首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We report on the chiral separation of pharmacologically active dihydropyrimidinones by capillary electrophoresis (CE) using carboxymethyl-beta-cyclodextrin as chiral selector. The influence of selector concentration, pH, and the addition of varying amounts of methanol is investigated. Out of 21 compounds investigated, 19 were resolved, 13 with baseline separation.  相似文献   

2.
Capillary electrophoresis (CE) with carboxymethylated beta- or gamma-cyclodextrins was used to achieve the rapid enantiomeric separation of a set of basic drugs. The enantiomers of 12 chiral amino-containing pharmaceutical compounds belonging to various therapeutic categories were analyzed by CE using an uncoated 60 cm x 75 microm I.D. silica capillary. Several experimental parameters such as the nature, concentration and pH of the buffer, nature and concentration of the anionic cyclodextrin and temperature were studied in order to optimize the enantiomeric separation. The variation of the solute partition coefficient for the chiral selector, the enantioselectivity and resolution factors are used to assess the quality of the chiral separation. It is shown that the solute affinity for the chiral selector is not related to its enantioresolution factor. None of the two cyclodextrin selectors used was able to separate the whole set of basic drugs.  相似文献   

3.
A chiral ionic liquid (IL), S-[3-(chloro-2-hydroxypropyl)trimethylammonium] [bis((trifluoromethyl)sulfonyl)amide] (S-[CHTA](+)[Tf(2)N](-)), which can be easily and readily synthesized in a one-step process from commercially available reagents, can be successfully used both as co-electrolyte and as a chiral selector for CE. A variety of pharmaceutical products including atenolol, propranolol, warfarin, indoprofen, ketoprofen, ibuprofen and flurbiprofen, can be successfully and baseline separated with the use of this IL as electrolyte. Interestingly, while S-[CHTA](+)[Tf(2)N](-) can also serve as a chiral selector, enantioseparation cannot be successfully achieved with S-[CHTA](+)[Tf(2)N](-) as the only chiral selector. In the case of ibuprofen, a second chiral selector, namely a chiral anion (sodium cholate), is needed for the chiral separation. For furbiprofen, in addition to S-[CHTA](+)[Tf(2)N](-) and sodium cholate, a third and neutral chiral selector, 1-S-octyl-beta-d-thioglucopyranoside (OTG), is also needed. Due to the fact that the chirality of this chiral IL resides on the cation (i.e., -[CHTA](+)), and that needed additional chiral selector(s) are either chiral anion (i.e., cholate) or chiral neutral compound (OTG), the results obtained seem to suggest that additional chiral selector(s) are needed to provide the three-point interactions needed for chiral separations.  相似文献   

4.
毛细管电泳在手性分离中的应用及进展   总被引:10,自引:0,他引:10  
王义明  罗国安 《分析化学》1995,23(7):850-857
本文评述了近年来毛细管电泳在手性分离中的应用及进展,介绍了毛细管电泳分离手性对映射的数学模型、五种不同的分离模式及机理、七种常用的手性选择性类型及其在药学、环境和生命科学中的应用、研究中需优化的操作参数及其发展方向。  相似文献   

5.
毛细管电泳-安培检测法分离分析手性药物索他洛尔   总被引:1,自引:0,他引:1  
采用毛细管电泳-柱端喷壁式安培检测技术,建立了痕量手性药物索他洛尔的分离检测新方法。以1.5%(w/V)羧甲基-β-环糊精为手性选择试剂,借助于环糊精-客体包合物的拆分原理,索他洛尔对映异构体在优化的分离条件:50mmol/LTris-H3PO4缓冲液(pH5.5),分离电压21kV,进样条件18kV/10s,工作电位1150mV(vs.Ag/AgCl),可实现基线分离,线性范围为5~500μg/L;异构体Ⅰ和Ⅱ的检出限(S/N=3)分别为2.0和1.9μg/L。本方法用于模拟血清样品分析,结果令人满意。  相似文献   

6.
In capillary electrophoresis (CE), separation of enantiomers of a chiral compound can be achieved through the chiral interactions and/or complex formation between the chiral selector and the enantiomeric analytes on leaving their diastereomeric forms with different stability constants and hence different mobilities. A great number of chiral selectors have been employed in CE and among them macrocyclic antibiotics exhibited excellent enantioselective properties towards a wide number of racemic compounds. The use of azithromycin (AZM) as a chiral selector has not been reported previously. This work reports the use of AZM as a chiral selector for the enantiomeric separations of five chiral drugs and one amino acid (tryptophan) in CE. The enantioseparation is carried out using polar organic mixtures of acetonitrile (ACN), methanol (MeOH), acetic acid and triethylamine as run buffer. The influences of the chiral selector concentration, ACN/MeOH ratio, applied voltage and capillary temperature on enantioseparation are investigated. The results show that AZM is a viable chiral selector in CE for the enantioseparation of the type of chiral drugs investigated.  相似文献   

7.
Lignans are dimeric phenylpropanoid compounds in plants that enjoy increasing medicinal interest because of their phytoestrogen activity. Lignans are chiral compounds and for most natural occurring lignans, chirality is not known. Separation of racemic matairesinol by CE in a non-coated silica capillary with carboxymethyl-beta-cyclodextrin as chiral selector in phosphate buffer was successful. Electrolyte and selector concentrations and pH were systematically optimized in order to obtain baseline separation and short analysis times. Matairesinol from safflower fruit was determined as (-)-enantiomer. Quantitation results for matairesinol with the optimized method after calibration with authentic lignan were very similar to those by HPLC. The limit of detection is 2 microg/mL sample by DAD detection.  相似文献   

8.
Enantiomer separations by CE employing nonaqueous conditions are reviewed. The general focus of this article is directed towards solvent effects on chiral recognition and the separation mechanism. After a general discussion of solvent effects on the individual processes involved in CE enantiomer separation, specifics for various selector classes are discussed together with a few applications of enantioselective nonaqueous CE.  相似文献   

9.
Chiral separations using the macrocyclic antibiotics: a review   总被引:4,自引:0,他引:4  
The macrocyclic antibiotics have recently gained popularity as chiral selectors in CE, HPLC and TLC. The macrocyclic antibiotics used for chiral separations include the ansamycins, the glycopeptides, and the polypeptide antibiotic thiostrepton. Although not strictly considered macrocyclic antibiotics, the aminoglycosides are antibiotics that have been used for chiral separations in CE. More chiral analytes have been resolved using the glycopeptides than with the other macrocyclic antibiotics combined. The glycopeptides vancomycin, ristocetin A and teicoplanin have been used extensively as chiral selectors in CE, with ristocetin A appearing to be the most useful chiral selector followed by vancomycin and teicoplanin, respectively. The macrocyclic antibiotics have also been used as chiral bonded phases in HPLC, and HPLC stationary phases based on vancomycin, ristocetin A and teicoplanin have been commercialized. Ristocetin A seems to be the most useful glycopeptide HPLC bonded phase, but its greater expense can be a drawback. The macrocyclic antibiotics have been used with micelles to improve efficiency, provide unique selectivity, and extend the range of separations to neutral solutes. Changing the macrocyclic antibiotic used in CE or HPLC can significantly alter the enantioselectivity of the separations. In fact, the glycopeptide antibiotics are complementary to one another, where if a partial enantioresolution is obtained with one glycopeptide, there is a high probability that a baseline or better separation can be obtained with another.  相似文献   

10.
18-Crown-6 tetracarboxylic acid (18C6H4) has been successfully used as a chiral selector for capillary electrophoretic (CE), high-performance liquid chromatographic (HPLC), and gas chromatographic (GC) separation of the enantiomers of DL-amino compounds. We have previously used X-ray crystallographic analysis and HPLC with an immobilized 18C6H4 chiral stationary phase to study chiral recognition by 18C6H4 of several DL amino acids (DL-AA). In this study CE was used for chiral recognition of several DL-AA in electrolyte solution containing 18C6H4, in which the analyte (D or L amino acid) interacts freely. Among 14 DL-AA investigated, the enantiomers of nine (Glu, Ile, Met, PheG, Phe, Ser, Tyr, Val, and Thr) were successfully recognized in 4-15 mM 18C6H4. Indirect photometric detection with a cationic dye, chrysoidine, was used to monitor non-chromophoric DL-AA. Among nine successfully recognized DL-AA, the D forms of Ser, Thr and Met migrated faster than the corresponding L forms. The strengths of interactions predicted from the order of migration of each enantiomer in CE were different from those in HPLC analysis. The different enantiomer recognition probably can be ascribed to the difference between CE in which the selector is not immobilized and HPLC in which the selector is immobilized by means of a spacer.  相似文献   

11.
The chiral separation of halogenated amino acids by ligand-exchange CE is described. Halogenated amino acids attracted increasing interest in recent years because of their physiological activities. Different chiral selectors, as there are L-4-hydroxyproline, L-histidine, and N-alkyl derivatives of L-4-hydroxyproline in form of their copper(II) complexes, are compared for their chiral recognition ability for halogenated amino acids. The influence of various parameters, such as selector concentration, pH, organic modifier, and field strength, on the resolution was investigated. All halogenated amino acids investigated were baseline-separated under optimized conditions.  相似文献   

12.
Six reducing monosaccharides (mannose, galactose, fucose, glucose, xylose, and arabinose) were derivatized with 1-phenyl-3-methyl-5-pyrazolone (PMP) and chiral resolution of these racemic PMP-monosaccharides was studied by ligand-exchange CE using borate anion as a central ion of the chiral selector and (S)-3-amino-1,2-propanediol (SAP) as a chiral selector ligand. PMP-mannose, PMP-galactose and PMP-fucose were successfully enantioseparated. Lowering the capillary temperature increased the resolution of PMP-mannose system, but decreased that of PMP-galactose and PMP-fucose systems. Whereas the maximum resolution was obtained at pH 8.9 in the PMP-mannose system, resolution increased gradually with pH in the PMP-galactose and PMP-fucose systems. Expecting the formation of the ternary borate complexes with SAP and PMP-monosaccharide in the CE experiments, the optimized structures of the borate diastereomers were obtained by semiempirical molecular orbital calculations to discuss the structural difference of the diastereomers in connection with the enantioseparation behaviors.  相似文献   

13.
Chiral separation of iodiconazole, a new antifungal drug, and 12 new structurally related triadimenol analogues had been developed by capillary electrophoresis (CE) using hydroxypropyl-γ-cyclodextrin (HP-γ-CD) as the chiral selector. The effect of structural features of analytes on Δt and Rs was studied under the optimum separation conditions. Using molecular docking technique and binding energy calculations, the inclusion process between HP-γ-CD and enantiomers was investigated and chiral recognition mechanisms were discussed. The results suggest that hydrogen bonding between fluorine at position 4 of the phenyl group beside the chiral carbon and the hydroxyl group on the HP-γ-CD rim and face to face π–π interactions between two phenyl rings highly contributed to the enantiorecognition process between HP-γ-CD and iodiconazole. The N-methyl group beside chiral carbon also played an important role in enantiomeric separation. Additionally, the big difference in binding energy (ΔΔE) highly contributed to good separation in the presence of HP-γ-CD chiral selector, which may be a helpful initial guide for chiral selector selection and predicting the result of enantioseparation. Furthermore, the new mathematical equation established based on the results of molecular mechanics calculations exhibited good capability in predicting chiral separation of these triadimenol analogues using HP-γ-CD mediated CE.  相似文献   

14.
The 2S- and 2R-diastereomers of major flavanone-7-O-glycosides found in sweet orange (Citrus sinensis), mandarine (Citrus deliciosa), grapefruit (Citrus paradisi), lemon (Citrus limon), and sour or bitter orange juice (Citrus aurantium) were separated for the first time by chiral capillary electrophoresis (CE) employing various buffers with combined chiral selectors. Native cyclodextrins (CDs), neutral and charged CD derivatives were examined as chiral additives to the background electrolyte (BGE). Separation efficiency has not proved satisfactory with one single CD as chiral selector in the buffer, a full and simultaneous separation could often be achieved only by using combined buffer with two different CDs. Chiral separation of major flavanones in sweet orange, mandarine and grapefruit juices raised more difficulties than in lemon and sour orange juices as narirutin will not readily build complexes with most CDs. Diastereomeric flavanones of mature and immature grapefruits were compared and some differences were found: naringin showed different diastereomeric ratio and 2S-prunin appeared only in immature grapefruit. Marmalade was also examined by chiral CE. Its major flavanones corresponded to flavanone pattern of mixed sour and sweet oranges.  相似文献   

15.
A novel chiral selector, clindamycin succinate, was synthesized and first used as a chiral selector in capillary electrophoresis (CE). The chiral resolution ability of this kind of clindamycin derivation was studied by CE using some racemic drugs as model analytes. From the experimental results, it was found that both resolution and selectivity of the selector were dependent on the following parameters: concentration of chiral selectors, pH of the running buffer, temperature of the capillary column, applied voltage and organic modifier used. The results show that the chiral selector possesses high resolution toward some racemic drugs, including ofloxacin, chlorphenamine, tryptophan, propranolol, sotalol and metoprolol. Excellent chiral resolution of these tested drugs was achieved under the optimal conditions of 50 mM clindamycin succinate, 10% MeOH v/v, 50 mM Tris buffer, pH 4.0, at 22 kV and 20 °C within 25 min.  相似文献   

16.
(+)-(18-crown-6)-tetracarboxylic acid (18C6H4) has been known as a highly efficient chiral selector for resolving primary amine enantiomers in capillary electrophoresis (CE). We investigated the chiral separation of gemifloxacin using 18C6H4 in analytical counter-current chromatography (CCC). The separation conditions for CE, including the binding constant, pH, and run buffer constituents, provided a helpful guideline for chiral CCC. A successful separation of gemifloxacin enantiomers could be achieved using a two-phase solvent system composed of 1-butanol-ethyl-acetate-bis(2-hydroxyethyl)aminotris(hydroxymethyl)methane acetate buffer with a small amount of 18C6H4. The hydrophobicity of the solvent system and the 18C6H4 concentration were varied to optimize the chiral separation.  相似文献   

17.
Chen J  Du Y  Zhu F  Chen B 《Journal of chromatography. A》2010,1217(45):7158-7163
Several chiral reagents including cyclodextrins (CDs) and derivatives, crown ethers, proteins, chiral surfactants and polymers have been involved in dual selector systems for enantioseparation of a series of chiral compounds by capillary electrophoresis (CE). In comparison to the chiral reagents above-mentioned, there is no report concerning the use of polysaccharides in dual chiral CE system. In this paper we first investigate the enantioselectivity of polysaccharide-based dual selector systems towards some chiral drugs. During our recent work, glycogen belonging to the class of branched polysaccharides has been used as a novel chiral selector in CE. In this study, three glycogen-based dual chiral CE systems have been established for enantiomeric separations of several racemic basic drugs consisting of duloxetine, cetirizine, citalopram, sulconazole, laudanosine, amlodipine, propranolol, atenolol and nefopam. These three dual systems combined glycogen (neutral polysaccharide) with chondroitin sulfate A (CSA, ionic polysaccharide), β-CD and HP-β-CD, respectively. It was found that the dual system of glycogen/CSA exhibited good enantioselective properties toward the tested drugs. More importantly, compared to the single selector systems, synergistic effect was observed when glycogen was used with CSA for most of the analytes. This indicated the enhancement of enantioseparation observed for these analytes in glycogen/CSA system might be due to some favorable interaction effects between glycogen and CSA. Moreover, in order to evaluate the stereoselectivity of glycogen/CSA, the influences of buffer pH and selector concentration on enantioseparation of the studied drugs were also investigated.  相似文献   

18.
Simó C  Rizzi A  Barbas C  Cifuentes A 《Electrophoresis》2005,26(7-8):1432-1441
In this work, the development of a new chiral capillary electrophoresis-mass spectrometry (CE-MS) method to separate D- and L-amino acids is shown. On-line coupling between CE and MS is established through an electrospray-coaxial sheath flow interface. Enantiomer separation is achieved by using a cheap, nonvolatile, chiral selector as beta-cyclodextrin in the background electrolyte (BGE) together with a physically coated capillary that is aimed to prevent contamination of the electrospray. The capillary coating is simple and easy to obtain as it only requires flushing of the capillary with a polymer aqueous solution for 3 min. Optimization of CE parameters (pH of BGE, type and concentration of chiral selector, and capillary inner diameter) and electrospray-MS parameters (nature and flow rate of the sheath liquid, nebulizer pressure) is carried out. Two different derivatization protocols of amino acids using dansyl chloride (DNS) and fluorescein isothiocyanate (FITC) are compared in terms of MS sensitivity and chiral resolution. Under optimum CE-MS conditions it is observed that the MS sensitivity obtained for FITC- and DNS-amino acids is similar (with limit of detection (LOD) in the microM range, corresponding to amounts injected in the fmol range) while chiral resolution is better for FITC-amino acids. The optimized method is demonstrated to provide the simultaneous analysis of 15 selected amino acids (i.e., FITC-D/L-Asp, -Glu, -Ser, -Asn, -Ala, -Pro, -Arg, and FITC-gamma-aminobutyric acid (GABA) in a single chiral CE-MS run, corresponding to the main amino acids that can be found in orange. Moreover, as a result of the high resolution achieved, it is possible to detect down to 2% of D-Asp in the presence of 98% of L-Asp. The good possibilities of chiral CE-MS in food analysis are corroborated through the detection of the main amino acids in a commercial orange juice (i.e., FITC-L-Asp, -Glu, -Ser, -Asn, -Pro, -Arg, and the nonchiral FITC-GABA) as well as the determination of the fraudulent addition of synthetic amino acids (containing D- and L-forms) to a fresh orange juice.  相似文献   

19.
卡那霉素作为手性选择剂的毛细管电泳手性药物分离研究   总被引:3,自引:0,他引:3  
建立了一种以天然易得的卡那霉素为手性添加剂,用毛细管区带电泳法快速分离市售对乙肝有良好治疗效果的药物联苯双脂衍生物的方法,拓宽了毛细管电泳中手性选择剂的范围,通过实验研究了卡那霉素、甲醇 含量PH值,磷酸盐缓冲体系和硼硝缓冲体系对手性分离的影响,以及三种有机溶剂(甲醇、乙晴、异丙醇)添加剂对手性分离的影响,结果表明,在含有3%卡那霉素,30mol/L,硼砂缓冲体系(PH=8.0)添加30%异丙醇是最佳的分离条件。  相似文献   

20.
Na N  Hu Y  Ouyang J  Baeyens WR  Delanghe JR  Taes YE  Xie M  Chen H  Yang Y 《Talanta》2006,69(4):866-872
A new strategy for chiral separation by capillary electrophoresis employing modified-nanoparticles as chiral selector is described for clenbuterol analysis. Nanoparticles modified with β-cyclodextrin (β-CD) form a large surface area platform to serve as a pseudostationary chiral phase, which can be applied for the enhancement of the enantioseparation. The application of four kinds of nanoparticles was investigated (multi-walled nanotubes (MWNTs), polystyrene (PS), TiO2 and Al2O3) modified with single layer β-CD as chiral selector in the enantioseparation of clenbuterol by capillary electrophoresis (CE). Successful clenbuterol enantioseparation could be achieved with the β-CD-modified MWNTs as chiral selector. X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR) confirmed the β-CD modification of the nanoparticles. The effects of nanoparticles, surfactant, chiral selector (β-CD) and run buffer were studied in relation to the enantiomeric separation of clenbuterol. This study opens attractive perspectives for the use of modified nanoparticles for chiral separational purposes in CE.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号