CsI(Tl)+Si-APD探测器的性能测试
引用本文:焦磊,金仕纶,李加兴,王建松,杨彦云,马朋,马军兵,白真,刘星泉,周济人,段芳芳,张兴.CsI(Tl)+Si-APD探测器的性能测试[J].原子核物理评论,2017,34(2):190-194.
作者姓名:焦磊  金仕纶  李加兴  王建松  杨彦云  马朋  马军兵  白真  刘星泉  周济人  段芳芳  张兴
作者单位:1.重庆大学动力工程学院, 重庆 400044;
基金项目:国家自然科学基金资助项目(U1432247,U1332126,11075133,11575256,10205019);国家重点基础研究发展计划(973计划)资助项目(2014CB845405);“西部青年学者”项目(科发人函字[2015]90号)
摘    要:介绍了Si-APD的工作原理并对Si-APD中的暗电流进行了理论分析。基于RIBLL上产生的放射性核束流,使用CsI(Tl)+Si-APD探测器对中能重离子进行了能量测试。测试结果显示,CsI(Tl)+Si-APD探测器测量20 MeV/u的重离子时,可得到3%的能量分辨;同时还发现Si-APD中的暗电流大小以及入射粒子的能量大小都会对探测器的能量分辨产生影响。In this paper, the working principle of Si-APD was introduced and the dark current of Si-APD was analyzed theoretically. The intermediate energy heavy ions, which are produced on the RIBLL(Radioactive Ion Beam Line in Lanzhou), were measured with CsI(Tl)+Si-APD detector. The energy resolution of CsI(Tl)+Si-APD detector is about 3% for heavy ions with energy around 20 MeV/u. It is also found that the energy resolution of detector can be in uenced by the dark current of Si-APD and the energy of incident particles.

关 键 词:暗电流    CsI(Tl)    Si-APD    能量分辨
收稿时间:2016-06-24

Performance Test of the CsI(TI)+Si-APD Detector
JIAO Lei,JIN Shilun,LI Jiaxing,WANG Jiansong,YANG Yanyun,MA Peng,MA Junbing,BAI Zhen,LIU Xingquan,ZHOU Jiren,DUAN Fangfang,ZHANG Xing.Performance Test of the CsI(TI)+Si-APD Detector[J].Nuclear Physics Review,2017,34(2):190-194.
Authors:JIAO Lei  JIN Shilun  LI Jiaxing  WANG Jiansong  YANG Yanyun  MA Peng  MA Junbing  BAI Zhen  LIU Xingquan  ZHOU Jiren  DUAN Fangfang  ZHANG Xing
Institution:1.College of Power Engineering, Chongqing University, Chongqing 400044, China;2.Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China;3.Institute of Physical Science and Technology, Southwest University, Chongqing 400715, China
Abstract:In this paper, the working principle of Si-APD was introduced and the dark current of Si-APD was analyzed theoretically. The intermediate energy heavy ions, which are produced on the RIBLL(Radioactive Ion Beam Line in Lanzhou), were measured with CsI(Tl)+Si-APD detector. The energy resolution of CsI(Tl)+Si-APD detector is about 3% for heavy ions with energy around 20 MeV/u. It is also found that the energy resolution of detector can be in uenced by the dark current of Si-APD and the energy of incident particles.
Keywords:dark current  CsI(TI)  Si-APD  energy resolution
本文献已被 CNKI 等数据库收录!
点击此处可从《原子核物理评论》浏览原始摘要信息