首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Determination of chlorogenic acid by flow injection irreversible biamperometry
作者姓名:Li  Jun  Li  Qi  Feng  Chen  Lai  Bo  Yu  Zhao  Heng  Zhong  Jun  Feng  Hao  Cheng  Hong  Xing  Kong  Jian  Ling  Wu
作者单位:Li Jun Lia,*,Qi Feng Chen b,Lai Bo Yu b,Zhao Heng Zhong b,Jun Feng b,Hao Cheng a,Hong Xing Kong a,Jian Ling Wu b aDepartment of Biological and Chemical Engineering,Guangxi University of Technology,Liuzhou 545006,China bCollege of Chemistry and Chemical Engineering,Guangxi University,Nanning 530004,China
摘    要:A flow injection irreversible biamperometric method for the determination of chlorogenic acid is described.The proposedmethod is based on the electrochemical oxidation of chlorogenic acid at pretreated platinum electrode and the reduction ofpermanganate at another electrode to form an irreversible biamperometric detection system.Under the external potential difference(△E)of 0 V,in the 0.05 mol/L sulfuric acid,chlorogenic acid can be determined over the range 0.8-120 mg/L with a samplemeasurement frequency of 80 samples/h.The detection limit is 0.18 mg/L.The proposed method exhibits the satisfactoryreproducibility with a relative standard derivation(R.S.D.)of 2.21%for 19 successive determinations of 40 mg/L.

关 键 词:绿原酸  测定  流动注射  单向双安培滴定法  多酚类
收稿时间:2006-12-04

Determination of chlorogenic acid by flow injection irreversible biamperometry
Li Jun Li Qi Feng Chen Lai Bo Yu Zhao Heng Zhong Jun Feng Hao Cheng Hong Xing Kong Jian Ling Wu.Determination of chlorogenic acid by flow injection irreversible biamperometry[J].Chinese Chemical Letters,2007,18(4):431-434.
Authors:Li Jun Li  Qi Feng Chen  Lai Bo Yu  Zhao Heng Zhong  Jun Feng  Hao Cheng  Hong Xing Kong  Jian Ling Wu
Institution:1. Department of Biological and Chemical Engineering, Guangxi University of Technology, Liuzhou 545006, China;2. College of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, China
Abstract:A flow injection irreversible biamperometric method for the determination of chlorogenic acid is described. The proposed method is based on the electrochemical oxidation of chlorogenic acid at pretreated platinum electrode and the reduction of permanganate at another electrode to form an irreversible biamperometric detection system. Under the external potential difference (ΔE) of 0 V, in the 0.05 mol/L sulfuric acid, chlorogenic acid can be determined over the range 0.8–120 mg/L with a sample measurement frequency of 80 samples/h. The detection limit is 0.18 mg/L. The proposed method exhibits the satisfactory reproducibility with a relative standard derivation (R.S.D.) of 2.21% for 19 successive determinations of 40 mg/L.
Keywords:Flow injection  Irreversible biamperometry  Chlorogenic acid  Honeysuckle
本文献已被 CNKI 维普 万方数据 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号