首页 | 官方网站   微博 | 高级检索  
     

High-energy picosecond single-pass multi-stage optical parametric generator and amplifier
作者姓名:余洋  刘钊  刘可  马超  高宏伟  王小军  薄勇  崔大复  彭钦军
作者单位:1.Key Laboratory of Solid-state Lasers, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China;2.Key Laboratory of Functional Crystal and Laser Technology, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China;3.University of Chinese Academy of Sciences, Beijing 100190, China
基金项目:the National Science Foundation for Young Scientists of China(Grant No.61805259);Youth Innovation Promotion Association,CAS,and Chinese Academy of Sciences funding(Grant No.ZDRW-KT2019-4-01).
摘    要:We demonstrate a new management of multi-stage optical parametric generator(OPG)and amplifier(OPA)to obtain high-energy picosecond sources with high beam quality.The setup of multi-stage OPG-OPA requires mode-matching between the pump beam and the stable mode of the OPG-OPA.In a proof-of-principle experiment,the single-pass multi-stage OPG-OPA consists of three walk-off compensated KTP crystal pairs and two lenses,pumped by an 86 ps,1064 nm 10 kHz picosecond laser.The signal light at~1.77μm has an average output power of 502 mW with record energy up to 50.2μJ.The beam quality factor of the signal light can be improved toM2x ×M2yafter filtering out about 40%signal power.To the best of our knowledge,it is the first picosecond single-pass multi-stage OPG-OPA pumped at kHz regime.

关 键 词:HIGH-ENERGY  PICOSECOND  optical  parametric  frequency  conversion
收稿时间:2021-04-16

High-energy picosecond single-pass multi-stage optical parametric generator and amplifier
Yang Yu,Zhao Liu,Ke Liu,Chao Ma,Hong-Wei Gao,Xiao-Jun Wang,Yong Bo,Da-Fu Cui,Qin-Jun Peng.High-energy picosecond single-pass multi-stage optical parametric generator and amplifier[J].Chinese Physics B,2022,31(1):14204-014204.
Authors:Yang Yu  Zhao Liu  Ke Liu  Chao Ma  Hong-Wei Gao  Xiao-Jun Wang  Yong Bo  Da-Fu Cui  Qin-Jun Peng
Affiliation:1.Key Laboratory of Solid-state Lasers, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China;2.Key Laboratory of Functional Crystal and Laser Technology, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China;3.University of Chinese Academy of Sciences, Beijing 100190, China
Abstract:We demonstrate a new management of multi-stage optical parametric generator (OPG) and amplifier (OPA) to obtain high-energy picosecond sources with high beam quality. The setup of multi-stage OPG-OPA requires mode-matching between the pump beam and the stable mode of the OPG-OPA. In a proof-of-principle experiment, the single-pass multi-stage OPG-OPA consists of three walk-off compensated KTP crystal pairs and two lenses, pumped by an 86 ps, 1064 nm 10 kHz picosecond laser. The signal light at ~1.77 μm has an average output power of 502 mW with record energy up to 50.2 μJ. The beam quality factor of the signal light can be improved to $M_{x}^{2} \times M_{y}^{2}=1.87\times 2.16$ after filtering out about 40% signal power. To the best of our knowledge, it is the first picosecond single-pass multi-stage OPG-OPA pumped at kHz regime.
Keywords:high-energy  picosecond  optical parametric frequency conversion  
本文献已被 维普 等数据库收录!
点击此处可从《中国物理 B》浏览原始摘要信息
点击此处可从《中国物理 B》下载免费的PDF全文