing of these signals is assessed.  相似文献   

11.
《Radiation measurements》2009,44(2):149-157
In this study, we applied optically stimulated luminescence (OSL) dating to two fine grain sediment samples collected at Jeongokri, Korea. A single aliquot regenerative dose (SAR) procedure was applied to both polymineral grains and to chemically isolated (H2SiF6) quartz grains of 4–11 μm diameter. For polymineral fine grains, the OSL IR depletion ratio and the equivalent dose (De) plateau test appear to be equally sensitive indicators of appropriate IR stimulation time for use in the ‘double SAR’ protocol. Additionally, the OSL IR depletion ratio test gives an indication of the relative mineral composition of the samples, hence providing an assessment of the likelihood of obtaining a quartz-dominated [post-IR] OSL signal. Use of higher preheat temperatures would assist in thermally eroding the non-quartz component of the [post-IR] OSL signal from polyminerals. For the quartz fine grains, data from both natural De determinations and laboratory dose recovery tests are required to identify the appropriate preheat temperatures for dating, due to problems of thermal transfer. This phenomenon is particularly exaggerated for these samples due to the large De values (≥350 Gy) and hence low slope of the dose–response curve. The double SAR method cannot be applied ubiquitously, even after careful and rigorous study of one sample from a section. Quartz OSL dating using a range of preheat temperatures is suggested to be the most suitable method for OSL dating of fine grain sediments.  相似文献   

12.
Yellow stimulated luminescence (Y-OSL) is the light detected from potassium-rich feldspars at 410 nm under stimulation by a yellow light source emitting 590 nm. The investigation of this study aimed at understanding basic luminescence physics of Y-OSL in order to assess the suitability of the technique for dating. The Y-OSL signal properties tested were signal intensity, thermal assistance, thermal stability, sensitivity to daylight and the suitability of a single aliquot regenerative (SAR) protocol to be employed for equivalent dose (De) estimation. De measurements were conducted on samples of Holocene, last glacial and Tertiary age. The tests were undertaken on sedimentary feldspar separates extracted from aeolian, fluvial and coastal deposits.Results from experiments show that the signal intensity increases by measuring Y-OSL at elevated temperature suggesting thermal assistance characteristics similar to infrared stimulated luminescence (IRSL). The yellow stimulated signal remains unaffected by preheat temperatures up to ~200 °C suggesting higher thermal stability than the IRSL signal. The Y-OSL signal is less light sensitive than the IRSL signal and De residuals obtained from modern samples are up to 7 Gy indicating suitability of the technique for ‘older’ and well-bleached sediments. The dose recovery tests successfully recovered the given dose if the specific light sensitivity of Y-OSL is taken into account. For every sample Y-OSL De values obtained by a single aliquot regenerative dose protocol (SAR) are higher than those obtained by an IRSL SAR approach. From these results we infer high thermal stability and a minimal anomalous fading of the Y-OSL signal. We conclude that Y-OSL has a high potential to date Quaternary sediments that were sufficiently bleached in nature.  相似文献   

13.
《Radiation measurements》2007,42(2):144-155
The structure of the linearly modulated optically stimulated luminescence (LM-OSL) signal was studied for four sedimentary quartz samples, collected from different sites around Istanbul, Turkey. Applying a computerized deconvolution analysis to the LM-OSL curves, at least six individual components of first-order kinetics were identified and photoionization cross-section of each component was evaluated. The OSL dose–response curve of each component for each quartz sample was obtained, showing a remarkable differentiation from component to component. The behavior of a highly dosed sample to successive LM-OSL measurements was also studied showing a stable recuperation signal in the position of the “slow” and “medium” components and high resistance to OSL bleaching of the “slow” component. The individual sensitivity of each component as a function of the activation temperature was obtained. The sensitivity of each component was normalized over the respective sensitivity of the glow-peak at 110 °C of quartz in order to investigate the ability of the 110 °C glow-peak to act as a correction factor for all components of the LM-OSL curves examined.  相似文献   

14.
It has frequently been observed that certain roof tiles and bricks, especially from relatively modern European buildings, do not contain enough quartz grains in a suitable grain size range to permit dose reconstruction using thermoluminescence (TL) or optically stimulated luminescence (OSL) methods. In this paper the feasibility of using infrared-stimulated luminescence (IRSL) on the feldspar fraction of such bricks and tiles has been investigated. Appropriate preheating treatments were employed in order to select the most stable signals, and procedures were developed to enhance the signal to noise ratio. The possible effect of anomalous fading under application of these procedures was tested. In the dose range above 100 mGy, it has been demonstrated that using IRSL on the feldspar fraction of such material provides a feasible alternative to the use of green-light-stimulated luminescence (GLSL) on the quartz fraction, for the purposes of retrospective dosimetry. Furthermore, since the use of IRSL as described in this paper involves the measurement of polymineral fine grain fractions of bricks, a technique for the calibration of the built-in β source against the γ source in Secondary Standard Dosimetry facilities for routine use of the technique is described.  相似文献   

15.
Optically stimulated luminescence (OSL) measurements of quartz are widely used to measure equivalent dose (De). At radiation doses above ~100 Gy, saturation of traps results in a decrease in the rate of growth of the OSL signal, and this makes calculation of De increasingly difficult. A series of dose recovery experiments was undertaken using single grains of quartz from Kalambo Falls, Zambia to explore saturation of single grains. When the OSL signal from many grains is averaged, the characteristic dose (D0) is 47 Gy, typical of published values for quartz. However, D0 for individual grains varies from ~10 to 100 Gy. Doses up to two times the average D0 could be accurately recovered, but above this dose the De became increasingly underestimated. Overdispersion for this type of experiment should be zero, but was observed in all data sets; furthermore the value of overdispersion increased with De. An additional acceptance criterion, the Fast Ratio, is suggested for single grain OSL analysis. This criterion assesses the relative contribution of the fast component of the OSL signal. Including this as an additional acceptance criterion leads to an improved precision, with overdispersion reduced to zero, and improved accuracy in dose recovery at high doses.  相似文献   

16.
Biotite mineral grains from granitic rocks were subjected to luminescence studies with optical and thermal stimulation. Moderate thermoluminescence (TL) signals and weak optically stimulated luminescence (OSL) with blue-green light stimulation were detected after 50 Gy beta irradiation. No detectable infrared-stimulated luminescence (IRSL) was observed for natural and laboratory beta-irradiated samples. TL peaks at 118, 300, 360 and 480 °C can be identified from laboratory-irradiated samples. The 360 °C TL peak saturates at a higher dose than quartz, but shows significant anomalous fading after 80 days stored at room temperature. The potentials and problems for biotite used as a natural dosimeter are discussed.  相似文献   

17.
The fast, linearly modulated optically stimulated luminescence (LM-OSL) component in quartz is the main dosimetric signal used for the dating applications of this material. Since the blue light stimulation (470 nm, 40 mW cm ?2) time needed to obtain the fast LM-OSL component is less than 50 s the electron trapping levels responsible for it are still highly populated. In this way an active radiation history is created which could play an important role in the dosimetric characteristics of the fast OSL signal. In the present work the dose response behavior of the fast OSL signal is investigated in quartz samples with an annealed radiation history and quartz samples possessing an artificial radiation history. A computerized curve de-convolution analysis of the LM-OSL curves for 50 s stimulation time showed that it consists of three individual OSL components. The faster component C1 with peak maximum time around 5 s has a linear dose response in virgin samples, which turns to a slight superlinearity as a function of the artificial radiation history. On the other hand the component C2 with peak maximum time at 12 s is slightly superlinear which turns into strong superlinearity as a function of artificial radiation history. Finally, component C3 with peak maximum time at about 45 s is strongly superlinear for both virgin samples and as a function of artificial radiation history. The implications to practical application are discussed.  相似文献   

18.
For luminescence dating to be an accurate absolute dating technique it is very important that we are able to deliver absolutely known radiation doses in the laboratory. This is normally done using a radiation source (alpha, beta, X-ray) calibrated against an absolutely known reference source. Many laboratories have used the various different batches of Risø calibration quartz for the calibration of beta and X-ray sources, but these have been largely undescribed. Here we describe in detail the preparation and luminescence characteristics of a new quartz standard, based on a North Sea beach sand collected from south-western Denmark (Rømø). Two grain sizes (4–11 μm and 180–250 μm) have been examined in detail. These were pre-treated (annealed, dosed and annealed again) to sensitise and stabilise the luminescence signals before being given an absolutely known gamma dose from a point 137Cs source in scatter-free geometry. The luminescence characteristics are described; the very intense blue-light stimulated signal is dominated by the fast OSL component and the IR-stimulated signal is negligible. The material is shown to be suitable for measurement using SAR, and the dose recovery ratio is indistinguishable from unity with a standard deviation of <2% for multi-grain aliquots. The material is also shown to be suitable for single-grain calibration, with >80% of the grains giving a useful signal. Although there is an unexplained dispersion in our calibration data of ∼3% (which we cannot attribute to instrument variability), we nevertheless conclude that this material is very suitable for transferring absolute known doses from a standardised gamma source to in-built irradiation sources.  相似文献   

19.
This paper presents selected optically stimulated luminescence properties of Lu2SiO5:Ce single crystalline films grown using Liquid Phase Epitaxy technique. Comparison of continuous wave optically stimulated luminescence decay curves under blue and green light stimulation is shown. The dose response characteristic is found to be linear in the studied range from 100 μGy to 1 Gy. Analyses of the linearly modulated optically stimulated luminescence signal enabled establishing of the photoionization cross sections for blue light (470 nm). Bleachability and thermal stability of CW–OSL signal are discussed, as well as preliminary results of the fading study.  相似文献   

20.
The alkali halide NaCl (Common salt) is an environmentally-abundant phosphor of considerable potential for retrospective dosimetry and radiological event analysis due to its high sensitivity to ionising radiation when analysed by Thermoluminescence (TL), Optically-stimulated luminescence (OSL) or Infrared-stimulated luminescence (IRSL). We report here aspects of luminescence from NaCl relevant to the development of valid protocols for measurement of recent ionising radiation exposure. The timescale of interest in this application is from days to decades, hence our emphasis is on detection and characterisation of TL emission in the 100–300 °C range, and of OSL and IRSL emissions measured following only low temperature preheating (160 °C). A collection of 19 salt samples was assembled, including samples of rock salt and domestic salt produced by evaporation from brine. Analysis of TL emission spectral changes, together with previously reported TL, OSL and IRSL sensitivity changes, confirmed activation of sensitivity change by exposure to temperatures exceeding 160 °C. Kinetic analysis using Chen's method found E = 0.943 eV and s = 5.1 × 1011 s?1 for the 100 °C TL peak, giving a lifetime at 20 °C consistent with previous calculations and in the range of 7–14 h.  相似文献   