首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Liquid- or gas-phase standards can be used for the analysis of VOCs in air. Once the accuracy is secured in the standard preparation stage, the use of gas-phase standard should be more reliable with the least matrix effect. However, it is not difficult to find that the liquid-phase standard is used more preferably in many laboratories for several reasons (e.g., low expense, easy handling, etc.). As such, one needs to accurately evaluate any possible bias stemming from the use of different standard phases. To this end, standards for 8 VOCs consisting of 4 aromatic compounds (benzene (B), toluene (T), styrene (S) and p-xylene (p-X)) and 4 others (methyl ethyl ketone (MEK), methyl isobutyl ketone (MIBK), butyl acetate (BuAc), and isobutyl alcohol (i-BuAl)) were prepared in both liquid and gas phases. Each standard was analyzed by the initial collection on the adsorption tube and by the combined application of thermal-desorption–gas chromatography–mass spectrometry (TD/GC/MS). The results indicated that experimental bias between the two phases, if expressed in terms of percent difference (PD), was very low in many target VOCs (B (1.09%), T (2.41%), p-X (3.64%), MEK (6.76%), and MIBK (0.17%)), while it was not in some targets (e.g., >10%: e.g., S, i-BuAl, and BuAc). In an ancillary experiment, biases were evaluated further by (1) calibrating gaseous samples against liquid phase standard and via (2) comparison between two different types of gas phase standards. In conclusion, treatment of different standards (e.g., between the same or different phases) will inevitably induce biases in most VOCs, although certain volatiles (e.g., benzene, MIBK, etc.) are virtually unaffected by such variables in a practical sense.  相似文献   

2.
The combined use of sorbent tubes (ST) and thermal desorption (TD) has become the common practice for the trace-level analysis of gaseous volatile organic compounds (VOCs). In this research, the potential bias in VOC analysis due to the solvent introduced into the system as a liquid standard (LS) is examined in three stages by analyzing LSs of 19 VOCs in methanol solvent against a three-bed ST (Tenax TA, Carbopack B, and Carboxen 1000). In experimental stage 1, LS made at four concentration levels (between 10 and 150 ng μL?1) were each analyzed at four injection volumes (1, 2, 5, and 10 μL) based on a vaporization method. In experimental stage 2, calibration was also conducted by direct injection over an extended concentration range at two volumes, 1 and 10 μL. In experimental stage 3, the response factors (RF) of a single analyte mass were compared across the four injection volumes and between two injection methods. These results were analyzed to explore the complex relationship between variables such as LS volume, target/solvent chemical type, sorbent strength, and prepurge condition. There was no change in the ST/TD performance up to 2 μL of LS. However, as the injection volume increased up to 5 μL, a notable shift in RF and retention time occurred (e.g., for benzene and methyl ethyl ketone). At the maximum injection volume (10 μL), a significant reduction in sensitivity is evident for all compounds, e.g., 50 % drops relative to 1 μL injection. As such, the TD performance tends to deteriorate with increasing volume of methanol initially loaded on the ST. Although the dominant fraction of solvent was removed by two prepurge steps, residue caught in the strong sorbent fraction is still found to exert an effect on the subsequent analysis, e.g., delayed retention, sensitivity reduction, or disappearance of certain compounds.  相似文献   

3.
建立用气袋法收集整册印刷品释放的挥发性有机化合物,热解析-气相色谱法检测总挥发性有机化合物(TVOC)的方法。将印刷品样品置入充满高纯氮气的密封PVF采样袋中,在35℃下放置12 h后,用采样器串联Tenax-TA采样管和采样袋,让袋内气体通过采样管,样品释放出的有机化合物被吸附到采样管的吸附剂上。用热解析-气相色谱法测试采样管中挥发性有机化合物的含量,其中苯、甲苯、邻二甲苯、间二甲苯、对二甲苯、乙苯、乙酸丁酯、苯乙烯和正十一烷按外标法定量,其它物质按甲苯标准曲线定量。该方法的加标回收率为74.4%~91.1%,测定结果的相对标准偏差不大于10%(n=9)。该方法的样品采集更贴近印刷品的实际生活场景,可以为评价印刷品挥发性有机物释放对人体健康的影响提供数据基础,为相关评价提供新思路。  相似文献   

4.
An automated sampling and enrichment apparatus coupled with a gas chromatography/mass spectrometry (GC/MS) technique was constructed for the analysis of ambient volatile organic compounds (VOCs). A sorbent trap was built within the system to perform on-line enrichment and thermal desorption of VOCs onto GC/MS. In order to improve analytical precision, calibration accuracy, and to safe-guard the long-term stability of this system, a mechanism to allow on-line internal standard (I.S.) addition to the air sample stream was configured within the sampling and enrichment apparatus. A sub-ppm (v/v) level standard gas mixture containing 1,4-fluorobenzene, chloropentafluorobenzene, 1-bromo-4-fluorobenzene was prepared from their pure forms. A minute amount of this I.S. gas was volumetrically mixed into the sample stream at the time of on-line enrichment of the air sample to compensate for measurement uncertainties. To assess the performance of this VOC GC/MS system, a gas mixture containing numerous VOCs at sub-ppb (v/v) level served as the ambient air sample. Various internal standard methods based on total ion count (TIC) and selective ion monitoring (SIM) modes were attempted to assess the improvement in analytical precision and accuracy. Precision was improved from 7-8% RSD without I.S. to 2-3% with I.S. for the 14 target VOCs. Uncertainties in the calibration curves were also improved with the adoption of I.S. by reducing the relative standard deviation of the slope (Sm%) by an average a factor of 4, and intercept (Sb%) by a factor of 2 for the 14 target VOCs.  相似文献   

5.
马慧莲  金静  李云  陈吉平 《色谱》2017,35(10):1094-1099
建立了固相吸附热脱附-气相色谱-质谱(TD-GC-MS)综合筛查工业源废气中挥发性有机物(VOCs)的方法。对两种型号的固相吸附管进行了比较,最终选择使用Tenax SS TD Tubes吸附管。气体样品以恒定流速通过吸附管,富集分析物,经热脱附后,用GC-MS进行检测,目标化合物以内标法定量,非目标化合物的含量以甲苯的响应系数计算。方法检出限为1.06~5.44 ng,以采样体积300 mL计算,目标化合物的检出限为0.004~0.018 mg/m~3。吸附管平均加标回收率为78.4%~89.4%,相对标准偏差为3.9%~14.4%(n=7)。应用该方法对大连市某垃圾焚烧发电厂排放的废气进行VOCs目标及非目标化合物综合筛查,共检出29种VOCs,其中仅5种VOCs为预先设定的目标化合物,另外24种为非目标化合物,5种目标化合物含量仅占所有检出物总量的26.7%。证明了工业源废气VOCs分析中非目标化合物筛查的重要性,该研究思路对完整测定工业源挥发性有机污染物分布具有一定的借鉴意义。  相似文献   

6.
冯丽丽  胡晓芳  于晓娟  张文英 《色谱》2016,34(2):209-214
采用热脱附(TD)结合气相色谱-三重四极杆串联质谱(GC-MS/MS)建立了环境空气中23种挥发性有机物(VOCs)同时检测的分析方法。空气样品通过主动采样的方式富集到装有Tenax-TA填料的热脱附管中,热解吸后在选择反应监测(SRM)模式下用GC-MS/MS进行检测,内标法定量。结果表明,23种VOCs在0.01~1 ng和1~100 ng低、高两个范围内线性关系良好,相关系数(r2)均大于0.99,方法定量限为0.00008~1 μ g/m3。加标水平为2、10和50 ng时,23种VOCs的平均回收率为77%~124%。除了最低加标水平的氯苯,相对标准偏差(RSD, n=6)均小于20%。对市内3个采样点的环境空气进行测定,其中苯、甲苯、乙苯、二甲苯、苯乙烯、1,2,4-三甲基苯和六氯丁二烯均有检出。实验证明,该TD和GC-MS/MS相结合的检测方法具有准确、可靠、灵敏度高等优点,适用于环境空气中VOCs的同时测定。  相似文献   

7.
An analytical method based on thermal desorption (TD) coupled to gas chromatography (GC) and mass spectrometry detection (MS) has been developed and validated for the determination of a wide range of odor nuisance and air-quality volatile organic compounds (VOC) in air. New generation isocyanates, isocyanato- and isothiocyanatocyclohexane, have been included for the first time as target compounds due to their high occurrence in air samples. A dynamic air sampling method to trap gas and vapor on multi-sorbent tubes using portable pump equipment has been also developed. Sorbent tubes were filled with Carbotrap (70mg), Carbopack X (100mg) and Carboxen-569 (90mg). Validation of the TD-GC-MS method showed good selectivity, sensibility and precision according to Compendium Method TO-17 (US Environment Protection Agency) criteria. Limits of detection (signal-to-noise=3, ng in tube) ranges were 0.004-0.03ng (alcanes), 0.001-0.1ng (aromatics), 0.03-14ng (aldehydes), 0.003-7ng (alcohols), 0.003-0.04ng (chlorides), 0.02-0.5ng (esters), 0.002-0.1ng (ketones), 0.01-0.53ng (terpenes), 14-97ng (amides), 0.2-10ng (isocyanates) and 0.001ng (carbon disulfide). The linear dynamic range was over 3-5 orders of magnitude, depending of the VOC. TD-GC-MS analysis was reproducible, with relative standard deviation (n=5) within 20%. VOCs breakthrough examination showed no significant losses when about 2000ng standard was prepared. In order to evaluate the performance of the developed method on real samples, several industrial and urban air samples were analysed. VOCs were found to be stable on the sorbent tubes for at least 1 week when stored at 4 degrees C.  相似文献   

8.
This paper presents a detailed study on the calibration of a thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS)-based methodology for quantification of volatile organic compounds (VOCs) in gaseous and liquid samples. For the first time, it is documented to what extent three widely encountered problems affect precise and accurate quantification, and solutions to improve calibration are proposed. The first issue deals with the limited precision in MS quantification, as exemplified by high relative standard deviations (up to 40%, n=5) on response factors of a set of 69 selected VOCs in a volatility range from 16 Pa to 85 kPa at 298 K. The addition of [(2)H(8)]toluene as an internal standard, in gaseous or liquid phase, improves this imprecision by a factor of 5. Second, the matrix in which the standard is dissolved is shown to be highly important towards calibration. Quantification of gaseous VOCs loaded on a sorbent tube using response factors obtained with liquid standards results in systematic deviations of 40-80%. Relative response factors determined by the analysis of sorbent tubes loaded with both analytes and [(2)H(8)]toluene from liquid phase are shown to offer a reliable alternative for quantification of airborne VOCs, without need for expensive and often hardly available gaseous standards. Third, a strategy is proposed involving the determination of a relative response factor being representative for a group of analytes with similar functionalities and electron impact fragmentation patterns. This group method approach indicates to be useful (RSD approximately 10%) for quantifying analytes belonging to that class but having no standards available.  相似文献   

9.
The gas–liquid partitioning behavior of major odorants (acetic acid, propionic acid, isobutyric acid, n-butyric acid, i-valeric acid, n-valeric acid, hexanoic acid, phenol, p-cresol, indole, skatole, and toluene (as a reference)) commonly found in microbially digested wastewaters was investigated by two experimental approaches. Firstly, a simple vaporization method was applied to measure the target odorants dissolved in liquid samples with the aid of sorbent tube/thermal desorption/gas chromatography/mass spectrometry. As an alternative method, an impinger-based dynamic headspace sampling method was also explored to measure the partitioning of target odorants between the gas and liquid phases with the same detection system. The relative extraction efficiency (in percent) of the odorants by dynamic headspace sampling was estimated against the calibration results derived by the vaporization method. Finally, the concentrations of the major odorants in real digested wastewater samples were also analyzed using both analytical approaches. Through a parallel application of the two experimental methods, we intended to develop an experimental approach to be able to assess the liquid-to-gas phase partitioning behavior of major odorants in a complex wastewater system. The relative sensitivity of the two methods expressed in terms of response factor ratios (RFvap/RFimp) of liquid standard calibration between vaporization and impinger-based calibrations varied widely from 981 (skatole) to 6,022 (acetic acid). Comparison of this relative sensitivity thus highlights the rather low extraction efficiency of the highly soluble and more acidic odorants from wastewater samples in dynamic headspace sampling.  相似文献   

10.
Reference introduction in thermal desorption with gas chromatography is a critical aspect. It is mostly performed by offline liquid calibration using a micro syringe to inject a liquid standard solution on the sorbent in the thermal desorption tube. This is based on the assumptions that the adsorption‐desorption process is quantitative and that no sample is lost in manipulating the tube. However, for analytical procedures involving thermal extraction of solid matrices, the adsorption‐desorption processes for sample and reference differ and the assumptions are not always fulfilled. This is explored in this work. First, issues related to the online liquid calibration were investigated. With tubes containing only quartz filters, a relative loss of over 80% was noticed for some solvents due to tube manipulation processes. Enclosing a bed of mesoporous silica as sorbent limited the losses to about 25% when samples were immediately analysed, and even better results were obtained when tubes were stored for several hours so that proper adsorption could take place. An additional sweep gas during loading boosted the transfer of analytes with recoveries above 95%. Next, an inline injection system was installed on the thermal desorber instrument. This sorbent free, independent calibration tool avoids the drawbacks of other approaches.  相似文献   

11.
An automated spray-and-trap (ST) chromatographic system was constructed for fast and efficient extraction of volatile organic compounds (VOCs) in aqueous samples with the capability to be deployed in the field for unattended continuous monitoring of surface or ground water. This system was built upon a commercial gas chromatograph with full automation capability using self-developed hardware and software. For sample analysis, fine droplets of the aqueous solution were generated in the extraction chamber by pressure expansion of a clean air stream through a spray nozzle. A portion of the VOCs distributed into the gas phase was retained by a multi-sorbent micro-trap kept at ambient temperature. Flash heating of the sorbent trap desorbed the enriched VOCs onto the gas chromatography (GC) with flame ionization detection (FID) for hydrocarbons or electron-capture detection (ECD) for halocarbons. In order to validate the performance of the ST method. it was compared with a more conventional method, i.e., a purge-and-trap (PT), by analyzing a serious of standard solutions containing benzene, toluene, ethylene. and o-, m-xylenes. Using a purge-and-trap method as a reference for complete extraction, the ST method showed less sensitivity. Extraction recoveries are in consistent with Henry's law constants. To test response time the ST-GC-ECD was periodically switched between tap and underground waters. Negligible carry-over of halogenated species and reproducibility better than 2% relative standard deviation (R.S.D.) can be achieved regardless of large concentration difference between the two sources, thus demonstrating applicability of the ST system for on-site monitoring.  相似文献   

12.
In general, volatile organic compounds in ambient air are quantified by following a well‐defined standard calibration procedure using a gas‐/liquid‐phase standard. If the liquid standard is analyzed by a thermal desorption, the solvent effect is unavoidable through the alteration of breakthrough properties or retention times. To learn more about the variables of the thermal desorption‐based analysis, the effect of pre‐purge conditions was evaluated for 18 volatile organic compounds with different types of sorbent tube materials by fixing standard volume (1 μL) and flow rate (100 mL/min). The gas phase calibration was also carried out as reference for the non‐solvent effect. A single tube filled with Tenax TA exhibited the least solvent effect with the short pre‐purge (1 min), while being subject to the breakthrough at or above 10 min pre‐purge. For a three‐bed sorbent tube with Carboxen 1000, at least 10 min of pre‐purge was needed for the compounds with a retention time close to methanol (e.g., propanal). Another three‐bed tube with Carbopack X reduced the solvent effect efficiently for a short pre‐purge (2 min) without the breakthrough. As such, the solvent effect can be adjusted by the proper control of the sorbent tube application.  相似文献   

13.
Kim KH  Choi GH  Choi YJ  Song HN  Yang HS  Oh JM 《Talanta》2006,68(5):1713-1719
In this study, the analytical bias in the measurements of reduced sulfur compounds (RSC) was investigated in terms of sorptive loss caused by the materials selected for the sample introduction. For the purpose of this study, three vacuum samplers made in the combination of different vacuuming efficiencies (e.g., rapid versus slow sampling) and different materials (i.e., Teflon versus stainless steel (SS)) were tested to evaluate the sampling recovery rate (RR) for five RSCs: H2S, CH3SH, DMS, CS2 and DMDS. To make a parallel comparison of RR, the RSC standard samples contained in one bag were transferred to another bag using each sampling system. Their relative contents between, before, and after the transfer were then evaluated between different samplers to assess the sampling bias caused by the interaction between RSC and the sampling material. In the case of the most reactive compound, H2S, the sampling loss from the SS inlet line amounted to as high as 45%, while that for the Teflon counterpart was almost insignificant. When the sampling time was arbitrarily elongated (i.e., use of a slow sampler), the sampling loss rate of the SS inlet sampler became more significant with the RR values dropping down from 55 to 70%, across different RSCs. The overall results of our comparative study indicate that the sampling system for the reactive gaseous compounds should be checked for the material feasibility to guarantee sufficient analytical reliability.  相似文献   

14.
A multiphase assurance approach was developed for the accurate and precise determination of volatile organic compounds (VOCs) in different microenvironments. This approach includes (i) development of a method including adsorption of VOCs onto a multisorbent media followed by short-path thermal desorption (SPTD) pre-concentration and gas chromatography (GC) coupled to a mass spectrometry (MS) quantification, (ii) validation of the sampling and analytical method and (iii) validation of the data using a multidimensional procedure. Tenax TA and Carbopack B sorbent combinations were used to collect 102 individual VOCs ranging from C5 to C12. Method parameters including thermal desorption temperature, desorption time and cryofocusing temperature were optimized. The average recoveries and method detection limits (MDL) for the target analytes were in the range 80-100% and 0.01-0.14 ppbv, respectively. The method also showed good linearity (R2 > 0.99) and precision (<8%) values. Validation of the method was performed under real environmental conditions at a gas station, in an office and a residential household to examine the influence of variation in meteorological conditions such as temperature and relative humidity and a wide range of VOC concentrations. The sampling and analytical method resulted in successful determination of VOC in different microenvironments. Finally, validation of the data was performed by assessing fingerprint and time series plots and correlation matrices together with meteorological parameters such as mixing height, wind speed and temperature. The data validation procedure provided detection of both faulty data and air pollution episodes.  相似文献   

15.
This paper describes the establishment of a robust method to determine compound specific δD and δ(13)C values of volatile organic compounds (VOCs) in a standard mixture ranging between C(6) and C(10) and was applied to various complex emission samples, e.g. from biomass combustion and car exhaust. A thermal desorption (TD) unit was linked to a gas chromatography isotope ratio mass spectrometer (GC-irMS) to enable compound specific isotope analysis (CSIA) of gaseous samples. TenaxTA was used as an adsorbent material in stainless steel TD tubes. We determined instrument settings to achieve a minimal water background level for reliable δD analysis and investigated the impact of storage time on δD and δ(13)C values of collected VOCs (176 days and 40 days of storage, respectively). Most of the standard compounds investigated showed standard deviations (SD)<6‰ (δD) when stored for 148 days at 4 °C. However, benzene revealed occasionally D depleted values (21‰ SD) for unknown reasons. δ(13)C analysis demonstrated that storage of 40 days had no effect on VOCs investigated. We also showed that breakthrough (benzene and toluene, 37% and 7%, respectively) had only a negligible effect (0.7‰ and 0.4‰, respectively) on δ(13)C values of VOCs on the sample tube. We established that the sample portion collected at the split flow effluent of the TD unit can be used as a replicate sample for isotope analysis saving valuable sampling time and resources. We also applied TD-GC-irMS to different emission samples (biomass combustion, petrol and diesel car engines exhaust) and for the first time δD values of atmospheric VOCs in the above range are reported. Significant differences in δD of up to 130‰ were observed between VOCs in emissions from petrol car engine exhaust and biomass combustion (Karri tree). However, diesel car emissions showed a high content of highly complex unresolved mixtures thus a baseline separation of VOCs was not achieved for stable hydrogen isotope analysis. The ability to analyse δD by TD-GC-irMS complements the characterisation of atmospheric VOCs and is maybe used for establishing further source(s).  相似文献   

16.
This paper compares two analytical methods for determining levels of 90 volatile organic compounds (VOCs) commonly found in industrial and urban atmospheres. Both methods are based on two official methods for determining benzene levels and involve collecting samples by active adsorptive enrichment on solid sorbents. The first method involves solvent extraction and uses activated charcoal as a sorbent. After sampling, the sorbent is extracted with 1 mL of carbon disulfide and then 1 μL of the extract is analysed in a GC-MS. The second method involves thermal desorption (TD) and uses Tenax TA and Carbograph 1TD as sorbents, which allows the whole sample to be analysed. In general, the thermal desorption method showed the best repetitivity and recovery and the lowest limit of detection and quantification for all target compounds. Because of its lower sensitivity, the solvent extraction method needs the preconcentration of large sample volumes of air (720 L vs. 2.64 L for the thermal desorption method) to yield similar limits of detection.The performance of both methods in real samples was tested in a location near to a petrochemical complex. The results of the 24-h samples for the solvent extraction method were compared with the average of 12 2-h samples for the TD method. In some cases, both methods found differences in the VOC concentrations, especially in those compounds whose concentrations fluctuate significantly during the day.  相似文献   

17.
Needle trap devices (NTDs) are improving in simplicity and usefulness for sampling volatile organic compounds (VOCs) since their first introduction in early 2000s. Three different sample transfer methods have been reported for NTDs to date. All methods use thermal desorption and simultaneously provide desorptive flow to transfer desorbed VOCs into a GC separation column. For NTDs having 'side holes', GC carrier gas enters a 'side hole' and passes through sorbent particles to carry desorbed VOCs, while for NTD not having a 'side hole', clean air as desorptive flow can be provided through a needle head by a air tight syringe to sweep out desorbed VOCs or water vapor has been reported recently to be used as desorptive flow. We report here a new simple sample transfer technique for NTDs, in which no side holes and an external desorptive flow are required. When an NTD enriched by a mixture of benzene, toluene, ethylbenzene, and xylene (BTEX) or n-alkane mixture (C6-C15) is exposed to the hot zone of GC injector, the expanding air above the packed sorbent transfers the desorbed compounds from the sorbent to the GC column. This internal air expansion results in clean and sharp desorption profiles for BTEX and n-alkane mixture with no carryover. The effect of desorption temperature, desorption time, and overhead volumes was studied. Decane having vapor pressure of approximately 1 Torr at 20 degrees C showed approximately 1% carryover at the moderate thermal desorption condition (0.5 min at 250 degrees C).  相似文献   

18.
Two methods for the determination of hexahydrophthalic anhydride (HHPA) in air were developed. In a solid sorbent method, HHPA was sampled in Amberlite XAD-2 tubes, eluted in toluene and analysed by gas chromatography with flame ionization detection. The sampling rates were 0.2 and 1.0 l/min. At 15 micrograms/m3 (relative humidity less than 2%) and 27 micrograms/m3 (relative humidity 70%) no breakthrough was observed. However, at 160 micrograms/m3 (relative humidity less than 2%), 6% breakthrough was found. The sampling efficiency of the sampling rates 0.2 and 1.0 l/min did not differ. In a bubbler method, HHPA was sampled in bubblers filled with 0.1 M sodium hydroxide solution. The sodium salt of hexahydrophthalic acid was formed. No breakthrough was observed using a sampling rate of 1.0 l/min. The samples were stable during storage for eight weeks in a refrigerator. The HHP acid was esterified with methanol-boron trifluoride and analysed by gas chromatography-flame ionization detection. Apparatus for the generation of standard atmospheres of HHPA, in the range of 10-3000 micrograms/m3, was developed using the diffusion principle. For the solid sorbent method the precision (coefficient of variation) of the overall method was 2-7%, and for the bubbler method 3-19% (range 15-160 micrograms HHPA/m3; relative humidity = less than 2-70%). A comparison between the two methods was performed using the standard atmosphere. The concentrations found by the solid sorbent method were 86-98% of those found by the bubbler method (range 15-160 micrograms HHPA per m3; relative humidity = less than 2-70%). In work environment air, 93% was found using the solid sorbent method relative to the bubbler method at a mean concentration of 330 micrograms/m3 (coefficient of variation = 39%; range 200-540 micrograms/m3). For both methods, concentrations greater than 3 micrograms/m3 could be quantified at 60 min sampling with a sampling rate of 1.0 l/min.  相似文献   

19.
Sorbent tubes/traps are widely used in combination with gas chromatographic (GC) analytical methods to monitor the vapour-phase fraction of organic compounds in air. Applications range from atmospheric research and ambient air monitoring (indoor and outdoor) to occupational hygiene (personal exposure assessment) and measuring chemical emission levels. Part 1 of this paper reviewed the main sorbent-based air sampling strategies including active (pumped) tube monitoring, diffusive (passive) sampling onto sorbent tubes/cartridges plus sorbent trapping/focusing of whole air samples that are either collected in containers (such as canisters or bags) or monitored online. Options for subsequent extraction and transfer to GC(MS) analysis were also summarised and the trend to thermal desorption (TD)-based methods and away from solvent extraction was explained. As a result of this trend, demand for TD-compatible sorbents (alternatives to traditional charcoal) is growing. Part 2 of this paper therefore continues with a summary of TD-compatible sorbents, their respective advantages and limitations and considerations for sorbent selection. Other analytical considerations for optimizing sorbent-based air monitoring methods are also discussed together with recent technical developments and sampling accessories which have extended the application range of sorbent trapping technology generally.  相似文献   

20.
In this study, a series of experiments were conducted to examine the feasibility of the gas chromatographic approach for the quantification of several odorous volatile organic compounds (VOCs) in environmental samples which included methyl ethyl ketone, isobutyl alcohol, methyl isobutyl ketone, and butyl acetate plus benzene, toluene, and xylene (namely, BTX). The gaseous working standards (WS) of seven compounds were initially calibrated at varying concentration ranges by direct injection (DI) into GC injector. The detection properties of these compounds were then tested with a thermal desorber (TD). The relative sensitivities of three aromatic VOCs differed greatly between DI and TD methods. In contrast, four polar VOCs tend to consistently exhibit relative enhancement in response factors with increasing molecular mass (an exception of butyl acetate), regardless of method. The TD-based analysis was reliable enough to detect all target VOCs below their odor threshold values with their detection limit (DL) values. This TD method, when tested against a number of environmental samples collected from several industrial facilities, confirmed the presence of these odorous VOCs at a wide concentration range.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号