首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Liang D  Song L  Chen Z  Chu B 《Electrophoresis》2001,22(10):1997-2003
The effect of the separation medium in capillary electrophoresis consisting of a low-molecular-mass poly(N,N-dimethylacrylamide) (PDMA) solution on the DNA separation by adding a small amount of montmorillonite clay into the polymer matrix is presented. On the separation of the pBR322/HaeIII digest, both the resolution and the efficiency were increased by adding 2.5-5.0 x 10(-5) g/mL clay into the 5% w/v PDMA with a molecular mass of only 100 K. Moreover, there was no increase in the migration time of DNA fragments. Similar results were observed by using a C-terminated pGEM-3Zf(+) sequencing DNA sample in a sequencing buffer. Experimental data also showed that the addition of clay increased the viscosity of the polymer solution. We attribute this effect to the structural change of the polymer matrix caused by the exfoliated clay sheets, whereby the thin clay sheets function like a "dynamic cross-linking plate" for the PDMA chains and effectively increase the apparent molecular mass of PDMA.  相似文献   

2.
The possibility of using polymer mixtures with different chemical compositions as a DNA sequencing matrix by capillary electrophoresis (CE) has been exploited. Polyacrylamide (PAM, 2.5%, w/v) having a molecular mass of 2.2 x 10(6) has been mixed with poly(N,N-dimethylacrylamide) (PDMA) having molecular masses of 8000, 470000 and 2.1 x 10(6) at concentrations of 0.2, 0.5 and 1% (w/v). Unlike polymer mixtures of the same polymer with different molecular masses, the use of polymer mixtures with different chemical compositions encounters an incompatibility problem. It was found that the incompatibility increased with increasing PDMA molecular mass and PDMA concentration, which resulted in decreased efficiency in DNA sequencing. Also, the incompatibility had a more pronounced effect on the efficiency as the base number was increased. However, by choosing a low-molecular-mass PDMA of 8000 and a low concentration of 0.2% (w/v), the incompatibility of PAM and PDMA has been alleviated. At the same time, the advantage of using polymer mixtures revealed a higher efficiency for such a polymer mixture when compared with PAM. The mixture also endowed the separation medium with a dynamic coating ability. An efficiency of over 10 x 10(6) theoretical plates per meter has been achieved by using the bare capillaries without the additional chemical coating step.  相似文献   

3.
The mixtures of two polymers, poly (N,N-dimethylacrylamide) (PDMA) and polyvinylpyrrolidone (PVP) were synthesized and used as the separation medium for double-stranded and single-stranded DNA fragments by capillary electrophoresis with UV detector. On optimal conditions, 2%w/v PDMA 2%w/v PVP can be used to separate the doublet 123/124bp in pBR322/Hae Ⅲ Markers.  相似文献   

4.
Song L  Liang D  Fang D  Chu B 《Electrophoresis》2001,22(10):1987-1996
Poly(N,N-dimethylacrylamide) (PDMA) with a molecular mass of 5.2 x 10(6) g/mol has been synthesized and used in DNA sequencing analysis by capillary electrophoresis (CE). A systematic investigation is presented on the effects of different separation conditions, such as injection amount, capillary inner diameter, polymer concentration, effective separation length, electric field and temperature, on the resolution. DNA sequencing up to 800 bases with a resolution (R) limit of 0.5 (and 1,000 bases with a resolution limit of 0.3) and a migration time of 96 min was achieved by using 2.5% w/v polymer, 150 V/cm separation electric field, and 60 cm effective separation length at room temperature on a DNA sample prepared with FAM-labeled--21M13 forward primer on pGEM3Zf(+) and terminated with ddCTP. Ultrafast and fast DNA sequencing up to 420 and 590 bases (R > or = 0.5) were also achieved by using 3% w/v polymer and 40 cm effective separation length with a separation electric field of 525 and 300 V/cm, and a migration time of 12.5 and 31.5 min, respectively. PDMA has low viscosity, long shelf life and dynamic coating ability to the glass surface. The unique properties of PDMA make it a very good candidate as a separation medium for large-scale DNA sequencing by capillary array electrophoresis (CAE).  相似文献   

5.
Gao F  Tie C  Zhang XX  Niu Z  He X  Ma Y 《Journal of chromatography. A》2011,1218(20):3037-3041
The separation and sequencing of DNA are the main objectives of the Human Genome Project, and this project has also been very useful for gene analysis and disease diagnosis. Capillary electrophoresis (CE) is one of the most common techniques for the separation and analysis of DNA. DNA separations are usually achieved using capillary gel electrophoresis (CGE) mode, in which polymer gel is packed into the capillary. Compared with a traditional CGE matrix, a hydrophilic polymer matrix, which can be adsorb by the capillary wall has numerous advantages, including stability, reproducibility and ease of automation. Various water-soluble additives, such as linear poly(acrylamide) (PAA) and poly(N,N-dimethylacrylamide) (PDMA), have been employed as media. In this study, different star-shaped PDMA polymers were designed and synthesized to achieve lower polymer solution viscosity. DNA separations with these polymers avoid the disadvantages of high viscosity and long separation time while maintaining high resolution (10 bp between 271 bp and 281 bp). The influences of the polymer concentration and structure on DNA separation were also determined in this study; higher polymer concentration yielded better separation performance, and star-like polymers were superior to linear polymers. This work indicates that modification of the polymer structure is a potential strategy for optimizing DNA separation.  相似文献   

6.
Zhou D  Wang Y  Zhang W  Yang R  Shi R 《Electrophoresis》2007,28(7):1072-1080
In order to further improve ssDNA sequencing performances using quasi-interpenetrating network (quasi-IPN) as a matrix composed of linear polyacrylamide (LPA) with lower viscosity-average molecular mass (3.3 MDa) and poly(N,N-dimethylacrylamide) (PDMA), gold nanoparticles (GNPs) were prepared and added into this quasi-IPN to form polymer/metal composite sieving matrices. The studies of intrinsic viscosity and differential scanning calorimetry (DSC) on quasi-IPN and quasi-IPN/GNPs indicate that there were interactions between GNPs and polymer chains. The sequencing performances on ssDNA using quasi-IPN and quasi-IPN/GNPs (with different GNPs concentrations) as sieving matrices were studied and compared by CE at different temperatures. The results show that resolutions of quasi-IPN/GNPs were higher than those of quasi-IPN without GNPs and approximated those of quasi-IPN composed of LPA with higher MW (6.5 MDa) and PDMA without GNPs in the bare fused-silica capillaries. Furthermore, the sequencing time of quasi-IPN/GNPs was shorter than that of quasi-IPN under the same sequencing conditions. The influences of GNPs and sequencing temperature on the sequencing performances of ssDNA were also discussed. The separation reproducibility of quasi-IPN/GNPs solution was excellent and its shelf life was more than 8 months.  相似文献   

7.
The novel polymer matrices reported here are low-viscosity sieving media for DNA capillary electrophoresis. This new family of matrices comprises copolymers of N,N-dimethylacrylamide with different monomers which increase polymer hydrophilicity. All these new copolymers self-coat on fused-silica capillaries. Resolution, peak spacing and peak width were the parameters taken into account to assess the influence of polymer structure on separation selectivity and efficiency. This work demonstrates that the performance of polydimethylacrylamide (PDMA) can be improved through copolymerization with hydrophilic monomers. The improvement is related to the efficiency parameter. The new copolymers, due to their low viscosity high sieving capacity and ability to suppress EOF, represent a better alternative to PDMA and are suitable replaceable matrices for capillary and microchip electrophoresis.  相似文献   

8.
Read length in DNA sequencing by capillary electrophoresis at elevated temperatures is shown to be greatly affected by the extent of hydrophobicity of the polymer separation matrix. At column temperatures of up to 80 degrees C, hydrophilic linear polyacrylamide (LPA) provides superior read length and separation speed compared to poly(N,N-dimethylacrylamide) (PDMA) and a 70:30 copolymer of N,N-dimethylacrylamide and N,N-diethylacrylamide (PDEA30). DNA-polymer and polymer intramolecular interactions are presumed to be a major cause of band broadening and the subsequent loss of separation efficiency with the more hydrophobic polymers at higher column temperatures. With LPA, these interactions were reduced, and a read length of 1000 bases at an optimum temperature of 70 degrees -75 degrees C was achieved in less than 59 min. By comparison, PDMA produced a read length of roughly 800 bases at 50 degrees C, which was close to the read length attained in LPA at the same temperature; however, the migration time was approximately 20% longer, mainly because of the higher polymer concentration required. At 60 degrees C, the maximum read length was 850 bases for PDMA, while at higher temperatures, read lengths for this polymer were substantially lower. With the copolymer DEA30, read length was 650 bases at the optimum temperature of 50 degrees C. Molecular masses of these polymers were determined by tandem gel permeation chromatography-multiangle laser light scattering method (GPC-MALLS). The results indicate that for long read, rapid DNA sequencing and analysis, hydrophilic polymers such as LPA provide the best overall performance.  相似文献   

9.
Quasi‐interpenetrating network (quasi‐IPN) of linear polyacrylamide (LPA) with low molecular mass and poly(N,N‐dimethylacrylamide) (PDMA), which is shown to uniquely combine the superior sieving ability of LPA with the coating ability of PDMA, has been synthesized for application in dsDNA and basic protein separation by CE. The performance of quasi‐IPN on dsDNA separation was determined by polymer concentration, electric field strength, LPA molecular masses and different acrylamide (AM) to N,N‐dimethylacrylamide (DMA) ratio. The results showed that all fragments in Φ×174/HaeIII digest were achieved with a 30 cm effective capillary length at –6 kV at an appropriate polymer solution concentration in bare silica capillaries. Furthermore, EOF measurement results showed that quasi‐IPN exhibited good capillary coating ability, via adsorption from aqueous solution, efficiently suppressing EOF. The effect of the buffer pH values on the separation of basic proteins was investigated in detail. The separation efficiencies and analysis reproducibility demonstrated the good potentiality of quasi‐IPN matrix for suppressing the adsorption of basic proteins onto the silica capillary wall. In addition, when quasi‐IPN was used both as sieving matrix and dynamic coating in bare silica capillaries, higher peak separation efficiencies, and better migration time reproducibility were obtained.  相似文献   

10.
To elucidate the impact of matrix chemical and physical properties on DNA sequencing separations by capillary electrophoresis (CE), we have synthesized, characterized and tested a controlled set of different polymer formulations for this application. Homopolymers of acrylamide and N,N-dimethylacrylamide (DMA) and copolymers of DMA and N,N-diethylacrylamide (DEA) were synthesized by free radical polymerization and purified. Polymer molar mass distributions were characterized by tandem gel permeation chromatography - laser light scattering. Polymers with different chemical compositions and similar molar mass distributions were selected and employed at the same concentration so that the variables of comparison between them were hydrophobicity and average coil size in aqueous solution. We find that the low-shear viscosities of 7% w/v polymer solutions decrease by orders of magnitude with increasing polymer hydrophobicity, while hydrophilic polymers exhibit more pronounced reductions in viscosity with increased shear. The performance of the different matrices for DNA sequencing was compared with the same sample under identical CE conditions. The longest read length was produced with linear polyacrylamide (LPA) while linear poly-N,N-dimethylacrylamide (PDMA) gave approximately 100 fewer readable bases. Read lengths with DMA/DEA copolymers were lower, and decreased with increasing DEA content. This study highlights the importance of polymer hydrophilicity for high-performance DNA sequencing matrices, through the formation of robust, highly-entangled polymer networks and the minimization of hydrophobic interactions between polymers and fluorescently-labeled DNA molecules. However, the results also show that more hydrophobic matrices offer much lower viscosities, enabling easier microchannel loading at low applied pressures.  相似文献   

11.
The large scale motions of poly(N,N-dimethylacrylamide) chains randomly labeled with pyrene (Py-PDMA) were monitored by steady-state and time-resolved fluorescence in semidilute solutions of naked PDMA in acetone and DMF for polymer concentrations ranging from 0 to 550 g/L. Although increasing the polymer concentration of the solution led to a decrease of the mobility of the chromophore attached onto the PDMA backbone, this reduction was rather modest when compared to the large increase of the macroscopic viscosity. This result indicated that locally, the monomer constituting the chains experienced freedom of movement despite the high solution viscosity. The restricted mobility of the chromophore was characterized by the number of monomers occupying the volume probed by the excited chromophore during its lifetime, referred to as a fluorescence "blob". The number of monomers constituting a fluorescence blob, N(F)(-)(blob), and the volume of a fluorescence blob, V(F)(-)(blob), were found to decrease as the polymer concentration of the solution increased, reflecting the decreased mobility experienced by the chromophore. In DMF, the radius of an F-blob was found to scale as N(nu)(F)(-)blob, where nu equaled 0.66 +/- 0.03, very close to the expected value of the Flory exponent of 0.6 for a polymer in a good solvent. The combined knowledge of how N(F)(-)(blob) varies with the fluorescence lifetime of the chromophore and the coil density of the polymer was used to propose a new means of studying coil-to-globule transitions with potential implications for predicting the rate of protein folding.  相似文献   

12.
Poor compatibility was the major drawback of polymer mixtures when used as DNA separation media. Using poly(ethylene oxide)‐b‐poly(N, N‐dimethylacrylamide) (PEO44b‐PDMA88) and PEO (Mw: 1.3 MDa) as an example, we demonstrated the concept that the compatibility was significantly improved when mixing a homopolymer with its copolymer. Laser light scattering indicated that the major interaction between PEO and PEO‐b‐PDMA in dilute solution was the weak hydrodynamic interaction, which showed almost no effect on the viscosity and the static scattering pattern. In semidilute or concentrated solution, viscosity measurement also suggested good compatibility between the two components. When tested as DNA separation medium by CE, the viscosity of the mixture was extremely low, only 5 cP for 5.0 m/v% PEO‐b‐PDMA+0.1 m/v% PEO at 25°C. The performance on DNA separation could be tuned by varying the concentration of each component as well as the component ratio. Good separation on both dsDNA and ssDNA was achieved.  相似文献   

13.
Song L  Liu T  Liang D  Fang D  Chu B 《Electrophoresis》2001,22(17):3688-3698
Mixtures of two polymers with totally different chemical structures, polyacrylamide and polyvinylpyrrolidone (PVP) have been successfully used for double-stranded DNA separation. By polymerization of acrylamide in a matrix of PVP solution, the incompatibility of these two polymers was suppressed. Laser light scattering (LLS) studies showed that highly entangled interpenetrating networks were formed in the solution. Further systematic investigation showed that double-stranded DNA separation was very good in these interpenetrating networks. With a concentration combination of as low as 2% w/v PVP (weight-average molecular mass Mr = 1 x 10(6) g/mol) + 1% w/v polyacrylamide (Mr = 4 x 10(5) g/mol), the 22 fragments in pBR322/HaeIII DNA, including the doublet of 123/124 bp, have been successfully separated within 6.5 min. Under the same separation conditions, similar resolution could only be achieved by using polyacrylamide (Mr = 4 x 10(5) g/mol) with concentrations higher than 6% w/v and could not be achieved by using only PVP (Mr = 1 x 10(6) g/mol) with a concentration as high as 15% w/v. It is noted that the interpenetrating network formed by 2% PVP and 1% polyacrylamide has a very low viscosity and can dynamically coat the inner wall of a fused-silica capillary. The separation reached an efficiency of more than 10(7) theoretical plate numbers/m and a reproducibility of less than 1% relative standard deviation of migration time in a total of seven runs. The interpenetrating network could stabilize polymer chain entanglements. Consequently, the separation speed was increased while retaining resolution.  相似文献   

14.
王前许旭  戴立信 《中国化学》2006,24(12):1766-1772
Quasi-interpenetrating network of polyacrylamide (PAA) and polyvinylpyrrolidone (PVP) had been successfully used for single-base resolution of double-stranded DNA (0.76 for 123 bp/124 bp) and single-stranded DNA fragments (0.97 for 123 b/124 b) with UV detection. This quasi-IPN (interpenetrating network) sieving matrix showed low viscosity (23.5 mPa·s at 25 ℃) and decreased with increasing temperature. This polymer also exhibited dynamically coating capacity and could be used in the uncoated capillary. The effects of temperature and electric field strength on the DNA separation of quasi-IPN matrix were also investigated and found that the temperature and electric field strength could markedly affected the mobility behavior of DNA fragments. This polymer matrix has also applied to separate the bigger DNA fragments by capillary electrophoresis with UV detection. Under the denaturing conditions, this matrix separated the samples with last fragment of 1353 base in 40 rain, in which the doublet of 309/310 base was partial separated and the resolution was 0.88.  相似文献   

15.
A replaceable polymer matrix, based on the novel monomer N-hydroxyethylacrylamide (HEA), has been synthesized for application in DNA separation by microchannel electrophoresis. The monomer was found by micellar electrokinetic chromatography analysis of monomer partitioning between water and 1-octanol to be more hydrophilic than acrylamide and N,N-dimethylacrylamide. Polymers were synthesized by free radical polymerization in aqueous solution. The weight-average molar mass of purified polymer was characterized by tandem gel permeation chromatography-multiangle laser light scattering. The steady-shear rheological behavior of the novel DNA sequencing matrix was also characterized, and it was found that the viscosity of the novel matrix decreases by more than 2 orders of magnitude as the shear rate is increased from 0.1 to 1000 s(-1). Moreover, in the shear-thinning region, the rate of change of matrix viscosity with shear rate increases with increasing polymer concentration. Poly-N-hydroxyethylacrylamide (PHEA) exhibits good capillary-coating ability, via adsorption from aqueous solution, efficiently suppressing electroosmotic flow (EOF) in a manner comparable to that of poly-N,N-dimethylacrylamide. Under DNA sequencing conditions, adsorptive PHEA coatings proved to be stable and to maintain negligible EOF for over 600 h of electrophoresis. Resolution of DNA sequencing fragments, particularly fragments > 500 bases, in PHEA matrices generally improves with increasing polymer concentration and decreasing electric field strength. When PHEA is used both as a separation matrix and as a dynamic coating in bare silica capillaries, the matrix can resolve over 620 bases of contiguous DNA sequence within 3 h. These results demonstrate the good potential of PHEA matrices for high-throughput DNA analysis by microchannel electrophoresis.  相似文献   

16.
Liang D  Song L  Quesada MA  Tian Z  Studier FW  Chu B 《Electrophoresis》2000,21(17):3600-3608
A new method to introduce the concentration gradient into the capillary has been developed and its application to DNA capillary electrophoresis is presented. The concentration gradient produced by mixing 5% w/v polyacrylamide-co-poly(N-dimethylacrylamide) (PAM-co-PDMA) solution and 1 x Tris/N-tris(hydroxymethyl)methyl-3-amino-propanesulfonic acid/EDTA (TT) + 5 M urea buffer was successfully achieved by using two programmable syringe pumps with strict control of dead volume, flow rate, and pressure balance. This method has the advantages of high stability, reproducibility, and versatility. The column with concentration gradient greatly improved the resolution, especially for the large DNA fragments, due to a decrease in band width broadening with time. A column containing 2-4% w/v gradient in four steps had a longer read length, shorter separation time and better resolution (after 380 base) than that of 4% w/v single concentration polymer solution. The number of steps in the gradient had almost no effect on the performance. The change in the average concentration by relocating the position of the same step gradient, i.e., a combination of different low concentration to high concentration polymer solution ratios, resulted in a different migration time, read length and resolution.  相似文献   

17.
Copolymers of acrylamide (AM) and N,N-dimethylacrylamide (DMA) with AM to DMA molar ratios of 3:1, 2:1 and 1:1 and molecular weights of about 2.2 MDa were synthesized. The polymers were tested as separation media in DNA sequencing analysis by capillary electrophoresis (CE). The dynamic coating ability of polydimethylacrylamide (PDMA) and the hydrophilicity of polyacrylamide (PAM) have been successfully combined in these random copolymers. A separation efficiency of over 10 million theoretical plates per meter has been reached by using the bare capillaries without the additional polymer coating step. Under optimized separation conditions for longer read length DNA sequencing, the separation ability of the copolymers decreased with decreasing AM to DMA molar ratio from 3:1, 2:1 and 1:1. In comparison with PAM, the copolymer with a 3:1 AM:DMA ratio showed a higher separation efficiency. By using a 2.5% w/v copolymer with 3:1 AM:DMA ratio, one base resolution of 0.55 up to 699 bases and 0.30 up to 963 bases have been achieved in about 80 min at ambient temperatures.  相似文献   

18.
We present the polymer poly-N-hydroxyethylacrylamide (PHEA) (polyDuramide) as a novel, hydrophilic, adsorbed capillary coating for electrophoretic protein analysis. Preparation of the PHEA coating requires a simple and fast (30 min) protocol that can be easily automated in capillary electrophoresis instruments. Over the pH range of 3-8.4, the PHEA coating is shown to reduce electroosmotic flow (EOF) by about 2 orders of magnitude compared to the bare silica capillary. In a systematic comparative study, the adsorbed PHEA coating exhibited minimal interactions with both acidic and basic proteins, providing efficient protein separations with excellent reproducibility on par with a covalent polyacrylamide coating. Hydrophobic interactions between proteins and a relatively hydrophobic poly-N,N-dimethylacrylamide (PDMA) adsorbed coating, on the other hand, adversely affected separation reproducibility and efficiency. Under both acidic and basic buffer conditions, the adsorbed PHEA coating produced an EOF suppression performance comparable to that of covalent polyacrylamide coating and superior to that of adsorbed PDMA coating. The protein separation performance in PHEA-coated capillaries was retained for 275 consecutive protein separation runs at pH 8.4, and for more than 800 runs at pH 4.4. The unique and novel combination of hydrophilicity and adsorptive coating ability of PHEA makes it a suitable wall coating for automated microscale analysis of proteins by capillary array systems.  相似文献   

19.
Zhou D  Wang Y  Yang R  Zhang W  Shi R 《Electrophoresis》2007,28(17):2998-3007
Gold nanoparticles (GNPs) with particle sizes of about 20, 40, and 60 nm were prepared and added into a quasi-interpenetrating network (quasi-IPN) composed of linear polyacrylamide (LPA) with different viscosity-average molecular masses of 1.5, 3.3, and 6.5 MDa and poly-N,N-dimethylacrylamide (PDMA) to form polymer/metal composite matrices, respectively. These novel matrices could improve ssDNA sequencing performances due to interactions between GNPs and polymer chains and the formation of physical cross-linking points as demonstrated by intrinsic viscosities and glass transition temperatures. The effects of the parameters in relation to quasi-IPN/GNPs matrices, such as GNP contents, GNP particle sizes, LPA molecular masses, and solution concentrations, on ssDNA sequencing performances were studied. In the presence of GNPs, the separation had the advantages of high resolution, speediness, excellent reproducibility, long shelf life and easy automation. Therefore, less viscous matrix solutions (with moderate size GNPs) due to lower solution concentration and lower-molecular-mass LPA could be used to replace more viscous solutions (without GNPs) due to higher solution concentration or higher-molecular-mass LPA to separate DNA, while the sieving performances were approximate even higher, which helped to achieve full automation especial for capillary array electrophoresis (CAE) and microchip electrophoresis (MCE).  相似文献   

20.
Two novel double hydrophilic multiblock copolymers of N,N-dimethylacrylamide and N-isopropylacrylamide, m-PDMAp-PNIPAMq, with varying degrees of polymerization (DPs) for PDMA and PNIPAM sequences (p and q) were synthesized via consecutive reversible addition-fragmentation chain transfer (RAFT) polymerizations using polytrithiocarbonate (1) as the chain transfer agent (Scheme 1), where PDMA is poly(N,N-dimethylacrylamide) and PNIPAM is poly(N-isopropylacrylamide). The DPs of PDMA and PNIPAM sequences were determined by 1H NMR, and the block numbers, i.e., number of PDMAp-PNIPAMq sequences (n), were obtained by comparing the molecular weights of multiblock copolymers to that of cleaved products as determined by gel permeation chromatography (GPC). m-PDMA42-PNIPAM37 and m-PDMA105-PNIPAM106 multiblock copolymers possess number-average molecular weights (Mn) of 4.62x10(4) and 9.53x10(4), respectively, and the polydispersities (Mw/Mn) are typically around 1.5. Block numbers of the obtained multiblock copolymers are ca. 4, which are considerably lower than the numbers of trithiocarbonate moieties per chain of 1 (approximately 20) and m-PDMAp precursors (approximately 6-7). PDMA homopolymer is water soluble to 100 degrees C, while PNIPAM has been well known to exhibit a lower critical solution temperature (LCST) at ca. 32 degrees C. In aqueous solution, m-PDMA42-PNIPAM37 and m-PDMA105-PNIPAM106 multiblock copolymers molecularly dissolve at room temperature, and their thermo-induced collapse and aggregation properties were characterized in detail by a combination of optical transmittance, fluorescence probe measurements, laser light scattering (LLS), and micro-differential scanning calorimetry (micro-DSC). It was found that chain lengths of PDMA and PNIPAM sequences exert dramatic effects on their aggregation behavior. m-PDMA105-PNIPAM106 multiblock copolymer behaves as protein-like polymers and exhibits intramolecular collapse upon heating, forming unimolecular flower-like micelles above the thermal phase transition temperature. On the other hand, m-PDMA42-PNIPAM37 multiblock copolymer exhibits collapse and intermolecular aggregation, forming associated multimolecular micelles at elevated temperatures. The intriguing aggregation behavior of this novel type of double hydrophilic multiblock copolymers argues well for their potential applications in many fields such as biomaterials and biomedicines.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号