首页 | 本学科首页   官方微博 | 高级检索  
     


Fast chromatographic method for the determination of dyes in beverages by using high performance liquid chromatography—Diode array detection data and second order algorithms
Authors:Marí  a J. Culzoni,Agustina V. Schenone,Natalia E. Llamas,Mariano Garrido,Maria S. Di Nezio,Beatriz S. Ferná  ndez Band,Hé  ctor C. Goicoechea
Affiliation:1. Laboratorio de Desarrollo Analítico y Quimiometría (LADAQ), Cátedra de Química Analítica I, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral – CONICET, Ciudad Universitaria, Santa Fe (S3000ZAA), Argentina;2. FIA Laboratory, INQUISUR – CONICET, Universidad Nacional del Sur, Av. Alem 1253, (B8000CPB) – Bahía Blanca, Buenos Aires, Argentina
Abstract:A fast chromatographic methodology is presented for the analysis of three synthetic dyes in non-alcoholic beverages: amaranth (E123), sunset yellow FCF (E110) and tartrazine (E102). Seven soft drinks (purchased from a local supermarket) were homogenized, filtered and injected into the chromatographic system. Second order data were obtained by a rapid LC separation and DAD detection. A comparative study of the performance of two second order algorithms (MCR-ALS and U-PLS/RBL) applied to model the data, is presented. Interestingly, the data present time shift between different chromatograms and cannot be conveniently corrected to determine the above-mentioned dyes in beverage samples. This fact originates the lack of trilinearity that cannot be conveniently pre-processed and can hardly be modelled by using U-PLS/RBL algorithm. On the contrary, MCR-ALS has shown to be an excellent tool for modelling this kind of data allowing to reach acceptable figures of merit. Recovery values ranged between 97% and 105% when analyzing artificial and real samples were indicative of the good performance of the method. In contrast with the complete separation, which consumes 10 mL of methanol and 3 mL of 0.08 mol L−1 ammonium acetate, the proposed fast chromatography method requires only 0.46 mL of methanol and 1.54 mL of 0.08 mol L−1 ammonium acetate. Consequently, analysis time could be reduced up to 14.2% of the necessary time to perform the complete separation allowing saving both solvents and time, which are related to a reduction of both the costs per analysis and environmental impact.
Keywords:Second order advantage   Dyes   Beverages samples   HPLC-DAD   Multivariate curve resolution alternating least squares   Residual bilinearization
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号