首页 | 本学科首页   官方微博 | 高级检索  
     

用于硫酸庆大霉素高效液相色谱分离-电化学测定的四电位波型的优化
引用本文:蔡亚岐,牟世芬. 用于硫酸庆大霉素高效液相色谱分离-电化学测定的四电位波型的优化[J]. 中国化学, 2005, 23(9): 1207-1212. DOI: 10.1002/cjoc.200591207
作者姓名:蔡亚岐  牟世芬
作者单位:[1]State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
基金项目:Project supported by the Major State Basic Research Development Program (No. 2003CB415001) of China and the National Natural Science Foundation of China (No. 20475060).
摘    要:提出并优化了用于庆大霉素测定的四电位检测波型,建立了庆大霉素的高效液相色谱分离-电化学测定新方法。在该新检测波型中,使用了负的清洗电位,该清洗电位具有清洗效果好,对金工作电极的氧化溶解损伤小,因而建立的分析方法具有满意的精密度。该分析方法已经被应用于两种实际样品的测定。

关 键 词:电化学 脉冲 电势 庆大霉素 电极
收稿时间:2004-09-13
修稿时间:2004-09-132005-05-23

Optimizing the Quadruple-potential Waveform for the Determination of Gentamicin Sulfate by High Performance Liquid Chromatography with Pulsed Electrochemical Detection
CAI Ya-Qi,MOU Shi-Fen. Optimizing the Quadruple-potential Waveform for the Determination of Gentamicin Sulfate by High Performance Liquid Chromatography with Pulsed Electrochemical Detection[J]. Chinese Journal of Chemistry, 2005, 23(9): 1207-1212. DOI: 10.1002/cjoc.200591207
Authors:CAI Ya-Qi  MOU Shi-Fen
Abstract:In this paper, a quadruple-potential waveform was investigated and optimized for the determination of gentamicin by reversed phase ion-pair chromatography. Instead of a relatively high positive potential, a negative potential was adopted as a potential for the cleaning of gold working electrode. By this way, the formation of gold oxide resulting from the application of high positive potential during the analyte detection and electrode cleaning was greatly reduced, and therefore, the dissolution and recession of gold working electrode was also reduced. The good condition of gold working electrode achieved by this quadruple-potential waveform can help us to obtain a good reproducibility. In order to acquire signal-to-noise ratio as high as possible, several waveform parameters affecting the detection of gentamicin were carefully selected. The analytical method has been applied to the determination of two real gentamicin samples, and good results with low relative standard deviation not more than 4% were obtained.
Keywords:quadruple-potential waveform   pulsed electrochemical detection   reversed phase ion-pair chromatography   gentamicin
本文献已被 维普 等数据库收录!
点击此处可从《中国化学》浏览原始摘要信息
点击此处可从《中国化学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号