首页 | 本学科首页   官方微博 | 高级检索  
     


Feedback flow control of a low-Re airfoil by flap actuators
Affiliation:1. Department of Mathematics and Statistics, Memorial University of Newfoundland, St. John׳s, NL, Canada A1C 5S7;2. Department of Mathematics, Middle East Technical University, Ankara, Turkey;1. Institute of Vibration, Shock and Noise, Shanghai Jiao Tong University, Shanghai 200240, PR China;2. State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai 200240, PR China
Abstract:The present paper describes the applicability of the active flow control device, mini electromagnetic flap actuators attached on the leading edge of an airfoil, for the flow separation under both the steady and the unsteady flow conditions in the low Reynolds number region. At first, lift and drag have been measured for a wide variety of the wind speed Reynolds numbers and the angles of attack for the steady flow condition. Then, effects of some simple feedback flow controls, where the time-dependent signal of the lift-drag ratio have been used to detect the stall and served as a trigger to start the actuation, have been explored under the unsteady flow condition for evading the stall. In every low Reynolds number ranging from 30 000 to 80 000, the present actuators worked quite well to delay the stall, increasing in the lift and delaying the stall angle of attack. These aerodynamic modifications by the flap actuators obtained from the steady flow were found to be available even if the manipulation of the actuators started after the stall. Activation threshold of the lift-drag ratio as the input for the feedback control was determined from a stall classification map obtained under the steady flow experiment. Effectiveness of this feedback control was then demonstrated under the condition of the wind speed decrease (Reynolds number from 80 000 to 40 000) keeping the angle of attack constant at 11°, at which the stall occurs without the active control. Immediately after the sudden velocity decrease, the decrease in the lift-drag ratio were detected and the dynamic actuations were successfully started, resulting in evading the stall and keeping high and stable lift. An additional operation of the feedback, in which the running actuation is turned off when the lift-drag ratio shows lower than the second threshold value after operation, was revealed to be effective to keep the high lift force under the condition combined with the wind speed increase and decrease within the low Reynolds number range treated in this study.
Keywords:Airfoil  Active flow control  Feedback  Flap actuators  Stall
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号