首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Madhavi  A.  Naidu  A.  Subba Rao  D. V.  Srinivasu  P. 《Chromatographia》2009,69(11):1413-1419

A novel liquid chromatographic method for analysis three potential impurities in brimonidine tartrate drug substance has been developed and validated. Efficient chromatographic separation was achieved on a C8 column (250 mm × 4.6 mm, 5-μm particles) with a simple mobile-phase gradient at a flow rate of 1.0 mL min−1. Quantification was achieved by use of ultraviolet detection at 248 nm. Resolution between brimonidine tartrate and its three potential impurities was greater than 3.0. Regression analysis showed the r value (correlation coefficient) was >0.999 for brimonidine and its three impurities. The method was capable of detecting all three impurities of brimonidine tartrate at levels below 0.07 μg in a test concentration of brimonidine tartrate of 1.0 mg mL−1 and for an injection volume of 10 μL. A solution of brimonidine tartrate in acetonitrile–water 2:8 (v/v) was stable for 48 h. The drug was subjected to stress conditions as prescribed by the ICH. Degradation was found to occur slightly under oxidative stress conditions but the drug was stable to aqueous, acidic, and basic hydrolysis, and photolytic and thermal stress. The assay of the stressed samples was calculated relative to a qualified reference standard and the mass balance was found close to 99.8%. The method was validated for linearity, accuracy, precision, and robustness.

  相似文献   

2.
A novel liquid chromatographic method for analysis three potential impurities in brimonidine tartrate drug substance has been developed and validated. Efficient chromatographic separation was achieved on a C8 column (250 mm × 4.6 mm, 5-μm particles) with a simple mobile-phase gradient at a flow rate of 1.0 mL min?1. Quantification was achieved by use of ultraviolet detection at 248 nm. Resolution between brimonidine tartrate and its three potential impurities was greater than 3.0. Regression analysis showed the r value (correlation coefficient) was >0.999 for brimonidine and its three impurities. The method was capable of detecting all three impurities of brimonidine tartrate at levels below 0.07 μg in a test concentration of brimonidine tartrate of 1.0 mg mL?1 and for an injection volume of 10 μL. A solution of brimonidine tartrate in acetonitrile–water 2:8 (v/v) was stable for 48 h. The drug was subjected to stress conditions as prescribed by the ICH. Degradation was found to occur slightly under oxidative stress conditions but the drug was stable to aqueous, acidic, and basic hydrolysis, and photolytic and thermal stress. The assay of the stressed samples was calculated relative to a qualified reference standard and the mass balance was found close to 99.8%. The method was validated for linearity, accuracy, precision, and robustness.  相似文献   

3.
4.

A new, sensitive, stability indicating gradient RP-LC related substances and assay method has been developed for the quantitative determination of entacapone in bulk drugs. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination of buffer and acetonitrile. Buffer consisted of 0.1% orthophosphoric acid, delivered in a gradient mode and quantitation was carried out using ultraviolet detection at 220 nm with a flow rate of 1.5 mL min−1. In the developed LC method the resolution (R s ) between entacapone and its three potential process impurities were found to be >2.0. Regression analysis showed an r 2 value (correlation coefficient) >0.99 for entacapone and its three potential impurities. This method was capable to detect all three process impurities of entacapone at a level of 0.003% with respect to test concentration of 0.5 mg mL−1 for a 20 μL injection volume. The inter- and intra-day precision values for all three impurities and for entacapone was found to be within 2.0% RSD. The method has shown good and consistent recoveries for entacapone in bulk drugs (99.2–101.5%) and its three impurities (99.5–102.2%). The test solution was found to be stable in diluent for 48 h. The drug substances were subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in acid stress, base stress and oxidative conditions. The stressed test solutions were assayed against the qualified working standard of entacapone and the mass balance in each case was close to 99.7% indicating that the developed method was stability-indicating. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.

  相似文献   

5.
A new, sensitive, stability indicating gradient RP-LC related substances and assay method has been developed for the quantitative determination of entacapone in bulk drugs. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination of buffer and acetonitrile. Buffer consisted of 0.1% orthophosphoric acid, delivered in a gradient mode and quantitation was carried out using ultraviolet detection at 220 nm with a flow rate of 1.5 mL min?1. In the developed LC method the resolution (R s ) between entacapone and its three potential process impurities were found to be >2.0. Regression analysis showed an r 2 value (correlation coefficient) >0.99 for entacapone and its three potential impurities. This method was capable to detect all three process impurities of entacapone at a level of 0.003% with respect to test concentration of 0.5 mg mL?1 for a 20 μL injection volume. The inter- and intra-day precision values for all three impurities and for entacapone was found to be within 2.0% RSD. The method has shown good and consistent recoveries for entacapone in bulk drugs (99.2–101.5%) and its three impurities (99.5–102.2%). The test solution was found to be stable in diluent for 48 h. The drug substances were subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in acid stress, base stress and oxidative conditions. The stressed test solutions were assayed against the qualified working standard of entacapone and the mass balance in each case was close to 99.7% indicating that the developed method was stability-indicating. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

6.
A novel, sensitive, stability-indicating gradient RP-LC method has been developed for quantitative analysis of balsalazide disodium and its related impurities both in the bulk drug and in pharmaceutical dosage forms. Efficient chromatographic separation was achieved on a C18 stationary phase with a simple mobile-phase gradient prepared from methanol and phosphate buffer (10 mm potassium dihydrogen orthophosphate monohydrate, adjusted to pH 2.5 by addition of orthophosphoric acid). The mobile-phase flow rate was 1.0 mL min?1. Quantification was achieved by use of ultraviolet detection at 240 nm. Under these conditions resolution of balsalazide disodium from its three potential impurities was greater than 2.0. Regression analysis resulted in a correlation coefficient greater than 0.99 for balsalazide disodium and all three impurities. This method was capable of detecting the three impurities at 0.003% of the test concentration of 0.3 mg mL?1, using an injection volume of 10 μL. Inter-day and intra-day precision for all three impurities and for balsalazide disodium was within 2.0% RSD. Recovery of balsalazide disodium from the bulk drug (99.2–101.5%) and from pharmaceutical dosage forms (99.8–101.3%), and recovery of the three impurities (99.1–102.1%) was consistently good. The test solution was found to be stable in 70:30 (v/v) methanol–water for 48 h. When the drug was subjected to hydrolytic, oxidative, photolytic, and thermal stress, acidic and alkaline hydrolysis and oxidizing conditions led to substantial degradation. The RP-LC method was validated for linearity, accuracy, precision, and robustness.  相似文献   

7.
A simple, sensitive isocratic rapid resolution liquid chromatographic assay method has been developed for the quantitative determination of quetiapine hemifumarate in bulk active pharmaceutical ingredient, used for the treatment of schizophrenia. The developed method is also applicable for the process related impurities determination. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination delivered in a isocratic mode and quantification was by ultraviolet detection at 225 nm at a flow rate of 1.0 mL min?1. In the developed LC method the resolution between quetiapine hemifumarate and its three potential impurities was found to be greater than 2.0. Regression analysis showed an r value (correlation coefficient) greater than 0.99 for quetiapine hemifumarate and its three impurities. This method was capable to detect all three impurities of quetiapine hemifumarate at a level of 0.003% with respect to test concentration of 1.0 mg mL?1 for a 3 μL injection volume. The bulk active pharmaceutical ingredient was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in oxidative stress conditions. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.5%. The developed RR-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

8.
A novel, sensitive, stability indicating RP-LC method has been developed for the quantitative determination of deferasirox, its related impurities in both bulk drugs and pharmaceutical dosage forms. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination delivered in an isocratic mode and quantitation was by ultraviolet detection at 245 nm. The mobile phase consisted of buffer, acetonitrile and methanol (50:45:5, v/v) delivered at a flow rate of 1.0 mL min?1. Buffer consisted of 10 mM potassium dihydrogen orthophosphate monohydrate, pH adjusted to 3.0 by using orthophosphoric acid. In the developed LC method the resolution (R s ) between deferasirox and its four potential impurities was found to be greater than 2.0. Regression analysis showed an r value (correlation coefficient) greater than 0.999 for deferasirox and its four impurities. This method was capable to detect all four impurities of deferasirox at a level of 0.002% with respect to test concentration of 0.5 mg mL?1 for a 10 μL injection volume. The inter- and intra-day precision values for all four impurities and for deferasirox was found to be within 2.0% RSD. The method showed good and consistent recoveries for deferasirox in bulk drugs (98.3–101.1%), pharmaceutical dosage forms (100.2–103.1%) and for its all the four impurities (99.7–102.1%). The test solution was found to be stable in methanol for 48 h. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in acid stress hydrolysis. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.95%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

9.
The present paper describes the development of a stability indicating reversed phase column liquid chromatographic method for aripiprazole in the presence of its impurities and degradation products generated from forced decomposition studies. The drug substance was subjected to stress conditions of aqueous hydrolysis, oxidative, photolytic and thermal stress degradation. The degradation of aripiprazole was observed under acid hydrolysis and peroxide. The drug was found to be stable to other stress conditions attempted. Successful separation of the drug from the synthetic impurities and degradation products formed under stress conditions was achieved on an Inertsil phenyl column using a mixture of 0.2% trifluoroacetic acid and acetonitrile (55:45, v/v). The developed LC method was validated with respect to linearity, accuracy, precision, specificity and robustness. The assay method was found linear in the range of 25–200 μg mL?1 with a correlation coefficient of 0.9999 and the linearity of the impurities were established from LOQ to 0.3%. Recoveries of the assay and impurities were found between 97.2 and 104.6%. The developed LC method for the related substances and assay determination of aripiprazole can be used to evaluate the quality of regular production samples. It can also be used to test the stability samples of aripiprazole. To the best of our knowledge, the validated stability indicating LC method which separates all the impurities disclosed in this investigation was not published elsewhere.  相似文献   

10.
A novel liquid chromatographic method has been developed and validated for the determination of ranolazine, its potential four impurities in drug substance and drug products. Efficient chromatographic separation was achieved on a C18 stationary phase (150 × 4.6 mm, 3.0 microns particles) with simple mobile phase combination delivered in gradient mode at a flow rate of 1.0 mL min?1 at 210 nm. In the developed method, the resolution between ranolazine and its four potential impurities was found to be greater than 2.0. Regression analysis shows an r value (correlation coefficient) greater than 0.999 for ranolazine and for its four impurities. This method was capable to detect all four impurities of ranolazine at a level below 0.004% with respect to test concentration of 1.0 mg mL?1 for a 10 μL injection volume. The method has shown good, consistent recoveries for ranolazine (98.8–101.1%) and for its four impurities (97.2–100.3). The test solution was found to be stable in the diluent for 48 h. The drug was subjected to stress conditions. The mass balance was found close to 99.5%.  相似文献   

11.
A novel liquid chromatographic method for the analysis of four potential impurities in the anti-cancer agent Bexarotene has been developed and validated using efficient chromatographic separation, achieved on a C18 column (50 mm × 2.1 mm, 1.7-μm particles) with a simple isocratic mobile phase at a flow rate of 0.5 mL min?1. The mobile phase consisted of a 70:30:0.1 (v/v/v) mixture of acetonitrile, water and trifluoroacetic acid, and quantification was achieved by use of ultraviolet detection at 260 nm. Resolution between Bexarotene and its four potential impurities was greater than 2.0. Regression analysis showed the r value (correlation coefficient) was >0.999 for Bexarotene and its four impurities. The method was capable of detecting all four impurities of Bexarotene at levels below 0.10 μg in a Bexarotene test concentration of 0.5 mg mL?1 using an injection volume of 5 μL. The recovery for Bexarotene in assay method at a 100% level was observed to be 99.1 ± 0.32% with % RSD value of 0.5% for drug substance and 98.9 ± 0.46% for Bexarotene capsules with % RSD value of 0.4%. Recovery of imp-1, imp-2, imp-3, and imp-4 from bulk drug samples ranged from 96.3 to 102.0%. Recovery of imp-1, imp-2, imp-3, and imp-4 from Bexarotene Capsule samples ranged from 97.2 to 101.4%. A solution of Bexarotene in ethanol was stable for 48 h. The drug was also subjected to stress conditions as prescribed by ICH Guidelines. Degradation was found to occur under acidic and basic hydrolysis stress conditions; however, the drug was stable to oxidative, photolytic, and thermal stress. Assay of the stressed samples was calculated relative to a qualified reference standard and the mass balance was found to be close to 99.8%. The method was validated for linearity, accuracy, precision, and robustness.  相似文献   

12.
A simple, sensitive gradient RP-LC assay method has been developed for the quantitative determination of amtolmetin guacyl in bulk drug, used as anti-inflammatory drug. The developed method is also applicable for related substances determination. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination delivered in a gradient mode and quantification was carried out using ultraviolet detection at 313 nm at a flow rate of 1.0 mL min?1. In the developed LC method the resolution between Amtolmetin Guacyl and its three potential impurities was found to be greater than 2.0. Regression analysis shows an r value (correlation coefficient) greater than 0.99 for amtolmetin guacyl and its three impurities. This method was capable to detect all three impurities of amtolmetin guacyl at a level of 0.002% with respect to test concentration of 0.5 mg mL?1 for a 10 μL injection volume. The inter- and intra-day precision values for all three impurities and for amtolmetin guacyl was found to be within 2.0% RSD at its specification level. The method has shown good and consistent recoveries for amtolmetin guacyl (99.2–101.5%) and its three impurities (94.5–104.8%). The test solution was found to be stable in diluent for 48 h. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in oxidative stress conditions. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.6%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

13.
A forced degradation study on ropinirole hydrochloride in bulk and in its modified release tablets was conducted under the conditions of hydrolysis, oxidation and photolysis in order to develop an isocratic stability-indicating LC-UV method for quantification of the drug in tablets. An impurity peak in standard solution was found to increase under acidic and neutral hydrolytic conditions while another degradation product was formed under alkaline condition. The drug and its degradation products were optimally resolved on a Hypersil C18 column with mobile phase composed of diammonium hydrogen orthophosphate (0.05 M; pH 7.2), tetrahydrofuran and methanol (80:15:5% v/v) at a flow rate of 1.0 mL min?1 at 30 °C using 250 nm as detection wavelength. The method was linear in the range of 0.05–50 μg mL?1 drug concentrations. The %RSD of inter- and intra-day precision studies was <1. The system suitability parameters remained unaffected during quantification of the drug on three different LC systems. Excellent recoveries (101.59–102.28%) proved that the method was sufficiently accurate. The LOD and LOQ were found to be 0.012 and 0.040 μg mL?1, respectively. Degradation behaviour of the drug in both bulk and tablets was similar. The drug was very unstable to hydrolytic conditions but stable to oxidative and photolytic conditions. The method can be used for rapid and accurate quantification of ropinirole hydrochloride in tablets during stability testing. Based on chemical reactivity of ropinirole in different media, the degradation products were suspected to be different from the known impurities of the drug.  相似文献   

14.
A simple, sensitive gradient RP-LC assay method has been developed for the quantitative determination of vardenafil HCl in bulk drug and in pharmaceutical dosage forms, used to treat erectile dysfunction. The developed method is also applicable for the related substances determination. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination delivered in a gradient mode and quantification was carried out using ultraviolet detection at a flow rate of 1.0 mL min?1. In the developed LC method the resolution between vardenafil and its four potential impurities was found to be greater than 3.0. Regression analysis shows an r 2 value (correlation coefficient) greater than 0.99 for vardenafil and its four impurities. This method was capable of detecting all four impurities of vardenafil at a level of 0.009% with respect to test concentration of 1.0 mg mL?1 for a 10 μL injection volume. The method has shown good and consistent recoveries for vardenafil (98.4–100.6%) and its four impurities (93.5–106.2%). The test solution was found to be stable in the diluent for 48 h. Mass balance was found close to 99.4%.  相似文献   

15.
A simple, selective and sensitive stability indicating LC method has been developed and validated for the determination of faropenem in bulk drug and pharmaceutical formulations in the presence of degradation products. The separation was achieved by using an isocratic mobile phase mixture of acetate buffer of pH 3.5 and methanol (65:35, v/v) and 250 mm × 4.6 mm I.D., 5 μm particle size SGE make Wakosil C-18 AR column at flow rate of 1.0 mL min?1 with detection at 305 nm. The retention time of faropenem is 6.63 min and was linear in the range of 5–75 μg mL?1 (r = 0.9999). The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation and was found to be unstable in all the stress conditions. The proposed method was successfully employed for quantification of faropenem in bulk drug and its pharmaceutical formulations.  相似文献   

16.
A simple reverse phase liquid chromatographic method was developed for the quantitative determination of desipramine hydrochloride and its related impurities in bulk drugs which is also stability-indicating. During the forced degradation at hydrolysis, oxidative, photolytic and thermal stressed conditions, the degradation results were only observed in the oxidative stress condition. The blend of the degradation product and potential impurities were used to optimize the method by an YMC Pack Pro C18 stationary phase. The LC method employs a linear gradient elution with the water–acetonitrile–trifluoroacetic acid as mobile phase. The flow rate was 1.0 mL min?1 and the detection wavelength 215 nm. The stressed samples were quantified against a qualified reference standard and the mass balance was found close to 99.0% (w/w) when the response of the degradant was considered to be equal to the analyte (i.e. desipramine). The developed RP-LC method was validated in agreement with ICH requirements.  相似文献   

17.
A novel, sensitive, stability indicating RP-LC method has been developed for the quantitative determination of mitotane, its impurity in both bulk drugs and pharmaceutical dosage forms. Efficient chromatographic separation was achieved using a C18 stationary phase with simple mobile phase combination delivered in an isocratic mode and quantitation was by ultraviolet detection at a wavelength of 230 nm. The mobile phase consisted of buffer and acetonitrile (25:75, v/v) delivered at a flow rate of 1.0 mL min?1. Buffer consisted of 10 mM potassium dihydrogen orthophosphate monohydrate, pH adjusted to 2.5 by orthophosphoric acid. In the developed LC method the resolution (R s ) between mitotane and its impurity namely Imp-1 was found to be greater than 2.5. Regression analysis shows an r value (correlation coefficient) greater than 0.999 for mitotane and its impurity. This method was capable to detect the impurity of mitotane at a level of 0.003% with respect to test a concentration of 0.2 mg mL?1 for a 10 μL injection volume. The inter- and intra-day precision values for mitotane and its impurity was found to be within 2.0% RSD. The method has shown good and consistent recoveries for mitotane in bulk drugs (99.2–101.5%), pharmaceutical dosage forms (98.2–103.1%) and for its impurity (99.7–102.1%). The test solution was found to be stable in diluent for 48 h. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in basic stress hydrolysis. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.97%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

18.

A simple reverse phase liquid chromatographic method was developed for the quantitative determination of desipramine hydrochloride and its related impurities in bulk drugs which is also stability-indicating. During the forced degradation at hydrolysis, oxidative, photolytic and thermal stressed conditions, the degradation results were only observed in the oxidative stress condition. The blend of the degradation product and potential impurities were used to optimize the method by an YMC Pack Pro C18 stationary phase. The LC method employs a linear gradient elution with the water–acetonitrile–trifluoroacetic acid as mobile phase. The flow rate was 1.0 mL min−1 and the detection wavelength 215 nm. The stressed samples were quantified against a qualified reference standard and the mass balance was found close to 99.0% (w/w) when the response of the degradant was considered to be equal to the analyte (i.e. desipramine). The developed RP-LC method was validated in agreement with ICH requirements.

  相似文献   

19.

A novel, sensitive, stability indicating RP-LC method has been developed for the quantitative determination of mitotane, its impurity in both bulk drugs and pharmaceutical dosage forms. Efficient chromatographic separation was achieved using a C18 stationary phase with simple mobile phase combination delivered in an isocratic mode and quantitation was by ultraviolet detection at a wavelength of 230 nm. The mobile phase consisted of buffer and acetonitrile (25:75, v/v) delivered at a flow rate of 1.0 mL min−1. Buffer consisted of 10 mM potassium dihydrogen orthophosphate monohydrate, pH adjusted to 2.5 by orthophosphoric acid. In the developed LC method the resolution (R s ) between mitotane and its impurity namely Imp-1 was found to be greater than 2.5. Regression analysis shows an r value (correlation coefficient) greater than 0.999 for mitotane and its impurity. This method was capable to detect the impurity of mitotane at a level of 0.003% with respect to test a concentration of 0.2 mg mL−1 for a 10 μL injection volume. The inter- and intra-day precision values for mitotane and its impurity was found to be within 2.0% RSD. The method has shown good and consistent recoveries for mitotane in bulk drugs (99.2–101.5%), pharmaceutical dosage forms (98.2–103.1%) and for its impurity (99.7–102.1%). The test solution was found to be stable in diluent for 48 h. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in basic stress hydrolysis. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.97%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.

  相似文献   

20.
A gradient HPLC method coupled with diode array detection was developed and fully validated for the analysis of impurities in ropinirole using a Kromasil® C8 100 Å (250 × 4.6 mm, 5 μm) column with a flow rate 1.0 mL min?1 and detection at 250 nm. The mobile phase component A consisted of a mixture of 19.6 mM aqueous potassium dihydrogen phosphate–acetonitrile (98:2 v/v), pH adjusted to 7.0 with triethylamine and the mobile phase component B consisted of acetonitrile. The method was validated in terms of linearity, sensitivity, precision, accuracy and stability. The calibration curves for ropinirole and its five impurities showed good linearity (r > 0.998) within the calibration ranges tested. The intra- and inter-day RSD values were <3.9 %, while the relative percentage error E r was <5.8 % for all compounds. Accelerated stability studies performed under various stress conditions including oxidation, hydrolysis and UV light irradiation at 254 nm proved the selectivity of the procedure. Long-term stability studies performed on blistered tablets and under various conditions of heat and humidity indicate the presence of four of the studied impurities in less than 0.07 %. The method was applied successfully to the detection and determination of ropinirole impurities in pharmaceutical formulations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号